| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹2.0 Cr | L1 | Accepted-AOC LOA |
| 2 | L2₹2.2 Cr+₹21.2 L (10.7%)Rejected-Finance | ₹2.2 Cr+₹21.2 L (10.7%) | L2 | Rejected-Finance Highest |
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
7 Apr 2025, 5:00 pmClosed
NAVEEN RATHEE
ED - Ambala
Strengthening of road with Cement Concrete Pavement from Shaharanpur Yamunanagar Ladwa Kurukshetra Pehowa Road (SH-06) (Road ID 8023) form Km. 85.00 to 90.00 in District Kurukshetra ( Pdg. Illumination Work).
2025_HRY_436883_1
202542296FC3 95ED 49E0 B9DF 454B1596B4BA663BAR
Open Tender
Civil Works
Works
180 days
Ambala Cantt.
Strengthening of road with Cement Concrete Pavement from Shaharanpur Yamunanagar Ladwa Kurukshetra Pehowa Road (SH-06) (Road ID 8023) form Km. 85.00 to 90.00 in District Kurukshetra ( Pdg. Illumination Work).
2 documents required · 2 mandatory
₹15,000
₹3.8 L
Yes
27 May 2025
27 Mar 2025
8 Apr 2025
28 Mar 2025
7 Apr 2025
28 Mar 2025
Amount
[23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA [Through Rate]
[23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) [Through Rate]
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
[23.27.3]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 3. M.S. pedestal of size 750 mm wide , 1200 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate]
[23.5.6.6]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
[24.1.11]EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. [Through Rate]
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
[24.12.38]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITHOUT SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 38. 35 Sq mm 3.5 core (Arm.) [Through Rate]
[24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate]
[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core [Through Rate]
[24.4.7.2]STREET LIGHT 7.2. Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia [Through Rate]
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]
[24.8.7]RCC FOUNDATIONS FOR OCTAGONAL POLES 7. Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 9m high pole [Through Rate]
Cost of cutting of metal road and repairing, filling etc. including all labour charges with petty materials complete in all respect upto the entire satisfaction of Engineer-in-charge of the work.
`SITC of 9 Mtr. high FLAG Colour light emitting decorative M.S pole. The pole 9mtr height above the ground level having top 60.0mm O.D. of 4 mtr and bottom 140.0mmO.D. of 5mtr with avg. thickness of 3.2mm. The pole middle part illuminated in Green colour 1mtr, White 1mtr and Saffron 1mtr with polycarbonate structure of 150mm O.D. with avg thickness of 2mm as per drawing. Illuminated diffuser is made of UV stabilized PC back lit by 100W led mounted PCB with 12V constant voltage driver. The pole shall also be provided with flush door at the bottom with proper strengthening to the cutout of the door opening. A junction/ looping box with 32 Amps heavy duty connector shall be built into the pole. Pole with flag colour and 1mtr double side bracket arrangement for the top mounting fixture as per drawing. The pole shall be made of mild steel with precision machining and filling job to achieve good finish and a fine coat of primer on each element before assembling. After assemble of each one coat of primer and two coats of P.U paint are applied. Approve colour UV resist coating of mat/glossy/metallic finish followed after air drying of pole. The pole must be of IP 66 rating. The pole shall have a waterproof flush door and locking arrangement. The base plate 320x320x12mm of the pole is design with elongated foundation holes for fine alignment of the pole during installation. LED a CRI )70 The luminaire shall have a life class of 50,000 hours and driver efficiency of ) 80%, THD 0.9, Internal surge protection of 4 kV with 10kv additional SPD. Led should be of 50,000 hours and accessories required to complete the job in all respect including erection charges, including connection of the same upto the entire satisfaction of Engineer in Charge of the work (Make as per list attached ).
`SITC of 90Watt LED Street light fitting CCT 5700 k having 100 lumens per watt, PF )0.95, CRI )70 with warranty 2 year alongwith allied items, accessories required to complete the job in all respect including erection on pole for fixing including connection of the same upto the entire satisfaction of Engineer in Charge of the work (Make as per list attached ).
`Supply and installation of 25mm thick GI plate of size 0.5Mx0.5M having 8 holes arrangement for old foundation and new pole base including all necessary arrangements like suitable nuts and bolts, drilling, welding, labour charges etc. to complete the work to the complete satisfaction of Engineer-in-Charge. `
Supply and erection of 63 Amp. 3 Pole/230V Astronomical automatic time switch of alongwith contactor of required capacity movement controlled by precisaty quartz osciliation operation on main supply of continue to run on built in rechargeable nickel cadium cell for 150 hours in the event of power failure including cost of contractor complete in all respect upto the entire satisfaction of Engineer-in-charge of the work (Make as per list attached ). ..
Less amount for dismantling and Buy back of existing street light poles, LED fittings and allied items .
M/S PANJETA ELECTRICALS (BID ID -1237433)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .