Loading…
Loading…
Tender Value
₹6.4 Cr
EMD Value
₹4.7 L
Closing Date
6 Mar 2026, 3:00 pmClosed
Provision of AI infrastructure at 20 PRS locations over Guntakal division for real time monitoring. (Vendodu, Venkatagiri, Srikalahasti, Renigunta, Tirupati, Chandrairi, Pakala, Chittoor, Piler, Kalikiri, Vayalpad, Madanapalle road, Mulacalacheruvu, Kadiri, Mudigubba, Dharmavaram, Anantapur, Kalluru, Proddaturu, Jammalamadugu)
01-SNT-03-2026~SCR
01-SNT-03-2026
Open
Works - General
12 Months
Anantapur, Andhra Pradesh
₹0
₹4.7 L
6 Mar 2026
10 Feb 2026
20 Feb 2026
Supply of UTP CAT 6 Cable (Roll is 305 Mtr) of D.LINK/AMP/KRONE or similar make. Inspection by Consignee.
Supply of HDPE pipe of 110mm Dia with material grade PE 100 as per specification IS Specification 4984: 1995 up to latest amendment. Inspection by Consignee.
Supply of 50 Pair cable of 0.5mm dia, polythene insulated, polythene sheathed, jelly 3 filled underground telephone cable with poly aluminium moisture barrier, annealed copper conductor, polythene jacketed double steel tape armoured as per specification IRS: TC 41/97 Amd. 3 or latest. Inspection by Consignee.
Supply of Permanently lubricated HDPE Duct with outer diameter of 40mm and inner diameter of 33mm as per specification RDSO/SPN/TC/45/2013 Revision 2.0. The length of the duct shall be 1km. Two end plugs shall be provided along with the drum. Inspection by Consignee.
Supply of 8 port with 2 SFP networking switch with POE (8 Port Managed PoE + Layer 2 access Switch) as per specification of make/model: cisco or D-Link or Netgear or similar. Inspection by Consignee.
Supply of Manageable non-POE 24 port switch with minimum 02 SFP ports of D-Link or similar. Inspection by Consignee.
Supply of 10TB internal hard disc with power and SATA data cables suitable for 16 channel super NVR of reputed make. Inspection by Consignee.
Supply of 2 TB external hard disc of Seagate/WD make or similar. Inspection by Consignee. Above/
A2-Supply Portion (Non SOR Items) 3688780.00 Below/P
Supply of 24 U Rack BESTNET Make or similar. Inspection by Consignee.
Supply of 10/100Mbps single mode media converter as per spec. Inspection by Consignee.
Supply of RJ 45 Jacks of Make:AMP /Dlink/ ADC/ Krone. Inspection by Consignee.
Supply of SC-PC to SC-PC patch cards (5 mtrs length) with 0dB coupler. Inspection by Consignee.
Supply of 2w/4w Fast Ethernet/LAN extenders 30 Mbps works up to 10 Km or more with Built-in internal dual AC 230V/ DC-48V power supply from a single socket as per specs make: MROTEK WL-LG or Cisco or Perle. Inspection by Consignee.
Supply of Patch Cards 7' (DAX make). Inspection by Consignee.
Supply of 3 core, 2.5sqmm PVC insulated flexible fire resistant Power Cable of Spec.No. IS:694:1990 reaffirmed 1995 or latest of reputed make like Havells, finolex fine cap etc., Inspection by Consignee.
Supply of 22 inch monitor with HDMI port Samsung/Dell or equalent. Inspection by Consignee. Above/
Supply and installation of 19" - 42 U Rack complete with fittings for housing SDH equipment, FDMS, DDF and other equipment like cable managers, completely wired using krone module and other equipment like runaway ladders etc., as per technical specification below. It should be able to lock all the equipment with only order wire Telephone outside the rack. The rack should be of APW President / Rittal make or similar. The components of the rack are specified below. 1 It includes transportation and installation of rack in prefab/building at specified stations. 1. Rack S33 42U 600'W x 600D - 1 No. 2. Fixed side panels 42U x 600 D - 2 Nos. 3. Front Glass door plain 42U/600W - 1 No. 4. Rear MS Door Plain 42U/600W - 1 No. 5. Castor with brakes-2 Nos. 6 Fans directly mounted on the top 48V DC 90 CFM-2 Nos. 7. Krone mounting bracket - 01 Nos. 8. MCB Mounting panel with MCBs - a. 32 Amps, MCBs(DP) - 2 Nos. & 6Amps MCBs (DP) - 6 Nos. 9. Earth continuity Kit - 01 No. 10. Equipment Trays - 5 Nos. 11. Channel with cable loops 42U - 2 Nos " Inspection by Consignee.
Supply and Installation of OFC joint enclosure and splicing of Optic fibre cable (24 fibres) and testing as per technical specification No. GR OJC-2/02 Sept 2003. Supply of Splice 2 Enclosure (24 fibre) shall be of TVS make Part No.1500-L18X-XX or similar as per Board specification of TEC.& as per RDSO/SPN/TC/68/2014 Revision 1.0 amd 1 or latest . All materials including Fusion splicing machine used for fibre splicing and, OTDR for testing and other testing materials if any shall be arranged by the contractor. Inspection by Consignee.
Supply and installation of rack mounted 24 fibre Distribution Management System (FDMS) of size 1U, of Reputed/Branded company make as per specification RDSO/SPN/TC/37/2020 Revision 4.0 with latest amendments. The FDMS shall include 24 SC-PC/Required adaptors having insertion loss less than or equal to 0.1dB and 24 numbers 900 micron 1.5m SC-PC/Required pigtails.
Track crossing/ Road Crossing by Horizontal Boring method at culverts/track/pucca road as per SCR Drg. No. 5770. This also includes insertion of HDPE pipe of 110 mm/G.I Pipe of 100 mm in the bore drilled (HDPE pipe/ GI pipe is to be supplied by Railway).
Breaking of metal/ tar road and refilling after laying the cables as per drawing no. SDO/CABLE LAYING/010. The surface of the road shall be concreted to match with the old surface.
Laying different type of cables in the trench.
"Supply & installation of Rack 19"" wall mount 6U/500MM D with front glass door and 7 lock and key including the following: 1. 1U Cable manager - 1 No. 2. 1U Cantilever tray - 1 No. 3. AC distribution box 5X5 amps - 1 No. 4. Front panel H/W PKT of 10 Sets - 1No. 5. Cooling fan of 230V AC operated"
Laying of HDPE duct 40/33 mm dia in the trenches and in protective works already provided.
Blowing of armoured optic fibre cable (OFC Cable supplied by Railways) into the duct supplied vide other NS item of supply portion by using blowing machine and associated works. 10% 9 of OFC length to be blown extra on both ends of Duct i.e. total 20% of Duct length. Before blowing the duct integrity shall be tested. If any defect is found during duct integrity test, the entire length of HDPE duct from one chamber to another chamber is to be replaced by the contractor at his own cost. Payment will be made as per the length of Duct from which OFC is Blown.
Trenching under Rails for crossing the track (Track Crossing) and refilling of trenches as per SCR Drg. No. 5768. The track crossing shall be done at right angles. The depth of cable trench 10 shall be 1.2 meter below the rail flange. The depth between top cable and the level of rail flange of the rail shall never be less than 1.0 meter. The ballast shall be stacked separately while making the trench and the earth soil shall be stacked separately. While re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. This work has to be done under supervision of supervisor of S&T and supervisor of P.Way.
Supply and fixing of different sizes of PVC casing /Pipes as required by Railway at site by fixing /clamping to the wall for indoor wiring purposes. All the material required for fixing PVC casing/Pipes are to be supplied by contractor. Inspection by Consignee.
Supply & Laying of G.I Pipes 100mm diametre with medium and threaded collar & coupler, quality to specification IS.1239 (part-I) 1990 and galvanised to specification IS.4736-1986. Inspection by Consignee. Route Kilo
Excavation of trench, including marking of cable alignment, clearing of jungle, roots of trees, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil including soft rocky area as per RDSO Sketch No. SDO/CABLE LAYING/003, as directed by engineer in-charge. Depth of 1200mm and width of 300mm. Inspection by Consignee.
Excavation of jointing pit and provision of RCC/FRP joint / Loop chambers of 90 Cms. Inner dia 60 Cms depth and 3mm thickness with two pieces of top cover with hooks each and bottom 14 cover with hole for drainage and cable entry as per Drg. No. RAILTEL/SR/OFC/ 2009/12 and as directed by Engineer to be provided at every joint location and at every Kilometre loop etc., The chamber shall be filled with sand mixed with anti-stermic power, back filling and ramming of trench after HDPE duct laying, splicing and commissioning.
Excavation of coil pit up to a depth of 1 meter and dia of 1.5 meter for providing coil at location box, point, signals etc., This includes back filling and ramming of trench / pit after laying the cable and consolidation of soil. Above/
B2-Labour Portion (Non SOR Items) 38330040.00 Below/P
Laying of data cable / power cable/CAT-6 cable/PA System cable/OFC.
Supply and installation of 1KVA line interactive UPS system with built in batteries. Inspection by Consignee.
Supply & installation of 2KVA capacity online UPS systems with battery of 12V-65 AH capacity-06 Nos for battery back up of 120 mins, with isolation transformer, True On-Line double 3 Conversion UPS with PWM-IGBT technology with cold start facility ,suitable for single phase AC input & single phase AC output, Mains On, Inverter On, Overload, Load On Mains, Load On Battery, Battery Low with Sealed Maintenance Free (SMF) Battery with stand and Floor mounted type of make: APC/Numeric/Emerson. Inspection by Consignee.
Supply & Transportation of 12 Port LIU fully loaded with 12 simplex SC couplers and 12 SC connectors. Inspection by Consignee.
Cutting of trench across / on platform for a depth 10cm and width of 10cm with marble cutting machine and filling the trench after laying the cables and restoring the surface with marbles. 1790000.0
"Design, development, supply, installation of MVIS (Machine Vision based Inspection System). • 3 Full HD Ultra High-Speed with motion blur-free Camera Edge Analytics Systems and 6 long range Laser sensor which can perform detection of defects and abnormalities on Body/Doors/ Floor visible parts at running trains. • 1 Night Vision long range camera for train detection. • Residual Material Detection • Door condition assessments. • Uneven loading Detection. • 180 days of media storage with Wagon Number Scan, multiple alerts, web portal with edit and user input options. WhatsApp Alert system. • Filter and search on at webportal+ Smart Analytical Visualization. • 7 Hr backup & 8 high-power LED lights, GI poles and other civil material and construction."
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022.pdf
ATTACHMENT
JPOSTCablecut.pdf
ATTACHMENT
FORMSANDANNEXURES.pdf
ATTACHMENT
GCCApril2022Amendments_compressed.pdf
ATTACHMENT
SplConditions01-SNT-03-2026.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .