| 1 | | a) The PV Module Shall contain Poly Crystalline silicon solar cells must have MNRE certified
b)The power output of the modules under STC would be a minimum 330 WP at a voltage of 41(+/-)0.2 v
c) The open circuit voltage of the PV modules under STC would be 48.7 Volts
d) The module efficieincy would be 19.56%
e) A bird spike shall be provided to avoid bird sitting on the solar module at the higest point of the module structure
f) SPV module shall be highly reliable lightweight and shall be a service of life of more than 25 years It shall have a limited power loss of not more than 10% of normal output at the end of 10 years and not more than 20% at the end of 25 years
g) The solar module shall be able to withstand the following environment at conditions normally encountered at the site rainfall of 40mm humidity level upto 95%
h)Strip must contain the following Manufacture name module name module number year of make | 147 | Nos | Avinash Dhari 734015,Vidyut Nagar, Post Satellite Township | 90 |
| 2 | Solar Pump Controller VFD | Solar Pump Controller shall contain
a) HP (KW) 1 to 50 HP (0.75 to 110 KW) b) DC Input Voltage 150 to 700 Vdc + 10% c) AC output Voltage 120 to 415 Vac 3e d) Output Current 3 to 210 Apm e) Overload Current 150% For 60 Seconds 200% For 1 Second
f) Protective Method IP 20 IP 54 IP 65 Enclosed Type
g) Output frequency 1 to 400 HZ h) MPPT Efficiency 99.9% Ambient Temperature -10 to + 60 C | 49 | Nos | Avinash Dhari 734015,Vidyut Nagar, Post Satellite Township | 90 |
| 3 | Solar Mono -Block Pump shall contain 0.5 HP | a) Voltage 110 Volt b) Watt 850 W
c) Head ( in meters) 40 meter
d) Discharge in LMP 35 LMP
e) Shut off Head 55 meter
f) Overall Efficiency 54.90 %
g) Outer Dia 95 mm
h) Maximum AMP 6.5 A Size of Cable 2.5 sqmm. | 49 | Nos | Avinash Dhari 734015,Vidyut Nagar, Post Satellite Township | 90 |
| 4 | Solar Panel Mounting Structure | M .S Structural works for solar panels on roof area connected to one another as per desing direction of engineer in charge complete include cutting to requisite shape and lenth fabrication with necessary bolting metal are welding conforming to IS 816 1995 electrodes of approved make and brand conforming to IS 814 1957 haulage hoisting and erection all complete (Material M.S Square Pipe Size 50x50 mm) | 49 | SET | Avinash Dhari 734015,Vidyut Nagar, Post Satellite Township | 90 |
| 5 | On-Off Auto Censer Device Floating Switch and Others | The newly release 1500 volt connectors are with highest current rating among connectors used PV DC application It supports are cable range up to 16sq mm for TUV and 6A WG for UL With higher voltage higher current and wider cable range out TUV UL 1500 1000V series provide an optimal solution for customer to achive Balance of System | 49 | Nos | Avinash Dhari 734015,Vidyut Nagar, Post Satellite Township | 90 |
| 6 | PVC Flexible copper wire 1.5mm 3 core cable for VFD to Mono-block Pump | 1.5mm 3 core cable for VFD to Mono block Pump | 1,470 | Mtr | Avinash Dhari 734015,Vidyut Nagar, Post Satellite Township | 90 |
| 7 | Copper cable 6mm cable Single core for Panel to VFD | 6mm cable Single core for Panel to VFD | 784 | Mtr | Avinash Dhari 734015,Vidyut Nagar, Post Satellite Township | 90 |
| 8 | | There are some major step to Solar installation that your chose Solar will generally follow
i) insatallation of Mono-Block Pump
ii) Ordering equipment iii) Solar panel installation | 49 | SET | Avinash Dhari 734015,Vidyut Nagar, Post Satellite Township | 90 |