Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 LAccepted-AOC D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹45.3 L+₹3.6 L (8.55%)Rejected-Finance | L2 | Rejected-Finance Not Lowest |
Tender Value
₹47.4 L
EMD Value
₹94,800
Closing Date
13 Dec 2021, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
SPECIAL REPAIRS TO BLDG NO P-08 (HANGER-8) IN TP AREA UNDER SPECIAL REPAIRS B/R AND AS AND AS TO LABS NEAR C2 HANGER AND SPECIAL VEHICLE PARKING SHED IN TP AREA UNDER LBW, PROVN OF FRESH WATER SUPPLY LINE FROM NON-TP CONTROL ROOM OF SOLAR PLANT TO
2021_MES_488435_1
GE (P)/N/K/8843 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class D, Category a (i)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹94,800
Yes
3 Feb 2022
15 Nov 2021
15 Dec 2021
15 Nov 2021
13 Dec 2021
29 Nov 2021
Amount
Dismantling of plain or corrugated asbestos cement sheets including ridge of any gauge, thickness, including nainital or similar pattern as in roof covering.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling of wall and ceiling boards any thickness including cover fillets, including removing of dismantled material from work site all as directed.
Dismantling old decayed timber scantling in fillets, rafters, purlins etc under 40 sq cm section.
S&F for 6 mm thick Asbestos cement plain building boards, fixed to timber framework with screws .
S&F for Asbestos cement building board cover strips, 50mm x 5mm, with bevelled edges over joints including all mitres, etc., and fixed with screws .
S&F for 2nd class soft wood plain fillets square, rectangular or triangular in section, sectional area exc 13 sq cm but n exc 25 sq cm clean sawn, secured with nails or brads.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm below or above ground level including removal of demolished materials from work site complete all as specified and as directed
M&L for providing cement concrete type B-1,1:2:4 (using 20mm graded stone aggregate) as roof kerbs, mud stops, rounded or chamfered on edges .
M&L for providing cement concrete type B-1,1:2:4 (using 20mm graded stone aggregate) as cast in situ in lintels upto 1.5m span, cills and other similar bands, plinth courses, string courses, lacing courses, parapets, railings upto 60 cm height, copings, coping, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating .
M&L for 100 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floors finished with using spike roller for making impression of expanded metal while the concrete is green .
M&L for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection and paving finished cement concrete surfaces even and fair without using extra cement .
M&L for repair to beam/ chajja/ drop/ facia (broken/ damaged), making good with PCC 1:1.5:3 type A1 or cement mortar 1:3, rendering 15 mm thick with using water proofing compound, sides and soffits in cement mortar 1:4 including necessary form work wherever damaged including re-inforcement duly welded if required, including demolition of broken / loose PCC for taking down old plaster upto 8 mtr height. Note : Reinforcement will be measured and paid separately.
M&L for TMT bars 6 to 8mm dia cut to length, bent to shape required including cracking bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia.
M&L for brickwork with fly ash bricks, straight or curved on plan exc. 6m mean radius, built in cement mortar 1:6.
Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc built in cement mortar .
M&L for rendering 15 mm thick on internal surfaces of other than fair faces of brick work in cement mortar 1:6 finished even and smooth without using extra cement.
M&L for rendering in two coats with first coat of 10mm thick in CM 1:4 and second coat of 5mm thick duly mixing water proofing compound in CM 1:4 on other than fair faces of brick work or concrete surfaces finished fair and even without using extra cement. Note: Supply only WPC shall be measured and paid separately.
Supply only Liquid water proofing compound (ISI marked) of approved make.
M&L for post construction anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia. holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed by the Engineer-in-Charge.
M&L for treating the soil under plinth protection @ 5 ltrs of emulsion per Sqm of surface area .
M&L for post construction anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron .
M&L for preparation of new plastered surfaces of walls and applying two coat of plastic emulsion over a coat of primer on internal surfaces of wall .
M&L for complete removal of existing treatment of walls and applying two coat of plastic emulsion over a coat of primer on internal surfaces of walls .
M&L for preparation of new external surfaces of walls and applying two coats of cement based paint over a coat of primer on external surfaces of walls .
M&L for preparation of old decorated surfaces of external surfaces and applying one coat of cement based paint .
M&L for preparation of old wooden surface of any description not otherwise described and exc 10cm width or girth applying one coat of synthetic enamel paint first grade quality .
M&L for preparation of new asbestos surface of any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint first grade quality over a coat of pink primer on ceiling.
M&L for applying one coat of aluminium paint including preparation of old steel surfaces over 10 cm width or girth, .
M&L for applying one coat of synthetic enamel paint including preparation of old steel surfaces over 10 cm width or girth, .
M&L for preparation of old plastered surfaces of ceiling and applying one coat of plastic emulsion paint .
M&L for preparation of old plastered surfaces of ceiling and applying one coat of cement based paint .
M&L for grouting of column, beam and any RCC surface etc with cement slurry by mixing 50 kg of cement with 18 to 22 litre of water with admixture of FOSROC CEBEX 100 (Plasticized expanding grout admixture) about 225 gms per 50 kg of cement by drilling upto 12 mm dia hole in the surface @ 300 mm C/C upto 60 mm depth and grouting / pumping the grout with mechanically powered grout mixer upto 10 kg for each hole as per manufacturer‘s instructions and sealing the hole after grouting (GROUT = WATER + CEMENT + FOSROC CEBEX 100 in proportion) complete all as specified and as directed by the Engineer-in-Charge.
M&L for insulation with 50 mm thick glass wool of density 25/ Cum for insulation laying and properly fixing over false ceiling .
Taking down existing roof treatment including plaster etc.
M&L for rendering 15mm duly mixed with water proofing compound in CM 1:4 on fair faces of brick work or concrete surfaces finished smooth and even without using extra cement. Note: Supply only WPC shall be measured and paid separately.
M&L for normal water proofing treatment on roof slab portion consisting with the following operation : (i) Cleaning surface by wire brushes broom, removing dust and applying with bitumen primer conforming to IS 3384-1986 @ 0.50 kg per sqm (ii) Applying a tack coat of bitumen 85/25 @ 1.2 kg per sqm for water proofing membrane (iii) Applying of polymeric water proofing membrane weight not less than 3 kg per sqm over entire area with overlapping and sealed complete all as specified and as directed. (iv) Again applying hot bitumen 85/25 @ 1.2 kg per sqm over water proofing membrane (v) Applying a bituminous aluminium primer/ paint 0.10 kg per sqm .
Dismantling floors, hearth or wall tilling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as directed.
Taking down chowkats or frame with shutter, (without taking off shutter from the frame) exc 1.5 Sqm but n.exc 4sqm each and removing from site complete all as specified and as directed.
Demolition of Brick work or stone boulders masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed
M&L for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4.
M&L for Reinforced Cement Concrete, 1:1.5:3, type A1 (Using 20mm graded granite stone aggregate) as in slabs supported on walls, beams, and columns in floors, roofs, landings, balconies, canopies, deck slab and shelves and the like etc.
M&L TMT bars 10mm dia and over, as reinforcement. cut to length, bent to shape required including cranking bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified.
S&F 2nd class hard wood (well seasoned) plain, solid, straight, chowkats and frame, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified.
S&F for 35mm thick 2nd class hard wood factory made plain framed, panelled shutter (any number of panel) with panels of timber flat on both sides (feather edge) or of veneered particle board medium density with commercial veneering on both faces and size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated .
M&L 18/ 19 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including teak wood lipping 6mm thick all round complete all as specified and as directed.
S&F Continuous (Piano) hinges mild steel, bright finish or electrogalvanised with width of flaps 30mm when opened complete all as directed.
S&F 125mm size MS butt hinges medium weight cold rolled fixed to frame complete all as directed.
M&L 200 mm long , aluminium alloy barrel tower bolts anodised extruded section ISI marked complete all as specified.
M&L 100 mm long , aluminium alloy barrel tower bolts anodised extruded section ISI marked complete all as specified.
S & F 150mm size aluminium handles, cast type, anodised complete all as directed.
S & F 100mm size aluminium handles, cast type, anodised complete all as directed.
S&F 300mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and as directed.
S&F Hasp and staple aluminium anodised 100mm safety type with mild steel hinge pin including bolt to hinge plate and fixed with screw complete all as specified and as directed
M & L 25 mm thick cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in sub base of floors complete all as specified and as directed.
M&L for acid resistant tiles 15 mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors over screed bed of 15 mm thick in CM 1:4 for laying floor finishes
M&L for acid resistant tiles 15 mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in vertical surfaces over backing coat of 10 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces
M & L for Non skid/ matt finish ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 Sqm (400 mm x 400 mm) (Ist quality) as in floor set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 15mm thick screed bed in CM 1:6 finished even and rough complete all as specified and as directed.
M & L for glazed ceramic coloured tiles 300 x 450 x 8mm thick (Ist quality) as in vertical surface such as skirting/dado set in neat cement slurry and pointed in coloured cement to match the surface, including 10mm thick rendering to receive tiles in CM (1:3) finished even and rough complete all as specified and as directed.
M&L 20 mm thick granite (of any type) work table rubbed and polished as in floors and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over a screed bed of 20 mm thick in CM 1:4 complete all as specified.
Fixing only 20 mm thick granite (of any type) work table rubbed and polished in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over a screed bed of 20 mm thick in CM 1:4 complete all as specified.
M&L for 20 mm thick granite (of any type) work table rubbed and polished as in skirting/ dado and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over a backing coat of 10 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces complete all as specified.
M & L for designer rubber moulded chequered cement concrete tiles 30 cm x 30cm x 25 cm thick conforming to IS-13801-1993 with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors including 20mm thick screed bed in cement mortar (1:4) complete all as specified and as directed
M & L rendering 10mm thick on fair faces of brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces in CM 1:3 and finished even and fair with out using extra cement complete all as specified and directed by the Engineer-in-Charge.
S&F framed work such as grills, grating, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L for 8 mm thick transparent acrylic sheet fixed with angle frame.
M&L for preparation of old plastered surfaces of ceiling and applying one coat of white wash, complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of new treated surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by the Engineer-in-Charge.
M&L for one coat of oil bound distemper including preparation of old treated wall surfaces complete all as specified and as directed
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
M&L preparation of new wooden surface of any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint first grade quality over a coat of pink primer, complete all as specified and as directed.
M & L applying two coats of synthetic enamel paint over a coat of red oxide Zinc chromate primer including preparation of new steel surfaces over 10cm width or girth complete all as specified and as directed.
S&F three layer PP-R (Polypropylene random copolymer) pipes of outer dia 20 mm bore pipes SDR 7.4 & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.
S&F three layer PP-R (Polypropylene random copolymer) pipes of outer dia 25 mm bore pipes SDR 7.4 & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.
S & F 15 mm dia bib tap fancy type, cast copper alloy chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule all as specified and as directed.
S & F in repair 15mm dia stop valve cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed
S & F in repair Brass chromium plated shower rose 125 mm size with or without swivel joints including fixing to steel pipe or union complete all as specified and as directed.
S&F PP-R gate valves (brass insert) suitable for 25mm bore PP-R pipe including connection & testing complete all as specified and as directed.
S&F 100 mm dia cast iron (sand cast) ISI marked soil waste and vent pipe (sand cast) any length with or without ears with cement joints , laid in trenches or in floor/wall including necessary earth work, PCC bedding and haunching in below ground level or in floors or fixed to walls with clamps etc complete all as specified and as directed.
S&F 100mm dia cast iron bend (sand cast) ISI marked complete all as specified and as directed.
S&F 100 mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) complete all as specified and directed by the Engineer-in-Charge.
S&F 50mm dia. PVC waste pipes for WHB/sink fixed to walls including fittings and connecting to multiple floor trap complete all as specified and as directed by the Engineer-in-Charge.
S&F grating doom 125mm dia. with waste hole of PTMT (Min weight 40 gms) complete all as specified and as directed by the Engineer-in-Charge.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 100 mm to 160 mm dia pipe complete all as specified and as directed.
Use and waste of formwork to soffits of suspended slab such as roof slabs floor slab, landing and similar work not exceeding 200mm thick (Horizontal or sloping) in flat rough finished surface at concrete complete all as specified and as directed.
M&L for pipes galvanised medium grade including fittings of dia 25 mm complete all as specified and as directed.
M&L for pipes galvanised medium grade including fittings of dia 50 mm complete all as specified and as directed.
S & F rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) Conforming to IS 12701-1996 hoisted and fixed in position 500 ltrs capacity complete all as specified in SSR Part I complete all as specified and as directed.
Supply and fixing gun metal, globe or gate valve of size 25 mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
Supply and fixing gun metal, globe or gate valve of size 50 mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for 25mm dia iron pipe and fixed (Minimum weight 455 gm) complete all as specified and as directed.
M&L for cutting steel tubing of existing GI pipe line 50 mm bore for alternation and addition complete all as specified and as directed.
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, FRLS cable etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft /loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in soft /loose soil complete all as specified and as directed.
Removing excavated soil from site to a distance n.exc 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Taking down carefully existing aluminium /copper conductor point wiring (light / fan / socket or power point) complete, with all fittings such as switches, socket, regulator, ceiling rose, utility light fittings and lamp holders etc and removing materials from site and making good the disturbed surfaces of walls roof and floor etc as per existing specification .
Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and fan regulators etc. for reuse at site. (Note : To be measured only when found serviceable in all respects complete for reuse)
M&L for surface point wiring complete with 1.5 Sqmm PVC insulated unsheathed FRLSH cable multi stranded copper conductor 1100 volt grade flameproof conforming to IS drawn through and including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed in surface of wall/ ceiling/ floors etc for flameproof application connected upto light fittings/ fan with 1.5 mm dia copper earth wire for earth continuity conductor and connection to common earth dolly and to be terminated for one light point controlled by one 5 Amp one way switch including testing on completion.
All as per Srl Item No. 101 here-in-before but for One ceiling fan/ exhaust fan/ wall mounted fan controlled by one 5 Amp one way switch
M&L for concealed point wiring for One light point controlled by one, one way switch with 1.5 Sqmm (nominal cross-sectional area) FRLS PVC insulated and unsheathed 1100 V grade multi stranded copper conductor single core cable drawn through and including 20 mm PVC conduit with all fittings and accessories including one run of FRLS PVC insulated and unsheathed single core multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity conductor to common earth and earth dolly including new pressed steel sunken boxes readily available (having thickness not less than 1.22 mm for boxes upto a size of 200 mm x 300 mm and beyond that the wall thickness shall not be less than 1.63 mm) concealed type with 2 mm thick bakelite sheet cover for mounting switches, sockets, fan regulator etc including testing.
All as per Srl Item No. 103 here-in-before but for One switch socket outlet point 3 pin 5 A on independent board .
All as per Srl Item No. 103 here-in-before but for one switch socket out let for 15 Amps 3 pin on independent board with 2.5 Sqmm cable and 2.5 Sqmm earth wire .
S&F for switch piano flush button single pole one way 5 amps .
S&F for ceiling rose surface bakelite 65 x 30 mm three terminals .
M&L for surface point wiring complete with 4.0 Sqmm PVC insulated unsheathed FRLSH cable multi stranded copper conductor 1100 volt grade flameproof conforming to IS drawn through and including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed in surface of wall/ ceiling/ floors etc for flameproof application connected upto light fittings/ fan with 4.0 Sqmm dia copper earth wire for earth continuity conductor and connection to common earth dolly and to be terminated for one 3 pin power socket controlled by one 16 Amps one way switch including testing on completion.
M&L for flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 Amp, 250volt, 2P+ earth, CMRI certified.
M&L for surface sub main wiring complete with 2.5 Sqmm PVC insulated unsheathed FRLSH cable multi stranded copper conductor 1100 volt grade flameproof conforming to IS drawn through and including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed in surface of wall/ ceiling/ floors etc for flameproof application connected upto light fittings/ fan with 2.5 mm dia copper earth wire for earth continuity conductor and connection to common earth dolly and to be terminated for flame proof application etc including taking down old unserviceable sub main wiring. (Note : Copper conductor 2 run of 2.5 Sqm + 1 run of 2.5 Sqmm earth wire and one run of MS conduit shall be measured as one unit)
M&L for surface sub main wiring complete with 4.0 Sqmm PVC insulated unsheathed FRLSH cable multi stranded copper conductor 1100 volt grade flameproof conforming to IS drawn through and including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed in surface of wall/ ceiling/ floors etc for flameproof application connected upto light fittings/ fan with 4.0 mm dia copper earth wire for earth continuity conductor and connection to common earth dolly and to be terminated for flame proof application etc including taking down old unserviceable sub main wiring. (Note : Copper conductor 2 run of 4.0 Sqm + 1 run of 4.0 Sqmm earth wire and one run of MS conduit shall be measured as one unit)
S&F for flame proof/ weather proof well glass LED light fitting including tube suitable for 1 x 45 watt LED as per IS 13947 body made out of aluminium alloy LM-6 epoxy painted with guard, reflector, flameproof clear glass along with all accessories prewired CMRI certified and hardware in high tensile with corrosive epoxy grey shade paint fixed to wall/ ceiling including flameproof flexible wire from fitting to terminal point . (Crompton Cat Part No. FWL1315-40-CDL or equivalent as approved by GE)
S&F for flame proof junction boxes LM-6 2/3/4 way suitable for 20 mm dia ERW steel conduit complete certified by CIMFR for Gas group I, IIA & IIB for zone I & II. (Sudhir Cat Part No. JB/OA/104 or equivalent as approved by GE)
S&F for flame proof rotary switch with separate cable terminal box including rubber gasket as per IS 2149, SP 25 Amps, 2 pole, 250 volt ISI marked for ON/ OFF light, made out of aluminium alloy LM-6 marked in high tensile steel with anti corrosive epoxy paint grey shade CMRI certified with cable entries .
S&F for flame proof rotary switch socket and plug combined with separate cable terminal box including rubber gasket as per IS 2149, SP 25 Amps, 2 pole, 250 volt ISI marked for ON/ OFF light, made out of aluminium alloy LM-6 marked in high tensile steel with anti corrosive epoxy paint grey shade CMRI certified with cable entries .
S&F for sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with din rail earth and neutral bar .
S&F for triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 20 Amps.
S&F for MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position .
S&F for flame proof/ weather proof enclosure for MCB DB including gas cut ring endless Neoprene rubber gasket box size 500 mm x 500 mm x 145 mm with main incomer 63 Amp 4 pole ON OFF Slazer switch- 1 Nos (Door), Door switch 6 Amp SP ON OFF -12 Nos (Slazer Make)- Door, 63 Amp 4 Pole ON OFF MCB Hager make – 01 No (Body), 6 Amp 1 pole ON OFF MCB Hager Make -12 Nos (Body) with wiring and connector.
S&F for flameproof weather proof multi cable entry junction box including gasket kit IP 66 as per IS 2147/1962 ISI marked made out of cast aluminium alloy LM-6, epoxy painted CMRI certified 63 Amp old unserviceable AC flame proof-weather proof enclosure for MCB DB/186 of internal dimension 400 x 400 x 250 mm including taking out old unserviceable junction box.
S&F for air termination vertical type single pointing aluminium rod 12mm dia. and 300mm long complete all as specified and as directed by the Engineer-in-Charge.
S&F aluminium strip 25x3.15mm including insulating blocks, saddle and fixing screws etc fixing arrangement for all earthing connection by each other .
S&F for test point terminal box made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia. 25m long hexagonal head screw complete all as specified and as directed by the Engineer-in-Charge.
M&L for earthing complete with 7.5m CI pipe 80 mm dia with flanged ends, centrifugally cast, class A, in any length, joints with stainless steel nuts and bolts and sufficient slot upto 2.5 mtr length buried directly and preferably vertically in ground with top flanged ended 2.5 mtr below ground level welded/ connected with GI strip 32 x 6 mm size on the top edge of the flange to bottom edge of the flanged for earthing including filling the pit with charcoal common salt surrounding the earth pipe including drilling 400 mm dia bore any strata of soil to lower the CI pipe complete including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick precast RCC (1:2:4) type B-1 cover slab and necessary testing on completion complete all as specified and as directed.
M&L for point wiring complete with 4.0 Sqmm PVC insulated unsheathed FRLSH cable multi stranded copper conductor 1100 volt grade flameproof conforming to IS drawn through and including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed in surface of wall/ ceiling/ floors etc for flameproof application connected upto light fittings/ fan with 4.0 mm dia copper earth wire for earth continuity conductor and connection to common earth dolly for 16 Amp socket on independent board.
M&L for concealed sub main wiring complete with 6.0 Sqmm PVC insulated unsheathed FRLSH cable multi stranded copper conductor 1100 volt grade flameproof conforming to IS drawn through and including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed in surface of wall/ ceiling/ floors etc for flameproof application connected upto light fittings/ fan with 6.0 mm dia copper earth wire for earth continuity conductor and connection to common earth dolly and to be terminated for flame proof application etc including taking down old unserviceable sub main wiring. (Note : Copper conductor 2 run of 6.0 Sqm + 1 run of 6.0 Sqmm earth wire and one run of MS conduit shall be measured as one unit)
M&L for concealed sub main wiring complete with 10.0 Sqmm PVC insulated unsheathed FRLSH cable multi stranded copper conductor 1100 volt grade flameproof conforming to IS drawn through and including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed in surface of wall/ ceiling/ floors etc for flameproof application connected upto light fittings/ fan with 10.0 mm dia copper earth wire for earth continuity conductor and connection to common earth dolly and to be terminated for flame proof application etc including taking down old unserviceable sub main wiring. (Note : Copper conductor 2 run of 10.0 Sqm + 1 run of 10.0 Sqmm earth wire and one run of MS conduit shall be measured as one unit)
Supply and fixing LED light fitting 2 x 16 Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. (Crompton Cat Part No. EXTN1LT8-16/20 or equivalent as approved by GE)
S&F for flame proof rotary switch with separate cable terminal box including rubber gasket as per IS 2149, SP 16 Amps, 2 pole, 250 volt ISI marked for ON/ OFF light, made out of aluminium alloy LM-6 marked in high tensile steel with anti corrosive epoxy paint grey shade CMRI certified with cable entries .
S&F flame proof Exhaust fan wall mount type 300 mm sweep metal body Heavy duty , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6) all as specified and as directed.
S&F flame proof Exhaust fan wall mount type 450 mm sweep metal body Heavy duty , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6) all as specified and as directed.
S&F wall/ ceiling mounted carbon steel modular type automatic fire extinguisher, 5 Kg ABC type, modular, bulb temperature 68 degree celcious, test pressure 30 Bar.
S&F for sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , triple pole and neutral (TPN) 240 Volt , double door, suitable for 4 way with din rail earth and neutral bar .
Supply and fixing MCB Four Pole (FP) C curve 10kA breaking capacity of 63 amps, 415 Volts in proper position all as specified and as directed.
SWATHI CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .