7 Jun 2022, 6:00 pmClosed
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum-06
As per tender documents
2022_MES_523203_1
GE (ARMY) TVM 9448/E8
Open Tender
Civil Works
Item Rate
180 days
Trivandrum
As per NIT
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹36,040
Yes
28 Jun 2022
10 May 2022
14 Jun 2022
11 May 2022
7 Jun 2022
24 May 2022
Amount
Excavation in trenches not exc 1.5m wide and n.exc 1.5 m in depth for foundation, etc or for shafts, wells cesspits manholes, pier holes, etc not exceeding 10 Sqm in plan and n.exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware , AC or reinforced concrete, PVC ) set in cement mortar of 100/110mm dia pipe complete all as specified and directed.
All as per item No 2 here-in before but size 150/160mm
Taking down PVC pipes including all fittings with spigot and socket ends or rubber gasket joint of size 75/80mm bore complete all as specified and directed.
All as per item No 4 here-in before but size 100/110mm
Material and labour for excavation over areas, n.exc 1.5 mtr deep and getting out in hard and dense soil complete all as specified and directed.
All as per item No 6 here-in before but exc 1.5 mtr and n.exc 3 mtr in depth
Material and labour for Plain cement concrete 1:4:8 type D2 (40 mm graded stone aggregate) as in foundation of manhole including necessary form work complete all as specified and directed.
Demolition of brick/block masonry work built in cement mortar and removing the debris/rubbish to a distance n.exc 100m complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level ) complete all as specified and directed..
Material and labour for pre-cast cement concrete block masonary type C1, 1:3:6 (using 20mm graded stone aggregate) with solid blocks exc. 10 cm in width and setting in CM 1:6 complete all as specified and directed.
Material and labour for cement concrete 1:2:4 type B1 ( using 20 mm stone graded aggregate) in , copings, haunching and benching the like including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed .
Material and labour for precast cement concrete type B1 1:2:4 type B1 (20mm stone graded stone aggregate) as in Manhole / Gully trap cover slab including use and waste of necessary form work set in CM 1:4.etc complete all as specified and directed.
Supply and fix TMT bar 6 mm to 8 mm dia cut to length bent to shape required, including cranking, bending, spirally for hooping for column hooking ends and binding with and including mild steel steel wire (annealed ) not less than 0.90 mm dia or seccuring with clips complete all as specified and directed.
Material and labour for rendering 10 mm thick in cm 1:3 on brick or concrete surfaces finished even and smooth without using extra cement by using WPC @ 3% by wt of cement complete all as specified and directed. Note- WPC will be measured and paid separately.
Supply only integral water proofing compound .
Returning filling in including spreading leveling watering & well ramming in layers in hard/dense soil complete all as specified and directed.
Removing excavated materials to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point as specified and directed
Supply and lay PVC(SWR) Pipe single sockted, in any length with rubber ring joints laid in trenches or in floors 100/ 110 mm dia bore of pipe incl fittings , ISI marked all as specified and directed
All as per items No-20 here-in-before but 150/160 mm dia of pipe.
Supply and fix PVC (SWR) Pipe single sockted, in any length with rubber ring joints and fixed to Walls 110 mm dia bore of pipe incl fittings , ISI marked all as specified and directed.
All as per items No-22 here-in-before but 75 mm dia of pipe.
M&L for Concrete bed for drain pipes 100/110 mm dia including forming cradles by using PCC (1:3:6) type C2 using 40 mm graded stone aggregate including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
All as per items No-24 here-in-before but 150/ 160 mm pipe.
Removing man hole cover including earth soil spread over the cover if any from the frame of septic tanks and receiving chambers remove all night soil, sediments waste materials from any size etc irrespective of its height clear off upto the bottom floor and dispose off the materials out side of MD land from the septic tank to pit suitably excavated to deposit night soil and placing back the main hole cover to its orignal position and including removing all vegetable roots if any and making good surrounds complete all as directed.
All as per item No-26 here-in-before but for manhole of any size, depth of manhole not exceeding 1.5 mtr.
All as per item No-26 here-in-before but for manhole of any size, depth of manhole exceeding 1.5mtr and not exc 3.00 mtr
Cleaning of SGSW / PVC pipe sewage line 100 / 110 mm dia by mechanically and removal of foreign materials complete all as specified and directed.
All as per ser item No-29, here-in-before but bore of pipe 150 / 160 mm.
Cutting into existing manhole for connecting new drain, making good pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 sec ) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 100/110 mm /160mm dia complete all as specified and directed.
Removal of sewage block in manhole gully trap or similar locations including necessary cleaning mechanically or by suitable means as prdered / required to remove block of any type as directed by the Engineer-in-Charge.
Material and labour in repair for PVC (SWR) Gully trap 110 mm dia setting and jointing with solvent cement complete all as specified and directed.
Supply & Fix in repair PVC (SWR) bend 75 mm dia.
Supply & Fix in repair PVC (SWR) bend with access door 75 mm dia.
Supply & Fix in repair PVC (SWR) bend 110 mm dia.
Supply & Fix in repair PVC (SWR) bend with access door 110 mm dia.
Supply & Fix in repair PVC (SWR) 'Y' junction with 75 mm dia.
Supply & Fix in repair PVC (SWR) 'Y' junction with 110 mm dia.
Supply & Fix in repair PVC (SWR) junction single ( single T) equal or unequal 75mm dia
Supply & Fix in repair PVC (SWR) junction single ( single T) equal or unequal 100/110 mm dia
Supply & Fix in repair PVC (SWR) vent cowl 75 mm dia.
Supply & Fix in repair PVC (SWR) vent cowl 100/110 mm dia.
Supply and fix in repair PVC (SWR) floor trap with CP grating including jointing with solvent cement of 75 mm dia fixing with PCC 1:2:4 type B1 complete all as specified and directed.
Cutting holes into or through brick walls built in cement mortar or cement lime for fixing hold fast /pipe etc depth of cutting exceeding half brick work but not exceeding one brick work. complete all as specified and directed.
Dismantling floor , hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Material and labour for Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles each tile exceeding 0.06 sqm but not exceeding 0.11 sqm,, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Vitreous china squatting pan water closet, orissa pattern, size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, provn of lime concrete and jointing to flush pipe (fixed in repair), complete all as specified and directed .
Supply and fix in repair stack clamps 50mm x 5mm flat iron round including bolts and nuts for fixing of pipe any size dia upto 110mm and securing ends of stays to wall etc complete all as specified and directed.
SHILPA ENGINEERS AND CONTRACTORS
M/s G.Ramachandran
General Engineering and Constructions
AKASH CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .