| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.9 LAccepted-AOC GARIKHANA BARAKAR ROAD PURULIA P S PURULIA TOWN DIST PURULIA PIN 723101 | PURULIA | PURULIA | WEST BENGAL | 723101 | L1 | Accepted-AOC lowest | |
| 2 | L2₹90.9 L+₹2.0 L (2.25%)Rejected-AOC NAMOPARA PURULIA | PURULIA | PURULIA | WEST BENGAL | 723101 | L2 | Rejected-AOC 2nd lowest | |
| 3 | L3₹91.5 L+₹2.5 L (2.85%)Rejected-Finance 18 SANKAR BOSE ROAD KOLKATA | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
27 Jul 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer, PMD,PHE.Dte
Office of the Executive Engineer Purulia Mechanical Division,PHE.Dte Ranchi Road,Purulia.
Supply delivery and installation of centrifugal pumping machineries with necessary substitutes with allied works for augmentation of Bandwan PWSS under PMD, PHE Dte. in the District of Purulia.
2022_PHED_387703_6
07 / EE/PMD/PHED OF 2022-2023
Open Tender
MECHANICAL
Item Rate
60 days
Purulia
Please refer Tender documents.
6 documents required · 6 mandatory
₹1.9 L
Yes
22 Sept 2022
30 Jun 2022
29 Jul 2022
5 Jul 2022
27 Jul 2022
5 Jul 2022
Amount
PART A
Supply and delivery at site horizontal split casing centrifugal pump set capable of discharge against total head and mounted RCC base plate coupled with squirrel cage induction motor operated on 415V, 3 split phase + 10% , 3 phase 50 hz AC supply having speed 1475 rpm ( pump and motor design approved by the depertment ) with supply of all accessories to complete the pumping operation. Description and parameters of the pump . Head- 25 mtr Discharge- 175 cum per hour (stage- 1) 1480 rpm and Motor- 18.5 kw (MOC, Test Certificate, warranty certificate along with charcteristic curve to be produced at the time of delivery ) (Meterial should be supplied after taking the approval from the dept at the time of delivery ) (All routine test to be performed in presence of EIC before delivery ). [At new H.L pump house existing cwr to new cwr.] ( 1W +1SB) Details specification as per SOQ
Supply and delivery at site 150 mm dia, P.N.-1.0 Non rising sluice valve . Details specification as per SOQ (Pump & common header)
Supply and delivery at site 150 mm dia, P.N.-1.0 NRV. Details specification as per SOQ
Supply and delivery at site 150 mm dia, P.N.-1.0 Cast iron cast iron wafer type Butterfly Valve.Details specification as per SOQ
Supply & delivey at site Pessue gauge (H. Guru/Febig) 150 mm dia (0-12kg/Sq cm) brass cocok and fitting complete (This cost includs 15 mm dia GI pipes and specials)
Supply & delivey and storage at site ERW/ medium pipe indivudial pump suction and individual pupm delivery line from pump discharge and upto common delivery header Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of TATA make (heavy quality) as per standard specification, 5 mm thick. Suction line 150 mm dia
Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of TATA make (heavy quality) as per standard specification, 5 mm thick. Delivery line and common hader line150 mm dia
Supply and delivery at site of 1.1KV grade 16 sq mm XLPE insulated 3 core armoured copper cable as per IS 7098 Part-1 Details specification as per SOQ
Supply and delivery at site horizontal split casing centrifugal pump set capable of discharge against total head and mounted RCC base plate coupled with squirrel cage induction motor operated on 415V, 3 split phase + 10% , 3 phase 50 hz AC supply having speed 1475 rpm ( pump and motor design approved by the depertment ) with supply of all accessories to complete the pumping operation. Description and parameters of the pump . Head- 75 mtr Discharge-80 cum per hour (stage-1 ) 1480 rpm and Motor-30KW (MOC, Test Certificate, warranty certificate along with charcteristic curve to be produced at the time of delivery ) (Meterial should be supplied after taking the approval from the dept at the time of delivery ) (All routine test to be performed in presence of EIC before delivery ). [At new H.L pump to OHR site ] ( 1W +1SB) Details specification as per SOQ (One no puum is operational )
Supply and delivery at site 100 mm dia, P.N.-1.0 Non rising sluice valve . Details specification as per SOQ
Supply and delivery at site 100 mm dia, P.N.-1.0 NRV. Details specification as per SOQ
Supply and delivery at site 100 mm dia, P.N.-1.0 Cast iron cast iron wafer type Butterfly Valve.Details specification as per SOQ
Supply and delivery at site 150 mm dia, P.N.-1.0 Non rising sluice valve . Details specification as per SOQ
Supply & delivey at site Pessue gauge (H. Guru/Febig) 150 mm dia (0-12kg/Sq cm) brass cocok and fitting complete (This cost includs 15 mm dia GI pipes and specials)
Supply & delivey and storage at site ERW/ medium pipe indivudial pump suction and individual pupm delivery line from pump discharge and upto common delivery header Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of TATA make (heavy quality) as per standard specification, 5 mm thick. Suction line 100 mm dia
Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of TATA make (heavy quality) as per standard specification, 5 mm thick. Delivery line 100 mm dia
Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of TATA make (heavy quality) as per standard specification, 5 mm thick. common hader line150 mm dia
Supply and delivery at site of 1.1KV grade 25 sq mm XLPE insulated 3 core armoured copper cable as per IS 7098 Part-1 Details specification as per SOQ
Supply and delivery at site horizontal split casing centrifugal pump set capable of discharge against total head and mounted RCC base plate coupled with squirrel cage induction motor operated on 415V, 3 split phase + 10% , 3 phase 50 hz AC supply having speed 1475 rpm ( pump and motor design approved by the depertment ) with supply of all accessories to complete the pumping operation. Description and parameters of the pump . Head- 80 Discharge- 15 cum per hour (stage-1 ) 1480 rpm and Motor- 5.5 KW (MOC, Test Certificate, warranty certificate along with charcteristic curve to be produced at the time of delivery ) (Meterial should be supplied after taking the approval from the dept at the time of delivery ) (All routine test to be performed in presence of EIC before delivery ). [for backwash ] ( 1W +1SB) Details specification as per SOQ
Supply and delivery at site 150 mm dia, P.N.-1.0 Non rising sluice valve . Details specification as per SOQ
Supply and delivery at site 100 mm dia, P.N.-1.0 NRV. Details specification as per SOQ
Supply and delivery at site 100 mm dia, P.N.-1.0 Cast iron cast iron wafer type Butterfly Valve.Details specification as per SOQ
Supply and delivery at site 100 mm dia, P.N.-1.0 Non rising sluice valve . Details specification as per SOQ
Supply & delivey at site Pessue gauge (H. Guru/Febig) 150 mm dia (0-12kg/Sq cm) brass cocok and fitting complete (This cost includs 15 mm dia GI pipes and specials)
Supply & delivey and storage at site ERW/ medium pipe indivudial pump suction and individual pupm delivery line from pump discharge and upto common delivery header Supply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of TATA make (heavy quality) as per standard specification, 5 mm thick. Suction line 150 mm dia
Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of TATA make (heavy quality) as per standard specification, 5 mm thick. Delivery line 100 mm dia
Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of TATA make (heavy quality) as per standard specification, 5 mm thick. common hader line150 mm dia
Supply and delivery at site of 1.1KV grade 25 sq mm XLPE insulated 3 core armoured copper cable as per IS 7098 Part-1 Details specification as per SOQ
Supply delivery of Air blower and motors (1 W +1 SB ) with all valves and pipes at suction, delivey , and common header , MCC details specification as per SOQ of NIT.
Supply and delivery at site of 1.1KV grade 16 sq mm XLPE insulated 3 core armoured copper cable as per IS 7098 Part-1 Details specification as per SOQ
Supply & delivery of MCC panel with compartment wise construction ;floor mounted made of sheet steel fabricated 2mm,indoor type, dust vermin proof,IP-54degree protection CPRI approved, powder coated painted with rubber gaskets cover, front lockable hinged door,Elctrolytic grade tinned copper busbar fittings complete with all switchgear and other items duly wired up, TPN electrolyte grade LT panel on frp insulators, detachable gland plate at bottom and tested as per specification.(SOQ attached) at high lift pump house.
Installation testing and commissioning of centrifugal pumping machinery with backwash pumps , air compressor by Dismantling of the existing not functioning pump motor set ( if needed) with connection of all cable making masonry RCC pump motor base foundation, suction line, delivery line, common header, including supply of all erection materials, pipe support, reducer, enlarger, expansion joint, valve support, earthing materials, cable tray etc. as required. Laying of cable, connection with MCC panel of centrifugal pumping machineries, air compressor, back wash pupms and other electrical items , and cable connection from CWR site pump house to submersible pump house with supply of gland & other and completion as per direction of EIC and IE rules to complete net finishing of the whole installation. Rate is including hire charges of Generator, welding set, fuels, lubricants & Gland to complete the job as per relevant IS. Installation and commissioning of above mentioned MCC Panel by making required size masonary cable trench and necessary foundation with supplying required no. compression gland, socket, cable lug, MS chequers sheet, channel ,angle earthing 50mm x 6mm GI stripe for earthing connection etc. by expert electrician and electrical supervisor to complete the job upto satisfaction of EIC. Double earthing should be provided in all equipments (including All pumps motors) connected with 400± 10% volt and single earthing should be provided in rest of all equipments. (Including connection of common header with the raising main by necessary all erection materials, pipe support, reducer, enlarger, expansion joint, valve support. (Any item or accessories not considered in the specification but required to complete the entire installation and operation shall have to be supplied and installed. No extra charge shall be provided for this purpose.
Excavation of earth for installion of earth electrode and filling and ramming a)for soft soil
Earthing with 65mm dia GI pipe (tata-medium)x3.0Mts. long and 50x6mm galvanised(Hot dip) steel strip(4mtr long) standard GI(Hot Dip) wire,20mm dia x 125mm long galvanized bolt,double nuts ,double washers including finishing both ends by making holesetc. and S&F 65mm dia GI pipe(ISI-medium) protection (3Mts)longto be filled with bitumen partly under the ground level; and partly above ground level to an average depth 3.65mtrs.
supply and fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 6mm on wall having clearence of 6mm from wall including providing drilled holes on the busbar complete with GI bolts,nuts,washers with earthing
Extra for providing masonery enclosure on the top of the earth electrode of over all size 86.36 cm x 86.36 cm x 46 cm deep ( below the ground level ) complete with cemented bricks work (1:6) of 25 cm width duly plasterd with cement morter (inside) CI hinged inspection cover size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos 12 mm dia holes on the GI pipe.
Add GST @12%
COMBINE ENTERPRISES
M.S. ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .