Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹69.1 L
EMD Value
₹1.4 L
Closing Date
26 Nov 2026, 5:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Karnataka Power Transmission Corporation Limited
MRS SHAHANNUM ARA
In order to minimise the reactive power.
KPTCL/2026-27/SS/WORK_INDENT4354
KPTCL/2026-27/SS/WORK_INDENT4354
Open
Sub-Station
Two Tender Document System(Two Cover)
KPTCL CEE Transmission Zone Office Mysuru
14 documents required · 14 mandatory
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
Should have carried out work of construction of atleast one (01)No. of 33kV class or above voltage class Substation or any additional transformer work in the existing Substation or provided atleast one(01) No. of 33kV class or above voltage class Terminal Bay along with all connected equipments or 11kV Switchgears works or similar nature of work on Total Turnkey or Partial Turnkey basis, in the last 10 years and shall be in satisfactory service for a minimum period of One (1) year prior to the date of submission of the Bid. iThe documentary proof of fulfilling the qualifying requirements in support of 3.2(b) shall be uploaded along with the bid. The bidder shall upload the P.O, LOI/LOA, DWA, Work done certificates, Performance Certificates issued by the end users not below the rank of Executive/Divisional Engineer along with the bid
Tenderers shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by the Government of Karnataka.
The Tenderer/Bidder shall possess valid Super Grade Electrical Contractors License issued by the Government of Karnataka. OR Valid Form J-1 verification letter issued by the Chief Electrical Inspectorate, Govt. of Karnataka to other state Electrical Contractor License Holder for the highest system voltage specified in the tendered work. As on the date of Bid submission and shall upload the same along with other Bidding documents failing which the offer will be rejected.
The Tenderer shall provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years with KPTCL. A history of awards involving litigations against the bidder or any party or JV/Consortium partner may result in rejection of bid
The Tenderer/bidder should not have been Blacklisted/disqualified for non-performance in any of the Government utilities in the past five years as on date of Bid opening. Then in such cases, the offer of the bidder will be summarily rejected
The offer of the Tenderer/bidder is liable for rejection in following cases. Where the zonal Chief Engineers/CEE(T&P)/SEE Tr. Circle have issued notices in respect of ongoing works in the last 6 months as on date of bid submission invoking Risk and Cost clause and where the work is not completed/charged. Where the zonal Chief Engineers/CEE(T&P)/SEE Tr. Circle have issued notices in the last 6 months as on date of bid submission invoking Risk and Cost clause and where the work is completed by KPTCL entrusting it to some other agency. Wherein the works awarded by KPTCL to the Tenderer/bidder has been short closed invoking Clause Nos. 49.7 & 49.8 of Conditions of Contract (Contractors default) then the bidder shall not be eligible if such short closure has been initiated within 6 months prior to the last date of bid submission of this tender. Note However, if the Tenderer/bidder after issue of Risk and Cost notice completes the works successfully and if the same is commissioned (before opening of the bid), in such cases the offer of the bidder would be considered
Restriction on Land Border Sharing- Any Bidder from a country which shares a land with India will be eligible to bid in this tender only if the bidder is registered with the Competent Authority as per the provision of Government Order No. FD455 EXP-12 2020 Bengaluru dated 01.04.2023. Such bidder/Vendor shall meet the eligibility clauses specified in Annexure-XVI & Annexure- XVII of the tender document under the heading Model Clause/ Certificate/ Undertaking. A certificate/self declaration/ undertaking for having read the clauses specified in Annexure- XVI & Annexure- XVII are to be uploaded by the bidder in the priscribed format
Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity is (A x N x1.5 - B). The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent. OR The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be verified and certified by Chartered Accountant Cost Auditor. However, the Bidder has to upload the PO/Work Award copies for existing commitments and on-going works
Bidder to source the supply of equipment/material from KPTCL approved Vendors only as per the revised QR for Vendor registration, available in the KPTCL website i.e., https://kptcl.karnataka.gov.in, Link Tender and Procurement application for Vendor registration. Further, a certificate is to be submitted/ uploaded by the Bidder agreeing to source the equipment/material for the work from the Vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India as specified in Annexure-XVII of the tender document
Valid GST Registration Certificate
PAN Registration Certificate
No diviation Certificate
Tenderers /Bidders shall Achieved in atleast two financial years in the last five years i.e. FY 2021-2022 to 2025-2026 an average annual financial turnover of Rs.69.08Lakhs. Usually not less than the estimated cost for works costing upto Rs. 100Lakhs. Updated to the FY in which the tenders are invited. Financial Turnover of previous years shall be given a weight of 10% per year to bring them to the price level of the FY in which the tenders are invited. Audited Financial statements i.e., Balance sheets, P&L statements, Turnover certificates duly certified by a Chartered Accountant as documentary evidence shall be uploaded.
Liquid Assets and /or availability of credit facilities of not less than Rs.20.72 Lakhs (Credit lines/ letter of credit/ certificates from banks) for meeting the fund requirement etc
₹1,730
₹1.4 L
12 Nov 2026
12 Nov 2026
30 Nov 2026
24 Nov 2026
Combined package for 1-Providing additional 11kV class 2X2.9MVAr Capacitor Banks to 20MVA Power Trf 1&2 at 66/11kV Attigulipura S/s. 2-Providing additional 11kV class 2X2.9MVAr Capacitor Banks 20MVA Power Trf 1&2 at 66/11kV Ramapura S/s. 3-Providing additional 11kV class 1X2.9MVAr Capacitor Bank to 20MVA Power Trf at 66/11kV Sathegala S/s. 4- Providing additional 11kV class 1X2.9MVAr Capacitor Bank to 20MVA Power Trf at 66/11kV Harave S/s on PTK basis and Percentage rate tendering-CALL-2
12.1 kV, 2.9 MVAr Star connected Capacitor Bank: Design, engineering, supply, erection of Capacitor Bank with internal fuses, terminal connector, Neutral CTs & 0.2% series reactors on neutral side wit...
11kV CTs of ratio 400-200/1-1A (Outdoor) set-03 no
11 kV, 3 Core, 240Sq.mm XPLE UG Cable
11kV Heat Shrinkable Outdoor Cable termination kit for 240 Sqmm 3 Core
11kV Heat Shrinkable Indoor Cable termination kit for 240 Sqmm 3 Core
Isolator Structure for mounting 11kV D/B GOS.
11kV ODS structure Column out of 9Mtr long RCC pole for 150 Kgs. Working load for 11kV ODS
Beams out of Galvanised iron channel of size 100 x 50 mm with arrangement for stringing power conductor on 11 kV side. 1B2 4.0 Mtr. long with clamps, bolts and nuts (0.038x14=0.532)
11 kV Isolator, Double Break 400 A, 25 KA capacity with rigid bi-metallic terminal connector suitable for coyote ACSR.
Supply of galvanised Bolts & Nuts different size
Single Tension string of 90KN, Using 2 Units each along with hardware suitable for Drake conductor (596*2+3758=4950)
Single Tension string of 90KN, Using 1 Units each having 1 Disc Tension clamp suitable for coyote conductor (596+1502=2098)
Single Suspension string Using 2 Units of each 11kV 90KN Disc insulator having along with bolted type suspension clamp and hardware suitable for Drake conductor (596*2+2347=3539)
Single Tension string of 90KN, Using 1 Units each having 1 Disc Tension clamp suitable for AAAC Moose Consuctor
Single Suspension string Using 2 Units of each 11kV 90KN Disc insulator having along with bolted type suspension clamp and hardware suitable for AAAC Moose conductor
AAAC Moose conductor
Drake ACSR Conductor
Coyote ACSR Conductor
Pad clamps suitable for Coyote
Fire wedge connector suitable for Drake - Drake
Fire wedge connector suitable for Coyote - Drake
C type wedged clamp suitable for AAAC Moose-AAAC Moose
C type wedged clamp suitable for AAAC Moose-Coyote
Fire wedge connector suitable for Coyote - Coyote
Earth Bond 450 mm Long
19 Core 2.5 Sq.mm.
4 Core 6.0 Sq.mm.
4 Core 2.5 Sq.mm. (PT)
2 Core 6 Sq mm (AC DC)
2 Core 10 Sq.mm (Out door DCDB)
PVC Pipe 150mm dia for control cable
PVC Bend 150 mm dia
DC Distribution box (outdoor type): Supply and fixing of DC distribution box: Having provision extending DC supply to 06 feeders with provision of one I/C of 100 Amps MCCB and 06 O/G of 16 Amps MCB's ...
PT Distribution box (outdoor type): Supply and fixing of PT distribution box: Having provision extending PT supply to 06 feeders with provision of one I/C of 63 Amps MCCB and 06 O/G of 10 Amps MCB's a...
Grounding of equipments by providing cast iron pipe of 100 mm ID 13 mm thickness, 2.75 metres long with 2 part clamp out of G.I. Flat 50 X 6 mm continuously welded alround the pipe using cast iron wel...
Earthing name plates for new earting pits
Multi Function Transducers(MFT)
As per KPTCL Std, Interface: RS-485 Daisy Chain to RTU Com port,wiring: Both 3ph 4wire, supply: self powered, Measuring range voltage: 120%, current: 120%, frequency: 4...
Input Vtg:110V DC, input indicated by LED, input range 110VDC to 140V DC, sourcing Vtg output 48VDC, No of iputs: 12, No of outputs: 8, Source current: 5mA, at output, 8way switch to be p...
Terminal Blocks (knife type)
(8 TB's per Feeder) = (8 X 1 nos = 8)
Current Cable - 2.5 Sq-mm multistrand copper wire for CT termination
(Each color 15mtrs-R-Y-B)
(15mts x 3 x 1 feeder = 45mtr)
Voltage Cable - 2.5 Sq-mm multistrand copper wire for PT termination
(Each color 5mtrs-R-Y-B-N)
(5mts x 4 x 01 feeder = 20 mtr)
Control Cable - 10 Copper core x 1.5sqmm
(From remote contol desk to RTU)
(17mtrs x 1 nos (1 cable for 1 feeders ) = 17 mtrs)
Signal Cable - 10 Copper core x 0.5sqmm
Feeder to Feeder loop=15mtrs x1 nos=15Mtrs
Feeder to Feeder loop=20mtrs x1 nos=25Mtrs
Remote control desk to RTU (for DI)= 15Mtr
1.5 Sqmm Grey wire for interfacing of DI and DO
(20 mtrs for each panel)(20x1=20mtr)
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the size 2.5 sqmm
(80 lugs/panel)
C-type channel of size 50x100x50x6mm
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
(Size: 32mm dia)
CT TB's - 6 nos for each panel
Supply fo different size glands
Combined package for 1-Providing additional 11kV class 2X2.9MVAr Capacitor Banks to 20MVA Power Trf 1&2 at 66/11kV Attigulipura S/s. 2-Providing additional 11kV class 2X2.9MVAr Capacitor Banks 20MVA Power Trf 1&2 at 66/11kV Ramapura S/s. 3-Providing additional 11kV class 1X2.9MVAr Capacitor Bank to 20MVA Power Trf at 66/11kV Sathegala S/s. 4- Providing additional 11kV class 1X2.9MVAr Capacitor Bank to 20MVA Power Trf at 66/11kV Harave S/s on PTK basis and Percentage rate tendering-CALL-2
11KV PCVCB Switchgear: 350MVA, 25kA, 800A Feeder Panel for Capacitor Bank (SCADA Compitable), 200-100/1-1 A CTs and ETV Meter with 0.2 acc class with DLMS
Wiring & assisting in Testing & Commissioning for 11 kV outdoor Switchgear.
Annunciator panel suitable for two capacitor bank panel
11KV MCVCB Switchgear: 500MVA, 25kA, 1250A Feeder Panel for Capacitor Bank (SCADA Compitable), 200-100/1-1 A CTs and ETV Meter with 0.2 acc class with DLMS
Releasing and re-erection of existing Capacitor Bank Breaker
De-Wiring and Wiring & assisting in Testing & Commissioning for 11 kV outdoor Switchgear.
Releasing and re-erection of Capacitor Bank
Releasing & Re Erection of existing HPI mounting structure (0.02 MT per Structure)
11kV CTs of ratio 400-200/1-1A (Outdoor) set-3 no
Assisting in Testing and Commissioning of CT's set-3 no
11kV ODS structure Column out of 9Mtr long RCC pole for 150 Kgs. Working load for 11kV ODS
Beams out of Galvanised iron channel of size 100 x 50 mm with arrangement for stringing power conductor on 11 kV side. 1B2 4.0 Mtr. long with clamps, bolts and nuts (0.038x14=0.532)
Releasing and re-erection of yard light RCC poles
11 kV Isolator, Double Break 400 A, 25 KA capacity with rigid bi-metallic terminal connector suitable for coyote ACSR.
Releasing and re-erection of 400A Double break GOS
11 kV, 3 Core, 240Sq.mm XPLE UG Cable
11kV Heat Shrinkable Outdoor Cable termination kit for 240 Sqmm 3 Core
11kV Heat Shrinkable Indoor Cable termination kit for 240 Sqmm 3 Core
Isolator Structure for mounting 11kV D/B GOS.
Formation of Main Bus/Cross Bus with Single Drake Conductor
Formation of Main Bus/Cross Bus with Single AAAC Moose Conductor
Formation of Cross Bus with Single Coyote Conductor
19 Core 2.5 Sq.mm.
4 Core 6.0 Sq.mm.
4 Core 2.5 Sq.mm. (PT)
2 Core 6 Sq mm (AC DC)
2 Core 10 Sq.mm (Out door DCDB)
Grounding of equipment with 50 x 6 mm G.I. Flat and connecting Equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and conn...
Grounding of equipments by providing cast iron pipe of 100 mm ID 13 mm thickness, 2.75 metres long with 2 part clamp out of G.I. Flat 50 X 6 mm continuously welded alround the pipe using cast iron wel...
Earthing name plates for new earting pits
Supplying & Providing 450 mm dia 450 mm height 1.5" to 2" thick hume pipe collar (non pressure type) for earth pits including all lead and lifts etc.,
Multi Function Transducers(MFT)
As per KPTCL Std, Interface: RS-485 Daisy Chain to RTU Com port,wiring: Both 3ph 4wire, supply: self powered, Measuring range voltage: 120%, current: 120%, frequency: 4...
Input Vtg:110V DC, input indicated by LED, input range 110VDC to 140V DC, sourcing Vtg output 48VDC, No of iputs: 12, No of outputs: 8, Source current: 5mA, at output, 8way switch to be p...
Current Cable - 2.5 Sq-mm multistrand copper wire for CT termination
(Each color 15mtrs-R-Y-B)
(15mts x 3 x 1 feeder = 45mtr)
Voltage Cable - 2.5 Sq-mm multistrand copper wire for PT termination
(Each color 5mtrs-R-Y-B-N)
(5mts x 4 x 01 feeder = 20 mtr)
Control Cable - 10 Copper core x 1.5sqmm
(From remote contol desk to RTU)
(17mtrs x 1 nos (1 cable for 1 feeders ) = 17 mtrs)
Signal Cable - 10 Copper core x 0.5sqmm
Feeder to Feeder loop=15mtrs x1 nos=15Mtrs
Feeder to Feeder loop=20mtrs x1 nos=25Mtrs
Remote control desk to RTU (for DI)= 15Mtr
1.5 Sqmm Grey wire for interfacing of DI and DO (20 mtrs for each panel)(20x1=20mtr)
CT TB's - 6 nos for each panel
Miscellaneous items like, Ferrules, cable ties, insulation tape, & Labour for cutting, weldind, drilling, etc
Configuration of RTU and Engineering along with validation of data at SLDC
Combined package for 1-Providing additional 11kV class 2X2.9MVAr Capacitor Banks to 20MVA Power Trf 1&2 at 66/11kV Attigulipura S/s. 2-Providing additional 11kV class 2X2.9MVAr Capacitor Banks 20MVA Power Trf 1&2 at 66/11kV Ramapura S/s. 3-Providing additional 11kV class 1X2.9MVAr Capacitor Bank to 20MVA Power Trf at 66/11kV Sathegala S/s. 4- Providing additional 11kV class 1X2.9MVAr Capacitor Bank to 20MVA Power Trf at 66/11kV Harave S/s on PTK basis and Percentage rate tendering-CALL-2
11KV PCVCB Switchgear: 350MVA, 25kA, 800A Feeder Panel for Capacitor Bank (SCADA Compitable), 200-100/1-1 A CTs and ETV Meter with 0.2 acc class with DLMS
11KV MCVCB Switchgear: 500MVA, 25kA, 1250A Feeder Panel for Capacitor Bank (SCADA Compitable), 200-100/1-1 A CTs and ETV Meter with 0.2 acc class with DLMS
Releasing and re-erection of existing Capacitor Bank Breaker
12.1 kV, 2.9 MVAr Star connected Capacitor Bank: Design, engineering, supply, erection of Capacitor Bank with internal fuses, terminal connector, Neutral CTs & 0.2% series reactors on neutral side wit...
Combined package for 1-Providing additional 11kV class 2X2.9MVAr Capacitor Banks to 20MVA Power Trf 1&2 at 66/11kV Attigulipura S/s. 2-Providing additional 11kV class 2X2.9MVAr Capacitor Banks 20MVA Power Trf 1&2 at 66/11kV Ramapura S/s. 3-Providing additional 11kV class 1X2.9MVAr Capacitor Bank to 20MVA Power Trf at 66/11kV Sathegala S/s. 4- Providing additional 11kV class 1X2.9MVAr Capacitor Bank to 20MVA Power Trf at 66/11kV Harave S/s on PTK basis and Percentage rate tendering-CALL-2
Earth work excavation for Foundation by manual means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights...
Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, inc...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of appro...
Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plaster...
Dismantling dressed stone work ashlar face stone work, marble work orprecast concrete work manually/ by mechanical means including stackingof serviceable and disposal of unserviceable material to the ...
Jelly Spreading (20-25 mm) : Supplying and providingjelly in the station yard of uniform thickness of 100 mmincluding the cost of materials, labour charges, requiredtools and plants etc., complete.
Providing and laying in position Burnt Bricks as per directions of Engineer In Charge
Providing M-Sand : Supplying and filling in plinth,foundations / UG cable work with approved M-sand
including watering, ramming, consolidating and dressing.The rate includes the cost of material, labo...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Advisory Note.docx
Others - advisory note • 0.01 MB
NIT- 11kV Capacitor Banks - Call-2.doc
Others - NIT • 0.11 MB
Insurance documents.docx
Others - Insurance document • 0.02 MB
Work on Hand details format Tender.doc
Others - works on hand format • 0.06 MB
Section-11kV Capacitor Banks.pdf
Technical Information / Worksheet • 1.00 MB
Circulars and Guidelines_Circulars and Guidelines_Advisory Note.docx
Others - circulars&guidline • 0.01 MB
Circulars and Guidelines_Circulars and Guidelines_Circular for sand.pdf
Others - circulars&guidline • 0.06 MB
Circulars and Guidelines_Circulars and Guidelines_GIS based asset mapping.pdf
Others - circulars&guidline • 0.69 MB
Circulars and Guidelines_Circulars and Guidelines_Insurance documents.docx
Others - circulars&guidline • 0.02 MB
Circulars and Guidelines_Circulars and Guidelines_KPTCL e BG circular.pdf
Others - circulars&guidline • 0.23 MB
Circulars and Guidelines_Circulars and Guidelines_KPTCL Revised stamp duty circular.pdf
Others - circulars&guidline • 0.82 MB
Circulars and Guidelines_Circulars and Guidelines_Vendor approval_Circular for Vendor Approval labaratories for Drawing GTP etc.pdf
Others - circulars&guidline • 0.35 MB
Circulars and Guidelines_Circulars and Guidelines_Vendor approval_Cirular for acceptance of TypeTest of ERDA.pdf
Others - circulars&guidline • 0.07 MB
Circulars and Guidelines_Circulars and Guidelines_Vendor approval_vendor approval Guidelines.pdf
Others - circulars&guidline • 0.95 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_CIVIL Tech specs Ilavala Addnl.doc
Technical Information / Worksheet • 0.18 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_11kV switchgear_11kV swg spec for BMAZ area_Switchgear Rvd MCVCB 31dot 5 MVA.doc
Technical Information / Worksheet • 0.32 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_11kV switchgear_11kV swg spec for BMAZ area_Switchgear Spec Revised MCVCB.doc
Technical Information / Worksheet • 0.33 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_11kV switchgear_11kV swg spec for BMAZ area_Switchgear Spec Revised PCVCB.doc
Technical Information / Worksheet • 0.34 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_DLMS TVM TECHNICAL SPECF.pdf
Technical Information / Worksheet • 18.40 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Earthmat.docx
Technical Information / Worksheet • 0.02 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Instrument Transformer_CT chart New.doc
Technical Information / Worksheet • 0.10 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Instrument Transformer_Section Instrument Transformer.docx
Technical Information / Worksheet • 0.08 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_SCADA Comm.docx
Technical Information / Worksheet • 0.26 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section 11kV CB.doc
Technical Information / Worksheet • 0.25 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section 11KV UG Cable.doc
Technical Information / Worksheet • 0.04 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section 11kV Special GOS.docx
Technical Information / Worksheet • 0.03 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section 20MVA below power transf.docx
Technical Information / Worksheet • 0.19 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section Battery and charger.docx
Technical Information / Worksheet • 0.09 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section C and R Panels.docx
Technical Information / Worksheet • 0.18 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section Circuit Breaker.docx
Technical Information / Worksheet • 0.13 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section Fire protection.doc
Technical Information / Worksheet • 0.10 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section Furniture.docx
Technical Information / Worksheet • 0.02 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section GTR.docx
Technical Information / Worksheet • 0.12 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section Isolator.docx
Technical Information / Worksheet • 0.09 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section Lighting system.docx
Technical Information / Worksheet • 0.08 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section LT Transformer.docx
Technical Information / Worksheet • 0.10 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section LTAC and DC Panel.docx
Technical Information / Worksheet • 0.04 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section Power and control cable.docx
Technical Information / Worksheet • 0.11 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section Structures.docx
Technical Information / Worksheet • 0.03 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section Surge Arrestor.docx
Technical Information / Worksheet • 0.03 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section Switchyard Erection.docx
Technical Information / Worksheet • 0.14 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II A Tech Spec-Station portion_Section T and C.docx
Technical Information / Worksheet • 0.03 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II B Tech Spec- Line portion_SECTION I.docx
Technical Information / Worksheet • 0.07 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II B Tech Spec- Line portion_SECTION II.docx
Technical Information / Worksheet • 0.03 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II B Tech Spec- Line portion_SECTION III.docx
Technical Information / Worksheet • 0.12 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II B Tech Spec- Line portion_SECTION IV and V.docx
Technical Information / Worksheet • 0.08 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II B Tech Spec- Line portion_SECTION IX.docx
Technical Information / Worksheet • 0.05 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II B Tech Spec- Line portion_SECTION VI.doc
Technical Information / Worksheet • 0.44 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II B Tech Spec- Line portion_SECTION VII and VIII.docx
Technical Information / Worksheet • 0.09 MB
Volume 2 A and B Tech Spec_Volume II A & B-Tech Spec(Stn & Line)_Vol II B Tech Spec- Line portion_SECTION X.doc
Technical Information / Worksheet • 0.12 MB
11kV Capacitor bank-Tender.docx
Tender Document • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .