Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹44.1 L+₹83,807.40 (1.94%)Rejected-AOC A T ROAD CHABUA DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L2 | Rejected-AOC NOT L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category of work mentioned in NIT |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
3 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TEZPUR
GE AF TEZPUR,PO SALONIBARI,DIST-SONITPUR,ASSAM
PETTY REPAIR OF VARIOUS E/M INSTALLATIONS IN WSA COMPLEX AT AFS TEZPUR UNDER GE (AF) TEZPUR.
2022_MES_536726_4
GE(AF)/TEZ/8664/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
TEZPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) TEZPUR
₹80,000
Yes
9 Feb 2023
17 Sept 2022
5 Oct 2022
17 Sept 2022
3 Oct 2022
20 Sept 2022
Amount
Providing services for attending breakdown of HT/LT overhead lines, underground cables,Sub stations of the electric supply system with minimum one Electrician (Skilled category of worker) [01(One) Shift of 08 Hours in a day (9 AM to 5.00 PM)] including Sunday & Holidays complete all as specified and directed. Scope of work will include repair/as described in HT/LT overhead lines, underground cables,power house/sub station as under: - (i) Immediate finding of faults wherever in OH/UG of LT/HT supply and distribution system as and when occurred. (ii) On indication of any type of fault/tripping of VCB/HT switch gear, fault/tripping of ACB/LT switch gear, fault/tripping of APFC Panels, MCCBs, MCBs,relays,contactors etc. the contractor shall be responsible to locate the fault and to intimate regarding the fault with in reasonable time (not more than 2 Hours). (iiii) Replacement of LT/HT fuses.(Materials will be supplied by Deptt.) (iv) Restraining of ACSR conductor wherever required including necessary binding complete. (v) Providing T&P as required for rectification of defect/fault to electrification. (Ladder, torch, rubber gloves,safety belt,safety helmet,boot rubber knee and complete tool kit for electrician). (vi) Providing first aid kit (containing items like dressings(02 Sets)dettol/savlon-(02 nos),cotton, adhesive bandages(03 Sets) disposable gloves, antiseptic soaps etc). (vii) To keep area of Power House/transformer surrounding, sub station Bldg, toilet & surroundings of electrical equipments neat and clean. (viii) All types of cleaning viz cleaning of HT/LT panels, warming up (demoisturing) of Bus bar chambers in HT Panels, tightening of connections in HT/LT Panels installed in power house. (ix) The scope will also cover load balancing on each phase of transformer as and when directed by Engineer-in-Charge/JE (x) The contractor shall comply with existing labour laws,IE rules, Factory Act etc. in totality and deptt shall not be held responsible for any lapse. (xi) Maintenance and upkeep of any new equipment if installed during the contract period.
Comprehensive Maintenance of existing HT 11 KV,400/630/800 Amps rating VCBs (Make : Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/Andrew Yule) by removing from housing, overhauling the mechanical parts and periodic maintenance servicing of 11KV indoor/outdoor VCBs, checking of quality of vacuum interrupter, insulation resistances, static contact resistance, testing ( IR value, Ratio Test, Polarity) and connection checking of 11 KV Current Transformer ( Set of Three) by primary injection kit ,testing and calibration of relay ( Set of, Two Over Current and One Earth Fault Relays) by secondary injection kit including,all other functional tests of the VCB panels including for CTs, PTs, complete all as specified and directed. Notes:- (i) The work shall be carried out through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by the Engineer in Charge. (ii) Calibration and Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge. (iii) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
Supply Only, panel indicating lamp fitting, LED type suitable for 110 volt/230 volt AC with base complete all as specified (Make: L&T / Siemens / STS/AE)
Supply Only, Breaker Control Switches,TNC (Trip,Neutral and Close),rating 25 Amps with contact arrangement 1Trip + 1Close, barrel lock mounting type, suitable for 11 KV VCB panels, complete all as specified. (Cat No 73257SEB90PGBB of Make L&T or equivalent Model of Make: Switron / Recom /Kaycee / Areva)
Supply Only, heater with heater switch & thermostat suitable for 11KV VCB panels, 80 watts, as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/Andrew Yule)
Supply Only, HT Current Transformers, single phase indoor solid state (Resin cast) 11 KV, ratio 300/5A, accuracy class 5P10, rated burden 15VA, STC 13.1 KA for 1second,suitable for VCB Panels as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/Andrew Yule)
Supply Only,microprossesor based feeder protection neumerical relay with overcurrent, earth-fault, phase-discontinuity, negative-phase sequence and thermal-overload protections, inrush current detection,reclosing and measurement,preconfigured functionality facilitates, configurable binary inputs/outputs using local HMI or communication interface,modbus and IEC 60870-5-103 protocols supports,universal power supply 24-265 V AC/DC,suitable for 11 KV VCB panels,complete all as specified. (Cat No REJ601 of Make ABB or equivalent Model of Make: Schneider/Seimens)
Supply Only,auxiliary relay with high-speed operation,rated voltage 24Volts DC,operating range - 30% to +10% of rated voltage,frequency 50 Hz +/-5%,pick-up voltage < 80%,Drop-off voltage > 20% ,Pick-up time 20-30ms,contacts 6N/O + 1N/C,suitable for 6.6 KV VCB panels,complete all as specified. (Type PQ8n of Make ABB or equivalent Model of Make: Schneider/Seimens)
Supply Only,Vacuum Interrupter Assembly with Flex connection (R Phase,Y Phase & B Phase) suitable for 11 KV, 630/800 Amps VCB Panels as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/Andrew Yule)
Supply Only base mounting type power pack with capacitor back up unit input voltage 230 V, output voltage 110 Volt DC, stored output 100 W sec, non store output 100W, with mains ON indicator,suitable for 11 KV VCB panels,complete all as specified. [Cat No. “CPP-1-U110-W100” of Make “Alen” or equivalent Model of Make ‘Jyoti/GE’]
Supply Only, fibre panel spout, 12Kv,50/60 Hz,suitable for 11 KV, 630/800 Amps VCB Panels (ABB VD4 11KV Monobloc 1250Amps) as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/Andrew Yule)
Supply Only, Epoxy Body,suitable for 11 KV, 630/800 Amps VCBs (Vacuum Switchgear Type VMX) as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/Andrew Yule)
Supply,installation,testing and commissioning of,auxiliary relay with high-speed operation, rated voltage 24Volts DC,operating range - 30% to +10% of rated voltage,frequency 50 Hz +/-5%,pick-up voltage < 80%,Drop-off voltage > 20% ,Pick-up time 20-30 ms,contacts 6N/O + 1N/C,suitable for 6.6 KV VCB panels,complete all as specified and directed. (Type PQ8n of Make ABB or equivalent Model of Make: Schneider/Seimens)
Supply,installation,testing and commissioning of, Motor with Gear Assembly,110 Volts/230 Volts AC (Make Bosch/ Webtool/Ralliwolf) suitable for 6.6 KV VCBs as per OEM's specifications,complete all as specified and directed. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/Andrew Yule)
Disconnection of existing Air Circuit Breakers (ACBs), 3 Pole/4 Pole,manually/electrically operated, fixed/draw-out type, AC 440 Volts,breaking capacity 50-100 kA, rated current 800-2000 Amps, form all incoming and outgoing electrical connections,checking serviceability of each components viz. ON/OFF button,CTs, tripping coil, shunt trip device,auxillary switches,locking arrangement,safety shutter,arc shield etc., replacement of defective lugs,thimbles etc.,replacement of defective parts, through cleaning of ACB both internally and externally, reassembling of parts including reconnection of all incoming and outgoing electrical connections after repairs,testing and commissioning,complete all as specified and directed. Notes:- (i) The work shall be carried out through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by the Engineer in Charge. (ii) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
Supply Only,Lockable Trip Push Button (LTPB),Type-AA/BB/CC/DD suitable for Air Circuit Breakers (ACBs) as per OEM's specifications,complete all as specified. [Cat No.SL93148OOOA/SL93148OOOB/SL93148OOOC/SL93148OOOD of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Supply Only,Lockable Trip Push Button kit (3 I/C & 2 B/C),suitable for Air Circuit Breakers (ACBs) as per OEM's specifications,complete all as specified. [Cat No.SL91936OOOO of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Supply Only,Locking of ACB in Isolated position (LIP),Type-A/B/C/D,suitable for Air Circuit Breakers (ACBs) as per OEM's specifications,complete all as specified. [Cat No.SL93146OOOA/SL93146OOOB/SL93146OOOC/SL93146OOOD of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Supply Only,Locking of ACB in Any position (LAP),Type-A/B/C/D,suitable for Air Circuit Breakers (ACBs) as per OEM's specifications,complete all as specified. [Cat No.SL93147OOOA/SL93147OOOB/SL93147OOOC/SL93147OOOD of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Supply Only,Racking Interlock,Type-AA/BB/CC/DD,suitable for Air Circuit Breakers (ACBs) as per OEM's specifications,complete all as specified. [Cat No.SL93149OOOA/SL93149OOOB/SL93149OOOC/SL93149OOOD of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Supply Only,Racking Padlock Assembly,suitable for Air Circuit Breakers (ACBs) as per OEM's specifications,complete all as specified. [Cat No.CL90025OOOO of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Supply Only,Door Interlock,suitable for Air Circuit Breakers (ACBs) as per OEM's specifications,complete all as specified. [Cat No.SL93150OOOO of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Supply Only,Mechanical Operation Counter,suitable for Air Circuit Breakers (ACBs) as per OEM's specifications,complete all as specified. [Cat No.XM80837OOOO of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Supply Only,Mounting Kit for Front Mounted Counter,suitable for Air Circuit Breakers (ACBs) as per OEM's specifications,complete all as specified. [Cat No.SL95882OOOO of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Supply Only,Shunt Release (SR),Type EA : 24/48V DC/Type EA : 110V DC/Type EA : 220V DC/Type EA1 : 110V AC/Type EA1 : 240V AC/Type EA1 : 415V AC,suitable for Air Circuit Breakers (ACBs) as per OEM's specifications,complete all as specified. [Cat No.SL92718O4OO/SL92718O1OO/SL92718O2OO/SL92718OAOO/SL92718OBOO/ SL92718ODOO of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Supply Only,Under Voltage Release (UVR),Type MV : 24V DC/Type MV : 240V AC/Type MV : 415V AC,suitable for Air Circuit Breakers (ACBs) as per OEM's specifications,complete all as specified. [Cat No.ST36877OOOO/SL92720BOOO/SL92720DOOO of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Supply Only,Earth Fault Release ( for DN1),Type EF1 (10%, 20% In )/Type EF2 (30%, 40%, 50% In),suitable for Air Circuit Breakers (ACBs) as per OEM's specifications,complete all as specified. [Cat No.SL91340OOOO/SL91341OOOO of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Supply Only,Vertical Terminal Adaptors for Draw out type ACBs (400-1250 S1/800-1000 C) as per OEM's specifications,complete all as specified. [Cat No.SL93281OOOO of Make L&T or equivalent Model of Make Schneider/ABB/Seimens]
Disconnecting incoming, outgoing and earthing lead connections of transformers,250 KVA to 1000 KVA, outdoor/indoor type from 11 KV /433 Volt supply system,carrying out routine yearly maintenance works as per Table-1 of IS:10028 (Part-III) including reconnection of all incoming outgoing and earthing lead connections,testing and commissioning,complete all as specified and directed. Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge. (ii) Spare Parts for replacement, topping up of transformer oil and dehydration & filteration of transformer oil will be measured and paid seperately under respective items of this BOQ here in after.
Supply Only,6mm-8mm thick gasket for top lid cover,HT and LT bushing assembly of 250 KVA to 1000 KVA transformers,as per OEM's specifications,complete all as specified.
Supply Only,Brass spindle, 20 mm dia., with 05 Nos. Nuts, check nuts and washers, ISI Marked (IS: 3347) for bushing assembly of 250 KVA to 1000 KVA transformers,as per OEM's specifications,complete all as specified.
Supply Only,silica gel breather assembly in PVC container with full transparent body, filled with silica gel not less than 0.50 Kg. per container for 250 KVA to 1000 KVA transformers,as per OEM's specifications,complete all as specified.
Supply,filling in, dehydration and filtration of new transformer oil, having dielectric strength not less than 40 KV (rms) with gap of 2.5 mm, conforming to IS: 335, for topping up/ replacement of transformer oil complete all as specified and directed.
Dehydration, filtration, de-sludging of transformer oil of any type, including arrangement of all tools and plants to achieve dielectric strength not less than 40 KV (rms) with gap of 2.5 mm, complete all as specified and directed.
Taking out existing, U/G cables, 11000 Volts grade from trenches/ducts/ poles etc of size 95 Sq. mm 3 Core complete all as directed.
Taking out existing, U/G cables, 11000 Volts grade from trenches/ducts/ poles etc of size 185 Sq. mm 3 Core complete all as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed.
Demolition of cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for,complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for,complete all as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil ,complete all as specified and directed.
Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all asspecified and directed.
Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary from work complete all as specified and directed.
Materials and Labour for brick work with Sub Class ‘B’ bricks straight or curved on plan exceeding 6M mean radius built in cement mortar (1:6),complete all as specified and directed.
Materials and Labour for Pea gravel 10mm size deposited, spread and levelled in layers not exceeding 15 cm thick,complete all as specified and directed.
Supply, laying, jointing and testing of, XLPE insulated, screened, PVC bedded, galvanized steel wire or tape armoured, heavy duty electric cables with aluminium conductor, 11000 Volts (Earthed) Grade, cross sectional area 95 Sq. mm, 3 core, complete all as specified and directed.
Supply, laying, jointing and testing of, XLPE insulated, screened, PVC bedded, galvanized steel wire or tape armoured, heavy duty electric cables with aluminium conductor, 11000 Volts (Earthed) Grade, cross sectional area 185 Sq. mm, 3 core, complete all as specified and directed.
Supply and filling in dry sand in cable trenches before and after the cables are laid, as in sand cushioning to cables complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover,class HV, Type 1, flat, size 300mmx 180mm x 40mm,complete all as specified and directed.
Re-laying old serviceable un-reinforced precast concrete cable cover, in cable trenches, as cable protection complete all as specified and directed. Note:-Old Serviceable cable covers obtained from taking out vide BOQ/Schedule-A Serial Item No. 36 & 37 here in before shall be re-used.
Supply and Laying galvanized steel tubing, 80 mm bore, light grade, in trenches or fixed to poles/Walls etc, for cable protection, complete all as specified and directed.
Supply and Fix,cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm,complete all as specified and directed.
Supply and Fix,cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm,complete all as specified and directed.
Supply and Fix,cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm,complete all as specified and directed.
Materials and Labour for,rolled mild steel plates (plain or chequered),Fe-410 W (Gde E-250) quality B,channels,square cut or notched (ordinary and counter sunk) forming holes,without any attachment, complete all as specified and directed.
Materials and Labour for, rolled mild steel Fe 410-W (Gde-E 250) Quality 'A', in joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated),complete all as specified and directed.
Manufacture,supply and fixing of schematic line diagram board of overall size 2000 mm x 1000 mm,with 6 mm thick, 5 Nos. ply, plywood, grade BWR, type BB, fixed with screws to frame made out of wrought second class hardwood fillets of cross sectional area not exceeding 25 sq cm,including fixing/pasting on plywood surface flex material with computrised printed line diagrams with letters or figures (Block,Roman, Italic or Indian) n exc. 10 cm high and symbols (stops, commas, short lines, dashes,hyphens, brackets, etc.), applying two coats of synthetic enamel paint (ordinary tint) over a coat of pink primer on wooden frame and including taking down existing board,complete all as specified and directed.
Manufacture,supply and fixing of board notice,overall size 1830 mm x 1220 mm complete all as specified and shown in Drawing No. FD-99(M) Dated 27.09.1971, Sheet 1/1,including taking down existing unserviceable notice board. Notes:- (i) The drawing(s) mentioned is not uploaded with the tender documents. These are available in the “Standard Furniture Design Book” issued by Army HQ, E-in-C’s Branch , New Delhi,revised upto date which will be available for reference in all MES offices.The bidder shall be deemed to have seen this drawing(s) before uploading of bid and shall be deemed to have quoted their rates accordingly. (ii) Second class hardwood timber shall be used. All timber shall be of good quality, well seasoned, of natural growth best available, uniform in texture, free from shakes, rot, dot cracks / loose or decayed, knots, brothels, soft spots and other defects and blemished
Materials and Labour for pasting on existing display boards, letters or figures (Block,Roman, Italic or Indian) exc. 5 cm but n exc.10 cm high and symbols (stops,commas,short lines,dashes,hyphens, brackets, etc.) made out of high intensity grade retroreflective encapsulated lens type vinyle sheet,complete all as specified and directed.
Disconnection of existing Star Delta Starter of any capacity, form all incoming and outgoing electrical connections,checking serviceability of each components viz. contactors,overload relay,single phase preventer,indicator lamps etc.,replacement of internal wirings with FRLSH PVC insulated multistranded copper conductor 6.00 Sqmm size and defective lugs,thimbles etc.,replacement of defective parts,through cleaning of Star Delta Starter both internally and externally, reassembling of parts including reconnection of all incoming and outgoing electrical connections after repairs,testing and commissioning, complete all as specified and directed. Note:- Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 12, AC-3 rating 12 Amps and AC-1 rating 30 Amps,auxillary contacts 1 NO/ 1 NC, complete all as specified. [Cat No.CS94108/CS94109 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]
Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 25, AC-3 rating 25 Amps and AC-1 rating 45 Amps,complete all as specified. [Cat No.CS94110 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]
Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 32, AC-3 rating 32 Amps and AC-1 rating 55 Amps,complete all as specified. [Cat No.CS94111 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]
Supply Only,Thermal Overload Relays,Type MN 2,suitable for MNX Contactor,relay range 24 - 40 Amps,complete all as specified. [Cat No.SS94145OOFO of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]
Supply Only,Electronic Timers Type ST 100,240 / 360 / 415V, 50Hz for 3 - 30 seconds, complete all as specified. [Cat No.ST80328OOOO of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]
Supply Only,single phase preventer,SPPR type SDz5, 380V (For MU-G30/40/50/75), with settable Time 'ON' Delay 30 Seconds-5 Minutes, complete all as specified. [Cat No.XM81807OOOO of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]
Excavation of trenches of suitable size,dewatering of trenches,returning filling in after repair work,removing surplus soil including repair to break down of 100mm/150mm dia of CI/DI/MS water pipe line bursting,cracks,joint leakage etc. including cleaning/removal of damaged pipe pieces by gas cutting / manual cutting as per site requirement,inserting necessary specials such as short pieces of pipes (Not exceeding 300 mm in length) as per existing specifications, collars, mechanical joints,lead joints,flanged joints,push on rubber ring joints etc as required,including testing for leakages of joints,complete all as specified and directed. Note: - The quoted rate shall be deemed to inclusive of the following: (i) Earthwork and cutting of existing PCC Path/Hard Standing.However PCC for making good distrubed surface of PCC Path/Hard Standing will be measured and paid seperately. (ii) Pumping arrangement for dewatering of trenches during attending break down. (iii) Qualified tradesmen for attending break downs. (iv) All T&P, Materials and Labour as required. (v) Levelling and alignment of the pipeline. (vi) Restore the damaged portion of pipeline leakage free.
Materials and Labour for,150mm bore MS ERW pipe, heavy grade, with all fittings,laid in trenches including wrapping of pipe with 4 mm thick corrosion resistant tape conforming to IS: 10221 specifications after preparation and priming surface with resin based synthetic primer,complete all as specified and directed. [Make:- For Pipe: TATA/Jindal/Surya/Prakash ; For CR Tape with primer :IWL 'Pypkote AW 4mm Tape' or equivalent of Make STP/Dr Fixit]
Supply and Fix in repairs,resilient seated, cast iron, flanged butterfly valve,size 65 mm, PN 1.0, Class 125, with stainless steel shaft, lever operated, ISI Marked (IS-13095:1991, Reaffirmed 2003),including provision of carbon steel nuts, bolts & washers, rubber gaskets etc., fixed to water mains, complete all as specified and directed.
Supply and Fix in repairs,resilient seated, cast iron, flanged butterfly valve,size 150 mm, PN 1.0, Class 125, with stainless steel shaft, lever operated, ISI Marked (IS-13095:1991, Reaffirmed 2003),including provision of carbon steel nuts, bolts & washers, rubber gaskets etc., fixed to water mains, complete all as specified and directed.
Supply and Fix,63mm reinforced rubber lined (RRL) hose,15 Metres with SS Coupling & GI binding,Type - A, ISI Marked (IS:636),complete all as specified and directed.
Supply and Fix,branch pipe gun metal 63mm,instantaneous inlet,male threaded outlet,15mm bore nozzle short,ISI Marked (IS:903),complete all as specified and directed
Supply and Fix in repair,hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard,complete all as specified and directed.
Supply and Fix in repair,150 mm size gun metal lift type foot valve,Type-1,ISI Marked (IS:4038),complete all as specified and directed.
Supply and Fix in repair,switch flame proof rotary type with termination box in LM6,16A,single pole 250V,complete all as specified and directed.
Supply and Fix in repair, flame proof, weather proof enclosure made of cast aluminium alloy LM6, weather proof IP65, finished inside and outside with light grey epoxy powder coating for MCB Distribution Board, Three Phase and Neutral, with incoming & outgoing terminals chamber, bus bar chamber comprising of 04(Four) Nos. copper bus bars of suitable rating, separate MCB chambers suitable for accommodating 09 (Nine) Nos. of 10 Amp. 'C' curve SP MCB,03 (Three) Nos. of 20 Amp. 'C' curve SP MCB and 01 (One) No. 63 Amp. 'C' curve, TPN MCB, including cable glands, terminals, hardware and mounting arrangement,complete all as specified and directed. [Cat No. MCBDB/186 of Make “Sudhir” or equivalent Model of Make Balinga/Bajaj]
Material and Labour for applying one coat of aluminium paint on old painted surfaces of steel tubular swaged poles, type 410 SP-31(9.00 Metres Long) including cross arms, bracings, clamps etc. up to 1.5 M above PCC base and marking alternate strip horizontally of width 15 cm with one coat of synthetic enamel paint black & yellow colour above PCC base up to 1.5M height and numbering of poles with letters and figures of height 75 mm, at a height 2.60 metre from ground level and including preparation of surfaces complete all as specified and directed.
Taking down carefully existing damaged/unserviceable Copper/GI strip and GI wire as in earth continuity conductor or main earthing lead,fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other situation of any size and type, complete all as directed.
Taking down existing, galvanized steel tubing, 40 mm bore, of any grade, in trenches or fixed to poles/Walls etc,including all fittings, complete all as directed.
Taking down carefully existing copper strip 20 x 3.15mm for roof conductors and down conductors above ground, realignment/straightening and re-fixing in original position with saddles and fixing screws etc.,complete all as specified and directed.
Taking out carefully existing galvanised iron strip 32 x 6 mm buried in ground,realignment/ straightening and re-laying in original position, complete all as specified and directed.
Supply and Fix,copper strip 20 x 3.15mm with saddles and fixing screws etc.for roof conductors and down conductors above ground, complete all as specified and directed.
Supply and Laying,galvanised iron strip 32 x 6mm buried in ground,complete all as specified and directed. Note:- Earthwork will be measured and paid seperately.
Supply and Laying galvanized steel tubing, 40 mm bore, light grade, in trenches or fixed to poles/Walls etc, for cable protection, complete all as specified and directed.
Taking down carefully existing air termination, single pointed, copper rod 12mm dia.and 300mm long,straightening/aligning and re-fixing in original position,complete all as specified and directed.
Supply and Fix,air termination, single pointed, copper rod 12mm dia.and 300mm long,complete all as specified and directed.
Materials and Labour for maintenance free chemical earthing system using single spike 17.2mm dia, 3000mm long high tensile low carbon steel circular rod, molecularly bonded with copper on outer surface (minimum copper bonding thickness of 250 microns) meeting the requirements of Under Writers laboratories (UL) 467-2007 or latest with 250mm long copper strips of size 50X3 mm, exothermally welded on top of electrode complete including augering (boring) 100-125mm dia hole as required for electrode in any type of soil and back filling with combination of two chemical compounds (one is earth enhancing chemical compound as per IEEE 80 2000 clause 14.5d, conforming to IEC 62561-7, minimum quantity of compound used 15Kg and second is earth enhancing back filled compound as per IEEE 80 2000 Clause 14.5(c), conforming to IEC 62561-7, min quantity of compound used 25Kg), thus minimum total qty 40 Kg per electrode, conforming to IEEE/BS standrads including pit cover light weight made out of high quality polymer with lid made of HDG steel, including nessary testings and commissioning, complete all as specified and as directed. Notes:- (i) The work of earthing shall be carried out by authorised trained rep of OEM. (ii) The acceptable earth resistance at earth busbar/ test point shall be as per users requirement as desired by Engr-in-Charge but it should be below 01 Ohm. At certain locations, it may not be possible to achieve desired earth resistance with one electrode / pit due to higher soil resistivity,in such cases, provision of loop earthing consisting of more than one earth electrode pits shall be done. The number of pits required shall be decided based on the resistivity of soil and resistance achieved for the earth pits already installed. The distance between two successive earth electrodes shall not be less than 3 metres. (iii) The procedure mentioned here-in-before for one earth pit shall be repeated for other earth pits. (iv) Additional earth electrode pits and loop conductor shall be measured and paid seperately . (v) The quoted rate shall also be included the following elements: (a) Complete earthwork including drilling holes for electrode.(b) Earhing electrode-01(One) No Only (c) Backfilling carbon based ground enhancing compound (GEC). (d) Pit cover light weight made out of high quality polymer with lid made of HDG steel. (e) Soil suitable for agricultural purpose required for each pit (f) Copper strip as earthing lead of size 50mmx3mm, 250 mm long only, beyond 250mm, other size will be measured and paid for separately under respective item(s) in this BOQ. (g) All Labour and T&P required including testing of earth network. (vi) Testing for earth resistance shall be carried out in presence of GE and Engr-in-Charge. (vii) Taking out existing unserviceable earthing system complete. (viii) Original purchase vouchers for copper rod and back fill compound and manufacturer test certificate of entire quantity shall be produced by the contractor before commencement of work. (ix) The Earthing shall be carried out with Soil suitable for Agricultural purpose.
kabitaconstruction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .