Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹41.8 L+₹62,890 (1.53%)Rejected-Finance 179 THE MALL AMBALA CANTT 133001 HR | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹41.9 L+₹68,267 (1.66%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹42.2 L+₹97,795.50 (2.37%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹44.3 L+₹3.1 L (7.51%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹95,800
Closing Date
13 Mar 2021, 6:00 pmClosed
CWE Ambala
Headquarter Commander Works Engineer Ambala Mansfield Road Ambala Cantt
SPECIAL REPAIRS TO BLDG No P 01 OF 27 ASC COY UNDER GE NORTH AMBALA CANTT
2021_MES_418056_2
CWE/AMB/NORTH/T-58 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
Ambala Cantt
All as per tender documents
8 documents required · 8 mandatory
₹500
GE NORTH AMBALA CANTT
₹95,800
Yes
12 May 2021
3 Mar 2021
15 Mar 2021
3 Mar 2021
13 Mar 2021
8 Mar 2021
4 Mar 2021 - 6 Mar 2021
Amount
SCHEDULE A PART I (B/R WORKS) Demolition of cement concrete (unreinforced) of any description, in ground floor and pavings not exceeding 15 cm thickness (below or above ground level) and removal of debries to distance exc 250 mtr and n exc 500 mtr complete all as specified and as directed.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc, including stacking of servisable bricks and removal of debries to distance exc 250 mtr and n exc 500 mtr complete all as specified and as directed.
Material and labour for brickwork, with old size bricks, straight or curved on plan to any radius, exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed.
All as above Item No 3.00 but except bricks complete all as specified and as directed. Note: Old serviceable bricks as obtained from serial item No 2.00 hereinbefore shall be reused after cleaning the bricks. The rate quoted shall include for cleaning the bricks also.
Taking down cement or cement lime plaster, of any description, on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, and removal of debries to distance exc 250 mtr and n exc 500 mtr complete all as specified and as directed.
Material and labour for rendering, 15 mm thick, in cement mortar 1:4, mixed with water proofing compound @ 2% by weight of cement or as per manufacturer’s instructions, on fair faces of brick work or concrete surfaces of any description finished even and smooth without using extra cement complete all as specified and as directed.Note: Supply only integral water proofing shall be measured and paid separately.
Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even and smooth without extra cement all as specified and as directed.
Material and labour for rendering 10 mm thick on fair faces of concrete surfaces in ceiling in cement mortar 1:3, finished even and smooth without extra cement all as specified and as directed.
Material and labour for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and as directed.
Supply only integral water proofing compound complete all as specified and as directed.
Supply and fixing of sheet glass, 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 sqm. in each pane including hacking out old glass pane complete all as specified and directed.
Material and labour for preperation of new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
Material and labour for preperation of old plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
Material and labour for preperation of newly plastered surfaces of walls and applying two coats of oil bound distemper over and including 2.-3mm thick wall putty complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed.
Material and labour for preparation of old plastered surfaces of wall and applying two coats of white wash complete all as specified and as directed.
Material and labour for preparation of old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and as directed.
Material and labour for preparation of new steel surfaces, of any description not otherwise described, over 10 cm width or girth and applying two coats of approved colour synthetic enamel paint, over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Material and labour for preparation of new steel surfaces, of any description not otherwise described, over 10 cm width or girth and applying two coats of approved colour synthetic enamel paint complete all as specified and as directed.
Material and labour for preparation of new wooden surfaces, of any description not otherwise described, over 10 cm width or girth and applying two coats of approved colour synthetic enamel paint, over a coat of pink primer complete all as specified and as directed.
Material and labour for preparation of old wooden surfaces, of any description not otherwise described, over 10 cm width or girth and applying two coats of approved colour synthetic enamel paint complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for and removal from site complete all as specified and as directed.
Dismantling timber scantlings 40 sq. cm and over in section in any position in framed or unframed work and removal from site complete all as specified and as directed.
Supply and fixing of rolled mild steel in roof trusses (framed), crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.including necassary cutting, drilling, welding etc quality conforming to Fe 410-W (Gde E-250) quality-A complete all as specified and as directed.
Supply and fixing of rolled mild steel sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates.including necassary cutting, drilling, welding etc quality conforming to Fe 410-W (Gde E-250) quality-A complete all as specified and as directed.
Supply and fixing of rolled mild steel compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc..including necassary cutting, drilling, welding etc quality conforming to Fe 410-W (Gde E-250) quality-A complete all as specified and as directed.
Supply and fixing of rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necassary cutting, drilling, welding etc quality conforming to Fe 410-W (Gde E-250) quality-A complete all as specified and as directed.
Supply and fixing Mild steel screw bolts exc 12mm but n exc 20mm neck dia, machine made with hexagonal or square head at one end & screwed the other or screwed both ends each end to be fitted with washer & one hexagonal or square not exc 30cm long complete all as specified and as directed.
Supply and fixing of pre-painted galvalume, aluminuim zinc coating, GI based corrugated steel sheet, 0.50mm thick, AZ-150 conforming to IS-15961, of red colour, having tensile strength of 550 MPa, as in roof covering/cladding to wall, fixed with self tapping screws including taking down of old sheets of any descriptions as existing on site complete all as specified and as directed. Note- The sheets shall have super durable polyester quality paint of approved colour, 150 gm/sqm total on both sides, suitable for exterior application conforming to IS-15965.
Supply and fixing for pre-painted galvalume, aluminuim zinc coating, GI based Plain steel sheet, 0.50mm thick, of red colour, having tensile strength of 550 MPa, as in roof covering/cladding to wall, fixed with self tapping screws including taking down of old sheets as existing on site complete all as specified and as directed. Note- The sheets shall have super durable polyester quality paint of approved colour, 150 gm/sqm total on both sides, suitable for exterior application conforming to IS-15965.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories,complete all as specified and as directed.
Supply and fixing, 150mm bore PVC soil, waste, drain pipe, type ‘B’, conforming to IS 13592-1992, single socketed, in any length, with rubber rings joints or jointed with solvent cement, laid in trenches or in floors ,complete all as specified and as directed. Note- Rubber rings for pipes and fittings shall conform to IS 5382-1985.
Supply and fixing in replacement of PVC (SWR) bends,150mm bore, of any radius, including jointing with solvent cement complete all as specified and directed.
Material and labour for preperation of old/new plastered/unplastered surfaces of walls, chajjas, balcony, facias, etc. and applying two coats of exterior acrylic emulsion paint over a coat of alkali resistant primer complete all as specified and as directed.
Excavating in post holes or similar holes, each not.exceeding 0.5 cu mtr, getting out, in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and directed.
Material and labour for plain cement concrete (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregates as in foundation filling and mass concrete, sub base, levelling course complete all as specified and directed.
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in, in soil, including spreading leveling watering and well ramming in layers not exceeding 25 cm each complete all as specified and as directed.
Removing excavated spoil/materials to a distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 above the starting point complete all as specified and as directed.
Material and labour for plain cement concrete (1:4:8) type D-2 using 40mm graded mechanically crushed stone aggregates as in foundation filling and mass concrete complete all as specified and directed.
Material and labour for 40mm thick plain cement concrete (1:2:4) type B-0 using 12.5mm graded mechanically crushed stone aggregates as damp proof course to horizontal or vertical surfaces including necassary form work complete all as specified and directed.
Material and labour for machine cut kota stone slab 16-18 mm thick ( size of each stone not less than 55cm x 55cm), laid in flooring, over and including cement screed bed 20mm thick in cement mortar (1:4) base over 25mm thick PCC (1:2:4) type B1 (using 12.5 mm graded stone aggregates) set and jointed in neat cement slurry @ 3.00 kg/Sqm and pointed in white or coloured cement to match the surface mixed with pigment to match shade of the slab including cutting, waste, rubbing and polishing (Granite finish), roughening of old surfaces complete all as specified and directed.
Material and labour for machine cut kota stone slab 16-18 mm thick ( size of each stone not less than 55cm x 55cm), laid on vertical surfaces of skirting/dado, over and including cement screed bed 10mm thick in cement mortar (1:3) and set and jointed in neat cement slurry @ 3.00 kg/Sqm and pointed in white or coloured cement to match the surface, roughening of old surfaces complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position including reinforcement cut as required to facilitate demolition and removal of debries to distance exc 250 mtr and n exc 500 mtr complete all as specified and as directed.
Material and labour for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete specified and directed.
Material and labour for use and waste of formwork to soffits and sides of roof beams, lintels for rough finished flat surfaces of concrete complete specified and directed.
Material and labour for use and waste of formwork to chullah hoods, chajjas,troughs and similar items including edges for rough finished flat surfaces of concrete complete specified and directed.
Material and labour for reinforced cement concrete (1:1.5:3) type A-1 (Nominal mix) using 20 mm graded stone aggregates, as in beams, cantilevers, bressumers, lintels over 1.5 mtr span complete all as specified and directed.
Material and labour for reinforced cement concrete (1:1.5:3) type A-1 (Nominal mix) using 20 mm graded stone aggregates, as in slabs supported on walls, beams, columns in floors roofs, landings , balconies, deck slab etc complete all as specified and directed.
Material and labour for reinforced cement concrete (1:1.5:3) type A-1 (Nominal mix) using 20 mm graded stone aggregates, as in chajjas complete all as specified and directed.
Material and labour for mild steel TMT bars Fe 500/550 D, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and labour for mild steel TMT bars Fe 500/550 D, 8mm dia, as in stirrups, spacers and binders reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and labour for roof treatment over roofs comprising of following works:- (i) Applying a coat bitumious primer @ 0.40 ltr/ Sqm of density 0.87 to 0.89 kg/ltr at 25' C temprature and viscosity 70-160 cps. (ii) Laying 3mm thick APP(atactic polypropylene polymer) modified prefabricated, five layer, weight not less than 3.60 kg/Sqm, water proofing membrane, black finish, reinforced with non woven polyster matt over the primer coat with overlap of 100mm at the sides and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface. (iii) One coat of bonding material i.e blown type bitumen of grade 85/25, confirming to IS 73, heated to a working temperature of 180 degree C and applied @ 1.20 Kg per square metre. (iv) 10mm thick plastering in cement mortar 1:4 finished even and smooth mixed with WPC @ 2% by weight of cement on roof surface. (v) Applying two coats of water proofing paint with aluminium finish on top of laid APP surfaces including preparation of surface Notes:-(i) Joint strength in logitudinal and transverse direction at 23'Cat 650/450 N/5 cms (ii) Tear strength in logitudinal and transverse 150'C when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shall be got down through the authorised applicator of manufactures of membrane only.(iv) The contractor will carry out ponding test after application of APP treatment before claiming payment.
Material and labour for 75mm thick PCC 1:3:6 type C-2 (using 40 mm graded mechanically crushed stone aggregate), as in plinth protection/PCC path and paving, laid in panels of area not exceeding 1.20 sqm with 12mm wide joints filled with mastic (using bitumen and sand mixture applied hot in the ratio of 1:3 by weight) formed at the end of each panel and change in direction of plinth protection/PCC Path and paving and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for PCC 1:2:4, type B1 (using 20 mm graded mechanically crushed stone aggregate), in lintels upto 1.5m clear span cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed
Taking down chowkats or frames with shutter, area not exceeding 1.50 Square metre (w/o taking off shutters from frames) and removing from site, including cutting holes in wall/concrete for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces in CM (1:3) and finishing the surfaces to match with existing finish complete all as specified and directed.
Taking down chowkats or frames with shutter, area exceeding 1.50 Square metre and not exceeding 4.00 Square metre (without taking off shutters from frame) and removing from site, including cutting holes in wall/concrete for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces in CM (1:3) and finishing the surfaces to match with existing finish complete all as specified and directed.
Taking down shutters of any description exceeding 1.0 Sqm and not exceeding 2.0 Sqm each and removal from site complete all as specified and directed.
Taking down shutters of any description exceeding 2.0 Sqm each and refixing in same opening duly easing complete all as specified and directed.
Supply and fixing of pressed steel frames for doors of size 105x60mm, 1mm thick, with one or more rebates including, hold fasts of 25mm x 4mm MS FI, 25cm long, 6 Nos in each chowkhat, necessary lugs, 4 Nos 100 mm MS butt hinges medium weight, cold rolled, welded for each frame, lock strike plate, including sanding, tarring backs of chowkhats, PCC 1:3:6 type C-0 filling in frame and for holdfast, 2 Nos 12 mm dia tie bars at the bottom of frame and one shop coat of red oxide primer etc complete all as specified and as directed.
Material and labour for factory made 35mm thick flush shutters with block board core and plywood face panels, commercial type on both side, complete all as specified and directed.
Supply and fixing of steel window box type, using ERW hollow 'P' section, factory made, comprising double frame for and including gauged and glazed skeleton shutter, 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 of HQ CE Chandigarh Zone as applicable complete all as specified and as directed. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frame shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill 10 mm square bar irrespective of whatever shown on drawings and one shop coat of zinc chromate primer . The pattern of grill shall be all as shown on drawing (iii) Glazing, wire mesh and painting shall be measured and paid for separately. (iv) The drawings may be referred from GE office or from this office during working hours.
Supply and fixing of steel ventilators, fixed type, with glazing bars confirming to IS 1038-1983 and IS 7452-1990 complete all as specified and directed.
Supply and fixing of second class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessaty' labours; articles not exceeding 200 cu.cm each complete all as specified and directed.
Supply and fixing of extruded aluminium alloy handles, 150 mm long, fabricated type, anodised, ISI Marked complete, all as specified and as directed.
Supply and fixing of aluminium anodised, 200mm long, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Supply and fixing of mild steel sliding door bolts, 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed.
Supply and fixing of frosted glass, 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 sqm. in each pane complete all as specified and directed.
Supply and fixing of stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fixing of mild steel, cold rolled, butt hinges, 100mm size, medium weight, ISI marked and fixed complete all as specified and as directed.
Supply and fixing of mild steel, cold rolled, butt hinges, 50mm size, medium weight, ISI marked and fixed complete all as specified and as directed.
Material and labour for raking out joints/ pointing to brick work in walls or to bricks on edge in floors, surface channels, roofs etc built in cement mortar complete all as specified and directed.
Material and labour for Keyed pointing to brick walls built in cement mortar 1:4, complete all as specified and directed.
SCHEDULE A PART II (E/M WORKS) Taking down carefully any type of point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, regulators, sockets, tube light fittings with all accessories etc., and/or drawing out from existing conduit/batten and removal of materials from site and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces with matching OBD/White wash/Distemper complete all as specified and as directed.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLS-H, 1100 volts, ISI marked, PVC insulated and unsheathed stranded cable drawn through and including non metallic, medium grade PVC concealed conduit not less than 25.00mm to 32.00mm dia and its fittings, including cutting chasing on wall/ceiling, including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes, ISI marked, including 1.5 sqmm single core PVC insulated and unsheathed FRLS-H cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with and including MS flush boxes of 2 to 18 modules with inner and outer cover plates, confirming to IS 5139 of 1969 and IS 14772 of 2000 for fixing modular switch sockets for one light point (For flourescent Tube/ LH, Bldg Security light, Mirror light)/fan point/bell point controlled by one one way switch complete all as specified and as directed. Notes :- (i) Switch, socket, ceiling rose, lamp holder, bell, bell push and fan regulators to be measured and paid for separately. The quoted rates are deemed to be included for providing cover plates and MS flush boxes as required at site. (ii) PVC Conduit conforming to IS 9537 part I & III. (iii) All chases will be cut by chase cutter only and surfaces shall be make good as per existing surfaces. (iv) The concealed conduits and MS boxes as fixed against new point wiring, shall be verified by Engineer-in-Charge before making good the surfaces by plastering and other finishes.
Description all as per Srl item No. 75.00 here in before but for one 3 pin socket outlet point 5 Amp on same board.
Description all as per Srl item No. 75.00 here in before but for one 3 pin socket outlet point 5 Amp on Independent board.
Description all as per serial item No. 75.00 above, but for one socket point 15 and 5 Amps (independent), with 2.5 Sqmm PVC, FRLS-H, unsheathed, multistranded cable, 1100 volts grade, ISI marked, including 2.5 Sq mm size, green colour, PVC insulated FRLS-H, continuous copper earth wire and connected to common earth dolly complete all as specified and as directed.
Supply and fixing of switch modular, 6 Amps, one way, one module, single pole, 230 volts, 50 Hz complete all as specified and directed.
Supply and fixing of switch modular, 15 Amps,one way, one module,single pole, 230 volt complete AC supply all as specified and directed.
Supply and fixing of socket outlet modular, 2/3 pin combined, 6 amps, one way, 2 module, single pole, 230 volts complete all as specified and directed.
Supply and fixing of socket outlet modular, 2/3 pin combined,16 amps, one way, 2 module, single pole, 230 volts complete all as specified and directed.
Supply and fixing of ceiling rose surface bakelite 65x50mm, three terminals complete all as specified and as directed.
Supply and fixing of lamp holder, PVC/Polycarbonate type, with back plate suitable for batten fittings complete all as specified and as directed.
Supply and fixing of retrofit LED lamp/Bulb of 12 watt B-22 base complete all as specified and directed.
Supply and fixing of Television (TV) socket outlet, 2/3 pin, 5 Amps, 230 volts complete all as specified and as directed.
Supply and fixing of fan regulator/dimmer stepped type, 120 watt, 1/2 module, 230 volts, 50 Hz AC supply, suitable for ceiling fan, any type/make/sweep complete all as specified and as directed.
Supply and fixing in replacement channel for fixing of LED tube rod, made of aluminium housing body in CRCA sheet, suitable for 18/20 watt LED tube light, high efficient, AC, 220-240 Volts, 50 Hz, with built in electronic drivers having THD < 10%, connecting up with core 1.5 sq mm flexible copper conductor cable from ceiling rose to connector block of light fitting including T-5 LED tube rod 1x18/20 watts, AC, 220-240 Volts, 50 Hz, high efficient T8 with aluminium extrusion heat sink for optimum performance with high lumen efficiencydisconnecting and taking down existing light fitting and removal complete all as specified and directed.
Material and labour for sub main wiring with two single core, 6 sqmm, FRLS-H, 1100 volts grade, ISI marked, with multistranded, PVC insulated unsheathed copper conductor cable, drawn in and including rigid non metallic PVC conduit, medium grade, not less than 25 mm dia, ISI marked for housing cables, concealed in wall or ceiling including cutting chasing and making good, with accessories with and including one additional 6 sqmm, PVC insulated, stranded copper conductor, FRLS-H, green colour for earth continuity conductor connected to common earth dolly including taking down old unserviceable sub main wiring of any type and making good the disturbed surface complete all as specified and as directed. Note- Three runs of 6.0 sqmm cable and one run of concealed conduct shall be measured as one unit.
Supply and fixing of MCB, single pole, 240 volts, 50Hz, breaking capacity 10KA, 'C' curve, 6-32 Amps, ISI marked complete all as specified and as directed.
Supply and fixing of RCBO, 40 Amps, double pole, conforming to IEC-61009, 2 module, 300 ma (HI immunity) sensitivity, 230 volts, 50 Hz, with degree of protection IP-20, for three protection, over load prtection, earth leakage protection, and short circuit protection, ISI marked complete all as specified and directed.
Supply and fixing in replacement of over voltage relay, one module, 230 volts, single phase, adjustable from 170 volts to 230 volts in one module suitable for (1Ph+N) complete all as specified and directed.
Supply, insatallation, commissioning and testing of distibution board for MCBs, SPN, 12 way, acrylic double door, IP 43, as per IS 8623, 240 volts, with and including 200 amps fully insulated copper bus bar fixed on wall duly grouted in solid block wall with and including copper lugs/thimbles duly crimped for connection including taking down and removal of old unserviceable DB with MCB of any capacity, size and type complete all as specified and directed. Note :- MCB shall be measured and paid separetely.
Supply and fixing of sheet metal enclosure MCB DB, TPN, vertical type, 4 way, double door, 415 volts, load line, powder coated complete alongwith 200 Amps rated bus bar, IP-43, with and including one No. MCCB, 4 pole, 25 kA, 100 Amps as incomer and MCBs as outgoing with suitable size of MS cabinet 2mm thick and making all type of connections with suitable size of gland for incomer cable complete concealed on wall surface, making good the disturbed portion with adjoining surfaces to match with existing finish fixed in repair with shrouded neutral bar and insulated bus bar and earth link including taking down old unserviceable DBs and MCBs, any type and removing from site complete all as specified and directed.
Supply and fixing in replacement of LED security light luminaire 45 watt, 230 volts, 50 Hz, made up of die cast aluminum housing with black epoxy powder coating with cover heat resistant glass, safety input voltage range 170 to 270 Volts, IP66 protection, including service brackets of GI pipe 25mm bore, light grade, of length 1.60 metre, bent to required shape, fixed with MS clamps of size 40 x 6mm flat iron strip, 150mm long and 4 Nos.8mm dia stainless steel bolts and nuts and washers and suitable reducer for connecting to GI pipe as required at site and making all required electrical connections using 3 core copper flexible cable from terminal box to ceiling rose including disconnecting complete all as specified and as directed.
Disconnecting/dismantling old unserviceable earthing and material and labour for new earthing with galvanised earth plate electrode 600mm x 600mmx 6mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 4.00 mm GI wire earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire and thimbles protected by galvanized steel pipe 15mm dia (light grade) and connected to main switch or main control board all as shown in Electrical Plate No.3 of SSR Part-I & including necessary excavation and earth work in any type of strata, PCC (1:3:6) type C1 in pit, RCC cover slab 50mm thick in 1:2:4 type B-1 using 8mm dia TMT bars @10cm c/c both way with one 8mm dia bar as handle for lifting, 20mm dia GI medium grade watering pipe, funnel, wire wesh, charcoal or coke & salt in alternate layers, etc.all as indicated including testing on completion complete all as specified and directed. Note:- The new earthing shall be provided adjecent to old earthing site on the locations as directed by engineer in charge.
Supply and laying of LT underground cable, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty), 1100 volts grade, with stranded aluminium conductor of size 3.5 core, 25 Sqmm and laying in trenches including taking down old cable from trenches complete all as specified and as directed.Note :- Excavation and earth work shall be measured and paid separetely.
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth and getting out in soft/loose soil for laying of cable complete all as specified and as directed.
Returning filling in, in soil, including spreading leveling watering and well ramming in layers not exceeding 25 cm each complete all as specified and as directed.
Removing excavated spoil/materials to a distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 above the starting point complete all as specified and as directed.
Material and labour for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.Note:- The punned thickness 18cm shall be considered for payment purposes.
Supply and laying un-reinforced, precast concrete cable cover, class LV type 1, flat, with peak, size 250 mm x150 mm x40 mm complete all as specified and as directed.
Supply and fixing in replacement of light grade, GI tubing, of size 40mm dia, for cable protection and fixed with clamp to pole and wall with nuts and bolts complete all as specified and as directed.
Note:- Amount of credit of Rs.4,18,403.00 for retrieved materials is mentioned in Schedule of Credit Page No. 17R of tender documents in pdf form which will be deducted offline while acceptance of tender.
Bhagwan Dass and Sons
V K Constructive Builders
S S Engineers & Contractor
NAVREET CONSTRUCTION
Bairagi Builders
Karishan Kumar goel
Ashwani Kumar
M/S SHANTI CONSTRUCTION
M/s B.S.Jain
M/s Kuljit singh bedi
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .