Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | L1 | Accepted-AOC lowest tender | |
| 2 | L2₹19.9 L+₹2.2 L (12.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹24.1 L+₹6.3 L (35.6%)Rejected-Finance 9 8 B THENGUMTHARAVIL MLA ROAD PANANGAD PO KOCHI 682506 | KOCHI | ERNAKULAM | KERALA | 682506 | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
1 Aug 2020, 6:00 pmClosed
GE NS KOCHI
Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682 004
SPL REP TO BLD LT PANEL AT ARJUN BLOCK OF SNCO MESS, REPL OF EXIS ALARM SYSTEM IN CARES AND PROV OF WATER TANKS IN A, B AND C WING AND PUMPING MOTOS FOR 900 MEN BLOCK AND SENIOR SAILORS ACCM INS GARUDA UNDER GE (NS) KOCHI
2020_MES_360078_1
8706/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Kochi
Class D, Category b(i) / c(ii)
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹62,000
Yes
24 Oct 2020
10 Jul 2020
3 Aug 2020
10 Jul 2020
1 Aug 2020
18 Jul 2020
10 Jul 2020 - 17 Jul 2020
Amount
Supply and Laying XLPE insulated galvanised steel strip or wire armoured electric power cable with stranded aluminium conductor 1100 V grade of size 150 sqmm 3.5 core complete all as specified and directed
Dito all as per item No 1, but of size 120 sqmm 3.5 core complete all as specified and directed
Material & Labour for replacement of LT heat shrinkable 70 to 120 Sqmm, 3.5/4 core cable joint complete all as specified and directed.
Dito all as per item No 3, but joint of size 150 to 185 Sqmm 4 Core complete all as specified and directed
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth in hard/dense soil and getting out excavated soil/sand/unserviceable LT Cable for laying of cable complete all as specified and directed.
Material and Labour for Sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer In Charge.
Removing excavated material in any type of soil not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Material and labour for laying factory made unreinforced PCC cable cover class LV, Type I Flat size 250 x 150 x 40mm complete all as specified and directed
Cutting existing road/hardstand of any type by using crow bar chisel or by mechanical means, not exceeding 45 cm in width and not exceeding 1.5 metre in depth for laying of GI pipe including making good the surface by returning 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returned & filled soil well rammed, watered in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge. Note: - GI pipe will be measured and paid separately.
Supply and laying in trenches/fixed on walls/poles GI tubing of 50 mm bore, medium grade with all fittings complete all as specified and directed.
Material & Labour for sub main wiring with 6 runs (3 Phase, 1 Neutral & 2 Earth) of 6 Sqmm single core, PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through and including surface PVC conduit pipe of medium duty not less than 32 mm dia including necessary PVC conduit specials and connecting with suitable size thimble complete all as specified and directed. Note: - 6 runs of 6 Sqmm size PVC copper cable and 1 run of PVC conduit shall be measured as one unit length.
Ditto all as per item No 12, but for 6 runs of 10 Sq mm cable complete all as specified and directed. Note: - 6 runs of 10 Sqmm size PVC copper cable and one run of PVC conduit shall be measured as one unit length.
Taking down existing unserviceable LT Panel carefully duly disconnecting all the connections and deposited to MES store yard.
Material & Labour for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (Earth pit not less than 2.25 Metre below the ground level) with top edge of earth plate not less than 1.5 Metre below ground level connected to galvanized iron strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/ LT panel etc. and testing on completion, complete all as specified & directed by Engineer-in-Charge.
Supply, install testing and commissioning Outdoor LT Panel 2mm thick CRCA Sheet 80 GSM, IP rating IP42, with mounting plates with and including the following switch gears and components and 1000 Amps capacity copper bus bar, complete wiring, earth strip, sleeves, ferrules, DIN rail, Neutral link, Cable glands, lugs, PCC foundation, Drawing wallets etc and taking out incoming and outgoing cables from the loop including connections complete all as specified and directed. IN COMING (a) 630A, 50kA, FP Manual D/O type ACB with Microprocessor Based LSIG Protection Release - 1 No (b) Multifunction Meter with RS485 Communication Port, Cl- 0.5 - 1 No (c) Metering CTs Class 0.5, 10VA - 3 No (d) RYB Phase Indication LED Cluster Type Lamps - 3 No (e) ON, OFF & TRIP Indication LED Cluster Type Lamps - 3 No (f) 6A Control MCB SP type - 4 No OUT GOING (a) 125A, 25kA, TPN MCCB with Adjustable Thermal Magnetic Release with Operating Handle - 8 No (b)100A, 25kA, TPN MCCB with Adjustable Thermal Magnetic Release with Operating Handle - 8 No Sub incomer (i) 630A On Load Changeover switch - 1 No
Supply, install, testing and commissioning of Microprocessor based Multi-loop, True Peer-to-Peer Network Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 events plus 1000 alarm log history events, QWERTY keypad for programming, The panel should be equipped with 6 numbers of loops considering 20% Spare capacity in each loop, Each loop shall have a capacity of minimum 300 analog addressable devices with option for group device polling for faster responses, The panel shall work in degrade mode in case of CPU failure, Four access levels, flash EPROM, 24 Volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 minutes in alarm condition, There shall be options on the FACP to connect external 3rd party printers, The MTBF (Mean Time before Failure) which signifies the reliability of the product) shall be minimum 20 years and the FACP and all accessories shall be UL listed and FM approved including taking down of unserviceable old one complete all as specified and as directed.
Supply, install, testing and commissioning of addressable Optical smoke detector shall have multi co-operative sensing technology for faster response & avoid false alarms, the detectors shall have twin bi-color LED for 360 degree viewing, Addressing shall be with user friendly rotary decimal switches with addresses from 001-159 and the detectors shall be UL listed and FM approved including taking down unserviceable old one complete all as specified and as directed.
Supply, install, testing and commissioning of Control Module for Sounders /Strobes/Sounder cum Strobes, The control modules shall provide DPDT contact rated at 24V DC, 2A, the device shall have an LED which shall blink in normal state & get steady on activation to monitor the heat status of the device, Addressing shall be with user friendly rotary decimal switches with addresses from 011-159, the module shall be UL listed and FM approved, Module shall be supplied with mounting base plate from OEM for ease of installation & maintenance including taking down unserviceable old one complete all as specified and as directed.
Supply, install, testing and commissioning of intelligent addressable Manual Call Point (Pull down / Break Glass Type), The device shall have an in-built monitor module for addressing and an LED which shall blink in normal state & get steady on activation to monitor the heat status of the device, Addressing shall be with user friendly rotary decimal switches with addresses from 011-159 and the module shall be UL listed and FM approved including taking down unserviceable old one complete all as specified and as directed.
Supply, install, testing and commissioning of intelligent analogue addressable Fault Isolator modules including all accessories like junction boxes, glands, terminating legs complete as required and as per specification and UL listed and FM approved including taking down
Supply and Fix FRLS Armoured cable 2X1.5 Sqmm with ISI marked with all accessories such as clamps/screws etc, including taking down the old unserviceable one complete all as specified and as directed. Notes for item No- 17 to 22:- 1. Rate quoted by the Contractor shall deemed to be included the making good to the disturbed wall/floor/False Ceiling/paint while executing the work without any extra cost. 2. The Contractor shall carry out the work through OEM or Service personal authorised by the OEM. Necessary proof of documents shall be submitted to the Engineer In charge for the approval. 3. The Complete Fire Detection & Alarm System shall be tested in the presence of Representatives of Accepting Officer, User Representative, Contractor and Engineer-in-Charge. The unit rate quoted shall be inclusive of the above and nothing extra will be admissible.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation or for shafts, wells, cesspits, manholes, pier holes etc, not exceeding 10 sq m on plan and not exceeding 1.5 metre in depth and getting out soft/ loose soil complete all as specified and as directed.
Supply and laying in trenches CPVC pipe of outer diameter 40mm, SDR 13.5 and plain CPVC SDR 11 fittings complete all as specified and as directed.
Supply and laying of CPVC pipe of outer diameter 50mm, SDR 13.5 and plain CPVC SDR 11 fittings, on wall/ceiling or laying in floor complete all as specified and as directed.
Supply and laying of CPVC pipe of outer diameter 25mm, SDR 13.5 and plain CPVC SDR 11 fittings, on wall/ceiling or laying in floor complete all as specified and as directed.
Supply and fixing of Rotational Moulded polyethylene water storage tank (cylinderical vertical with closed top) hoisted and fixed in position of capacity 1000 Litres including making holes for inlet and outlet pipe with proper sealing by checknut and washer complete all as specified and as directed.
Supply and fixing of brass ball valve (float valve) with polythene float and fly nut high pressure of PTMT with epoxy coated alminium rod and high density plastic ball of size 40mm screwed for CPVC pipe and fixed (minimum weight 40mm - 690gms after reducing 40mm pipe to 25mm) including all other fittings required at site as directed by Engineer In Charge.
Supply and fixing of CPVC ball valve of outer dia 50mm, suitable for CPVC pipe including necessary fittings complete all as specified and directed.
Ditto all as per item No 29, but for CPVC Valve of outer dia 40mm.
Ditto all as per item No 29, but for CPVC Valve of outer dia 25mm.
Material & Labour for point wiring for 3 pin socket outlet 15Amps (for starter), independent, using PVC single core, sheathed cable of copper conductor of 4 Sqmm size in PVC conduit with cable for monoblock pump set, complete all as specified and directed.
Supply and fixing of Isolator SPN of 40 Amps ,240V, complete all as specified and directed.
Supply and fixing of monoblock pump set suitable for 230V SPN system having capacity 2HP, head range of 8-34 meters & discharge range of 252 to 30 LPM including starter wiring conduit etc, having 50mm x 40mm cross section, including necessary PCC staging complete all as specified and directed.
Supply and fixing of monoblock pump single phase 1 HP, 50 HZ including suitable DOL starter complete all as specified and as directed
Supply, laying and testing of XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and as directed
An Amount of Rs. 14,550/- towards Credit Schedule shall be deducted to arrive the Contract Sum.
PHEJAYS AGENCIES
T.I.John and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .