Chief Officer, Mangrol Nagarpalika, Mangrol
PURCHASE OF LED STREET LIGHT, MCB & TIMER FOR STREET LIGHT FOR VARIOUS LOCATION OF MANGROL NAGARPALIKA, MANGROL, DIST. JUNAGADH (THIRD ATTEMPT)
299370
MRPL/MNGRL/09-Pur. LED, MCB Timer/R02
Open
Electrical - All
Junagadh
3 documents required · 3 mandatory
₹1,500
Chief Officer, Mangrol Nagarpalika, Mangrol
₹36,445
28 Apr 2026
28 Apr 2026
28 Apr 2026
6 May 2026
28 Apr 2026
Name of work : PURCHASE OF LED STREET LIGHT, MCB & TIMER FOR STREET LIGHT FOR VARIOUS LOCATION OF
MANGROL NAGARPALIKA, MANGROL, DIST. JUNAGADH (THIRD ATTEMPT)
Item Quantities Item Descrption Estimated Rates Unit Total Amount
Item Quantities Item Descrption Estimated Rates Unit Total Amount
No. Estimated in Figure in Words according to
but may be estimated
more or less quantities.
1 Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminium housing with smooth finish powder coated
and heat sink extruded aluminium with diffuser and
Polycarbonate optics / lenses with company mark / name
engraved or embossed 160 to 270V, Power Factor more
than 0.95, THD < 10%, CCT 3000K to 5700K, Uniformity
ratio > 0.45, Luminaire efficacy > 100 lumens / watt.
LED driver efficiency > 85%. (fittings required LM-79 &
LM-80 certificates) (NOTE: Below description have shown
ranges of Wattage capacity of LED fittings. The Engineer
incharge may select any wattage capacity between the
(A) Street Light (IP-65), Surge protection - 4KV integral (Rupees Eighteen Hundred
and Light must have 440V AC line supply with over- Twenty Three and Paise
voltage 24 Watts Cat. III Five only)
Item Quantities Item Descrption Estimated Rates Unit Total Amount
Item Quantities Item Descrption Estimated Rates Unit Total Amount
No. Estimated in Figure in Words according to
but may be estimated
more or less quantities.
2 Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminium housing with smooth finish powder coated
and heat sink extruded aluminium with diffuser and
Polycarbonate optics / lenses with company mark / name
engraved or embossed 160 to 270V, Power Factor more
than 0.95, THD < 10 %, CCT 3000K to 5700K,
Uniformity ratio > 0.45, Luminaire efficacy >
lumens/watt. LED driver efficiency > 85%. (fittings
required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of
LED fittings. The Engineer incharge may select any
wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection - 4KV integral (Rupees Twenty Two
and Light must have 440V AC line supply with over- Hundreds One and Paise
voltage protection. 36 watts Cat. III Eighty only)
3 Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics / lenses, with toughened glass with
company mark / name engraved or embossed 160 to
V, Power Factor more than 0.95, THD < 10%, CCT
3000K to 5700K, Uniformity ratio > 0.45, Luminaire
efficacy > 100 lumens / watt. LED driver efficiency >
85%. (fittings required LM-79 & LM-80 certificates)
(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings. The Engineer incharge may
select any wattage capacity between the ranges shown.)
Item Quantities Item Descrption Estimated Rates Unit Total Amount
Item Quantities Item Descrption Estimated Rates Unit Total Amount
No. Estimated in Figure in Words according to
but may be estimated
more or less quantities.
(A) Street Light (IP-65), Surge protection -4KV integral (Rupees Four Thousand
and Light must have 440VAC line supply with over- Nine Hundred Ninety
voltage protection. 60 Watts Cat. III Seven and Paise Forty
10.00 4997.48 Eight only) Ea.
4 Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics / lenses, with toughened glass with
company mark / name engraved or embossed 160 to
270V, Power Factor more than 0.95, THD < 10 %, CCT
3000K to 5700K, Uniformity ratio > 0.45, Luminaire
efficacy > 100 lumens / watt LED driver efficiency >
85%. (fittings required LM-79 & LM-80 certificates)
(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings. The Engineer incharge may
select any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection - 4KV integral (Rupees Six Thousand Five
and Light must have 440V AC line supply with over- Hundred Sixty Six and
voltage protection. 120 watts Cat. III Paise One only)
5 Providing & erecting 415V MCB Four Pole for Motor & (Rupees Seven Hundred
Inductive Load (C Curve) having 10KA breaking capacity Eleven and Paise Four
& confirms to IS: 8828 in existing box having following only)
capacity (C) 63 Amp. Cat. III
Item Quantities Item Descrption Estimated Rates Unit Total Amount
Item Quantities Item Descrption Estimated Rates Unit Total Amount
No. Estimated in Figure in Words according to
but may be estimated
more or less quantities.
6 Supplying & erecting approved make time switch with (Rupees Twenty Three
single pole air break contacts suitable for 230V. 15/16A. Hundreds Two and Paise
complete with self starting motor driven clock ‘ON’ & Eighty only)
'OFF’ automatic arrangement at any predetermined time
during each 24 hours, With nickel cadmium rechargeable
battery backup erected as directed.
7 Supplying & erecting power contactor, AC3 duty for time (Rupees Twenty Seven
switch complete erected as per direction Cat III (D) 4 Hundred Fifty Six and
pole 440V 40 Amp. Paise Twenty Nine only)
Add G.S.T. @ 18%
One percent of the Estimated cost of work put to tender shall be recovered from the running bills of the contractor as testing charges,
after deducting the cost of material proposed in scheduled-A at basic rate. One percent labour cess will be deducted from contractor’s
I/ We am/are willing to carry out the work at _____________________% above / below _____________________________%
below / above the estimated rates mentioned above amount of my / our tender works out as under :-
Estimated amount put to tender : Estimated amount put to tender :
Signature of contractor Chief Officer
MANGROL NAGARPALIKA
Item Quantities Item Descrption Estimated Rates Unit Total Amount
Item Quantities Item Descrption Estimated Rates Unit Total Amount
No. Estimated in Figure in Words according to
but may be estimated
more or less quantities.
Item Quantities Item Descrption Estimated Rates Unit Total Amount
Item Quantities Item Descrption Estimated Rates Unit Total Amount
No. Estimated in Figure in Words according to
but may be estimated
more or less quantities.
1) All the work shall be carried out as per MOST specification and specification on the division or as directed.
Rates quoted includes clearance of site (prior to commencement of work and at its closed) in all respects and held gross for under all
conditions, site moisture weather etc.
In RCC item when there is change in grade of concrete mix or change in consumption of cement as per actual mix design then the difference
in consumption of cement shall be deducted from the rate of original item valued at the star rate as mentioned in tender. However no extra
payment shall be made for use of additional Quantity of cement as per actual concrete mix design. Concrete mix design shall be done in
GERI laboratory only.
The Contractor shall exhibits a board as per Govt. circular No. 2DK – 3277 / 1657 N Dt. 26–01-73 with detail of specification and details of
work and amount involved at site without any payment as directed by the Engineer in charge.
Testing of materials be as per statement attached with the Specifications, the materials shall be tested in G.E.R.I. Bill for testing shall be
5) paid by the Executive Engineer and 1% of the (one percent) of amount put to tender after shall be recovered from the running account bills
of the works. (As per G.R. (R&B) Deptt., No. TNC/1085/4/C dtd. 20.12.91.
6) The contractor shall quote even "NIL" if no reduction is proposed.
One precent of estimated cost put to tender for this work shall be recovered from the contract payments as "LABOUR CESS". In terms of the
7) Gujarat Government Gazette Extra ordinary dated 12.12.04. Implementation of building and other construction workers regulation of
equipments and conditions of service Act-1996)
8) Photographs of before work and after work will be submitted by the contractor at the time of each bill submission.
The contractor is solely responsible to bare all applicable taxes. I.e. GST etc. and department will not entertain any contractor representation
to reimburse any financial burden due to applicable taxes : i.e. GST etc.
Signature of contractor Chief Officer
MANGROL NAGARPALIKA
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
02. Mile Stone Dates and Tender Nivida.pdf
08. Comperative Statement.pdf
04. Schedule-B.pdf
05. Specification Index.pdf
06. Details of Work.pdf
07. ELECTRIC SPECIFICATION.pdf
01. SBD.pdf
10. PARIPATRA.pdf
09. LED light Specification.pdf
03. Qualification Criteria.pdf
Download all tender documents and submit your bid