Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.7 L+₹1.9 L (5.37%)Rejected-Finance | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹43.6 L+₹8.7 L (25.0%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
26 May 2023, 6:00 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
CONSTRUCTION OF GAS GODOWN AT MAT DEPARTMENT AND SPECIAL REPAIRS TO ROOF TREATMENT OF BAY-I AT MAT DIVISION AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2023_MES_590725_1
8842/E8
Open Tender
Civil Works
Item Rate
270 days
Naval Dockyard Visakhapatnam
As per tender documents
9 documents required · 9 mandatory
₹500
GE (I) DM Visakhapatnam
₹82,000
Yes
28 Jun 2023
21 Apr 2023
2 Jun 2023
21 Apr 2023
26 May 2023
12 May 2023
Amount
[SCHEDULE 'A' PART-I [B/R WORKS]
Surface excavation not exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil all as specified and directed.
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
Excavating in post holes (or similar holes) each n. exc. 0.5 cum, getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25 cm watering and removing surplus soil to distance n. exc 50 m and making good surface complete all as specified and directed.
Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil exc 1.5 KM but not exc 5.0 KM and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed.
M&L PCC 1:2:4 type B1 type (using 20 mm graded crushed stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
M&L for sand filling under floor including watering and consolidation complete all as specified and directed.
M&L hard core of broken stone of gauge n. exc. 63 mm, deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.
M&L Moorum / red bajri filling in floors or avings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering and consolidation complete all as specified and directed.
M&L PCC 1:4:8 type D2 type (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
M&L 100 mm thick cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) in sub base of floors finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L 100 mm thick cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) in floors finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L chequered cement concrete colour tiles with grey cement and pigment 30 cm x 30 cm x 20 to 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments over 15 mm thick 1:6 cement morter screed bed as in floor complete all as specified and directed.
M&L RCC 1:1.5:3 type A1 (using 20 mm graded crushed stone aggregate) as in foundation, plinth beams, base of column, footing and mass concrete etc. complete all as specified and directed.
M&L RCC 1:1.5:3 type A1 (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers posts and struts etc. complete all as specified and directed.
M&L RCC 1:1.5:3 type A1 (using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintel over 1.5 m span complete all as specified and directed.
M&L MS TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as reinforcement complete all as specified and directed.
M&L M.S. TMT bars 5 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as in stirrups spaces, binders and nibs etc. complete all as specified and directed.
Use and waste form work to side of concrete foundation, footings, bases of columns, raft and beams and similar work, vertical or to batter as in rough finished surfaces of concrete all as specified and directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns etc. square, rectangular or polygonal section as in fair finished surfaces complete all as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beams, lintels, over 1.5 m span, cantilevers, shelves including supports, overhangs etc. complete all as specified and directed as in flat and fair finished surfaces complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for precast cement concrete type 1:3:6 type C-1 (20mm graded stone aggregate) block masonry with solid blocks exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed.
M&L rendering 15 mm thick in CM 1:4 on brick/concrete wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L rendering 10 mm thick in CM 1:4 on brick/concrete wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick or concrete wall etc including racking out joint hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L rendering 15 mm thick in CM 1:4 with WPC @ 3% by weight of cement on brick/concrete wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. (Note cost of WPC is included in quoted rate against this item)
M&L preparing new surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and directed.
M & L preparation of newly plastered surfaces of walls and applying two coats of exterior emulsion paint (weather coat) over a coat of alkali resistance primer complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated / semi corrugated / trapezoidal profile sh steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed
M&L 300 mm wide Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in plain angular ridge fixed with self tapping screws as specified complete all as specified and directed.
S&F 1.25mm thick steel rolling shutters, with out ball baring, as specified including top cover anchoring rod, hasp and staple, shaft, pipe, brackets, and one shop coat of primer, erected in position as indicated complete with bevel gear box, connecting rod and crank handle complete all as specified and directed.
S&F steel work in tubular pole including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 all as specified and directed.
M&L for structural steel work as in roof truss (framed), trussed, purlins, rafter, rails and fastenings and heavy bracket framing (Beam, Tee, Angle, Channel or flat sectios) including distance pieces, cleats etc.confirming to Fe-410-W(Gde-E-250) quality A complete all as specified and directed.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed.
M&L for removal of existing membrane of roof treatment,water proofing treatment at parapet / vertical walls, cleaning the concrete / plastered surface, removing dirt and debris, making defective locations and removing loose concrete plastered surface by careful stripping untill hard surface is exposed, cutting the concrete / plastered surfaces to regular shape, wire brushing the exposed surface and removing debris outside ND(V) area complete all as specified & directed
Brushing neat cement slurry @ 3.0 Kg of cement per sqm all as specified and directed for bonding between old and new concrete.
M&L 25 mm thick (av Thickness) PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in padding over roof and finishing the surfaces fair and even without using extra cement all as specified and directed.
M&L water proofing treatment on cleaned RCC roof comprises with the following operation as specified here-in-below :- (a) 10 mm thick (av. mimimum thickness) plastering in cement mortar 1:3 mixed with liquid water proofing compound @ 3% by weight of cement & finishing the plastered surfaces even and smooth over cleaned RCC roof. The plastered surface shall be cured properly for ten days by ponding of water over roof. (b) After drying the surface, apply bitumen primer of density at 25°C, 0.87 to 0.89 kg / Liter and viscosity 70-160 cps over the plastered surface @ 0.40 Ltr / Sqm. The manufacturer of primer shall be the same membrane manufacturer (c) Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt make as approved over the primer coat. Membrane shall be laid using butane torch and sealing all joints etc all as per Para 11.44.5 of SSR Part I. (d) Applying one coat of Aluminium paint @ 0.1 ltr per Sqm over APP based polymetric membrane complete all as per manufacturer's instruction.
M&L water proofing treatment on vertical surfaces like. parapet walls etc. comprises with the following operation as specified here-in-below :- (a) 15 mm thick (av. mimimum thickness) plastering in cement mortar 1:3 mixed with liquid water proofing compound @ 3% by weight of cement & finishing the plastered surfaces even and smooth over cleaned surfaces. The plastered surface shall be cured properly for ten days . (b) After drying the surface, apply bitumen primer of density at 25°C, 0.87 to 0.89 kg / Liter and viscosity 70-160 cps over the plastered surface @ 0.40 Ltr / Sqm. The manufacturer of primer shall be the same membrane manufacturer (c) Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt make as approved over the primer coat. Membrane shall be laid using butane torch and sealing all joints etc all as per Para 11.44.5 of SSR Part I. Primer & the membrane shall be inserted in the groove & the groove shall be sealed with cement mortar 1:3 mixed with liquid water proofing compound @ 3% by weight of cement (d) Applying one coat of Aluminium paint @ 0.1 ltr per Sqm over APP based polymetric membrane complete all as per manufacturer's instruction.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified & directed
Taking down rain water pipes (any size or pattern) including all fitings, heads, shoes, bends iron necks etc complete all as specified.
S&F 160 mm dia PVC (SWR) pipes single, socketed, in any length with rubber ring joints fixed to wall complete all as specified and directed
S&F 160 mm bore PVC (SWR) bends (any radius) complete all as specified and directed.
S&F rotational moulded polythylene water storage tanks (cylindrical, vertical with closed top) hoisted and fixed in position of 1000 Ltr capacity all as specified in SSR and as directed.including taking out old tank complete all as specified & directed
Taking down 20mm bore GI tubing and connections including cleaning for refixing complete all as specified and directed.
S & F 20mm bore GI tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed including taking down old one.
S&F ball valve 20mm dia high pressure with polythene float and flynut complete all as specified and directed including taking down old one.
[SCHEDULE 'A' PART-II [E/M WORKS]
M&L point wiring surface type with 1.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable 1100 Volts grade drawn through with and including MS stove enamelled, black crigid conduit medium grade, with all fittings and accessories of MS conduit (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core FRLS copper cable as earth continuity wire
connecting to common earth point including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for one light / fan / bell / bazzer point controlled by one one way switches complete all as specified and directed. (Note : Necessary chase cutting if requires, shall be measured & paid separately under respective items in this schedule)
M&L point wiring concealed type with 1.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC rigid conduit with all fittings and accessories of PVC rigid conduit (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core FRLSH copper cable as earth continuity
wire connecting to common earth point including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for one light / fan / bell / bazzer point controlled by one one way switches including necessary cutting for sinking boxes and making good to walls, floors etc.complete all as specified and directed. (Note :necessary chase cutting for conduits shall be measured & paid separately under respective items in this schedule)
M&L point wiring with two runs of 2.5 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through MS stove enamelled rigid conduit with all fittings and accessories of steel conduit complete fixed to wall / ceiling etc including one run of 2.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed. (Note :-(i) Steel rigid conduit with all fittings/accessories shall be measured and paid separately. (ii) Two runs of 2.5 sqmm single core cable, one run of 2.5 sqmm earth continuity wire to be measured as one length (iii) chase cutting if required shall be measured and paid separately under relevant items in this schedule.).
M&L point wiring with two runs of 4.0sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through MS stove enamelled rigid conduit with all fittings and accessories of steel conduit complete fixed to wall / ceiling etc including one run of 4.0 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed. (Note :-(i) Steel rigid conduit with all fittings/accessories shall be measured and paid separately. (ii) Two runs of 4.0 sqmm single core cable, one run of 4.0 sqmm earth continuity wire to be measured as one length (iii) chase cutting if required shall be measured and paid separately under relevant items in this schedule.).
M&L point wiring with two runs of 6.0sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through PVC rigid conduit with all fittings and accessories of PVC rigid conduit complete fixed to wall / ceiling etc including one run of 6.0 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed. (Note :-(i) PVC rigid conduit with all fittings/accessories shall be measured and paid separately. (ii) Two runs of 6.0 sqmm single core cable, one run of 6.0 sqmm earth continuity wire to be measured as one length (iii) chase cutting if required shall be measured and paid separately under relevant items in this schedule.).
Supply only 20 mm dia MS stove enamelled, black crigid conduit medium grade, with all fittings and accessories of MS conduit (like Tee, bend etc.) complete all as specified and directed.
Supply only 25 mm dia medium grade MS stove enamelled, black crigid conduit medium grade, with all fittings and accessories of MS conduit (like Tee, bend etc.) complete all as specified and directed.
Supply only 25 mm dia medium grade PVC rigid conduit with all fittings and accessories of PVC RIGID CONDUIT (like Tee, bend etc.) complete all as specified and directed.
M&L cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps cills, sunshades, shelves, lintels etc. in brick walls and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc. 10 cm girth complete all as specified & directed.
S & F switch piano, flush type, 5/6 Amps, 240 Volts, single pole, one way, conforming to IS complete all as specified and as directed.
M & L Ceiling rose, surface type polycarbonate/ PVC three terminals, conforming to IS, complete all as specified and as directed.
S&F Flame Proof weather proof rotary switch 16A,2pole with separate cable termination box all specified and directed Make:-Cat Part No.SSPL/RI/1010 Shyaam or equivalent in Sudheer complete all as specified and as directed.
S&F LED flameproof fitting for twin a T8 tube of 16W with retro LED tube all as specified and directed.
Supply and fix LED building security light 45 watt complete all as specified and directed.
S&F SP MCB 6 to 32 Amps C Curve complete all as specified and directed.
S&F SPN MCB 6 to 32 Amps C Curve complete all as specified and directed.
S&F doubledoor SPNDB 4 way double door with 200 Amp rated bus bar all as specified and directed.
S&F ceiling fan single phase in Cast Aluminium LM6 Size 36'' complete all as specified and as directed.
Supply & fix LED batten with CRCA body,pre coated with white and prewired suitable for LED tube 2x18/20 watt 4'long alongwith 2 number of tube complete all as specified and directed. Make:- Bajaj Cat Part NoBLRBDB-218 and BLRB20CW LED
S&F flame proof exhaust fan AC single phase 230/240V of size 457mm sweep with louver complete all as specified and directed. Make :- Havells/ Bajaj/Orient..
M&L for cutting hole for exhaust fan of size 6" and finish it with cement sand plaster 1:6 complete all as specified and directed.
Taking out Aluminium ofstrip 25mm x 4mm & refixing the same with new saddles, clamps and fixing screws complete all as specified and directed.
Taking down 50 mm bore GI tubing and connections including cleaning for refixing complete all as specified and directed.
Taking down 40 mm bore GI tubing and connections including cleaning for refixing complete all as specified and directed.
Taking down 25 mm bore GI tubing and connections including cleaning for refixing complete all as specified and directed.
S & F 50 mm bore GI tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F 25 mm bore GI tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 50 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed including taking down old one.
S&F 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed including taking down old one.
Supply & fix Air termination single pointed aluminum rod 12 mm dia and 300 mm long including taking down old unserviceable one complete all as specified and as directed including taking out old one
Removing central AC cooling tower of capacity 7.5 TR and refixing it in original position after roof treatment work with complete connections complete all as specified and as directed.
M&L for disconnecting cable of size upto 50 Sqmm and taken out from wall & cleaning trench/duct/wall and relaying cable with proper clamp and connection complete all as specfied and as directed.
Material & labour for PCC (1:2:4), type B1 (using 20 mm graded stone aggregate) as in pillar to support the pipe lines including necessary form work and finishing the exposed surfaces of concrete fair and even all as specified and directed
S N N INFRAS
PNR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .