Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 12 GURU NANK AUTO MARKET KASHMERE GATE DELHI 110006 | NORTH | DELHI | 110006 | Admitted-Finance |
| 2 | Admitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹3,600
Closing Date
13 Jul 2022, 11:30 amClosed
EEEANDMM-5
EEEANDMM-5 NEAR KANHIYA NAGAR METRO STATION DELHI-35
Replacement of existing APFC panel at Hindu Rao Hospital BPS.
2022_DJB_225681_4
NIT NO. 07 (2022-2023)
Open Tender
Miscellaneous Services
Item Wise
30 days
EEEANDMM-5
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
₹3,600
15 Jul 2022
7 Jul 2022
13 Jul 2022
7 Jul 2022
13 Jul 2022
7 Jul 2022
MCCB with Thermal Magnetic Release of 160-200 A ,TP 440V 25KA with Spreader Terminals and Handle/Direct ROM Make-L&T /Seimens/Havells/C&S/DJB approved
Power Contactor TP 220/440V ac 25A Make- L&T/Schneider/DJB approved
Power Contactor TP 220/440V ac 32A Make- L&T/Schneider/DJB approved
Automatic Power Factor Correction Relay/APFC Controller-1CT 415 V digital type 8 step 144x144mm make – L&T/Seimens/BHEL/DJB approved
Digital LED Ammeter 220V AC 03 Ph+ASS Make-L&T/Schneider/Seimens/DJB approved
Digital LED Voltmeter 220V AC 03 Ph+VSS Make-L&T/Schneider/Seimens/DJB approved
Indicator / Indicating light LED Type 22.5 mm 220V AC R.Y.B. Make-L&T/Seimens/DJB approved
Flush Head Push Button Red /Green/Blue Make- L&T/Seimens/DJB approved
SP MCB 6A-32A C-Curve Make-L&T/Seimens/BHEL/DJB approved
Cylindrycal Shunt Capacitor Power 03 Phase, 440V AC, 50 Hz Heavy Duty in suitable Banking as per requirement to maintain Power Factor (60 kVar * 01 No. APFC Panel Make:-L&T/Seimens/BHEL/DJB approved
MCB of 32A, Three Pole,415V AC 03 Phase 50 Hz 10KA-15KA C-Curve make-L&T/Seimens/BHEL/DJB approved
Current Transformer Resin cast 150/5 for Current Measurement CL-01, 15VA Make:- AE/Kappa/DJB approved
Sensing Current Transformer of suitable ratio of Incomer for Current Sensing Make:- AE/Advance/Kappa/DJB approved
Aluminium Bus Bars, Links, Bends Sets Dully Sleeved with Heat Shrinkable Sleeve Suitable for 160-250 AMP Current Carrying Capacity in suitable Cross Section.
PVC Insulated Flexible Copper Conductor Control Wire, 2.5 sqmm as per site requirement Make-Havells/Gloster/Grandley/DJB approved
PVC Insulated Flexible Copper Conductor Control Wire, 10 sqmm Make-Havells/Gloster/Grandley/DJB approved
Supply of PVC Insulated and PVC Sheathed Aluminium Armoured Heavy Duty XLPE Insulated LT Power Cable of 1.1 KV grade of size 3.5 core*95 sqmm from Main Switch to APFC Panel Make:-Havells/Gloster/Grandley/DJB approved
S/O Fabricated APFC Panel Totally Enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .the each part of the fabricated panel will be strictly subjected to Seven Tank Treatment. Enclouseure in 1200mmx1200mmx350mm (w*l*d) 1.6/2.0 mm CRCA sheet, as suitable to fix the above mentioned capacitor Banks & Switchgears to be fitted and with provision of Cable Entryy & Base Frame Made out of MS Channel Angal Stand Size 40x40x5mm to fix the APFC panel.
Dismentling of old panel & shifting the same to JE Store as per Engineer in charge,where required. Installation of New APFC Panel at site with required Hardware to complete the job & Old material including all loading/unloading/fraight/cartage cahrges of New and Old materials.
Testing and Commissioning of the all installed component in APFC Panel and setting of APFC Relay to get proper Power Factor, Testing and Commissioning of the APFC Panel with relevent is as follow:- A. Check equipments specifications. B. continuity and ear thing. C. Mccb mechanism and alignment. D. Meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth. E. Test of all functions F. Checking of all tightness of nuts and bolts. G. Setting of apfc relay parameters to achieve target pf 0.98 or above. H. Alignment of doors etc. I. Interlocking tests. As per the satisfaction of the engineer in charge
Agarwala Traders
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .