Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹39.9 L+₹78,969.22 (2.02%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹41.3 L+₹2.3 L (5.80%)Rejected-AOC GOALAPARA MONIRAMPUR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 WB | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹48.4 L+₹9.3 L (23.8%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹54.1 L+₹15.0 L (38.5%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹45.4 L
EMD Value
₹90,700
Closing Date
28 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
Commander Works Engineers (Sub) Military Engineer Services PO- Barrackpore Dist- 24 Pgns (N) Kolkata- 700120 (W.B)
PROVN OF GEYSERS WITH CONNECTION IN JCOs AND OR MARRIED ACCN AT BARRACKPORE UNDER GE BARRACKPORE
2022_MES_504245_1
CWE/BKP/48 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
GE BARRACKPORE
CLASS D CATEGORY b(i)
6 documents required · 6 mandatory
₹500
GE BARRACKPORE
₹90,700
Yes
14 Mar 2022
28 Jan 2022
2 Mar 2022
28 Jan 2022
28 Feb 2022
15 Feb 2022
60 days
Amount
M&L for point wiring complete with 2.5 sqmm PVC insulated, FRLSH type, ISI marked, conforming to IS-694/1990 unsheathed, multi-stranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade(MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of and including white/Silver/Dark bronze colour modular blanking plate as per number of switch modules flush mounted for fixing of modular switches, sockets, fan regulators, blank plate etc. and including above mentioned colour modular plate cover of required modules and including 2.5 Sqmm PVC insulated multi-stranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly one power point controlled by MCB SP 20Amps and including making good the disturbed surfaces to match with existing surface and colour shade with putty for smooth finishing complete all as specified and directed for the following:- Note:- All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers and all modular electrical fixtures are to be used of same make/brand only. Cutting & chasing work at any height shall deemed to be included in quoted rate only.)
S&F in repair suitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed. Make:- Legrand/Hager/Havells or as approved make.
Fixing only electric water heater, storage type steel body with copper inner tank and heating element upto 2KW and capacity 25 litres, BEE 5 star rated , vertical type 240 volts , AC, 50 Hz and fixing arrangement on wall including providing hold fastners-04 Nos Anode rod, PUF insulation, 0.8 MPa high working pressure, shock safe plug with IPX protection and including necessary plumbing work, testing all as specified and as directed. Note: Material shall be supplied by the department as free for fixing under Schedule 'B'.
M&L for GI Tubes 15mm "medium grade", galvanised, with all fitting and fixed complete to walls and ceilings concealed type or laid in floors wall etc.all as directed.
S&F 15mm bore Bib taps, cast copper alloy with crutch or butterfly handles, screwed down,screwed for iron pipe or for brass ferule, chromium plated fancy type for complete all as directed.
S&F 15mm bore stop valves, cast copper alloy with crutch or butterfly handles, screwed down, high pressure , with cluth or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type complete all as directed.
S&F for PVC connection 15 mm size with PTMT nuts of length 600 mm. complete all as directed.
S&F in repair TPN distribution board 4 way acrylic double door 415 volts AC, TPN for flush mounting with 100 Amps copper bus-bar, neutral bar, earth bar and MCB incomer of rating upto 100 Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removal gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coated complete all as directed and as directed. Make- Legrand/Hager/Havells.
S&F in repair MCB FP.63 to 100amps 10 KA, 415 volts, 50 Hz, 'B' curve including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed. Make:- Legrand/Hager/Havells or as approved make.
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked, FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such as Bend, Tee, Elbow, Short Engr-in-Charges etc. concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multi stranded, 1100 volts grade, ISI marked FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unserviceable sub-main wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
S&F MCB SPN 32 to 40 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked complete all as specified and directed. Make:- Legrand/Hager/Havells or as approved make.
S&F MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked complete all as specified and directed. Make:- Legrand/Hager/Havells or as approved make.
M&L earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised earth lead wire 4.0 mm dia from earth electrode to test point/equipment or up to 7.5 metres whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Part-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, RCC cover 1:2:4 type B1, including excavation/earth work in any strata and returning filling, removal of surplus soil and testing for required value including taking out old earthing complete all as specified and directed.
M&L for earth continuity strip 4 mm GI wire galvanised iron strip including taking out complete all as specified and directed.
Supply, installation, testing and commissioning step down transformer voltage rating HT11/0.433 KV (11KV on HT side and 433 volts on LT side), outdoor type, of capacity 400KVA, Energy efficiency level-02, 3 Phase, 4 Wire, 50 Hz, oil cooled , core type , floor mounted , Delta/star connected maximum losses as defined in vector group DYN 11, double copper wound ONAN manual type off load tap changing facility on HT side to vary secondary voltage from minus 10.00 % to plus 5.00 % in four steps with a steps of + 2.5 % continuous rating of capacity 400 KVA including cable box on both HT & LT side .The transformer shall be completed with all standard fittings and accessories, gauges, with first filling of transformer Oil upto indication level etc. and confirming to IS :1180 or latest IS, fittings and accessories of transformers shall confirm to IS 1180:2014 and as amended and duly mounted on rollers as per load bearing capacity of transformer and the transformer shall have the following fittings/accessories fitted complete all as specified and directed. Notes :-(a) Rating plate and terminal marking plate of HT/LT sides (b) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing. (c) Lifting Lugs (d) Dehydrating silica gel breather (e) Oil level indicator with minimum and maximum marking (f) Cooling Radiator pocket (g) Thermometer pocket (h) Drain valve with plug or cover plate (j) Conservator tank (k) Oil filling hole with cover including funnel (l) Air release device (m) Thermometer 100 mm dia/stem type with metal guard having maximum temperature indication with resetting devices for transformer (n) Winding temperature indicator (o) Air release device for transformer Note :- (i) Information plate /Technical data plate will be obtained as per IS..
Supply, install,, testing and commissioning of factory fabricated, CPRI approved with IP-54 Protection LT panel board of size (1200 x 1200 x 500) mm suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, outdoor type, made out of 3.15 mm thick CRCA sheet including powder coated. Cubicle, floor mounted, free standing, dust and vermin proof, air ventilation. Panel board shall have front and rear opening with hinged doors and rubber gaskets, handles, industrial type locking arrangement, cable alleys, bus bar chamber and switch gear compartment, bottom cable entry holes for incoming and outgoing cables, earthing terminals, affixing danger notice plate, each compartment shall be numbered/lettered for indication, aluminium bus bar TPN 600 Amps capacity duly covered with heat shrinkable sleeves colour coded duly fixed on DMC/SMC insulators housed in a separate bus bar chamber and control wiring with PVC insulated, milt stranded flexible copper conductor cables of adequate size and length, protection fuses, MCBs, connectors, LED phase indication lamps (RYB) etc. incoming and outgoing MCCBs shall have extended bus bar links and mounted on suitable size MS angle iron frame (50 x 50 x 6)mm x 600 mm duly painted also including provision of PCC : 1:2:4 type B1 (using 20 mm graded stone aggregate) as in foundation/platform etc as per manufacturer designed subject to approval of GE to suit the site requirement, and including taking out old item complete al as specified and directed and comprising of following:- (i) MCCB 400Amps - 4 Pole, 415 Volts, 50 Hz, - One (ii) MCCB 250Amps - 4 Pole, 415 Volts, 50 Hz - One (iii) MCCB 63A, 4Pole, 16KA, 415Volts, AC, 50 Hz thermal setting fixed-02 Nos. (iv) Aluminium bus bar TPN 600 Amps capacity - 1 set (v) Digital Voltmeter with VSS- 01 No (vi) Digital Ammeter with CTs & ASS - 01 Set (vii) LED indicator lamps RYB - 01 Set (viii) CT 400/5A (Set of 3 Nos) Make of Panel : LT panel shall be procured by the contractor from CPRI approved /certified manufacturer.
Disconnecting all electrical connections and earth strip at existing transformer all connected accessories/cables and shifting of 11 KV/0.433 Volts up to 100 KVA to 315 KVA capacity transformer and transportation safely by hydra/ lifting vehicle and including providing suitable carrying vehicle from DODA /BI line/TCP & MES Yard to MES yard and once again shifted from DODA /BI line/TCP & MES Yard to required places and making all electrical connections properly with earth strip etc and re connected with the shifted transformer after servicing /overhauling of transformer and testing and including providing functional accessories such as nuts,bolts,washers, lugs, sleevs etc and megger testing and complete all as specified and directed. Note:- During shifting of transformers including providing safety measures/ tools/ plants/ lifting & carrying Vechicle etc. any accidental damages/ breakages in transformers and the contractor will be fully responsible and will make good the same to the entire satisfaction of Engr-in-Charge with out extra cost. to the department.
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size (32 X 6) mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1, RCC cover 1:2:4 type B1, including excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value including taking out old item complete all as specified and directed.
M&L for XLPE insulated, LT armoured electric cable with aluminium standed conductor 1100 volts grade, cross-sectional area 185 sqmm and 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands,nuts,bolts and washers etc. and testing and including taking out complete all as specified and directed. Note:-Excavation,Earth work,sand cushioning,cable covers and cable protection pipes etc. shall be measured and paid separately.
All as per Srl Item No. 19 here-in-before but cable of size 95 Sqmm and 3.5 core
All as per Srl Item No. 19 here-in-before but cable of size 25 Sqmm and 4 core
Supply and laying brick sub class 'B' 250mm x 125mm x 75mm and laid in trenches as in protection of UG cable complete all as specified and directed.
M&L GI pipe 50 mm "light grade" laid in trenches floors/on, pole/road for cable protection with all fittings complete all as specified and directed .
Boaring holes horizontally under road without damaging the surface of road (minimum 1.0 Mtr below the road surface) with the help of GI tubing of dia not exc 100mm for passing of UG cable all as specified and as directed.
Supply and Filling sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified and as directed. (Note : Punned thickness will be measured for payment.)
Excavation in trenches not exc 1.50 m wide and n exc 1.50 mtr in depth; for foundation etc. not exc 10 sqm on plan and getting out in soft/loose soil etc complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft/ loose soil etc complete all as specified and as directed.
Removing excavated materials (soils) to a distance not exc. 50 mtr and depositing where directed at level not exc 1.5 m above the starting point etc complete all as specified and as directed.
CHANDRA CONSTRUCTION & CO.
JADAV CONSTRUCTION
BUSINESS SYNDICATE
N C DUTTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .