DEPUTY EXECUTIVE ENGINEER, MEHSANA ELECTRICAL (R&B) SUB DIVISION, MEHSANA
Replacing old Water cooler at Library building & R & B circle office at Mehsana, Dt.Mehsana [2nd attempt]
356662
13/02 OF 2026/2027
Open
Electrical
Works
Mehsana
7 documents required · 7 mandatory
₹600
Executive Engineer, Mehsana Electrical (R&B) Division, Mehsana
₹1,400
18 Oct 2026
18 Oct 2026
18 Oct 2026
3 Nov 2026
18 Oct 2026
120 days
Name of Work:-Replacing old Water cooler at Library building & R & B circle office at Mehsana, Dt.Mehsana
SR NO. Quantity Perticulars Rate at which the materials Place of delivery
will be charged to the
Dy.Executive Engineer, Executive Engineer,
Mehsana Electrical Sub DN Mehsana Electrical (R&B) Division
Mehsana Mehsana
Name of Work:-Replacing old Water cooler at Library building & R & B circle office at Mehsana,
Dt.Mehsana [2nd attempt]
Quantity Item Description Rate in Figure & Word Amount
Replacing old burrnout Mians by Providing and erecting
Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of
pipe to be erected in / on wall / ceiling with 2.5 sq. mm
1 20 Mtr. 140.39 Forty Paise
copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories
(a) 2 wire 4 sq. mm
Replacing old burrnout Accessories by Providing and
erecting following type of Modular Type Accessories
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate , modules erected with
necessary connections as per site situation directed by
Engineer In charge.
1 Nos (9) 16 Amp. SP one way switch Cat.III 180.79 Eighty Paise
1 Nos (10) 6/16Amp. Universal socket Cat.III 199.98 Ninety Nine
providing and erecting Approved make RCCBs
conforming to IS: 12640 and having sensitivity of 30 mA
and Short Circuit withstand capacity of 10 KA and
suitable for operation on single phase 240 V,50Hz.
3 1 Nos 2458.34 hundred
having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic
component. for following Max. rating erected as
directed (ii) 40Amps. DP cat-III
Sheets steel powder coated enclosure suitable for Seventy Six
incorporating One/Two nos. MCB. Paise
Replacing old unrepairable cooler by Providing &
erecting water cooler having storage capacity 150 Ltr. &
cooling capacity 150 Ltr.per hour @ an ambient temp of
45˚ C. The outlet temp. of the water should drop by
15˚C within a hour, The water cooler should be
5 2 Nos 61482.74 hundred
comprising of hermetically sealed compressor, fan
motor, condensing unit, water tank surrounded by
evaporating, coil, thermostats, relay etc.complete with
necessary inlet & outlet connection. The body of water
cooler will be made from Stainless Steel.
Providing , erecting , fabricating the M.S. structure as
per requirement on site incorporating proper size of Rupees
M.S. angles,square,round, flats, bars, channels, sections Seventy
6 30 kg complete with cutting, welding, grinding & finishing duly 77.77 Seven Paise
painted with one coat of red oxide with erection on site Seventy
as per direction of engineer in charge with necessary Seven Only
grouting, cementing, plastering & finishing complete.
Total Amount put to tender Rs.
Total Amount put to tender Rs.
Rupees One Lakh Thirty One thousand One hundred
Twenty Two Paise Twenty Four Only
I / We am / are willing to carry out the work at ________________________
written in figures and words )
below / above the tendered rates mentioned above.
Amount of my / our tender works out as under :-
Estimated amount Estimated amount
put to be tender Rs. _____________ put to be tender Rs. _____________
Deduct ______% below Rs. _____________ Add ______% above Rs. _____________
In words :- In words :-
* Please strike out whichever is not applicable.
1. I / We hereby declare that I / We have visited the site and fully acquited myself / ourselves
with the local situtaion regarding materials, labour and other factors pertaining the work
before submeeting this tender.
2. I / We hereby declare that I / We have carefully studied conditions of contractors,
specifications and other the tender documents of this work and agree to work execute that
same accordingly.
Executive Engineer,
Dy.Executive Engineer, Mehsana Electrical (R&B) Division
Mehsana Electrical( R & B ) sub. Div. Mehsana
Dismental Material List
Name of Work:-Replacing old Water cooler at Library building & R & B circle office at Mehsana,
Dt.Mehsana [2nd attempt]
SR ITEM DETAILS QTY UNIT DIM % Amount
1 Cost old burrnout Mains 2 core 4 sqmm 20 Nos. 131.00 9.00% 11.79
2 Cost old burrnout Accessories 1 Lot 10.00 Lum 10.00
3 Cost old unrepairable water cooler 80 Ltr 1 Nos. 53695.00 7.00% 3758.65
4 Cost old unrepairable water cooler 150 Ltr 1 Nos. 60408.00 7.00% 4228.56
TOTAL AMOUNT RS.=
TOTAL AMOUNT RS.=
Say Total Amount Rs.=
Say Total Amount Rs.=
Dy.Executive Engineer, Executive Engineer,
Mehsana Elect. ( R & B ) sub. Div. Mehsana Elect.( R & B ) Division
Mahesana. Mehsana.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
G S T LTR.pdf
GR.pdf
NOTICE NO 13.pdf
PQ CRETERIA.pdf
schedule a b and dm.pdf
STANDARD BIDDING DOCUMENTS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .