Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC | L1 | Accepted-AOC L1 being lowest | |
| 2 | L2₹31.3 L+₹85,575 (2.81%)Rejected-AOC PLOT NO 4 NAYA GAON HARIPUR KANWALI P O SEEMADWAR DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC being not lowest | |
| 3 | L3₹31.6 L+₹1.1 L (3.62%)Rejected-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L3 | Rejected-AOC being not lowest | |
| 4 | L4₹35.1 L+₹4.7 L (15.3%)Rejected-AOC DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC being not lowest | |
| 5 | L5₹36.4 L+₹5.9 L (19.3%)Rejected-AOC 31 SARASWATI SONI MARG DEHRADUN | DEHRADUN | L5 | Rejected-AOC being not lowest |
Tender Value
Refer Docs
EMD Value
₹63,000
Closing Date
1 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HILLS
Headquarters Commander Works Engineers (Hills) Military Engineer Services, Mall Road, Dehradun Cantt
REPAIR TO ROOFING CEILING ETC IN ZONE C D AND OTHER LOC AT MIL STATION RAIWALA
2021_MES_409382_1
86309/RWL/E8
Open Tender
Civil Works
Item Rate
150 days
AGE(I) RAIWALA
Class D cat a i
9 documents required · 9 mandatory
₹500
AGE(I) RAIWALA
₹63,000
Yes
20 Feb 2021
4 Jan 2021
3 Feb 2021
4 Jan 2021
1 Feb 2021
18 Jan 2021
5 Jan 2021 - 9 Jan 2021
60 days
Amount
M&L of water proofing treatment to non-accessible roof slab with poly urea based water proofing liquid membrane as per manufacturer’s instructions with following course of description below :- (a) Removal of existing roof treatment , open up RCC slab grinding of existing bitumen primer including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material. (b) Surafce preparation with cracks reparing, cracks shal be filled using dual shrinkage compensated Repair Mortar and dried for 72 hours before laying the membrane. (c) Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners.with cement concrete 1:2:4 (Using 12.5mm stone aggregate) mixed with and including liquid polymer @ 1.5 Litre per 50 Kg bag of cement. (d) Application of one coat of Epoxy Primer in ratio of 1:3 (Resin : Hardener) on the cleaned surface for bonding of liquid membrane with the existing concrete surface. (e) Application of two coat of High build elastomeric waterproofing coating of two component hybrid Polyurea polyurethane applied as a waterproofing liquid membrane. (f) After the complete application of treatment, the roof will be tested for water tightness by ponding with water 72 Hours for any seepage, if observed the rectification will be carried out by pressure grouting under the pressure of 5kg/sqcm using cement based cement grout. After the surface is repaired, the slab will be tested for water tightness again Note :
1. The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Removal of existing roof treatment , open up RCC slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material. (b) 20 mm thick plaster in CM 1:4 mixed with and including liquid polymer @ 1.5 Litre per 50 Kg bag of cement. will be applied over the roof slab. (c) Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners.with cement concrete 1:2:4 (Using 12.5mm stone aggregate) mixed with and including liquid polymer @ 1.5 Litre per 50 Kg bag of cement.mixed with polymer compound for water proofing as per manufacturer instructions (d) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/SM on prepared surface, till the surface is property impregnated. (e) Providing APP based 5 layer polymeric membrane minimum weighing 3 Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by torch applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer and seling it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (f) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance
1. The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
Dismantling Plain or corrugated steel sheeting any gauge , thickness , including Nanital or similar pattern roof coverings complete all as specified and directed.
Dismantling Asbestos cement (corrugated, semi corrugated, etc) sheets in roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed .
S&F in repairs 15 mm bore steel water tubing medium grade galvanised (ISI MARKED) with all fittings ( heavy duty ISI MARKED) and fixed complete to walls and ceiling or laid in floor etc,complete all as specified and directed.
S&F in repairs 20 mm bore steel water tubing medium grade galvanised (ISI MARKED) with all fittings ( heavy duty ISI MARKED) and fixed complete to walls and ceiling or laid in floor etc,complete all as specified and directed.
S&F in repairs Rotational moulded polyethylene water storage tanks 1000 Ltr capacity triple layered (cylindrical vertical with closed top) (ISI MARKED) hoisted and fixed in position all as specified in SSR Part I including ball valve .complete all as specified and directed.
S&F in repair 20 mm gun metal,globe or gate valve,(ISI MARKED) with iron wheel head , screwed both ends for iron pipe .complete all as specified and directed.
S&F 0.63 mm thick galvanised , corrugated mild steel sheeting (ISI MARKED) in roof with two corrugations side lap fixed with L-type or J-type or cranked hook bolts, in roofs/ walls etc with grade of zinc coating 275 complete all as specifed and as directed.
All as per item 13 above but except sheets , any thickness and providing & fixing with new ‘L’ or ‘J’ type hook and washers.
S&F for 0.63 mm thick plain galvanised mild steel sheeting (ISI MARKED) using grade ‘O’ sheets with 120 gm Zinc (Spelter) coating Per Sqm both sides inclusive, as in ridges, hips, valley gutters, drip and straight flashing fixed with ‘L’ or ‘J’ type hook and washers complete all as specified and directed.
Taking down cement or cement lime plaster on Brick or stone walls, etc incl racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 mixed with and including water proofing compound acrylic repair polymer on brick or concrete surfaces of projected cup board exterior surfaces , finishing the surface even and smooth without using extra cement complete all as specified and directed. (Note :- The work is required to be carried out upto double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers. The rates quoted shall deemed to be included for these items.)
M&L for brickwork with subclass 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 including demolition of Brickwork or stone/boulders masonry built in cement morta complete all as specified and directed.
M&L of water proofing treatment to exterior surface of projected Cup board with poly urea based water proofing liquid membrane as per manufacturer’s instructions with following course of description below :- (a) Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) to ease up about corners.with cement concrete 1:2:4 (Using 12.5mm stone aggregate) mixed with and including liquid polymer @ 1.5 Litre per 50 Kg bag of cement. (b) Application of one coat of Epoxy Primer in ratio of 1:3 (Resin : Hardener) on the cleaned or cement plastered surface for bonding of liquid membrane with the existing concrete surface. (c) Application of two coat of High build elastomeric waterproofing coating of two component hybrid Polyurea polyurethane applied as a waterproofing liquid membrane. 1. The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer only 2. The work is required to be carried out upto double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers. The rates quoted shall deemed to be included for these items.)
M&L for preparation of new plastered surfaces and applying two coats of cement base paint of approved shade on walls over a coat of primer all as specified & directed by Engineer-in-Charge
M&L for complete removal of old paint on steel surfaces of roof sheet by paint removers or by burning off by blow lamps and cleaning with scrapers, any numbers of coats etc and preparation of previously untreated surface of steel and iron over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed
M&L second class hard wood( SAL), wrought, in framed and fixed,, in repairs, in scantlings to replace old and decayed timber (including piecing, scarfing etc of old and new timbers if required) in roof truss, rafters and purlins in any position complete all as specified and directed
S&F, in repair, Rolled MS section as in main and cross beams hip and jack rafters,purlins where connected to common rafters and running railsfixed with angle cleats or other connectng plates etc Fe 410 (Gde E-250 quality A) complete all as specified and directed
Fixing only MS flat iron any size as in wind tile for roof including securing bolt. (Old wind tie received from taking down will be reused).
M&L in repairs for 12mm thick Gypsum board suitably placed in false ceiling complete all as specified and directed.
M&L as in repair "E" board false ceiling 4 mm thick with GI framed work with main tee of size 24X28.5 mm made out of PGI sheet 0.3 mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25 mm thick and wall angle 24X24X0.45 mm powder coated for celing , ceiling board 60cmX60cmX4.0 mm thick , suspended with GI wire 2 mm dia & upto 2 M average length with adjustable device complete including plugging in brick /stone wall with steel rawal plugs@ 600 mm C/C . Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides and painted with two coats of Acrlic distemper tint as approved by GE/AGE including making good all the disturbed portion , complete all as specified and directed.
sweety pest control
Alankar Traders
TARUN ENGINEERING WORKS
M/s RP AGRAWAL
Malik Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .