Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹2.3 Cr | L1 | Accepted-AOC Being L1 and found in order |
| 2 | L2₹2.3 Cr+₹49,851 (0.22%)Rejected-Finance | ₹2.3 Cr+₹49,851 (0.22%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹2.3 Cr+₹9.1 L (4.02%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹2.3 Cr+₹9.1 L (4.02%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹2.4 Cr+₹13.9 L (6.16%)Rejected-Finance | ₹2.4 Cr+₹13.9 L (6.16%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹2.7 Cr+₹43.5 L (19.3%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹2.7 Cr+₹43.5 L (19.3%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹2.5 Cr
EMD Value
₹3.2 L
Closing Date
6 Mar 2024, 6:00 pmClosed
Chief Engineer
Headquartes Chief Engineer Bareilly Zone Bareilly
RENEWAL REPLACEMENT OF EM MISC ITEMS AGAINST BER UNDER GE WEST BAREILLY
2024_MES_637492_2
CEBZ/BLY/T-14 OF 2023-24
Open Tender
Civil Works
Item Rate
270 days
BAREILLY
AS PER NIT
8 documents required · 8 mandatory
₹2,000
GE West Bareilly
₹3.2 L
Yes
15 May 2024
13 Feb 2024
13 Mar 2024
13 Feb 2024
6 Mar 2024
21 Feb 2024
13 Feb 2024 - 20 Feb 2024
Amount
Taking down / dismaintling / disconnection of AC Split/Window of any cap from Wall Window etc from its oroiginal position and depositing in to E/M yard complete all as specified and directed. Including stabilizer.
Taking down / dismaintling / disconnection of Water coolers , refrizerator and Deep freezers of any cap from its oroiginal position and depositing in to E/M yard complete all as specified and directed.
Taking down / dismaintling / disconnection of desert coolers of any cap from its oroiginal position and depositing in to E/M yard complete all as specified and directed.
Supply and install hi wall split units indoor / outdoor complete with cordless remote control unit and with inbuilt Heating and Cooling arrangement and Digital Inverter twin rotary of capacity 1.5 TR 5 star rating complete all as specified and directed.
Supply and install hi wall split units indoor / outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary of capacity 2 TR 5 star rating complete all as specified and directed.
Supply, installation,commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hz of capacity 300/320 LTR 5 star rating complete all as specified and directed.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 ltr complete all as specified and directed.
Supply and fix desert cooler electric driven (single phase), made out of MS sheet not less than 20 gauge body suitable to accommodate exhaust fan turbo force 450mm sweep 1400 RPM with high speed, water tank not less than 120 litre capacity and water pump to meet the requirement as per capacity of desert cooler with all internal pipes heavy duty threaded PVC pipe including honey comb grass pad 03 (three) nos superior quality and front grill made out of non corrosive material with 02 Nos (switch piano type) 6 Amps for fan and water pump and 01 No regulator electronic type suitable for exhaust fan capacity and internal wiring done using 2.5 sqmm copper conductor and 01 No float valve 15mm size with aluminium rod and PVC float and all accessories as required and connect the water supply from existing source and installed the same over existing platform/stand complete all as specified and directed. Make of Exhaust fan & water pump shall be one of the following:- - Havells, Khaitan, Almonard, Crompton.
Supply and fix refrigerator, electric driven (single phase), capacity upto to 195 Litres .BEE 5 star rated complete all as specified and directed.
Supply and fix refrigerator, electric driven (single phase) double door , capacity 310 Litres.BEE 5 star rated complete all as specified and directed.
Taking down / dismaintling / disconnection of Laundry plant , boilers/sluicing machine/drying tumblers and DG Sets of any type and size from its original position and depositing in to E/M yard complete all as specified and directed.
Supply, installation, testing and commissioning of company assembled diesel driven engine, silent DG set of capacity 125 KVA, complying CPCB-IV Norms( CPCB IV+Compliant) with the fallowing specification:-
1. ENGINE:- (a) Engine QSB4.5 Series/QSB4.5 2 Series( CPCB IV+Compliant) ,4 cylinder,In-line 4 strok,radiator cooled . (b) Robust and efficient air handling system with (i) Dry type and replaceable paper element air cleaner with restriction indicator (ii) Optimized turbo charger for increased altitude capabilitied (c) Optimised fule consumption with common rail electronic injection. (d) Spine on single fule filter with water seprater. (e) Cooling system is designed and tested for 50 degree centigrade ambiance condition. (f) Fuel flow spine on lube oil filter. (g) First fill of lube oil and coolant. (h) Electrical starter motor with soft start engaement feature. (j) Battery charging alternater. (k) 2 x 12 V DC battery.
2. ALTERNATOR:- (a) Brushless type, screen protected, revolving field self exited alternator confirming to IS/ IEC 60034-1. (b) Better motor starting capability. (c) Best in class efficiency. (d) Compact design with sealed bearing for longer life and lesser maintenance. (e) Impregnation on all wound components for better mechnical strength. 3. CONTROL PANEL:- (a) PS0602 Controller or eqevalent. (b) Busbar with suitable with incoming and outgoing terminals. (c) Indicating lamps for 'Load ON' and 'Set Running' Instruments fuses duly wired and ferruled. (d) MCCB of suitable rating with short circuit protection. (e) AC / DC sepration inside control panel for safety.
4. SILENCER:- (a) Hospital grade silencer inside canopy with rain capacity suitably optimised to meet stringent noise limit. (b) Silencer specifically tuned to EATS 5. MOUNTING ARRANGEMENT:- (a) Engine and alternator on are mounted on a common MS fabricated base frame with AVM pads. (b) Base frame with integral fuel tank and DEF tank is provided with drain plug, air vent, inlet and outlet connection and provision for cleaning. (c) Skid mounted radiator.
6. ACOUSTIC ENCLOSURE:- (a) Specially designed to meet stringent MoFF / CPCB norms of 75 dBA @ 1 mtr at 75 % load under free field conditions. (b) The acoustic enclosure is made CRCA sheets in Munsell green shade and a structural / sheet metal base frame painted in black. (c) 11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme enviornment. (d) High quality noise absorbment and fire-retardant grade acoustic Insulation material ( Rockwool) complying to IS 8183. (e) Top lifting for easy handling at customer site. (f) External fuel & DEF filling provision. NOTE:- The following testing shall be carried out- (i) As per CPCB IV Norms. Quoted rates shall be deemed to include the testing as mentioned above.
Supply installed and commissioning of Steam Boiler of capacity 600 Kg/Hrs output diesel operated installed at existing position including all connection as safety valve pressure 10.5 Kg/Cm 3 ph 415 V 50 Hz with motor 1.5 KW 2830 RPM complete all as specified and directed by Engr-in Charge. Make:- Thermax, Delta Therm, Alfa entek, Note- Steam boiler shall be tested as per latest IBR Norms and the quoted rates shall be deemed to include the cost of same.
Supply installation and testing and commisoning Commercial Industrial sluicing machine 30 Kg cap double door heavy duty , clean room technology, Soft mount Type, The machine shall be of " Soft Mount, High Spin" type . Features shall include double door for dirty and clean area for the linen. The machine would have doors one for loading and another door for unloading with galvanized frame, heavy duty rear gable and bearing support, four - compartment automatic flush detergent supply box, one frequency controlled motor, prgrammable microprocessor.
(a) There should be single compartment drum for offering he best ergonomics and mechanical action. (b) automatic drum Positioning for fast and effortless loading and unloading operations (c) Automatic outer door locking and unlocking with pneumatic system for maximum safety and efficiency. (d) CONTROL- The machine shall be controlled with an electronic micro- processor with the following minimum features :-
(i) The control shall display remaining wash time , erro codes and program status indication (ii) The display shall by of LCD - type, and shall be possible to display text and symols (iii) Wash Programs: The machine shall have a capacity to store program " libraries " with up to 55 different wash programs. It shall be possible o automatically start a wash program at a certain time, max 99 hours delay. (iv) Validation software for minimization of the costand maximization of the uptime of the equipment and would ensure the following ( running hours, idle time, consumption figure, Machine usage , total consumption, cost alculation etc.) process validation ( print of receipt) - maintenance intervals ( actions are logged) - error alerts ( recommend actions). (e) DETERGENT SUPPLY - The machine shall be available for use with powder or liquid supplies, manual fed or automatic liquid supply via external pumps. No conversion between powder or liquid shall be needed. The manual dispenser shall have four compartments accessible from the front and liquid connections from the rear. (f) OUT OF BALANCE DETECTION - The out of balance shall be determined electronically and based on the out of balance, the machine shall be able to determinethe maximum aloowable speed for extraction upto 350 G. (g) SAFETY FEATURES- Program to ensure that any wash program performs to its end before it allows unloading on the clean side for better control and Hygiene.
(h) DRIVE SYSTEM- The machine shall have a motor powdered by a variable frequency drive. There shall be no gearboxes, clutches or gear reducers. (j) WATER AND DRAIN- The machine shall be provided with two water inlets ( Cold / Hot) . The machine shall be provided with a water operated drain valve without any electricals parts for opeing / closing. (k) ELECTRICAL REQUIREMENTS - The machine shall be avialable in the following voltage configurations: 208-240 V 1 Phase ( STEAM ? NON HEATED) and 400 -415 3 Phase ( ELECTRICAL HEATED) (l) SERVICEABILITY - Major electrical components ( timer, rotary switch, water - valves and oor lock as a minimum ) shall be fitted with multi- position quick - connectn " card-edge" type connectors for quick and easy servicing. (m) DISPENSER- 4 compartment detergent dispensers (n) BASKET VOLUME- 250 Ltrs ( Minimum) (o) OUTER DRUM THICKNESS - Not more than 1 mm (p) INNER DRUM THICKNESS - Not more than 1 mm (q) FINAL EXTRACT- More than 900 RPM or More (r) G- FORCE- 350 G or More. (s) MAXIMUM ELECTRIC LOAD- 20 kw (t) ELECTRIC SUPPLY- 415 V, 3 Phase, AC, 50 HZ (u) ELECTRIC MOTOR- rating should not be more than 5 HP. Make:- Stefab, xpert solution, Supreme shine.
Supply installation and testing and commisoning industrial drying tumblers 60 Kg cap heavy duty, front loading , cool down feature, Auto - timed, Auto-reversible, dual Motor drive, Open Pocket & front display, The dryer should be with temprature control system. For long service life, the drum suspension should have sealed self lubrication bearing with folowing specification :- (a) CONTROL- Microprocessor with adjustable parameters such as temprature, Programme and cool down time. And also the feature to control the moisture control in the dryer. (b) TEMPRATURE CONTROLLER - Auto digital control. (c) TIME CONTROLLER - Auto digital control for drying nd cooling. (d) VALIDATION SOFTWARE- for minimization of the cost and maximization of the uptime of the equipment and would ensure the following ( running hours, idle time, consumption figure, machine usage , total cosumption , cost calculation etc.) - process validation ( print of receipt) - maintenance intervals ( actions are logged)- error alerts ( recommend actions). (e) DOOR OPENING- It should be large for easy loading and unloading.
(f) INNER DRUM- Should be made of Stainless steel AISI-304 The drum should be fitted with 4 lifters. The diameter of the perforation holes should be 8 mm for better perforation and fast drying with 2 loads per hour. (g) RESIDUAL MOISTURE CONTROL- features for the continuous measurement for the garments in the cycle to prevent over drying and thus saving energy and time. (h) SAFETY FEATURES- The tumble dryer should be equipped with overheating protection and a temprature sensor that turns off the heat if the airflow is clogged. (i) INSTALLATION- The tumble dryer should be having design for quick and simple installation by using the adjustable levelling feet. Only one external connection for electricity gas steam and exhaust should be required. (j) DOOR LOCK- The dryer should have a safety function or feature, which means the dryer should stops in case the door is opened during operation. (k) TRANSMISSION- The transmission should have pulley and belt drive. There should be no Gearbox, clutches or gear reducers. The transmission should have a mechinical device for tightening and loosening the drive belt.
(l) DOOR- Made of die pressed Stainless steel AISI 3-4 quality, Toughened glass window, ss door latch /handle and inetrlock for safety. (m) DOOR OPENING - 900 mm dia ( Minimum) (n) BASKET VOLUME- 1200 Ltrs ( Minimum) (o) OUTER DRUM THICKNESS - Not more than 1 mm (p) INNER DRUM THICKNESS - Not more than 1 mm (q) SUCTION BLOWER- Heavyduty Centrifugal Suction Blower and dynamically balanced. (r) LINT SCREEN- Self cleaning lint screen, facility of cleaning should be through front door (s) ELECTRIC LOAD- 3.3 Kw (t) ELECTRIC SUPPLY - 380 - 415 Volt, 3 Phase, AC , 50 Hz. Make:- Stefab, xpert solution, Super shine.
M and L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009.00 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32X6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.
Taking down/dismaintling / disconnection of Transformer , OCB, HT switches from its oroiginal position and depositing in to E/M yard complete all as specified and directed.
Supply and installation of copper wound transformer step up/ step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire LEVEL-3 with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180-2014 of capacity upto 200 KVA complete all as specified.
Supply and installation of copper wound transformer step up / step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with LEVEL-3 off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180-2014 of capacity upto 250 KVA complete all as specified.
Supply and installation of copper wound transformer step up/ step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire LEVEL -3 with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180-2014 of capacity upto 315 KVA complete all as specified.
Supply and installation of copper wound transformer step up/ step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with LEVEL -3 off load tappings on HT side to vary secondary voltage within limit, all as perIS:1180-2014 of capacity upto 150 / 160 KVA complete all as specified. Note for item No 18 to 21:- Comparative test result of losses (Iron and copper) between Level-II and above Transformer (Level III) shall be done and submitted. Cost of testing shall be deemed to be included in the quoted rates.
Supply and installation of HT 11 KV, 3 phase, 50 Hz totally enclosed metal clad switchgear complete with Vacuum circuit breaker having rupturing capacity 250 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 400 / 630Amp complete all as specified with fwg:- FIXED PORTION (a) Floor mounting jig set fabricated steel cubical completed with supports for the gear, earthing connections, final wiring and labels. (b) integral earthing feature built in for bus bar and circuit earthing. (c)Three phase epoxy resin/encapsulated isolating spout assembles complete with isolating contracts and pair of automatic safety shutter which may be individually locked in the closed position for earthing/maintenance purpose.
(d) Three Nos, epoxy cast WPL current transformer with 150/5+5, 30VA burden and CL-1 and CL 5P10 accuracy for meeting & protection respectively. (e) One Nos three phase 3 limb PT 11 KV/100V with 100VA burden per phase class B class 1.0 accuracy for metering & protection respectively. (f) Rear cable box suitable for termination of cables as directed. (g) Multicore cable termination block. (h) Heater with switch and thermostat. (j) Door type instrument panel extension chamber. (k) SCADA compatible relay.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm x 3.5 core, complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 to 185 sqmm complete all as specified and directed.
BRITE INDUSTRIES
SATISH AND CO
LUMOS INFRA PVT LTD
Shree Ayyappa Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .