Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹16.0 L+₹1.6 L (11.4%)Rejected-AOC JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L2 | Rejected-AOC being L2 | |
| 3 | L3₹17.0 L+₹2.6 L (18.3%)Rejected-AOC 121004 | L3 | Rejected-AOC being L3 | |
| 4 | L4₹17.6 L+₹3.3 L (22.9%)Rejected-AOC JANAKI NIVAS BEHIND CHOVVA TEMPLE CHOVVA PO KANNUR KERALA 670006 | KANNUR | KANNUR | KERALA | 670006 | L4 | Rejected-AOC being L4 | |
| 5 | L5₹19.8 L+₹5.5 L (38.1%)Rejected-AOC CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L5 | Rejected-AOC being L5 |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
22 Jul 2022, 6:00 pmClosed
AGE (I) Cannanore
AGE (I) Cannanore HQ Hospital Kannur PO Kannur
Special repairs to repair/replacement of LT Overhead line to LT UG cable network at Wellesly line, Shivaji Coy OTM accn at DSC Centre Kannur under AGE (I) CANNANORE.
2022_MES_530556_1
8193
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Cannanore
Class E category b (i)
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Cannanore
₹32,000
Yes
12 Sept 2022
13 Jun 2022
27 Jul 2022
14 Jun 2022
22 Jul 2022
27 Jun 2022
14 Jun 2022 - 20 Jun 2022
Amount
Excavating in trenches n.exc. 1.5m wide and exc 1.5m and n.exc. 3m in depth for laying of LT UG cable, pipe, pole, stay etc and n exc 10sqm on plan and getting out in hard/dense soil all as specified and directed.
Returning and filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick with soil obtained from excavation all as directed
Removing excavated materials (soil) to a distance n exceeding 50m and depositing where directed at a level 1.5m above starting point all as specified and directed.
Cutting the existing hard standing/ bituminous road surfaces for laying cable / GI pipe etc and providing plain cement concrete (1:2:4) ,type B2,using 40 mm graded stone aggregate for filling road cuttings surfaces and making good the disturbed surfaces all as specified and directed. Note : Excavation required below paving/road shall be measured and paid seperately.
M&L for GI tubing, 40mm bore light grade, galvanized, with all fittings required such as bends, Tees, elbows, sockets, fixing clamps etc for protection of cable/GI strip in road crossing/fixing on ploe, wall etc including removing old unserviceable pipe any size all as directed. Note : Excavation shall be measured and paid seperately.
All as above item No 5 but 80mm bore light grade, GI tubing etc all as directed. Note : Excavation shall be measured and paid seperately.
Supply and spreading in natuaral riddled soil as earth cushioning to cable by using IS sieve to separate the composite particle/roots etc and refilling in trenches and compacted in layers to form a solid bed covering to cable all as specified and directed.
Supply and laying in trenches burnt brick sub class B of locally available size 20x9x6cms for protection of UG cable laid flat and dry over the cable , perpendicular to the direction of cable all as specified and directed.
Supply and lay including fixing and connecting electrically XLPE insulated LT underground cable, armoured heavy duty electric cable with aluminum conductor multi-stranded 1100 volts grade, laid in trench, fixed on wall/pole drawn through pipe etc including provision of lugs & testing of following sizes complete all as specified and directed. (a) 3.5 core 120 sqmm Note for item 9 to 12: Excavation shall be measured and paid seperately. Quoted rate include of making connection to LT panel/feeder pillar box/junction box through suitable size aluminium lugs and cable glands.
All as per item No 9 here in before but 3.5 core 95 sqmm all as specified and directed.
All as per item No 9 here in before but 4 core 25 sqmm all as specified and directed.
All as per item No 9 here in before but 4 core 16 sqmm all as specified and directed.
Dismantling rusted cross arms of any type and any size including insulators, bracing support clamps and back plate by unscrewing bolt and nuts etc from pole all as directed.
Dismantling old unserviceable insulators of any size, type, capacity complete all as directed
Dismantling old unserviceable stay assembly including insulators complete all as directed
Dismantling of defective/perished ACSR conductor over head line from existing pole, service feeder or distribution span all as directed
M & L for PVC weather proof junction boxes of size 250 x200 x100 mm with PVC connector, heavy duty connector 4 way 16 amps and one MCB SP, 6 Amps and making necessary cable connection all as specified and directed.
M&L for electric connection with two runs of single core 1.5 Sq mm copper conductor FRLS cable, PVC insulated, unsheathed multistanded, 1100 V grade drawn through and including non metallic rigid PVC conduit with all accessories such as bend, elbow, socket, tee saddles etc including 1.5 Sq mm single core copper conductor FRLS cable PVC insulated, unsheathed multistranded 1100 V grade as earth continuity conductor connected to common earth dolly fixed on pole with 3Nos suitable clamps, nut, bolts and washers from junction box to street light fittings complete all as specified and directed. Note :- 3 runs of 1.5 Sq mm copper cable and one run of PVC conduit will be measured as one length.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate for concrete as in pole coping including use and waste of form work all as specified and directed.
S&F LED street light fitting 60 watt on LT pole of height 4 to 9 mtr pole new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing, heat resistant with driver, high power LED as lighting source with IP 65/66 protection and impact resistance of IK07. Model HPLLEDSL6060E of HPL or equivalent in CG or Philips complete and electrically connecting up all as directed
S&F brackets for street light fitting made of 40 mm bore GI pipe light grade 1.5m long bend to shape 135 degree inner angle with flat Iron clamps 25 x 3 mm thick, two Nos with nuts,bolts and applying two coats of aluminium painting over one coat of primer complete all as specified and as directed.
Supply, fixing, testing and commissioning of LT feeder pillar panel CPRI approved, obtained from manufacturer of list attached, outdoor cubical type, dust, weather and vermin proof with front openable made out of 3.15 mm thick CRCA sheet with 50 x 50 x 5 mm angle iron frame , bottom floor mounted , compartmentrised double door with neophrene gasket and locking arrangement of suitable size ,mounted on PCC foundation of height 30cm above GL with PCC 1:2:4 type C2, duly powder coated on all side /surface internally and externally with earth terminals on two sides with and inclusive of following items complete all as specified and directed. (a) MCCB 4 pole ,25 KA, 415 V with thermal magnatic release 250 Amps-01 Nos ( for Incoming) (b) MCCB 4 pole ,25 KA, 415 V with thermal magnatic release 100 Amps- 2 Nos ( for In out going) (c) MCCB 4 pole ,25 KA, 415 V with thermal magnatic release 63 Amps- 5 Nos ( for In out going) (d) MCB TPN 40 Amps, 415 Volts - 2 Nos (e) MCB SPN 32 Amps, 415 Volts - 2 Nos (f) Bus bar set of aluminium 400 Amps for R Y B and 200 Amps for neutral - 01 Set (g) Multifunction electronic meter 3 phase 415V suitable to indicate volts, current, power factor, frequency and KWH - 01Nos (h) Internal wiring of panel board with suitable size FRLS grade copper cable of 1100 Volt with connection through copper lugs /thimbles at ends - 01 Job (j ) Indicating lamps for R Y B - 01 Set (k) Timer switch with relay 32 Amps - 01 set Note:- Ratequoted shall include Electrical connection of cable at both ends through cable glands/ al lugs
Supply, fixing, testing and commissioning of LT feeder pillar panel CPRI approved, obtained from manufacturer of list attached, outdoor cubical type, dust, weather and vermin proof with front openable made out of 3.15 mm thick CRCA sheet with 50 x 50 x 5 mm angle iron frame , bottom floor mounted , compartmentrised double door with neophrene gasket and locking arrangement of suitable size ,mounted on PCC foundation of height 30cm above GL with PCC 1:2:4 type C2, duly powder coated on all side /surface internally and externally with earth terminals on two sides with and inclusive of following items complete all as specified and directed. (a) MCCB 4 pole ,35 KA, 415 V with thermal magnatic release 250 Amps-01 Nos ( for Incoming) (b) MCCB 4 pole ,25 KA, 415 V with thermal magnatic release 63 Amps- 5 Nos ( for In out going) (c) MCB TPN 40 Amps, 415 Volts - 2 Nos (d) MCB SPN 32 Amps, 415 Volts - 1 Nos (e) Bus bar set of aluminium 400 Amps for R Y B and 200 Amps for neutral - 01 Set (f) Multifunction electronic meter 3 phase 415V suitable to indicate volts, current, power factor, frequency and KWH - 01Nos (g) Internal wiring of panel board with suitable size FRLS grade copper cable of 1100 Volt with connection through copper lugs /thimbles at ends - 01 Job (h ) Indicating lamps for R Y B - 01 Set Note:- Ratequoted shall include Electrical connection of cable at both ends through cable glands/ al lugs
Supply, fixing, testing and commissioning of factory fabricated prewired bus bar, CPRI approved, cubical type, IP 65 of suitable size out door, double door dust, weather and vermin proof with front and back openable made out of 3.15 mm thick CRCA sheet with 50 x 50 x 5 mm angle iron frame , bottom floor mounted , compartmentrised double door with neophrene gasket and locking arrangement of suitable size ,mounted on PCC foundation of height 60cm above GL with PCC 1:2:4 type C2, duly powder coated on all side /surface internally and externally with earth terminals on two sides with and inclusive of following items complete all as specified and directed. (a) MCCB 4 pole ,35 KA, 415 V with thermal magnatic release 250 Amps-01 Nos ( for Incoming) (b) MCCB 4 pole ,25 KA, 415 V with thermal magnatic release 63 Amps- 2 Nos ( for In out going) (c)Apron shall be provided at bottom for protection of cable - 1 Nos (d) Bus bar set of aluminium 400 Amps for R Y B and 200 Amps for neutral - 01 Set (e) Multifunction electronic meter 3 phase 415V suitable to indicate volts, current, power factor, frequency and KWH - 01Nos (f) Internal wiring of panel board with suitable size FRLS grade copper cable of 1100 Volt with connection through copper lugs /thimbles at ends - 01 Job Note for item No 23 to 24 :- Ratequoted shall include Electrical connection of cable at both ends through cable glands/ al lugs
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 32x6 mm thick by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I Note :- Rate quoted shall deem to include for GI earth wire and GI pipe lead upto 7.5m length.
JEETH CONSTRUCTION
Neptune Engineers and Builders
T.P.SUNIL KUMAR
M/s.Rejoy Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .