Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹3.0 L
Closing Date
26 Jun 2026, 2:00 pm
Executive Engineer Mechanical Div Kargil
office of Executive Engineer Mechanical Div Kargil
Design, Supply, Installation, Testing and Commissioning of Hybrid Run (Grid - Solar) single stage/ Multi stage Split case/Centrifugal Pump coupled with squirrel cage Induction motor with Hybrid motor starter, SPV Panels and Rising main and its allied
2026_PWD_19033_2
MDK/E-NIT/04/2026-27
Open Tender
Pumps/Motors
365 days
LIS Shimsha Drass (Ashgrmm Nalaah)
Please refer Tender documents.
10 documents required · 10 mandatory
₹3,000
Executive Engineer
₹3.0 L
office of Executive Engineer Mechanical Div Kargil
13 Jun 2026
13 Jun 2026
27 Jun 2026
13 Jun 2026
26 Jun 2026
13 Jun 2026
19 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Multistage Horizontal Centrifugal Pump / Split Casing with SS Impeller, Cast Iron/S.G Iron casing/WCB, mechanical Seal, bearing lubrication oil, Coupled to energy efficient squirrel cage induction Motor resting on a M.S common base frame properly aligned. The motor shall be suitable for three phase 415 V ± 10%, 50 Hz supply. Pumps shall be installed in parallel combination (1 running + 1 standby) fitted with all Long radius bends, common pressure header with Flanges, Cork sheet Gaskets, Nuts Bolts with washers, provision for 25mm priming facility using 25mm heavy duty ball valves 02 Nos, 25 mm (ERW) M.S. Pipe etc with each pump and M.S suction pipe of 200mm dia, 8m length, with flanges, long radius bends foot valves with strainer, clips and clamps, nipples, flanges as per site requirement. The job also includes shifting of pumps set from NH to pump house by means of head load etc. the details are as i) Capacity of Pump = 1.00 Cusec (102.0m3/h) ii)Total Dynamic Head = 200 mtrs iii) Efficiency at duty point : >70% iv) Driving Motor Rating to be calculated (……. KW/……. HP) at 415V ± 10%,50Hz ,Speed =1450 RPM – 1480 RPM Selected motor rating shall be higher than following 125% of pump input at duty point Maximum power consumed by the pump in the entire operating range. Operating range may be considered from 110% to 85% of rated head. Insulation = F-class Vi) NPSHa= 3 meter All necessary service manuals/parts catalogs should be made available along with machine /equipment. | |||||
| 2Control valves of Pump Delivery Size 1. Nozzle Type Check Valve, 125 mm, PN 20= 02 No., PN 16=2 no’s 2. Sluice Valve, 125mm, PN 20 = 02 No. 3. Foot Valve 125mm , PN 20= 02 Nos. 4. . Air valve with triple-function isolation valve 60mm = 03 Nos. | |||||
| 3Design supply testing and commissioning of Hybrid (Grid+Solar) control panel with 200Hp soft Starter Control panel with one Incomer and two out goings for two pump sets in parallel Operation. (One running and the other standby and vice versa (both on Grid + Solar) 200 HP Soft-Starter for each pump set. fixed type, floor mounted, cubical design motor control panel fabricated out of 2mm/14 SWG CRCA thick sheet duly painted, suitable for indoor use, internally wired complete with bus bar covered with PVC heat shrinkable sleeves, colour coded. Panel shall be fitted with 02 Nos. Soft Starter motor starters suitable for 3-phase, 415 Volts, 50 Hz Squirrel Cage Induction Motors, with all components of suitable rating fixed and wired in the panel. The panel shall be complete with all protections in-built (Over load/PTC/Line fault / Voltage imbalance / Phase reversal / Under voltage / Over voltage / Over temperature / Open Gate / Excessive Starts per Hr, Single phasing), Main incoming MDO ACB 300A with short circuit release including earth fault and under voltage protection. Bus bar, metering ( incoming and outgoing Voltmeter, Ampere meter, Frequency meter) (3-phase current/3-phase voltage/power factor of running motor, phase indication lamp (RYB with CTs), Outgoing ….. A ACB with 250 HP Soft starter for each pump sets, capacitor Bank 250KVAR for an improved power factor of .95 to 1, over load relays. The control panel shall be complete with single core copper cable of size 240 mm2 of 200 RMT confirming to IS 694 with required thimbles from LT transformer to Panel and 3 ½ core Al Cable of 40 RMT of current rating more than …… Ampere. Parts Catalog-01No The Soft starter component shall be at the bottom part of the panel so that the motor connection cable length is minimized. | |||||
| 4Design, Supply, Installation, Testing and Commissioning of shockproof photovoltaic solar panels,providing of cables from solar house to Pump house, also including all civil works, base structure, junction box, and associated components complete in all respect: Specifications: 01) Number of photovoltaic panels: as per OEM’s description, ensuring total output exceeds motor rating by 30%. 02) Operating temperature for solar cell : 200c to 45Oc 03) Temperature coefficient : - 0.2867 to – 0.4 04) Max power at STC: 79% to 82% 05) Module Efficiency: 20% or higher PV Module specifications: 01. Type: Monocrystalline silicon solar cells 02. Peak power of a single model (Wp): 540w or above 03. Open circuit voltage :44-46V 04. Current at Max power: 13-15A 05. Current at Max power: 13-15 A 06. Series Fuse Rating: 10A or as required 07. Application class Ratings: class A 08. Fire ratings: Class C 09. Compliance: PV modules shall meet meet the IEC 61215 revised specifications and be certified by MNRE/ISI/ISO/IEEE/IEC or equivalent. Parts catalog complete 01No | |||||
| 5Maintenance free earthling:-S.I.T.C. of ALLTEC make long life maintenance free electrolytic earthling system for Panel, AVR, Motor and X-mar with 10 feet vertical k type copper not less then 2”(50.8mm)ID and not less than 0.08”(2.03mm) wall thickness, which does not require manual addition of water. The system should be corrosion resistant pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. Rated for high fault currents bas bar rated for 10KA, fault current bus bar connection type as “Terraweld” to with hold temperature of 700˚C. The earthling port shall be designed and supplied with poly plastic port cover non conductive, environment friendly and lockable. | |||||
| 6Providing, laying, jointing and testing in trenches of galvanized MSERW flanged pipes including cost of flanged bends of all degrees conforming to IS/ISO:3183-2007, as per dimensions, weight and test pressure mentioned below in a random length of 4m-7m,The M.S. flanges are to be provided 100% of flanged joints and welding of flanges with pipes as per IS:816-1965 with a electrode as per IS:814-1967 including required Nos. and size of M.S. nut and bolts as per IS: 1369-1967 and compressed as best fiber jointing gaskets sheet not less than 3mm thick as per IS:2712-1965.The welding of flanges to be done on both faces in two layers to make the joints leak proof and to the entire satisfaction of the Engineer-in-charge. The laying of pipes should be conformed to IS:5822-1994 (earth work in trenches, MS flanges and butt welded joint to measured and paid separately) The pipe shall have zinc coating as per IS 4736 in factory latest with upto date ammendements. Note: - Ground clearance of the rising main (Header) must be above 1 feet(or better) at any point while crossing the terraces/field Make:- Jindal (india) limitted | |||||
| 6.1 | 125mm dia MSERWpipe Gr. L290 0r X-42, 4.8mm wall thickness IS/ISO : 3183-2007 | - | Mtr | - | - |
| 7Complete Pump Tool Kit DE Spanner double ended set of size 06-42mm =01Set Ring Spanner set of size 06-42mm =01 set Screw driver=01Set Pliers-02Nos. Heavy duty Socket set=01Set l-key =01 set make- conforming to IS/ISI standard Grease gun (5Kg) Bucket type=01No Providing of 1 Ton chain pully for suction lifting-01No Heavy duty Pipe wrench (Size 4” L-735mm)-02Nos Heavy duty chain wrench- 02 Nos Heavy duty chain wrench (36”)- 02 Nos Hand gloves-02Set and additional Gland packing(12mm)-05Mt | |||||
| 8Construction of Anchor Block Construction of PCC Anchor block of size 2’ x 2’ x 4’ using (1:2:4)mix @20 feet c/c. Job includes cost of material, labour, shuttering, tools and tackles etc. The job also includes fixing of 02 Nos. 6mm MS strip with suitable anchor bolts to fasten the Pipe on the anchor block. The size of the block is shall be as per profile of raising main and instruction of site engineer Block size = 2’8”x2’8”x4’ = 0.808 Cum For 80 blocks = 0.808x80 = 64.64cum | |||||
| 9Construction of RCC Anchor block (As per Drawing A) using (1:2:4) mix @ 150 mtr-c/c. Job includes cost of materials, including straightening, bending, cutting and placing position, binding all reinforcement, earth excavation, centering shuttering and removal of farm work, carriage charges complete. Total Quantity = 06 blocks | |||||