Tender Value
₹6.8 L
EMD Value
₹6,800
Closing Date
10 Jun 2026, 6:00 pm5d left
Deputy Executive Engineer, Electrical (R&B) Sub Division, Jamnagar
Providing New DG set for backup power supply in taluka sevasadan bhanvad, Dist. Devbhoomi Dwarka (2nd try )
310028
06(B) of 2026-27
Open
Electrical Works
Jamnagar
8 documents required · 7 mandatory · 1 optional
₹900
Deputy Executive Engineer, Electrical (R&B) Sub Division, Jamnagar
₹6,800
1 Jun 2026
1 Jun 2026
1 Jun 2026
10 Jun 2026
1 Jun 2026
Name Of Work :- Providing New DG set for backup power supply in taluka sevasadan
bhanvad, Dist. Devbhoomi Dwarka (2nd try )
Qty. Unit Description of Item Net Rate Rate in Word Per Amount
1 150.00 Mtrs Providing and erecting ISI mark Medium class RIGID PVC PIPES of 33.33 Rupees Thirty Mtr
. following size complete to be erected on/in wall or ceiling erected Three and .
with necessary PVC fittings & Junction boxes fixed with adhesive Thirty Three
solution & Clamps with following dia of pipes, in approved manner as
directed (b) 25 mm
2 150.00 Mtrs providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI 240.38 Rupees Two Mtr
. marked stranded Copper conductor wire in following type of pipe to Hundred Forty .
be erected in / on wall / ceiling with 2.5 sq. mm copper conductor and Thirty
FRLS PVC insulated stranded wire of green colour for earth continuity
of following size (E) in existing pipe (h) 4 wire 6 sq. mm
3 2.00 Nos. Providing and erecting Approved make Four pole moulded case circuit 6790.23 Rupees Six Ea.
breaker having breaking capacity ICU of 25 KA. at 415 V,having normal Thousand
current rating up to 25 A to 100A. with Fixed thermal & magnetic Seven Hundred
release suitable to work on A.C. supply 50 c/s. with all internal Ninety and
connections, spreader tinned copper & complete erected in existing
16 G.M.S. housing.ICS=100% of ICU only Cat III
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No
3-4-1 to 3-4-12 (The Enclosures should be used of same company of
MCCBs to be used)
4 1.00 Nos. Supplying & erecting approved make Four Pole 415V change over 4785.38 Rupees Four Ea.
switch interior for panel mounting with operating mechanism A.C.23 Thousand
duty confirming to IS for (B)63 A Cat-III Seven Hundred
Eighty Five and
5 12.00 Nos. Providing & erecting 240 V MCB double pole switch for lighting Load 295.93 Rupees Two Ea.
(B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in Hundred
existing box having following capacity (B) 40 Amp. Cat-III Ninety Five and
6 4.00 Nos. Providing & erecting 415 V MCB Four Pole for Motor & Inductive 737.30 Rupees Seven Ea.
Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in Hundred Thirty
existing box having following capacity (c)63 Amp. Cat-III Seven and
7 2.00 Nos. Providing and erecting Sheet Steel powder coated MCB distribution 629.23 Rupees Six Ea.
board - flush / surface mounted fitted with busbar, neutral link, earth Hundred
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without Twenty Nine
MCB to house appropriate nos. of MCBs.(The DBs should be used of
same company of MCB to be used) suitable for (A) single phase
incoming and horizontal single phase outgoing(b) sheet steel double
door (IP-43) (i)4 way
8 2.00 Nos. Providing and erecting Sheet Steel powder coated MCB distribution 2339.16 Rupees Two Ea.
board - flush / surface mounted fitted with busbar, neutral link, earth Thousand
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without Three Hundred
MCB to house appropriate nos. of MCBs.(The DBs should be used of
Thirty Nine and
same company of MCB to be used) suitable for(B) three phase
incoming and single phase horizontal type outgoing Per phase
isolation type (PPI) (b) sheet steel double door (i)4 way
9 6.00 Nos. providing and erecting Approved make RCCBs conforming to IS: 12640 2235.13 Rupees Two Ea.
and having sensitivity of 30 mA and Short Circuit withstand capacity of Thousand Two
10 KA and suitable for operation on single phase 240 V,50Hz. having Hundred Thirty
characteristic of quick action & tripping with all advance feature & do Five and
not incorporate any electronic component. for following Max. rating
Thirteen Paisas
erected as directed (ii) 40Amps. DP Cat-III
10 6.00 Kgs Providing and erecting required size Copper strip for earthing of H.T. 794.87 Rupees Seven Kg.
OCB / ACB/ Transformer, LT panel board, Motors etc. using copper Hundred
clamp. Ninety Four
11 3.00 Nos. Supplying & erecting in earthpit of minimum bore dia. 225mm size 7095.25 Rupees Seven Ea.
approved make Safe Earthing Electrode consisting Pipe-in-Pipe Thousand
Technology as per IS 3043-1987 made of corrosion free hot dipped Ninety Five and
G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron Twenty Five
galvanising, Inner pipe dia of 40 mm having 200-250 Micron
galvanising, connection terminal dia of 14 mm with constant ohmic
value surrounded by highly conductive compound with high charge
dissipation suitable for following type of applications with chamber
and heavy duty cover (A)(approved make OEM has to submit test
certificate including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has to ensure the
value of earthing resistane mentioned in test Certificate) & having
back filling compound of (B) Inner chemical (CCM Compound)-
Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage
drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back
fill Compound :- Earthing compound should be capable to retain
moisture for long time Necessary test report must be submitted by
Agency. [B] For Electrical installation up to 11 KV located in other
than normal soil
0 0.00 0 i.e. Soft Rock, Marshy Soil etc. -Length of Pipe : 2 mtr -Back filling 0.00 0 0
Compound :1 no. Bag of 25 Kg.
12 30.00 Mtrs Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 396.93 Rupees Three Mtr
. 1.1 KV grade to be erected as directed of following size.(E) 12 core 2.5 Hundred .
sq.mm Ninety Six and
13 140.00 Mtrs Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 284.82 Rupees Two Mtr
. multistrand Aluminium conductor for 1.1 KV. to be laid on wall with Hundred .
necessary clamps or in existing trench / pipe of following size of Eighty Four
cables (C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
14 12.00 Mtrs Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 3576.41 Rupees Three Mtr
. multistrand Copper conductor for 1.1 KV. to be laid on wall with Thousand Five .
necessary clamps or in existing trench / pipe at road crossing or floor Hundred
of following size of cables.(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2
15 20.00 Mtrs Making trench in Hard Murrum / Tar Road of suitable width of 90 cm 357.54 Rupees Three Mtr
. or required depth for laying any size of cable or locating the fault all Hundred Fifty .
over the run and back filling the same and making the surface as Seven and Fifty
normal ground. (B) If additional machinery like hammer driller or JCB
16 30.00 Mtrs Providing & laying approved make Double walled corrugated pipes 62.62 Rupees Sixty Mtr
. (DWC) of polyethylene(conforming to IS 14930 II )with necessary Two and Sixty .
connecting accessories of same material at required depth in existing Two Paisas Only
trench for laying of cable. below ground / road surface for enclosing
cable (A)50 mm outer dia
17 9.00 Nos. Providing and, fixing heavy duty flange type brass double compression 75.75 Rupees Ea.
type cable gland with rubber ring for PVC insulated armoured cable Seventy Five
complete with out going tails, insulating tape etc for following size of and Seventy
cables. (B) 3 & 1/2 core 35/50 Sq. mm
Five Paisas Only
18 9.00 Nos. Solder less crimping type Aluminium lugs conforming to IS suitable for 15.15 Rupees Fifteen Ea.
cable of following size evenly crimped with high pressure tool & and Fifteen
connected to switchgear terminals with brass/cadmium plated nut Paisas Only
bolts in an approved manner. (C) 16/25 Sq.mm.
19 27.00 Nos. Solder less crimping type Aluminium lugs conforming to IS suitable for 20.20 Rupees Ea.
cable of following size evenly crimped with high pressure tool & Twenty and
connected to switchgear terminals with brass/cadmium plated nut Twenty Paisas
bolts in an approved manner. (D) 35/50 Sq.mm.
20 2.00 Nos. Solder less crimping type Copper lugs conforming to IS suitable for 12.12 Rupees Ea.
cable of following size evenly crimped with high pressure tool & Twelve and
connected to switchgear terminals with brass/cadmium plated nut Twelve Paisas
bolts in an approved manner. (C) 16 Sq.mm. Only
21 6.00 Nos. Solder less crimping type Copper lugs conforming to IS suitable for 22.22 Rupees Ea.
cable of following size evenly crimped with high pressure tool & Twenty Two
connected to switchgear terminals with brass/cadmium plated nut and Twenty
bolts in an approved manner.(E) 35/50 Sq.mm.
Two Paisas Only
22 3.00 Sq.M Supplying and erecting HYLAM sheet on existing angle iron frame.for 2311.89 Rupees Two Sq.
trs. following thickness (F) 12mm Thousand Mtr
Three Hundred .
23 1.00 Nos. Supplying and erecting, commissioning and testing of Diesel 412383.00 Rupees Four Ea.
Generating set confirming to IS: 4722:1968 & BS:5514 having Lacs Twelve
continuous rating, 3 phase, 415 volts, 50 cycles A.C. supply comprising Thousand
of a totally enclosed air/water cooled diesel engine with multi-
cylinders developing suitable BHP not less than following capacity at
1500 RPM with 10% overload for one hour in 24 hours with standard
accessories like fly wheel, lubricating oil cooler, "A" class governor,
heavy duty fuel wheel and lubricating oil filter, oil bath air filler,
lubricating oil pressure gauge, end exhaust manifold, standard set of
tools with adjustable spanners, screw drivers, cylinder head to cover,
joint cylinder head to exhaust, element lube oil filter, 12 / 24 volts
electric starting equipment complete with standard heavy duty
battery, dynamo, cut-outs, ammeter, necessary wiring, pressure
gauge, starter etc and heavy duty Residential type exhaust silencer
(With DEF System) and vertical hot air duct both logged with asbestos
rope, save oil trays, exhaust piping of required length, standard
wall/floor mounted fuel with level indicator and piping and drip proof
alternator, self excited, self regulated, screen protected, with
excitation system,
0 0.00 0 capable of delivering the rated system output at 415 volts, 3 phase, 0.00 0 0
0.8 PF, 50 Hz, 4 wire, running at 1500 RPM, conforming to IS-4722-
1968 with voltage regulation +/- 5% of rated voltage from no load
to full load. Both the engine and alternator fitted on a common
fabricated steel base plate with antivibration mounting engine and
alternator both connected to each other by flexible flange coupling
and with floor/wall mounted control panel box comprising of
voltmeter ammeter, selector switches, ACB / MCCB / MCB of
adequate capacity, indicator lamps duly wired with HRC fuses. The
alternator & control panel shall be connected with provided suitable
capacity armoured cable and complete with Acoustic enclosure
(canopy) made out of 16 SWG CRCA Sheet, sound absorbing material
Rockwool of 64 density & 100 mm thick conforming to IS:8183 / PU
Foam of 40 Density - at least 40 mm. The resin bonded rockwool
covered from inside the canopy by perforated sheet with 3/4 mm
holes, sound level not more than 75 dB at a distance of 1 mtr, as per
PVCT norms.DG set should have in built fuel tank capacity of
minimum 8 hrs of continous running capacity on full load .
0 0.00 0 Erection, commissioning and satisfactory testing as per requirement 0.00 0 0
with first filling of fuel (minimum up to the 80% of fuel tank capacity),
oil, etc. with guarantee / Warrantee of complete system for Two
years. & with obtaining all necessary certificate from Electrical
Inspector. The Capacity and Ratings of DG sets are as below. (As per
new CPCB4+ Emission norms Engine With - Turbo Charger, EGR
(Exhaust Gas Recirculation), CRS (Common Rail Fuel System), DOC
(Diesel Oxidation Catalyst), SCR (Selective Catalytic Reduction),
Integrated wiring harness connected to ECU .) (D) Continuous Rating
of 25 KVA ,BHP not less than 32 BHP
24 1.00 Nos. Providing & erecting approved make ATS panel suitable for following 40229.31 Rupees Forty Ea.
size of 3 phase, 415 V., 50 cycles, A.C. diesel generating set complete Thousand Two
of scope as detailed below: 1) Power module: Motorised Changeover Hundred
switch with ATS controller, Auxiliary contactor with NO & NC contacts
with Automatic Battery Charger, indicating lamps for Generator ON,
Mains ON, Load and suitable control terminals and power terminals
with neutral earthing studs. (A) ATS Panel for 15/20 / 25 KVA 3 phase
Net Amount Put toTender Rs.
Note : This Estimate has been prepared as per new SOR which is exclusive of GST hence additional GST will be paid to the agency
as per existing guidlines.
Deputy Executive Engineer Executive Engineer
Electrical (R&B) Sub Division Electrical (R&B) Division
Jamnagar Rajkot
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ANNEXURE-II notice NIVIDA 6B 2026-27.pdf
sch B.pdf
SBD Nivida 6B of 2026-27.docx
DOCX
Contractor_Registration_Paripatra__1_.pdf
EMD_SD GR.pdf
GR for single Tender.pdf
Download all tender documents and submit your bid