Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC B302 SHALIGRAM LAKEVIEW SP RING ROAD KHORAJ AHMEDABAD GUJARAT 382421 | GANDHINAGAR | GUJARAT | 382421 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹21.3 L+₹1.9 L (9.65%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹26.4 L+₹7.1 L (36.4%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹30.7 L+₹11.3 L (58.3%)Rejected-Finance 102 AMARAPALI COMPLEX 102 AMARAPALI COMPLEX BEHIND YASH COMPLEX GOTRI GERI ROAD BEHIND YASH COMPLEX GOTRI GERI ROAD | L4 | Rejected-Finance Rejected | |
| 5 | Rejected-Technical | - | Rejected-Technical Disqualified |
Tender Value
Refer Docs
Closing Date
20 Feb 2021, 6:00 pmClosed
AGM-Electrical
INDIAN INSTITUTE OF MANAGEMENT AHMEDABAD
Extension of existing 11 KV Electrical Substation at New Campus-IIMA.
2021_IIMA_614212_1
IIMA/CONTRACTS/TW-065/2020-21
Open Tender
Electrical Works
Works
120 days
INDIAN INSTITUTE OF MANAGEMENT AHMEDABAD
As per NIT Chapter-1
5 documents required · 5 mandatory
₹0
Exempted
INDIAN INSTITUTE OF MANAGEMENT AHMEDABAD
3 Mar 2022
4 Feb 2021
22 Feb 2021
4 Feb 2021
20 Feb 2021
15 Feb 2021
4 Feb 2021 - 9 Feb 2021
10 Feb 2021
Amount
SECTION - 1.0 SUBSTATION EQUIPMENT AND AUXILLARY
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF INDOOR H.T.PANEL - Supply & Labour charges for installation, testing and commissioning of 11 KV panel indoor drawout type VCB cubical switchboards with complete internal wiring. The rate shall include the following activities. SCOPE - SUPPLY AS PER ATTACH SPECIFICATION + GST + TRANSPORTATION + INSURANCE & AS PER SPEICIFICIATION. (i) Shifting of panel to the room from site stores/out side if required. (ii) Opening of packing. (iii) Installation of 11 KV SF6 VCB cubical switchboard on the foundation, supply & grouting of the foundation bolts including supply of foundation bolts, nuts, washers, making pockets in the floor etc. at the location shown at site/in the drawing. (iv) Assembling of all the panels, connections of busbars, wiring etc. as per manufactures drawing.
SUPPLY & INSTALLATION of Indoor Draw Out type BREAKER - 2 Nos. 800A 11 KV HT VCB panel with Seperate enclosure by Connection of existing busbar to New busbar, Checking of control wiring, Setting of relay, Testing with co-ordination with Existing H.T.Panel vendor before commissioning (Two Outgoing Panel) Near Existing HT VCB Panel (Incomer Provision of coupling of Main Busbar from Existing HT panel to be provided. Also scope of coupling the existing panel to be considered.) ( Incomer from Existing Busbar + 2 nos. Out going VCB panels )
SUPPLY & Installation of Indoor Micro-Processor Relays of P-111 or Equivalent for Existing HT Panel incoming & outgoing feeders, Checking of control wiring, Setting of relay, Testing with co-ordination with H.T.Panel vendor before commissioning. Scope of work includes Dismentling of existing relays.
SUPPLY & Installation of 11KV Bus Bar of suitable size from Existing Bus Bar with enclosure to New Panel, Testing with co-ordination with H.T.Panel vendor before commissioning
SUPPLY & Installation of Incomer CT 250/5A 2CORE accuracy class 0.5 & 5P10 15 VA. Cost including removing of OLD CT / wiring etc.
SUPPLY & Installation of WTI alarm & trip electro-mechanical relay with wiring in all transformer feeder etc.
SUPPLY & INSTALLATION OF 11 HT (E) END TERMINATION
Supply, Termination , testing and commissioning of 11KV (E)H.T. end heat shrink type joints - indoor type with Raychem/ 3 M make kits for 3C x 300 sqmm AL XLPE SCOPE Includes -magger testing of cable / supply of termination kit with AL lug . Nut blots -washer / tools & teckals require for jointing.
Supply, Termination , testing and commissioning of 11KV (E)H.T. end heat shrink type joints - indoor type with Raychem/ 3 M make kits for 3C x 240 sqmm AL XLPE SCOPE Includes -magger testing of cable / supply of termination kit with AL lug . Nut blots -washer / tools & teckals require for jointing.
SUPPLY & INSTALLATION OF SAFTY EQUIPMENT
Supply & Fixing of ISI marked 6 kg Co2 type portable fire extinguisher with necessary clamps, supports and trolley in Panel room.
Supply and fixing of first aid box.
Supply & Fixing of 4 nos of fire buckets with floor / wall mounting stand and first filling of sand.
Supply and fixing of 11KV / 1.1 KV grade 2mm(As Per IS-15653 2006) thick 1000 mm wide polymer silicon insulating mat
Hand gloves (11 KV grade)
Shock treatment chart with wooden frame and glass cover. (LOCAL & ENGLISH)
Insulated Rod for D.O FUSE opearation 11 kV two pole structure
Non-flammable coating applied by spray or brush to prevent flame spread in cable trays and grouped cable installations.- apply spray (APPROVED MAKE - HILTY/ SUPER MAX)
Modular type fire extinguisher ( Clean Agent material) with Sprinkar valve- 15 KG - which opearate at 68/ 79 Dec temp with necessary fixing clamps,- for UPS room / BMS ROOM/ Electrical panel room (APPROVED MAKE - HILTY/ SUPER MAX)
SECTION - 2.00 SUPPLY & LAYING OF H.T./L.T. XLPE CU/AL ARM. CABLES & CONTROL CABLES
Supply, Laying, Testing and Commissioning of cables on cable trays, structural supports and cable supports provided, include unloading, shifting upto site. The scope includes clamping of cables by ready made G.I. spacers, saddles or clamps fabricated out of M.S. strip 3 mm thick, Treasing and Clamping of Cable on cable tray, supply of all clamping materials and hardware etc., providing cable tags made out of aluminium strip and 75x20 mm in size with cable number and size punched on it. Cable tags shall be tied to cables at every 20 meter interval and at both the ends. Supports provided for clamping of cables upto individual motors and push-buttons shall be paid extra as per item rate for MS fabrication work. Empty cable drums shall be returned to stores. In case of laying unlisted cables, rate of cable whose outer dia is closest to the cable sizes quoted shall be applicable. The same shall hold good for cable termination also.
3C X 300 SQMM 11 KV (E) H.T.CABLE
SECTION -3.00 EARTHING
Supply & making of maintenance free Earthing station with the use of 19/21mm dia copper Rod ,3M long- ,with 50kg- grounding material (back fill compound with moisture capture capacity and reuse soil) resistivity - scope includes supply of electrod/ back fill compund / labour charges fo bore of 300- 3.5 mtrs depth/making earth chember with 450 mm x 450 mm x CI / FRP cover Installation detail - making 3.5 m depth bore - 100 mm fill with chemical compund paste / put electrode in centre of bore / fill up balance space of bore with chemical compund / balck cotton soil ( if avilable ) paste - carefull for no air gap in paste , ALSO CHECK WITH ELECTRODE / COMPUND MANUFACTURE FOR INSTALLATION DETAIL TO ACHIVE LESS THEN 1 OHM
Supply & making of maintenance free Earthing station with the use of 50mm dia Hot Dip Glavnized pipe in strip type ,3M long- ,with 50kg- grounding material (back fill compound with moisture capture capacity and reuse soil) resistivity - scope includes supply of electrod/ back fill compund / labour charges fo bore of 300mm- 3.5 mtrs depth/making earth chember with 450 mm x 450 mm x CI / FRP cover Installation detail - making 3.5 m depth bore - 100 mm fill with chemical compund paste / put electrode in centre of bore / fill up balance space of bore with chemical compund / balck cotton soil ( if avilable ) paste - carefull for no air gap in paste , ALSO CHECK WITH ELECTRODE / COMPUND MANUFACTURE FOR INSTALLATION DETAIL TO ACHIVE LESS THEN 1 OHM
SUPPLY & FIXING OF EARTHING GRID BY COPPER (99.9 % PURE) / HOT DEEP GLAVNIZED (80-100 Micron) STRIP Providing, fixing,connecting and testing earth grid by using copper/G.I. earth strips for earthing of sub station equipments. The job includes supply of necessary materials such as a copper/G.I. strips, spacers, brass bolts and nuts, washers and other hardware as required to complete the grid. At the joint of two strips a section of 100 mm suitable thickness copper /G.I. strip to be fixed, with brass nuts bolts. i) The job also include fixing & laying of class `B' G.I. pipe when strip is entering in the building structures etc. ii) Job Done as per drawing shown in execution drawing. iii) Earth strip to be fix Nr. Earth pit with 2 nos of Nut & bolt washer & spring washer iv) all other place strip to be weld - 100 % over laping of strip base on size of earth strip & welding all side of strip & apply black bitmnus paint & cotton tap on welding part v) in cable tray near colum earth bus 150 mm long same of earth strip size to be weld with 3 nos of 10 mm hole for future earth connection (as per given in execution drawing) vi) for copper strip brezzing to be done for connection of extantion of earth strip
32 x 6 mm Cu. Strip
25 x 6 mm GI. Strip
50 x 6 mm GI. Strip
Equipotential Earth Bars -scope supply & installtion of anchor fashner +insulation +earth bus as per below mention size
Equipotential bars - 300 x 50 x 10 mm GI.
Heat Shrink for 32 x 6 strip for insulation
SECTION -4.0 MISCELLANEOUS WORKS
LAISIONING CHARGES : Processing of form on behalf of client, getting sanction of power.The rate shall be inclusive of Obtaining Electrical Inspectorate approval for the installation including preparation of drawings,spot inspection etc.All official payments against receipts will be paid by client. --------------------------------------------------------------------------------------------------------------------------- Preparation and submission of asbuilt drawings, CEIG approved drawings, panel GA drawing in suitable (1:100) size hard copy & compact disc-soft copy and documentation for all equipment/switchgears etc. used in the project in triplicate. Laminated SLD to be displayed in the electrical room.
Supply and erecting fabricated support works / stands etc complete fabricated as per details given from MS flat / angle / plates etc complete with 2 coats of red oxide and 2 coats of paint on the same along with mounting of supports with use of necessary hardwares complete. Support for panel frame / juction box / MCBDB framing(Other than the supports for Cable trays)
SITC of IP 65 category Thermo Plastic Material junction boxes with necessary loop in loop out connectors / busbars / internal wiring if required etc. complete. The boxes if required shall be mounted on 9" MS supports which shall be considered in cost.rate cibnsidering termianl require up 35 sqmm cable - ampproved make - HENSAL / SECHME / SPELSBERG- SIZE TO BE CHECK WITH VENDOR - NEAR SIZE TO BE CONSIDERING & MENTION IN OFFER
SUPPLY & INSTALLTION OF Mechnical Anchor Fastner (HILTY or evqlt make) Installtion of anchor fashner as per standard given by manufatuer Job including supply of Anchor Fasnter / with all tool like - drill machine / & other material reuired (other than not specified in item boq )
10 mm x 100 mm
10 mm x 150 mm
12 mm x 100 mm
Dismentling of Existing 3CX150 SQ.MM. HT 11KV (E) CABLE
Note: The item description in the BOQ is tentative and indicative in nature, bidder to understand the complete scope and quote accordingly.
ADISHWARAM CORPORATION
RAJEN ELECTRICAL
Manish Engicorp Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .