Loading…
Loading…
Tender Value
₹61.9 L
EMD Value
₹61,899
Closing Date
20 Jul 2026, 2:30 pmClosed
Commissioner
Rajamahendravaram Municipal Corporation
Supply, Delivery and Fixing of 500KVA CPCB IV+ DG Set Generator with required accessories at NRCP DP Station in 39th Division of RMC.
957514
85/MCR/General/2026-27
OPEN - NCB
Electrical Works
EAST GODAVARI
15 documents required · 14 mandatory · 1 optional
₹2,192
₹61,899
11 Jul 2026
4 Jul 2026
4 Jul 2026
Supply Installation Testing And commissioning of CPCB IV+ DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator 1. 1500 RPM, 1P or 3P, Brushless type, screen protected, revolving field, Self-excited alternator conforming to IS/IEC 60034-1 IP23, with standard Alternator Protection (over voltage, over speed & Under voltage) 2. A reliable long life with superior class 'H' insulation with temperature rise to Class H Diesel Engine: Engine: Engine should comprise of Silencer, Electronic governor from >25 KVA & above, suitable rating battery , Battery charging alternator, battery charger , Inbuilt Fuel tank with fuel pipe, AVM pads , Control panel with 3P MCCB of suitable rating with short circuit protections ( 25kA,36kA, 50kA) with microprocessor based controller indicating genset parameters ( i.e. volt, amps, KWH, KVAR, Hrs etc.), The diesel engine shall be capable of providing 10% overload for 1 Hr for every 11 Hrs of continuous running at full load. The DG set shall be supplied as per OEM specifications and shall be tested at site along with below. 1. CRDI Engine >25 KVA DG set 2. Water cooled Radiator coupled to engine 3. Dry type air cleaner with service indicator 4. First fill of lube oil, Coolant & first fill of Diesel 5. Electrical starter motor with soft start System 6. Battery charging alternator 7. Remote Monitor system >58.5 KVA & Above 8. 2 years / 5000 Hrs Warranty from commissioning or 30-month form supply. 9. Emission control system - EGR & (DOC, SCR for >75 KVA DG set) 10.10 Mtrs Exhaust pipe from Silencer
Genset Controller: 1. Microprocessor based genset monitoring, metering and control system with full graphics LCD display for easy front panel access. 2. AMF relay, manual and remote start / stop modes for 1-ph & 3-ph gensets 3. Backlit and full graphics display with power saving feature 4. Engine parameter monitoring -Lube oil pressure, Engine coolant temperature, Fuel level, Battery voltage, Engine running hours 5. AC Alternator parameter monitoring -Voltage L-N & L_L, Current, kW, kVA (Phase & Total), Frequency, kWH, PF 6. Genset Protection: Engine: Low lube oil pressure, High coolant temperature, Battery High/Low Volts, Fail to Start, Sensor failure, Low fuel level, Overspeed AC Alternator: Over/Under Voltage, Over/Under, Frequency, Loss of AC sensing, Over frequency, Over Current, kW Overload, Unbalancing load 7. Maintenance notification based on Engine Run Hour & due date 8. Communication: USB port, RS485, CAN 9. 30-50 Event logs Acoustic Enclosure: 1. Specially designed to meet stringent MOEF/CPCB IV+ norms 2. Weatherproof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.2 mm / 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.2mm /1.6 mm CRCA sheet and filled with PU Foam/Rockwood for Fire retardant acoustic and for better safety 3. Designed to operate in extreme climatic conditions in temperatures ranging from -10 deg to 55 deg without any external aid 4. Fabricated base frame with AVM pads. 5. Noise level is less than 75 db (A) at a distance of 1 Mtrs as per CPCB norms, complete in all respect. following capacity: Radiator Cooled and Turbocharged 500kVA at 0.8 pf 415V 50Hz 3-Ø Engine Makes:Caterpillar/Perkins/Cummins/Greaves/KOEL Alternator Make:Leroy somer/Crompton Greaves/Stamford including cost and conveyance of all materials to work spot and all operational, incidental charges, labourcharges etc., complete as directed by the departmental authorities.
Supply Installation Testing and Commissioning of AUTO MAINS FAILURE (AMF) Panel with IP 52 protection, fabricated from CRCA sheet steel 2mmThick , Powder coated finish , Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter ,4pole MCCBs for EB Supply and DG Supply of required rating and breaking capacity, automatic battery charger(External charger for DG) Control & Power Contactors, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: 320 to 500 KVA
Supply and transportation of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part - I)./1554-I Makes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt /KEC Asi+B8an Cables/Orbit/Avocab /Gemscab /Batra Henlay including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the departmental authorities.
Providing earthing as per IS 3043 with copper earth plate of size 600 x 600 x 3.15 mm by embodying 3 to 4 mtr below the ground level with 40mm dia 'B' Class G.I Pipe by excavating a pit to a depth of 3 to 4 Mtr in all soils for Sophisticated Electronic equipment as per National Electric Code and earth connection from electrode Copper strip of 25mm x 5mm x 200mm length to be bolted with nut bolts to G.I. pipe including 25mm x 3mm copper strip of 6Mtrs length connected from plate to Copper strip including filling with 20Kg Salt and 40Kg Charcoal or 40Kg bentonite powder including all accessories like nuts bolts reducer, nipple, wire meshed funnel and CC finished chamber covered with hinged type with CI cover ,CI frame of size 300 X 300 mm ,testing earth resistance as required including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the departmental authorities.
Providing independent earthing for Important equipment with 100mm dia Heavy gauge C.I ( Cast iron ) pipe with Flange 2.5m long enclosed in C.C/ brick masonry chamber of 450m x 450m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with salt and charcoal from the bottom of the pipe giving earth connection from electrode through G.I strip of 40 x 6mm x 200mm length with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II) including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the departmental authorities.
Supply & Making heat shrinkable outdoor straight through joint for 3.5 core x 300/400 sq.mm size of PVC/ XLPE insulated aluminum conductor cable of 1.1 KV grade including cost of compound, sleeves etc. as required. Makes: Raychem /M seal/ Denson/ Multy/ Transeal- Hongshang including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the departmental authorities.
Supply and making one end termination with heavy duty double compression brass gland as per BS 6121:2005, IP 66 complete, SIBG type, heavy duty Aluminum lugs duly crimped with crimping tool, PVC tape etc., for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminum conductor cable of 1100 volt grade as required of size. Makes:Dowels/Comet/SMI including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the departmental authorities.
Supply and laying of 25mm x 3mm Copper Flat (0.663Kgs/1Mtr) Earth wire/Strip in horizontal /Vertical run in Ground/surface/Recess including, riveting, soldering, saddles, making connection etc as required including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the departmental authorities.
Labour charges Layingof Cable including Earth work excavation of Trench in hard ground soil, laying of U.G cables from 70 sqmm to 400 Sq,mm on sand cushion covering the cable with bricks and back filling of Trench duly providing route indicator embedded in C.C including cost and conveyance of materials and labour charges etc., complete.
Supply and Transportation of Outer dia 120mm and Inner dia 103.5mm double walled corrugated HDPE duct made as per specification BSEN - 500 86/IS 14930 Part-II Makes: DURA LINE (Dura Guard)/Precision/CPE/Million(AJUSS) or any ISI make approved by CE Electrical.. including cost of material and conveyance to work spot etc complete as directed by the departmental authorities.
Supply of 630A ISI marked 4 Pole Change Over Switch on Load with open Execution as per IS:13947 Makes: Socomec / Lauritz Knudsen (formerly L&T) /HPL / Havells/ C&S / Legrand/ABB including cost of material and conveyance to work spot etc complete as directed by the departmental authorities.
Supply and laying of following sizes Earth wire/Strip in horizontal /Vertical run in round/surface/Recess including, revitting, soldering, saddles, making connection etc as requiredas required 25mm x 3mm Copper Flat (0.663Kgs/1Mtr) including cost of material and conveyance to work spot etc complete as directed by the departmental authorities for 50 mm x 6mm Copper Flat (2.680Kgs/1Mtr)
Labour charges for Skilled Electrician-2Nos and Helper (Electrical)-2Nos Scoper of work 1) cable termination for generator and panel including lugs with lugging and bolt and 2) load balancing of generator 3) Fixing of change over switch and necessary connection etc including necessary associated cable work as directed by the site engineer
PCC grade M20 (MORD) Providing Plain Cement Concrete Nominal Mix (1:2:4) using 20mm nominal size Graded hard stone aggregate, mechanically mixed, placed and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH. for Approaches etc. (for Mechanical Mixer) With Form Work
Providing impervious coat to exposed RCC roof slab surface with CM (1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, conveyance charges of materials and all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc., excluding seigniorage charges on all materials. Complete for finished item of work as per ss and as directed by the site engineer.
Mild steel, Structural steel, i.e., angles, channels & I-sections Etc.,Labour charges for fabricating all heavy steel works like Trusses, Stanchions, Heavy Beams and Girders including cost of welding rods, power charges, etc excluding cost of fixing in position including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the site engineer.
Earth work excavation in all kinds of Soils for Structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious materials and disposal upto a lead of 0.50Mtrs. Dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD/ 304 MORTH VP No. 484. For Manual Means
PCC grade M20 (MORD) Providing Plain Cement Concrete Nominal Mix (1:2:4) using 20mm nominal size Graded hard stone aggregate, mechanically mixed, placed and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH. for Approaches etc. (for Mechanical Mixer) With Form Work
Mild steel, Structural steel, i.e., angles, channels & I-sections Etc.,Labour charges for fabricating all heavy steel works like Trusses, Stanchions, Heavy Beams and Girders including cost of welding rods, power charges, etc excluding cost of fixing in position including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the site engineer.
Supply and fixing of Pre-painted Galvalume Trapezoidal Profile Roofing sheet with 0.50mm thickness, Coating: Alu-Zinc coating AZ150 GSM. Tensile Strength: 550 MPA. Paint coating: Regular Modified Polyester painting. Painting Thickness (Top): 18 to 20 Microns, (Bottom): 5 to 7 Microns. Sheet Width: 1.020, Length: Maximum 12 Meters with Regular Range Colours including cost and conveyance of all materials and labour charges etc., complete as per ss and as directed by the site engineer.
Supply Installation Testing And commissioning of CPCB IV+ DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator 1. 1500 RPM, 1P or 3P, Brushless type, screen protected, revolving field, Self-excited alternator conforming to IS/IEC 60034-1 IP23, with standard Alternator Protection (over voltage, over speed & Under voltage) 2. A reliable long life with superior class 'H' insulation with temperature rise to Class H Diesel Engine: Engine: Engine should comprise of Silencer, Electronic governor from >25 KVA & above, suitable rating battery , Battery charging alternator, battery charger , Inbuilt Fuel tank with fuel pipe, AVM pads , Control panel with 3P MCCB of suitable rating with short circuit protections ( 25kA,36kA, 50kA) with microprocessor based controller indicating genset parameters ( i.e. volt, amps, KWH, KVAR, Hrs etc.), The diesel engine shall be capable of providing 10% overload for 1 Hr for every 11 Hrs of continuous running at full load. The DG set shall be supplied as per OEM specifications and shall be tested at site along with below. 1. CRDI Engine >25 KVA DG set 2. Water cooled Radiator coupled to engine 3. Dry type air cleaner with service indicator 4. First fill of lube oil, Coolant & first fill of Diesel 5. Electrical starter motor with soft start System 6. Battery charging alternator 7. Remote Monitor system >58.5 KVA & Above 8. 2 years / 5000 Hrs Warranty from commissioning or 30-month form supply. 9. Emission control system - EGR & (DOC, SCR for >75 KVA DG set) 10.10 Mtrs Exhaust pipe from Silencer
Genset Controller: 1. Microprocessor based genset monitoring, metering and control system with full graphics LCD display for easy front panel access. 2. AMF relay, manual and remote start / stop modes for 1-ph & 3-ph gensets 3. Backlit and full graphics display with power saving feature 4. Engine parameter monitoring -Lube oil pressure, Engine coolant temperature, Fuel level, Battery voltage, Engine running hours 5. AC Alternator parameter monitoring -Voltage L-N & L_L, Current, kW, kVA (Phase & Total), Frequency, kWH, PF 6. Genset Protection: Engine: Low lube oil pressure, High coolant temperature, Battery High/Low Volts, Fail to Start, Sensor failure, Low fuel level, Overspeed AC Alternator: Over/Under Voltage, Over/Under, Frequency, Loss of AC sensing, Over frequency, Over Current, kW Overload, Unbalancing load 7. Maintenance notification based on Engine Run Hour & due date 8. Communication: USB port, RS485, CAN 9. 30-50 Event logs Acoustic Enclosure: 1. Specially designed to meet stringent MOEF/CPCB IV+ norms 2. Weatherproof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.2 mm / 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.2mm /1.6 mm CRCA sheet and filled with PU Foam/Rockwood for Fire retardant acoustic and for better safety 3. Designed to operate in extreme climatic conditions in temperatures ranging from -10 deg to 55 deg without any external aid 4. Fabricated base frame with AVM pads. 5. Noise level is less than 75 db (A) at a distance of 1 Mtrs as per CPCB norms, complete in all respect. following capacity: Radiator Cooled and Turbocharged 500kVA at 0.8 pf 415V 50Hz 3-Ø Engine Makes:Caterpillar/Perkins/Cummins/Greaves/KOEL Alternator Make:Leroy somer/Crompton Greaves/Stamford including cost and conveyance of all materials to work spot and all operational, incidental charges, labourcharges etc., complete as directed by the departmental authorities.
Supply Installation Testing and Commissioning of AUTO MAINS FAILURE (AMF) Panel with IP 52 protection, fabricated from CRCA sheet steel 2mmThick , Powder coated finish , Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter ,4pole MCCBs for EB Supply and DG Supply of required rating and breaking capacity, automatic battery charger(External charger for DG) Control & Power Contactors, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: 320 to 500 KVA
Supply and transportation of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part - I)./1554-I Makes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt /KEC Asi+B8an Cables/Orbit/Avocab /Gemscab /Batra Henlay including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the departmental authorities.
Providing earthing as per IS 3043 with copper earth plate of size 600 x 600 x 3.15 mm by embodying 3 to 4 mtr below the ground level with 40mm dia 'B' Class G.I Pipe by excavating a pit to a depth of 3 to 4 Mtr in all soils for Sophisticated Electronic equipment as per National Electric Code and earth connection from electrode Copper strip of 25mm x 5mm x 200mm length to be bolted with nut bolts to G.I. pipe including 25mm x 3mm copper strip of 6Mtrs length connected from plate to Copper strip including filling with 20Kg Salt and 40Kg Charcoal or 40Kg bentonite powder including all accessories like nuts bolts reducer, nipple, wire meshed funnel and CC finished chamber covered with hinged type with CI cover ,CI frame of size 300 X 300 mm ,testing earth resistance as required including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the departmental authorities.
Providing independent earthing for Important equipment with 100mm dia Heavy gauge C.I ( Cast iron ) pipe with Flange 2.5m long enclosed in C.C/ brick masonry chamber of 450m x 450m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with salt and charcoal from the bottom of the pipe giving earth connection from electrode through G.I strip of 40 x 6mm x 200mm length with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II) including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the departmental authorities.
Supply & Making heat shrinkable outdoor straight through joint for 3.5 core x 300/400 sq.mm size of PVC/ XLPE insulated aluminum conductor cable of 1.1 KV grade including cost of compound, sleeves etc. as required. Makes: Raychem /M seal/ Denson/ Multy/ Transeal- Hongshang including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the departmental authorities.
Supply and making one end termination with heavy duty double compression brass gland as per BS 6121:2005, IP 66 complete, SIBG type, heavy duty Aluminum lugs duly crimped with crimping tool, PVC tape etc., for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminum conductor cable of 1100 volt grade as required of size. Makes:Dowels/Comet/SMI including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the departmental authorities.
Supply and laying of 25mm x 3mm Copper Flat (0.663Kgs/1Mtr) Earth wire/Strip in horizontal /Vertical run in Ground/surface/Recess including, riveting, soldering, saddles, making connection etc as required including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the departmental authorities.
Labour charges Layingof Cable including Earth work excavation of Trench in hard ground soil, laying of U.G cables from 70 sqmm to 400 Sq,mm on sand cushion covering the cable with bricks and back filling of Trench duly providing route indicator embedded in C.C including cost and conveyance of materials and labour charges etc., complete.
Supply and Transportation of Outer dia 120mm and Inner dia 103.5mm double walled corrugated HDPE duct made as per specification BSEN - 500 86/IS 14930 Part-II Makes: DURA LINE (Dura Guard) /Precision / CPE /Million(AJUSS) or any ISI make approved by CE Electrical. including cost of material and conveyance to work spot etc complete as directed by the departmental authorities.
Supply of 630A ISI marked 4 Pole Change Over Switch on Load with open Execution as per IS:13947 Makes: Socomec / Lauritz Knudsen (formerly L&T) /HPL / Havells/ C&S / Legrand/ABB including cost of material and conveyance to work spot etc complete as directed by the departmental authorities.
Supply and laying of following sizes Earth wire/Strip in horizontal /Vertical run in round/surface/Recess including, revitting, soldering, saddles, making connection etc as required 25mm x 3mm Copper Flat (0.663Kgs/1Mtr) including cost of material and conveyance to work spot etc complete as directed by the departmental authorities for 50 mm x 6mm Copper Flat (2.680Kgs/1Mtr)
Labour charges for Skilled Electrician-2Nos and Helper (Electrical)-2Nos Scoper of work 1) cable termination for generator and panel including lugs with lugging and bolt and 2) load balancing of generator 3) Fixing of change over switch and necessary connection etc including necessary associated cable work as directed by the site engineer
PCC grade M20 (MORD) Providing Plain Cement Concrete Nominal Mix (1:2:4) using 20mm nominal size Graded hard stone aggregate, mechanically mixed, placed and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH. for Approaches etc. (for Mechanical Mixer) With Form Work
Providing impervious coat to exposed RCC roof slab surface with CM (1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, conveyance charges of materials and all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc., excluding seigniorage charges on all materials. Complete for finished item of work as per ss and as directed by the site engineer.
Mild steel, Structural steel, i.e., angles, channels & I-sections Etc.,Labour charges for fabricating all heavy steel works like Trusses, Stanchions, Heavy Beams and Girders including cost of welding rods, power charges, etc excluding cost of fixing in position including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the site engineer.
Earth work excavation in all kinds of Soils for Structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious materials and disposal upto a lead of 0.50Mtrs. Dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD/ 304 MORTH VP No. 484. For Manual Means
PCC grade M20 (MORD) Providing Plain Cement Concrete Nominal Mix (1:2:4) using 20mm nominal size Graded hard stone aggregate, mechanically mixed, placed and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH. for Approaches etc. (for Mechanical Mixer) With Form Work
Mild steel, Structural steel, i.e., angles, channels & I-sections Etc.,Labour charges for fabricating all heavy steel works like Trusses, Stanchions, Heavy Beams and Girders including cost of welding rods, power charges, etc excluding cost of fixing in position including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the site engineer.
Supply and fixing of Pre-painted Galvalume Trapezoidal Profile Roofing sheet with 0.50mm thickness, Coating: Alu-Zinc coating AZ150 GSM. Tensile Strength: 550 MPA. Paint coating: Regular Modified Polyester painting. Painting Thickness (Top): 18 to 20 Microns, (Bottom): 5 to 7 Microns. Sheet Width: 1.020, Length: Maximum 12 Meters with Regular Range Colours including cost and conveyance of all materials and labour charges etc., complete as per ss and as directed by the site engineer.
Details of Maximum amount reimbursable to the Contractor.
1. Provision for GST @18%
2. Provision for NAC @0.10%
3. Provision for Seigniorage Charges
4. Provision for DMF 30% on Seigniorage Charges
5. Provision for Merit 2% on Seigniorage Charges
stage.html
html • 0.01 MB
aoc.html
html • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.01 MB
Boq 07 NIT 85.xlsx
TENDER_DOCUMENT • 0.08 MB
DECLARATION 85.docx
TENDER_DOCUMENT • 0.02 MB
DOC.DOC
TENDER_DOCUMENT • 0.55 MB
Nit Elec 85.DOC
TENDER_DOCUMENT • 0.26 MB
PRINT 07 NIT 85.xls
TENDER_DOCUMENT • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .