Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKA 700158 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700158 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.0 L+₹9,370.40 (1.89%)Rejected-Finance P O SASINDA VILL KASHIYA P S BELDA WEST MEDINIPUR PIN 721445 | BELDA | PASCHIM MEDINIPUR | WEST BENGAL | 721445 | L2 | Rejected-Finance L2 | |
| 3 | L3₹5.2 L+₹28,173 (5.69%)Rejected-Finance CHANDURIA SIMURALI DIST NADIA PIN 741248 | NADIA | WEST BENGAL | 741248 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹11,545
Closing Date
24 Jan 2025, 3:00 pmClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
Emergency demolition restoration work at Bikash Bhawan Dismantling of existing Split and Cassettee type air conditioning ODU unit including installation at window lebel after repairing the same with necessary arrangement at Ground to 5th Floor of
2025_WBPWD_798043_1
WBPWD/EE/BED/e-NIQ-68/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Bikash Bhavan
Please refer Tender documents.
5 documents required · 5 mandatory
₹11,545
7 Feb 2025
9 Jan 2025
27 Jan 2025
16 Jan 2025
24 Jan 2025
16 Jan 2025
Amount
Dismantling of 1.5 ton/ 2.0 ton Air Conditioner outdoor unit (Split type) after gas locking arrangement with necessary tools & tackels and store in safe place & Re-installation the same of 1.5 ton/ 2.0 ton Air Conditioner outdoor unit with necessary arrangement as per direction of EIC
Dismantling of above 2.0 ton Air Conditioner outdoor unit after gas locking arrangement with necessary tools & tackels and store in safe place & Re-installation the same of Cassette Air Conditioner outdoor unit with necessary arrangement as per direction of EIC
Supply and Fixing of New of 1-Phase double row Outdoor Condenser Coil (Copper) for 1.5 ton AC machine in place of Old damaged one. [Make- Daikin/Blue star/ Voltas/Hitachi].
Supply and Fixing of New of 1-Phase Outdoor fan Motor in place of Old damaged one. [Make- Daikin/Hitachi/Bluestar].
SITC incl. vacuumization and Nitrogen of testing of following nominal size of soft/hard drawn Cu. refrigerant piping for Pac/ VRV/VRF/RAC system, complete with fitting, with adjustable ring type hanger supports, jointing/brazing incl. accessories, insulated with XLPE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. 5/8”(15.88 mm)dia(Soft drawn) Cu. Pipes(As per standard BS864 or ANSIB 16.22)incl. 19 mm thick insulation.
1/4” (6.4 mm) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19 mm thick insulation.
Supply and laying PVC Drain Pipe 25mm dia with 6 mm thick Nitrile Rubber Insulation. [Make:- Suprime/Oriplast]
Supply and laying of 1.1 kV grade copper unarmoured round cable of 3 core 2.5 sq. mm from IDU Unit to ODU Unit for the above mentioned AC Unit. [Make:- Polycab/Havells/Gloster/Finolex/KEI/RR Kabel/As per choice of EIC]
Supply & Filling of different type refrigerant gas given below: R-22 Gas (Make: Godrej/ Floron/Mafron)
Supply & Filling of different type refrigerant gas given below: R-32 Gas (Make: Godrej/ Floron/Mafron)
Supply & Filling of different type refrigerant gas given below: R-410 Gas/ R-410-A/R-290 Gas (Make: Godrej/ Floron/Mafron)
Supply & Fixing of 240V to 400V, +_ 5% tolerance, 40-50 MFD/ 50-60MFD, P2 type capacitor for different types of existing split AC machines. (Make: Saroda/Epcos)
Repairing & servicing of 1.5/2.0 Tr PCB board in place of damaged one as per direction of EIC.
Supply and fixing of New fan blade for 1.5/2.0 Tr capacity split type AC machine as per direction of EIC.
Supplying, fabrication & fixings MS Base Frame by 50mm X 50mm X 5mm angle and supporting angle of 50mm x 50mm x 6mm in each platform in the outer edge for transmitting the load centrally through 2 nos(50mm x 50mm x 6 mm) angle inserted into the existing wall incl. fibre sheet shade including 02 nos MS Flat (40mm X 5mm) with drilling 10 nos holes in set , cutting holes into the wall & grouting with M10 Fastnut (10 mm) for installation of outdoor unit of above mentioned AC machines as directed by E.I.C. The entire structure must be safe to carry out maintenance of ODU. for mounting of AC machine outdoor Unit with platform arrangement for proper maintenance for different floor in appropriate way. (appx 21.10 kg X 62 nos machines= 1308.2 kg)
Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. (This item should be executed only after prior approval of the Engineer-incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly. (a) 3.9 meter height
(b) Extra for additional 3.6 height or part there of
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
BARSHA ENTERPRISE (BID ID -6035857)
ROY REFRIGERATION (BID ID -6039283)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .