Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 LAdmitted-Finance | +5.00% | ₹1.2 L | L1 | Admitted-Finance |
Tender Value
₹1.1 L
EMD Value
₹2,300
Closing Date
12 May 2026, 4:00 pmClosed
Executive Engineer PWD Elect Division II Jodhpur
Executive Engineer PWD Elect Division II Jodhpur
AMC of lift at RAJ BHAWAN ,Mount Abu
2026_CEPWD_557999_4
NIT No.17 of 2026-27 of E.E. PWD Elect.Dn.II Jodhpur
Open Tender
Electrical Works
365 days
Jodhpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Executive Engineer PWD Elect Division II Jodhpur
₹2,300
Yes
Executive Engineer PWD Elect Division II Jodhpur
13 May 2026
10 May 2026
12 May 2026
10 May 2026
12 May 2026
10 May 2026
11 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | All in all comprehensive maintenance of the passenger /bed cum stretcher /goods elevator having various speed as per OEM guidelines and maintenance manual including car with all car accessories , hoist way accessories and complete with machine room /MRL accessories including replacement of diffused battery bank of ARD system as per following details . | - | - | - | - |
| 2 | 10 Passenger , 680 Kg Elevator up to 5 Stops | 12 | Job per Month | 9,040 | ₹1,08,480 |
| 3 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate. | - | - | - | - |
| 4 | 4 pole MCCB With Thermal Magnetic release | - | - | - | - |
| 5 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, | 1 | Each | 6,219 | ₹6,219 |
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
Tendernotice_2.pdf
PDF • 0.14 MB
Tendernotice_3.pdf
PDF • 1.12 MB
BOQ_993553.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid