| 1 | L1₹1.5 CrAccepted-AOC DEHRADUN VICTORIA CROSS VIJETA GABAR SINGH URJA BHAWAN KANWALI ROAD DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹1.5 Cr | L1 | Accepted-AOC QUALIFIED FOR AOC |
| 2 | L2₹1.5 Cr+₹2.4 L (1.57%)Rejected-Finance BARKOT UTTARKASHI | RUDRA PRAYAG | UTTARAKHAND | 246141 | ₹1.5 Cr+₹2.4 L (1.57%) | L2 | Rejected-Finance NOT QUALIFIED FOR AOC |
| 3 | L3₹1.6 Cr+₹5.3 L (3.46%)Rejected-Finance HARIDHAN COLONY VEERBHADRA HARIDWAR ROAD GUMANIWALA RISHIKESH | ₹1.6 Cr+₹5.3 L (3.46%) | L3 | Rejected-Finance NOT QUALIFIED FOR AOC |
Tender Value
Refer Docs
EMD Value
₹3.1 L
Closing Date
29 Mar 2023, 12:00 pmClosed
SUPERINTENDING ENGINEER
SUPERINTENDING ENGINEER,EDC KARANPRAYAG
REPLACEMENT OF EXISTING 33KV ACSR DOG CONDUCTOR WITH 33KV AAAC AL-59, 160 SQMM COVERED CONDUCTOR AT DIFFERENT WORK SITE FROM BURJALA TO NANDKESHARI UNDER EDD, NARYANBAGAR ON SEMI-TURNKEY BASIS.
2023_UPCL4_56138_1
53/EDC(K)/2022-23
Open Tender
Repair and Maintenance Works
Turn-key
180 days
NARAYANBAGAR
AS PER NIT
3 documents required · 3 mandatory
₹11,800
EE ETD KARANPRAYAG
₹3.1 L
24 Jul 2023
14 Mar 2023
31 Mar 2023
15 Mar 2023
29 Mar 2023
15 Mar 2023
SUPPLY OF MATERIAL PORTION
33 KV AAAC AL-59 , 160 sq mm Covered Conductor (As per EN- 50397-1:2006) .The conductor shall be stranded, round, non compacted and water tight. Non Compacted conductor shall comply with all the requirement of EN 50397-1-2006. The stranded conductor shall be longitudinally water blocked by means of a water blocking material.The semi conducting screen, inner insulation and outer insulation should be extruded in one step. The outer covering insulation shall be UV-stabilized, tracking resistant black XLPE.
MVCC Accessories (As per EN - 50397-2) as below:
33 KV Tension Clamp with bail & IPC
33 KV Cable Ties for Pin Insulator.
33 KV IPC for covered to covered connections
33 KV IPC for covered to Bare connections
33 KV Mid Span Jointing Kit
IPC with Aluminium Bail for earthing
33 KV Disc insulator for AAAC Covered Conductor
33 KV Pin Insulator 120 KN
PP Clamp for SP-55 with N&B
Stay Clamp for SP-55 with N&B
Bracing Clamp Top for SP 55 with N&B
Bracing Clamp Bottom For SP 55 With N&B
LABOUR PORTION
Cartage of following material from ESC to Road site of work dist. Apprx. 160 km Loading/unloading comp.
ST pole SP-55
Small Material
Head load cartage of following material from road site to work site dist. Apprx. 0-2 km Loading/unloading comp.
ST pole SP-55
Small Material
Fabrication of steel by cutting and drilling properly
Digging of pit for Pole as per upcl norms.(0.9*0.6*1/6 Pole Length)*Pole
Erection of new 33 KV D/P Structure as per upcl norms
Grouting of Pole as per norms (0.45*0.45*1/9 of pole length)*Pole
Digging of pit for stay as per upcl norms (0.6*0.6*1.20 Mtr)
Grouting of Stay as per norms (0.6*0.6*0.3)*stay
Erection of new 33 KV stay as per upcl norms
Removing of old conductor with opening of existing jumpering and making of bundle. Length of line 4.050 KM
Laying, spreading, stringing, sagging of 33 KV line in 3 Phase of the following wire as phase wire including proper sagging with binding and jumpering as per user manual and sagging comp. work done(Inclusive of cartage and head load cartage at work site).Rollers of the appropriate diameter and quantity have to to be provided for installation.The rollers shall have a smooth clean surface, no sharp edges and shall rotate easily.To prevent the covering from damage any abrasive contact with soil or stone is not permitted. Abrasive contact of the covering with branches or similar shall be avoided.Covered conductor shall be pulled by using appropriate pulling devices ensuring that the pulling force is distributed to the conductor.Recommendations given in EN-50397-3 should be followed for storage, transport and installation of covered conductor.
33 KV AAAC AL-59 , 160 sq mm Covered Conductor
Excavation of earth and erection of 33 KV single support with CC Comp.
Fixing of MVCC Accessories
33 KV Tension Clamp with bail & IPC
33 KV Cable Ties for Pin Insulator.
33 KV IPC for covered to covered connections
33 KV IPC for covered to Bare connections
33 KV Mid Span Jointing Kit
IPC with Aluminium Bail for earthing
33 KV Disc insulator for AAAC Covered Conductor
33 KV Pin Insulator
Chemical Earthing on pole structure (Existing/New)
Providing and fixing Danger board for 33 KV new structures
Providing and fixing Anti climbing device for 33 KV new structures
Back cartage of dismantled material from work site to work road side.Average distance 2 Km
Line material
Back cartage of dismantled material from work site to work road side.Average distance 2 Km
Line material
Aarna Electrical And Co
Raman electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .