Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L1 | Accepted-AOC Accepted - AOC | |
| 2 | L2₹43.5 L+₹6.1 L (16.3%)Rejected-AOC A 16 SHIV LOK COLONY RAJPUR ROAD DEHRADUN 248 008 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248008 | L2 | Rejected-AOC Rejected - AOC |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
10 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DEHRADUN
GE Dehradun, Mall Road, Garhi Cantt, Dehradun Tele 0135 2750580
Addition/alteration to MRS Anarwala and Garhi Cantt and Spl Repair to Pathway near Bldg No. P 23 of 2/9 GR under GE Dehradun
2020_MES_344822_3
8207/A/E8
Open Tender
Civil Works
Item Rate
120 days
GE DEHRADUN
Class D Cat a(i) and b(ii)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹86,000
Yes
17 Dec 2020
23 Jul 2020
12 Aug 2020
23 Jul 2020
10 Aug 2020
23 Jul 2020
60 days
Amount
Supply installation, testing and commissioning of outdoor type factory made cubical panel with1.6MM thick CRCA sheet duly powder coated, outdoor type (IP55), 33KV HT Vacuum Circuit Breaker (Make- ABB/Siemens/Schneider) 36KV rated capacity not less than 1250A, 31.5 KA breaking capacity, outdoor type, porcelain clad construction, mounted on and including hot dipped GI structure, suitable for direct connection to overhead line installed on PCC platform with step, comprising the following accessories:-
(a) 110V DC Volts tripping Coil -01 No.
(b) 110 V DC closing coil -01 No.
(c) Spring charging motor suitable for 230V AC -01 No
(d) Mechanical On/Off indicator showing spring charged and spring free position 01 set
(e) Mechanical trip and close lever -01 Set
(f) Cable terminal block located at safe distance inside the box for control cable -01 Set
(g) Auxiliary switch with 4NO+4NC contacts as recommended by the manufacturer
(h) Crank for manual charging spring -01 No
(j) Local and remote operation switch -01 No.
(k) 80 Watt 230V AC space heater with thermostat & switch -01 No
(l) Operation Counter -01 No
(m) Manual/Auto and local remote -01 Set
(n) Earthing terminals -02 Nos
(o) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations with height of plinth shall not be less than 0.9 M incl steps for approach to panel for manual operation.
Supply installation commission and testing of OEM partially type tested relay and control panel indoor type, suitable for 33 KV VCB of system voltage LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) and 110 Volts DC factory assembled, weather and vermin proof (Protection Class IP-54) fabricated out of 2.0 mm thick CRCA sheet with back side hinged opening, rubber lining, locking arrangement, powder coated externally and internally of shade RAL 7032 Siemens grey mounted on 75 medium channel frame incl cable glands, comprising the following accessories complete Make of Panel: Schneider/Legrand/SIEMENS/Venson/ABB
(a) 3 Pole micro processor based feeder protection relay with instantaneous 2 Nos over current (50, 50N) element and 1 No Instantaneous earth fault (50, 50N) (o/c setting 50% - 200% and earth fault setting 20 % - 80% having large LCD display of all the parameters ie all three phase current at a time, type of fault, fault history etc operating voltage 110 Volts DC -01 No Make Schneider Cat No MICOM P143 or Equivalent in ABB/Siemens/GE
(b) 3 pole Earth fault relay -01 No
(c) Auxiliary relay - 01 No
(d) Large size digital LED Volt Meter -01 No
(e) Large size digital LED Amp Meter -01 No
(f) Digital three line multifunction LED display meter -01 No
(g) CT Operated three phase trivector meter -01 No
(h) Mechanical ON/OFF indicator- 01 No
(j) Trip/charge switch -01 No
(k) Space Heater -01 No
(l) Cubical illumination lamp -01 No
(m) LED Indication lamps for Spring charge, Breaker ON/OFF, Trip, Healthy etc
(n) Hooter 01 No
(o) Instrument wiring with suitable size copper conductor cable and controlled with suitable size SP/DP/TP/FP AC/DC MCB's -01 Job
M&L for shifting of existing iron gantry girder / MS structure for mounting CT, PT, lightening arrester etc including earthwork, demolition of existing PCC and refixing the complete structure at new location including necessary earth work and PCC (1:2:4) and T&P all as specified and directed.
Supply and fixing of control cable LT PVC insulated with solid copper conductor armoured heavy duty 1100 volts grade of 2.5 Sqmm 4 core complete all as specified and directed .Make: Havells/Polycab/Grandlay.
All as per item No 4.00 here in above but 2.5 Sqmm 6 core
S&F PT 33 KV outdoor type single Phase oil cooled PT of ratio 33/rt3/110/rt3/110rt3 class 0.50-3, burden 50 VA, insulation level 70/170 KV voltage factor 1.2 continuous and 1.9 for 30 second confirming to IS 3156 complete all as specified and directed. Make: Pargati/AE/Kappa/ Siemens/Schneider.
S&F CT 33 KV outdoor type single Phase oil immersed self cooled having CT ratio 100/50/1+1A with copper double wound dual ratio to be fitted on LV side of transformer CT complete as per IS 2705 accuracy class-I burden 15 VA separate core for metering & separate core for protection duly calibrated according to load all as specified and directed. Make: Pragati/ Kappa/AE/Siemens/Schneider
Supply and fixing powder coated or hot dipped GI perforated type cable trays of size 100 mm wide x 40mm x 1.6 mm thick fixed to wall or iron gantry including all the tray accessories, supports, bends, anchor fasteners, GI hardware etc.
Taking down existing sectionalizer unit from four pole structure complete.
Taking down existing GOD switch from four pole structure complete.
Supply, install, testing and commissioning of manual operated , three position load break switch,factory made floor mounted, outdoor type enclosure of protection class IP-54 suitable for HT 11 KV 630 Amp 3 Phase ,3 wire earthed system , (Switching in SF 6 filled tank at 1.2 bare with manometer, pressure guage indicator having protection class IP 67) with rated Symmetrical Interrupting current 21KA, Rated Power frequency 50 dry withstand voltage 28 KV rms for 1 minute, Rated Power frequency wet withstand voltage 21 KV rms for 10 seconds, Rated lightning impulse withstand peak voltage (BID) 75 KV, capacity indication for incoming and outgoing copper busbar with interlocking switch and earthbar with earth switch complete. The breaket should be suitable for 240 Sqmm cable as incoming and outgoing complete all as specified an directed. Make:-ABB/Siemens/Schneider
M & L for switch air break gang operated triple pole out door type with drop out switch fuse unit on HT 11 KV 50 cycle AC suitable for current rating upto 200 Amps mechanically operated mounted on insulators (12 insulators, cast resin) and frame with operating mechanism workable from ground level including locking arrangement complete all as directed. Make :- Elpro/Pactil/Alstom/MEI/ATLAS/ Jaipuria/ BHEL
M & L for under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts (earthed) grade copper sheet wrapped cross sectional area 120 sqmm 3 core all as directed. Make:- Havell/Finolex/KEI/Polycab/Grandlay
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized wire 4 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 15 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed. NOTE 1. The unit rate includes for protection GI pipe 15 mm dia light grade and GI wire 4 mm dia from top of earth plate up to 7.5 meter above ground level.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized strip of 32x6 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed. NOTE 1. The unit rate includes for protection pipe 40 mm dia and GI strip 32x6 mm dia from top of earth plate up to 7.5 meter above ground level.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 Sqmm. Make:Denson/Reychem/3M Birla/ Havells
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft/loose soil complete all as specified and as directed.
Supply and lay dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete.
Demolition of cement concrete in ground floor and paving nexc 15cm thick (below or above ground level ) and removing rubbish off the MD land complete all as specified.
M&L for hard core of broken stone or boulder of gauge exc 63mm but n.exc 100mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and well rammed to a true surface complete all as specified and directed.
M&L for providing 75mm thick cement concrete (1:4:8) Nominal Mix (using 40mm grade stone aggregate) as in sub base of floor finished rough complete all as specified and directed.
M&L, Sand filling under floors or in foundation incvluding watering and consolidation etc complete all as specified and directed by engineer- in- charge
M&L for rubber moulded pre polished coloured machine pressed precast concrete interlocking paver block any shape and size fixed with gray cement and pigment confirming to IS15658-2006 of 60mm thickness M-35 grade all as specified and directed. Make:- NTC, Hiscon
M&L filleting exc 25 but n exc 50 sqcm in any position and to any shape in cement mortar (1:3) including all mtrs stops etc complete all as specified and directed.
Amit Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .