Executive Engineer
IPH Division Jawali
Replacement of old Pumping Machinery in various Lift Irrigation Schemes under IPH Sub Division Nagrota Surian SH SE of Pumping Machinery Submersible and Centrifugal along with allied accessories
2019_HPIPH_33480_1
EE/IPH/JWL/2019-11801-11850 dt. 19/12/2019
Open Tender
Civil Works - Water Works
Item Rate
90 days
Nagrota Surian
Please refer Tender documents.
6 documents required · 6 mandatory
₹400
EE Jawali
₹37,650
Yes
12 May 2020
20 Dec 2019
16 Jan 2020
21 Dec 2019
16 Jan 2020
21 Dec 2019
Amount
T/Well Blaod-II Supply of submersible pumping set of KSB/ Crompton / Johnston / BS/ Amrut/Kirloskar confirming to BIS - 8034 -1979 (latest) suitable for clear water fitted with bronze impellers or suitable alloys directly coupled to squirrell cage electric induction motor of same make as that of pump confirming to IS: 9238-1979 latest with up to date amendments ) and totally water proof for submersible duty.,isolated from the pump by intermediate casing with double mechanical seal in oil chamber grease packed lubricated bearing & provided with stainless steel thurst bearing plate to with stand non vertical loads with minimum wear & tear. It should also be fitted with device to a take up expansion of water with heating of motor including water level guard errection clamps, cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- ( 1 set of 40 HP)
Location of site :- The site is located at a distance of 4 Kms from Nagrota Surian Railway station to site of work.
The Altitude of place in which the motor is intended to work :- Altitude of phase is 400 mtr. Above mean sea level.
Type of current :- A.C. Three phase supply with frequency of 50 cycles per second.
Rated Voltage :- 415 (+/-) 10% Treated.
Charactrstics of water : - (a) Temperature 20°C (b) Turbidity upto 10 NTP (c) Hardness- Mg/Liter (as CaCo3) (d) Alkalinity Mg/Liter (as CaCo3) (e) PH= _______ (f) Total Solids ____ Mg/Litre (h) Other ______
Depth of well assembly 32.00 mtr.
L.W.L. in Tube-well 32.00 mtr
Centerline level of pump -----
Suction Head ________
Discharge level of highest point 404.50 mtr
No. of pump required 1 No
Discharge required from each Pump 31.70 LPS
Static head 4.20 mtr.
Total head in mtr 53.76 mtr.
Length of R/Main 291 mtr.
Dia of R/Main 200 mm dia
No of working hours P/day 16.00 Hours
Limits of pump operction ( - ) 15 % ( + ) 10 % of total head
H.P. Motor /drive unit: - BHP with following margins/multipying factor at duty point whichevear is higher (a) Up to 2 HP = 1.5 (d) 10 to 20 HP = 1.2 (b) 2 to 5 HP = 1.4 (e) 20 to 100 HP = 1.15 (c) 5 to 10 HP = 1.3 (f) Above 100 HP = 1.10
Test Run 8 hours Continueously for 7 days
Providing & fixing Cast Iron double flanged sulice valve of Kirloskar / Kilburn /IVC/ Fouress / Gled / BHEL/ Leader make of size suitable as per offered pump and class PN- 1.0 having one size higher to delivery size of pump and capable of with standing nominal seat pressure of 10.20 kg/Cm2. (as per IS -780-1984) ( The size of valve shall be specified by the Tenderer )
Providing & fixing of Cast Iron double flanged swing check type Reflex valve of Kirloskar / Kildurn / IVC / Fouress / Gled / BHEL/ Leader/ Kartar make having by pass arrangement suitable size higher to delivery size of pump( Size ____ mm & class PN-1.0 ) and shall be suitable for with standing nominal seat pressure of 10.20 Kg /Cm^2 ) ( sa per IS - 5312-1984 ( The size of valve shall be specifed by the tenderer )
Providing & fixing of Cast Iron double flanged swing check type Reflex valve of Kirloskar / Kildurn / IVC / Fouress / Gled / BHEL/ Leader/ Kartar make having by pass arrangement suitable size higher to delivery size of pump( Size ____ mm & class PN-1.0 ) and shall be suitable for with standing nominal seat pressure of 10.20 Kg /Cm^2 ) ( sa per IS - 5312-1984 ( The size of valve shall be specifed by the tenderer )
Providing and laying of suitable size copper PVC insulated armoured power 3.5 core cable .confirming to BIS 1554 (Part-I) 1988 of latest with up to date amendements of siemen / Gloster /ICC finollex make from meter of HPSEB-to-MCB / & from OCB to Busbar switch and starter (one cable carrying all three phases ) including all other electrical equipment /accessories such as thimbles ,flexible pipe solder ,nuts and bolts ,cable glands etc. laid in pipes of trenches under floor . The type size and make will be subject to approval of HPSEB autherities . In case of non -acceptance by HPSEB autherities it shall have to be replaced by the tenderer free of coat. a ) Supply side of size ____ mm Sqm
Providing and laying of PVC jointless flat water proof cable as per BIS,694-1990 (latest with up to date amendements ) suitable for the pump sets offered from OCB to motor , Motor to starter including all other electric equipment such as thimbles ,flexible pipe , solder , nut & bolt ,cable , glands etc . laid in pipes or trenches under floor . The type & make will be subject to approval of HPSEB authorities . In case of non acceptance by HPSEB authorities it shall have to be replaced by the tender free of cost. a ) Motor side of size ____ mm²
Providing and laying of double loop earthing with copper plate 600x600 x3mm thick electrode complete with material such as charcoal ,common salt ,G.I. pipe ,thimbles ,nuts and bolts .digging of pits ,G.I. wiring & 25x5 mm thick copper sterips of required capacity conforming to BIS 3043-1987 latest with up to date amendements for above motors and other electrical equipment.
Supply & Errection of floor / wall mounted power factor shunt capacitor conforming to BIS : 2834-1986 latest with upto date amendements L & T / BHEL/ GEC/ Machneil /Mager / Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of required KVAR according to HP of motor offered including cable siemens/Gloste/ICC make form busbar chamber to capacitor and also including L&T/LK/Kilburn make ICTP Switches conforming to BIS-4064-1978 or latest with HRC fuses.
Supply of standard make circular dial pressure gauge of suitbale rangs of Feibeg / Bourden / Precision make with all accessories such as stop cock copper tubing etc. Conforming to BIS: 3624-1987 latest with up to date ammendements.
P/Laying of column assembly of ______ mm dia MSERW pipe confirming to IS/ISO: 3183-2007 of steel grade L210 considering site requirement duly flanged at every 3 metre length with flanges conforming to BIS - 6392-1971/ BIS 1239 ( Table -17 ) including tapers , flanges , rubber , gasket 3mm thick as per BIS -2712-1978 , nuts & boult as per 1364-1983 & specials up to collection tank as per direction of Engineer in Charge as per layout approved by Engineer -in-charge .The pipe shall be capable of with standing 1.5 times the total pressure indicated in item No. 1 (xii ) NOTE :- Actual laying to be done as per final drawings to be approved by the Enginbeer-in- charge.
Erection of all equipment from Sr. No. 1 to 4, 6 includeing cost of tees, bends , tapers and any other fitting required as per site conditions and as per direction of Engineer- in - charge.
T/Well Samlota Supply of submersible pumping set of KSB/ Crompton / Johnston / BS/ Amrut/Kirloskar confirming to BIS - 8034 -1979 (latest) suitable for clear water fitted with bronze impellers or suitable alloys directly coupled to squirrell cage electric induction motor of same make as that of pump confirming to IS: 9238-1979 latest with up to date amendments ) and totally water proof for submersible duty.,isolated from the pump by intermediate casing with double mechanical seal in oil chamber grease packed lubricated bearing & provided with stainless steel thurst bearing plate to with stand non vertical loads with minimum wear & tear. It should also be fitted with device to a take up expansion of water with heating of motor including water level guard errection clamps, cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- (1 set of 35 HP)
Location of site :- The site is located at a distance of 4 Kms from Nagrota Surian Railway station to site of work.
The Altitude of place in which the motor is intended to work :- Altitude of phase is 400 mtr. Above mean sea level.
Type of current :- A.C. Three phase supply with frequency of 50 cycles per second.
Rated Voltage :- 415 (+/-) 10% Treated.
Charactrstics of water : - (a) Temperature 20°C (b) Turbidity upto 10 NTP (c) Hardness- Mg/Liter (as CaCo3) (d) Alkalinity Mg/Liter (as CaCo3) (e) PH= _______ (f) Total Solids ____ Mg/Litre (h) Other ______
Depth of well assembly 45.00 mtr.
L.W.L. in Tube-well 55.00 mtr
Centerline level of pump -----
Suction Head ________
Discharge level of highest point 103.75 mtr
No. of pump required 1 No
Discharge required from each Pump 23.00 LPS
Static head 13.75 mtr.
Total head in mtr 65.27 mtr.
Length of R/Main 280 mtr.
Dia of R/Main 200 mm dia
No of working hours P/day 16.00 Hours
Limits of pump operction ( - ) 15 % ( + ) 10 % of total head
H.P. Motor /drive unit: - BHP with following margins/multipying factor at duty point whichevear is higher (a) Up to 2 HP = 1.5 (d) 10 to 20 HP = 1.2 (b) 2 to 5 HP = 1.4 (e) 20 to 100 HP = 1.15 (c) 5 to 10 HP = 1.3 (f) Above 100 HP = 1.10
Test Run 8 hours Continueously for 7 days
Providing & fixing Cast Iron double flanged sulice valve of Kirloskar / Kilburn /IVC/ Fouress / Gled / BHEL/ Leader make of size suitable as per offered pump and class PN- 1.6 having one size higher to delivery size of pump and capable of with standing nominal seat pressure of 10.20 kg/Cm2. (as per IS -780-1984) ( The size of valve shall be specified by the Tenderer )
Providing & fixing of Cast Iron double flanged swing check type Reflex valve of Kirloskar / Kildurn / IVC / Fouress / Gled / BHEL/ Leader/ Kartar make having by pass arrangement suitable size higher to delivery size of pump( Size ____ mm & class PN-1.6 ) and shall be suitable for with standing nominal seat pressure of 10.20 Kg /Cm^2 ) ( sa per IS - 5312-1984 ( The size of valve shall be specifed by the tenderer )
Providing & fixing of Cast Iron double flanged swing check type Reflex valve of Kirloskar / Kildurn / IVC / Fouress / Gled / BHEL/ Leader/ Kartar make having by pass arrangement and size equal to dia of R/Main that is 200 mm dia and class -PN-1.6 ) and shall be suitable for with standing nominal seat pressure of 10.00 Kg /Cm^2 ) conforming to IS :5312-1984
Providing and laying of suitable size copper PVC insulated armoured power 3.5 core cable .confirming to BIS 1554 (Part-I) 1988 of latest with up to date amendements of siemen / Gloster /ICC finollex make from meter of HPSEB-to-MCB / & from OCB to Busbar switch and starter (one cable carrying all three phases ) including all other electrical equipment /accessories such as thimbles ,flexible pipe solder ,nuts and bolts ,cable glands etc. laid in pipes of trenches under floor . The type size and make will be subject to approval of HPSEB autherities . In case of non -acceptance by HPSEB autherities it shall have to be replaced by the tenderer free of coat. a ) Supply side of size _____ mm Sqm
Providing and laying of PVC jointless flat water proof cable as per BIS,694-1990 (latest with up to date amendements ) suitable for the pump sets offered from OCB to motor , Motor to starter including all other electric equipment such as thimbles ,flexible pipe , solder , nut & bolt ,cable , glands etc . laid in pipes or trenches under floor . The type & make will be subject to approval of HPSEB authorities . In case of non acceptance by HPSEB authorities it shall have to be replaced by the tender free of cost. a ) Motor side of size _____ mm²
Providing and laying of double loop earthing with copper plate 600x600 x3mm thick electrode complete with material such as charcoal ,common salt ,G.I. pipe ,thimbles ,nuts and bolts .digging of pits ,G.I. wiring & 25x5 mm thick copper sterips of required capacity conforming to BIS 3043-1987 latest with up to date amendements for above motors and other electrical equipment.
Supply & Errection of floor / wall mounted power factor shunt capacitor conforming to BIS : 2834-1986 latest with upto date amendements L & T / BHEL/ GEC/ Machneil /Mager / Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of required KVAR according to HP of motor offered including cable siemens/Gloste/ICC make form busbar chamber to capacitor and also including L&T/LK/Kilburn make ICTP Switches conforming to BIS-4064-1978 or latest with HRC fuses.
Supply of standard make circular dial pressure gauge of suitbale rangs of Feibeg / Bourden / Precision make with all accessories such as stop cock copper tubing etc. Conforming to BIS: 3624-1987 latest with up to date ammendements.
P/Laying of column assembly of _____ mm dia MSERW pipe confirming to IS/ISO: 3183-2007 of steel grade L210 considering site requirement duly flanged at every 3 metre length with flanges conforming to BIS - 6392-1971/ BIS 1239 ( Table -17 ) including tapers , flanges , rubber , gasket 3mm thick as per BIS -2712-1978 , nuts & boult as per 1364-1983 & specials up to collection tank as per direction of Engineer in Charge as per layout approved by Engineer -in-charge .The pipe shall be capable of with standing 1.5 times the total pressure indicated in item No. 1 (xii ) NOTE :- Actual laying to be done as per final drawings to be approved by the Enginbeer-in- charge.
Erection of all equipment from Sr. No. 1 to 4, 6 includeing cost of tees, bends , tapers and any other fitting required as per site conditions and as per direction of Engineer- in - charge.
LIS Sukhhar Supply & Errection of horizontal spindle, horizontal/ radial split casing and suction (backpull out arrangement ) single/ Double/ multi stage Centrifugal Pumps or combination of pumps in series / Parallel of KSB/ Kirloskar/ Mathar & Platt / Jyoti/ BE/ Beaconwire make conforming to BIS :1520-1980 (latest with upto date amendments) read with BIS :9137-1978 (latest edition) suitable for lifting clear water of under mentioned characteristics wih impellers of bronze/suitable alloy, priming funnels, casing ring & shaft sleeves of bronze /suitable alloy, shaft of suitable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be form the principle manufacturer of pumping set) to slippering /squired cage screen protected drip proof electric induction motor of KSB/ Kirlokar /Cropton /Sieman & Jyoti/ BE/ Beaconweir/ BHEL/ GEC/ ABB Conforming to BIS 325-1978 read with BIS: 900-1968 ( latest with upto date amendments ) It should include the cost of bearings . Nuts & bolts , painting etc. and shall be suitable for operation as per data given below. (3 set of 90 HP)
Location of site :- The site is located at a distance of 3 Kms from Nagrota Surian Railway station to site of work.
The Altitude of place in which the motor is intended to work :- Altitude of phase is 450 mtr. Above mean sea level.
Type of current :- A.C. Three phase supply with frequency of 50 cycles per second.
Rated Voltage :- 415 (+/-) 10% Treated.
Type of water (Raw/ Treated) Clear Water
Charactrstics of water : - (a) Temperature 20°C (b) Turbidity upto 10 NTP (c) Hardness- Mg/Liter (as CaCo3) (d) Alkalinity Mg/Liter (as CaCo3) (e) PH= _______ (f) Total Solids ____ Mg/Litre (h) Other ______
Depth of well assembly ___ mtr.
L.W.L. in J/Well 450.00 mtr
Centerline level of pump 0.00 mtr
Shaft level 450.00 mtr.
Discharge level of highest point 475.16 mtr
No. of pump required 3 Nos
Discharge required from each Pump 77.32 LPS
Residual head 3.00 mtr.
Static Head in mtr 25.16 mtr.
Total dynamic head 33.29 mtr.
R/Main 75 mtr.
Dia of R/Main 300 mm dia
No of working hours P/day 8.00 Hours
Limits of pump operction ( - ) 15 % ( + ) 10 % of total head
H.P. Motor /drive unit: - BHP with following margins/multipying factor at duty point whichevear is higher (a) Up to 2 HP = 1.5 (d) 10 to 20 HP = 1.2 (b) 2 to 5 HP = 1.4 (e) 20 to 100 HP = 1.15 (c) 5 to 10 HP = 1.3 (f) Above 100 HP = 1.10
R.M.P. of Pump (2900/1450) 2900 RPM
MNPSH available 450 M
Test Run 16 hours Continueously for 7 days
Providing & fixing Cast Iron double flanged sulice valve of Kirloskar / Kilburn /IVC/ Fouress / Gled / BHEL/ Leader make of size suitable as per offered pump and class PN- 1.0 having one size higher to delivery size of pump and capable of with standing nominal seat pressure of 10.20 kg/Cm2. (as per IS -780-1984) ( The size of valve shall be specified by the Tenderer )
Providing & fixing of Cast Iron double flanged swing check type Reflex valve of Kirloskar / Kildurn / IVC / Fouress / Gled / BHEL/ Leader/ Kartar make having by pass arrangement suitable size higher to delivery size of pump( Size ____ mm & class PN-1.0 ) and shall be suitable for with standing nominal seat pressure of 10.20 Kg /Cm^2 ) ( sa per IS - 5312-1984 ( The size of valve shall be specifed by the tenderer )
Providing & fixing of Cast Iron double flanged swing check type Reflex valve of Kirloskar / Kildurn / IVC / Fouress / Gled / BHEL/ Leader/ Kartar make having by pass arrangement and size equal to dia of R/Main that is 300 mm dia and class - PN-1.0 ) and shall be suitable for with standing nominal seat pressure of 10.00 Kg /Cm^2 ) conforming to IS :5312-1984
Providing & fixing Cast Iron double flanged sulice valve of Kirloskar / Kilburn /IVC/ Fouress / Gled / BHEL/ Leader make of size suitable as per offered pump and class PN- 1.0 having one size higher to delivery size of pump and capable of with standing nominal seat pressure of 10.20 kg/Cm2. (as per IS -780-1984) ( The size of valve shall be specified by the Tenderer )
Providing and laying of suitable size copper PVC insulated armoured power 3.5 core cable .confirming to BIS 1554 (Part-I) 1988 of latest with up to date amendements of siemen / Gloster /ICC finollex make from meter of HPSEB-to-MCB / & from OCB to Busbar switch and starter (one cable carrying all three phases ) including all other electrical equipment /accessories such as thimbles ,flexible pipe solder ,nuts and bolts ,cable glands etc. laid in pipes of trenches under floor . The type size and make will be subject to approval of HPSEB autherities . In case of non -acceptance by HPSEB autherities it shall have to be replaced by the tenderer free of coat. ( The size of cable shall be specifed by the tenderer ) a ) Supply side of size ____ mm Sqm
Providing and laying of PVC jointless flat water proof cable as per BIS,694-1990 (latest with up to date amendements ) suitable for the pump sets offered from OCB to motor , Motor to starter including all other electric equipment such as thimbles ,flexible pipe , solder , nut & bolt ,cable , glands etc . laid in pipes or trenches under floor . The type & make will be subject to approval of HPSEB authorities . In case of non acceptance by HPSEB authorities it shall have to be replaced by the tender free of cost. ( The size of cable shall be specifed by the tenderer). a ) Motor side of size_____ mm²
Providing and laying of double loop earthing with copper plate 600x600 x3mm thick electrode complete with material such as charcoal ,common salt ,G.I. pipe ,thimbles ,nuts and bolts .digging of pits ,G.I. wiring & 25x5 mm thick copper sterips of required capacity conforming to BIS 3043-1987 latest with up to date amendements for above motors and other electrical equipment.
Supply & Errection of floor / wall mounted power factor shunt capacitor conforming to BIS : 2834-1986 latest with upto date amendements L & T / BHEL/ GEC/ Machneil /Mager / Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of required KVAR according to HP of motor offered including cable siemens/Gloste/ICC make form busbar chamber to capacitor and also including L&T/LK/Kilburn make ICTP Switches conforming to BIS-4064-1978 or latest with HRC fuses. ( Range to be specified by the tenderers )
Supply of standard make circular dial pressure gauge of suitbale rangs of Feibeg / Bourden / Precision make with all accessories such as stop cock copper tubing etc. Conforming to BIS: 3624-1987 latest with up to date ammendements.
P/Laying of column assembly of ____ mm dia MSERW pipe confirming to IS/ISO: 3183-2007 of steel grade L210 of suitable size for suction, delivery and common header considering site requirement & NPSH required/ available. The pipe sizes for suction & delivery shall be as per the requirement of offered pump and common header shall be equal to dia of R/Main duly flanged at every 3 metre length with flanges conforming to BIS - 6392-1971/ BIS 1239 ( Table -17 ) including cost of tapers, flanges , bends, rubber gasket, 3mm thick as per BIS -2712-1978 , nuts & boult as per 1364-1983 & specials up to 5 mtr away from the outer wall of pump house as per direction of Engineer in Charge as per layout drawing approved by Engineer -in-charge .The pipe shall be capable of with standing 1.5 times the total pressure indicated in item No. 1 (xii ) ( The size of pipe shall be suppling by the tenderer ) NOTE :- Actual laying to be done as per final drawings to be approved by the Enginbeer-in- charge.
Suction pipe ---- mm dia ( To be mentioned by tenderer)
Delivery pipe --- mm dia ( To be mentioned by tenderer)
Common header --- mm dia ( To be mentioned by tenderer)
Erection of all equipment from Sr. No. 1 to 4, 6 includeing cost of tees, bends , tapers and any other fitting required as per site conditions and as per direction of Engineer- in - charge.
SS ENGINEERING WORKS
A.K. Traders
VIVEK KUMAR
M/S POLLY PHASE NEW ENGINEERING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .