PE(ENM) BIRSA PROJECT
OFFICE OF PE(ENM) BIRSA PROJECT
Electrical re-wiring of 50 Tone Weigh Bridge,situated at Hesa Bera under Birsa Project
2023_CCL_279874_1
PE(EnM)/BIRSA/e Tender/23-24/10 Dated 23/05/2023
Open Tender
Electrical and Maintenance Works
Item Wise
15 days
BIRSA PROJECT BARKASAYAL AREA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,400
20 Dec 2024
23 May 2023
3 Jun 2023
23 May 2023
2 Jun 2023
23 May 2023
Amount
Wiring for light point/fan point/exhaust fan point call bell point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthling the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit /sub main wiring along with earth wire with the following size of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required: 2x4.0 sq.mm. +1x4.sqr.mm.earth wire.
Wiring for circuit /sub main wiring along with earth wire with the following size of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required: 2x2.5sq.mm. +1x2.sqr.mm.earth wire.
Supply and fixing following piano type switch/ socket on the existing switch box /cover including connections etc. as required. '-5/6 Amp switch
3 Pin 5/6 Amp socket outlet
Supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenloic laminated sheet cover in front including providing sheet cover in front including providing & fixing 6 pin 5/6 & 15/16 amps socket outlet & 15/16 amps piano type switch connection painting etc as required.
Supplying and fixing 3 pin, 5 amps ceiling rose on the existing junction box/wooden block including connection etc as required.
Supplying and fixing brass batten/angle holder including connection etc. as required.
Supply and fixing stepped type electronic fan Regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
Supplying and fixing metal box of following sizes(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75mm X 75 MM X 60 MM Deep (Use for Bulb)
180mm X 100 mm X 60 mm deep (Use for 05 Amp Switch+Socket)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar earth bar, din bar, detachable Gland plate, interconnections, powder painted including earthing etc required. (But without MCB/RCCB/Isolator) - 8way, Double door
Supplying and fixing 5 amps to 32 amps rating 240 volts, ‘C’ curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB, DB complete with connection, testing and commissioning etc. as required. single pole
Supplying and fixing 5 amps to 32 amps rating 240 volts, ‘C’ curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB, DB complete with connection, testing and commissioning etc. as required.single pole & Netural
Supplying and fixing following rating,double pole, (Singla phase and netural), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Providing and Fixing Service Wire 4 Sq.mm 02 Core Copper
LED Bulb 12 Watt
LED Tube Light 20 Watt
Plug 15 Amp
Total impact of GST for the purpose of CTC
M/S OMPRAKASH MEHTA
RUDAL KUMAR SINGH
techsummary_289739.pdf
PDF • 0.06 MB
finsummary_289739.pdf
PDF • 0.06 MB
boqcomparativechart.pdf
PDF • 0.06 MB
finance_289739.pdf
PDF • 0.03 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .