Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC | ₹7.7 L Quoted ₹7.9 L | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹8.5 L+₹62,855.85 (7.98%)Rejected-Finance | ₹8.5 L+₹62,855.85 (7.98%) | L2 | Rejected-Finance Being other than lowest tenderer |
| 3 | L3₹8.6 L+₹77,086.55 (9.79%)Rejected-Finance | ₹8.6 L+₹77,086.55 (9.79%) | L3 | Rejected-Finance Being other than lowest tenderer |
| 4 | L4₹8.9 L+₹1.0 L (13.2%)Rejected-Finance | ₹8.9 L+₹1.0 L (13.2%) | L4 | Rejected-Finance Being other than lowest tenderer |
| 5 | surinder kumar jindal bros L5₹9.7 L+₹1.8 L (23.0%)Rejected-Finance | ₹9.7 L+₹1.8 L (23.0%) | L5 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
20 May 2020, 6:00 pmClosed
AGE(I) MES Dharamshala HP
AGE(I) MES Dharamshala HP
Special repair to Building No P-107 in Tirah Line at Mil Stn Dharamsala
2020_MES_331983_2
AGE(I)/DSL-57/2019-20
Open Tender
Civil Works
Item Rate
180 days
Military Station Dharamshala
As Per NIT
7 documents required · 7 mandatory
₹500
AGE(I) MES Dharamshala HP
₹19,000
Yes
8 Jun 2020
6 May 2020
22 May 2020
6 May 2020
20 May 2020
6 May 2020
Amount
Taking down chowkats with shutters of any description (without taking off shutters from the frames) not exc.1.5 sqm each, complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but not exc. 4.0 sqm each, complete all as specified and directed by Engr-in-Charge.
Taking down shutter of any description exc 1 Sqm and n exc 2 Sqm each,complete all as specified and directed by Engr-in-Charge.
Solid PVC door frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as per drawing shown on page No 160 of SSR Part-II (rates) and as directed by Engr-in-Charge. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
Factory made solid panel PVC door shutter 30 mm thick (stile) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of wood grain printed PVC sheet used instead of Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing on page No. 156 of MES SSR Part-II 2010, complete all as specified and directed by Engr-in-Charge.
Pressed steel frame of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc; complete all as specified and directed by Engr-in-Charge.
30mm thick 2nd class soft wood glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, Section 8 clause 8.24 (a) supplied and fitted to chowkhats complete, all as specified and as directed by the Engineer-in-Charge.
35mm thick,factory made, 2nd class hard wood ( Sal/Hallock) plain, framed, panelled shutter (two panels) with lock rail and panels of 9mm BWP commercial plywood or 12mm veneered particle with commercial face veneers on both sides. The size of rail and style as per IS-1003 (Part-I) Kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
Mild steel galvanised wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or wire staples or wooden beads complete, all as specified and directed by Engr-in-Charge.
100mm butt hinges, cast brass with mild steel hinge pin, bright polished and fixed type B-11, complete all as specified and directed by Engr-in-Charge.
150mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engr-in-Charge.
150mm long aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge.
300mm long, mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed by Engr-in-Charge.
Rendering 10 mm thick on fair faces of brick or concrete surface in CM 1:6, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Two coats of oil bound distemper on newly plastered surface of walls over a coat of chalk whiting including preparation complete all as specified and directed by the Engr-in-Charge.
Preparation of old decorated plastered or unplastered wall surfaces including cleaning by brooming down or with steel wire brushing, scrapping down smoke spot, moulds, moss and efflorescent salts and treating oil and greasy spots etc and applying one coat of oil bound distemper on walls over a coat of chalk whiting complete all as specified and as directed by Engineer-in-Charge.
Rendering 15 mm thick on fair faces of brick or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Supply only liquid water proofing compound complete all as specified and directed by Engr-in-Charge.
Applying two coats of all weather exterior paint over a coat of primer to newly plastered surfaces of wall including preparation etc., complete all as specified and directed by Engr-in-Charge.
5mm thick rendering in CM 1:3 on concrete surfaces as in ceilling, surface finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge.
Preparation of newly plastered surface of ceiling and applying two coats of oil bound distemper over a coat of chalk whitening complete, all as specified and directed by Engr-in-Charge.
Preparation of old decorated plastered or unplastered ceiling surfaces, including cleaning by brooming down or with steel wire brushing, scrapping down smoke spot, moulds, moss and efflorescent salts and treating oil and greasy spots etc and applying two coat of oil bound distemper on walls over a coat of chalk whitening, complete all as specified and as directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness laid in cement mortar complete all as specified and directed by Engr-in-Charge.
Glazed ceramic tiles premium class, grade-I as in vertical surface of size 300x200x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick bedding layer in cement mortar 1:4 on surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete in ground floors, in any position and pavings not exceeding 15cm thickness (below or above ground level) un-reinforced complete all as specified and directed by the Engr-in-Charge.
Plain Cement concrete, 25mm thick, M-15, type B-1(using 20mm graded crushed stone aggregates) as in floor finished roosh to receine floor finishes. complete all as specified and directed by Engr-in-Charge.
Mat finish (non skid) coloured tiles 7 to 8mm thick, straight edge, Premium Class I grade, area of each tiles exc.0.06 sqm but n.exc 0.11 sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge.
Mat finish (non skid) coloured tiles 7 to 8mm thick, straight edge, Premium Class I grade, area of each tiles exc.0.18 sqm but n.exc 0.38 sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge.
Machine cut, mirror polished 20-25 mm thick kota stone as in flooring, over 15mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing grinding and polishing complete, all as specified and directed by Engr-in-Charge.
Machine cut, mirror polished Kota stone slab 20-25mm thick as in vertical surfaces such as riser of steps, skirting, dado and pillar, jointed with grey cement slurry mixed with pigment to match the shade of the Kota stone slab including rubbing and polishing, laid over 10mm thick screed bed in cement mortar 1:3, complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, 75mm thick, M-7.5 (nominal mix), type D-2 (using 40mm graded crushed stone aggregate) as in sub base, foundation, filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
Plain cement concrete M-10, nominal mix type B-1 (using 20mm graded crushed stone aggregate) as in drain and surface channel, complete all as specified & directed by Engr-in-Charge.
Vitreous China wash hand basin, angle back, size 600x480mm white, including cutting for and pinning in ends of brackets or erecting stand,including 15mm bore pellar tap with 32mm chromium plated waste coupling, waste pipe of bore 32mm, PVC Connection pipe 450mm long with brass nuts on both side, complete all as specified and directed by Engr-in-Charge.
Vitreous chinaware squantting pan, ''Orrisa pattern'', size 580mm x 440mm white, with Cast iron 'P' or 'S' trap, front or back inlet, integral footrest excluding flushing cistern and flush type, etc and making good to floors (fixed in repair) complete all as specified and directed by Engr-in-Charge.
PVC valveless, crystal white, syphonic action type flushing cistern, 10 ltr capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32mm dia PVC long bend flush pipe 90cm long and 15mm dia 450 ling PVC Connection with CP brass coupling nuts and PVC washers at bothy ends fixed in repairs complete all as specified and directed by Engr-in-Charge.
Taking up or down steel water tubing and connections including cleaning for refixing or removal to store for 15mm bore tubing complete all as specified and directed by Engineer-in charge.
15mm bore GI steel water tubing, medium grade, galvanised with all fittings and fixtures fixed to wall and celling or laid in floor, complete all as specified and directed by Engr-in-Charge.
Taking up or down steel water tubing and connection, including cleaning for refixing or removal to store for 20mm bore tubing, complete all as specified and directed by Engr-in-Charge.
20mm bore GI steel water tubing, medium grade, galvanised with all fittings and fixtures fixed to walls and celling or laid in floor, complete all as specified and directed by Engr-in-Charge.
Re-fixing only for 15mm bore GI steel water tubing, medium grade with all fittings, laid under floors or fixed in wall complete all as specified and directed by Engineer-in charge.
Re-fixing only for 20mm bore GI steel water tubing, medium grade with all fittings, laid under floors or fixed in wall complete all as specified and directed by Engineer-in charge.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified and directed by Engr-in-Charge.
20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillar, window-cills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade of granite, complete all as specified and directed by Engr-in-Charge.
Sink made out of stainless steel 1mm thick for kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf including fixing cantilever brackets and connecting union to pipe over all size 495mm x 420mm bowl size 410mm x300mm x 160mm including 40mm size CP waste coupling & PVC waste pipe complete all as specified and directed by Engr-in-Charge.
Chequered cement concrete tiles maching pressed glossy finished (heavy duty) of size 300x300x30mm thick with grey cement and pigment set jointed & pointed in neat cement slurry in floors over 15mm thick screed bed in cement mortar 1:6 complete, all as specified and directed by Engr-in-Charge.
Removal of existing roof treatment with steel wire brushing and cleaning top surfaces of cement concrete and removing demolished material not exceeding 50m complete all as specified and directed by the Engr-in-Charge.
10mm thick cement plaster in cement mortar 1:4 on concrete surface of roof or terracing surface, finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge. (NOTE: WPC to be measured and paid separately).
Applying a coat of cement slurry @ 3Kg/ Sqm including preparation of surfaces, complete all as specified and directed by Engr-in-Charge.
Applying one coat of primer conforming to IS: 3384-1986 over plastered surfaces @ 0.40 litres/Sqm of density 0.87-0.89kg/litres at 25°C and viscosity 70-160CPS ( primer shall be of same make as of memebrane), complete all as specified and directed by Engr-in-Charge.
APP (Atactic Poly-propylene polymer) modified membranes, five layered, 3mm thick weighing not less than 3.5 kg/Sqm, having a centre core of polyester non-woven mat (FP) reinforcement dipped into APP modified mix and sealing all the over laps 75mm on length side and 100mm on width side of membranes by torching as per manufacture's instructions by authorised applicator , complete all as specified and directed by Engr-in-Charge.
Steel door including projecting type hinges, steel handle, complete all as specified and directed by Engr-in-Charge.
Steel window with side hung shutters including projecting type higes with steel handle and steel peg stay,complete with glazing bars, dovetailed or welded complete, all as specified and as directed by the Engineer-in-Charge.
Two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface of any description excluding 10cm width or girth, complete all as specified & directed by Engr-in-Charge.
Easing of steel windows, glazed and guazed including weldings etc complete all as specified and directed by Engr-in-Charge.
Mild steel peg stay for steel window complete, all as specified and as directed by the Engineer-in-Charge.
Mild steel handle for steel window complete, all as specified and as directed by the Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) form wooden frames or steel, concrete or brick surrounded, glazed with oil putty or fixed with beads complete, all as specified and directed by Engr-in-Charge.
3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in square n.exc.0.50 sqm in each pane complete, all as specified and directed by Engr-in-Charge.
Bib taps,15mm bore, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed (fixed in repairs) complete all as specified and directed by Engr-in-Charge.
Stop valve, 15mm bore, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions suitable complete, fancy type, chromium plated, complete all as specified and directed by Engr-in-Charge.
Shower rose, 125mm, Chromium plated, with or without swivel joints, any size, including fixing to steel pipe or union, (fixed in repair) complete all as specified and directed by Engr-in-Charge.
15mm bore, angle stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed in repairs complete all as specified and directed by Engr-in-Charge.
Tubular towel rail, 20mm dia, D-type, 60cm long between flanges aluminium anodised, (fixed in repairs) complete all as specified and directed by Engr-in-Charge.
Dismantling of cast iron or reinforced concrete drains pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed by the Engr-in-Charge.
Cast iron floor trap, 75mm bore, with grating including jointing to waste pipe fixed in cement concrete, M-15, type B-1 (fixed in repair), complete all as specified and as directed by Engineer-in- Charge .
100 mm bore sand cast iron soil waste and vent pipe in any length with or without ears, with cement joints, laid in trenches or floor etc complete all as specified and directed by the Engr-in-Charge.
All as per serial item No 68 here-in-above but fixed to walls etc; with brackets / clamps, complete all as specified and directed by the Engr-in-Charge.
75mm bore sand cast iron soil waste and vent pipe in any length with or without ears, with cement joints,laid in trenches or floors. complete all as specified and directed by the Engr-in-Charge.
All as per serial item No 70 here-in-above but fixed to walls etc; with brackets / clamps, complete all as specified and directed by the Engr-in-Charge.
50mm bore, sand cast iron soil waste and vent pipe in any length with or without ears, with cement joints, fixed to walls etc with brackets / clamps complete all as specified and directed by the Engr-in-Charge.
Cast iron Cowls 50mm dia, complete all as specified and directed by the Engr-in-Charge.
100mm bore CI 'P' or 'S' traps complete all as specified and directed by Engr-in-Charge.
75mm bore Cast iron bends (any radius), diminishing pieces or tapers (large bore measured) complete all as specified and as directed by Engineer-in-Charge .
75mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and as directed by Engineer-in-Charge .
100mm bore Cast iron bends (any radius), diminishing pieces or tapers (large bore measured) complete all as specified and as directed by Engineer-in-Charge .
100mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and as directed by Engineer-in-Charge .
Disconnecting water tanks, setting aside and re-hoisting, refixing in position after carry out roof repair including reconnection of capacity 500 ltr, complete all as specified and directed by Engr-in-Charge.
Dismantling water tanks of capacity exc. 250 ltrs & n.exc 500 ltrs, complete all as specified and directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank 500 Ltrs capacity (cylinderical vertical with closed top) including 15mm brass float valve & fly nut and make hoisted and fixed in position, complete all as specified and directed by Engr-in-Charge.
Preparation of old or new decorated plastered or unplastered wall surfaces including cleaning by brooming down or with steel wire brushing, scrapping down smoke spot, moulds, moss and efflorescent salts and treating oil and greasy spots etc and applying 3mm thick wall care putty, complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 82 here-in-above but on ceiling surface.
Curtain rods, harrsion, rails, mild steel, chromium plated with fixing brackets, stops, roller etc; complete all as specified and directed by Engr-in-Charge.
75mm thick PCC, M-10, type C-2 ( using 40mm graded crushed stone aggregates) as in plinth protection, finished even and smooth w/o using extra cement complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc including removing material for taking credit ( creditfor above items should be made as per conditions separately) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
Point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheathed FRLS electric cable 1100 volts cable and including PVC casing and caping of suitable size (as per conductor run) with all fittings/ accessories and including PVC insulated electric cable 1100 volts 1.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly including wooden box covered with 3 mm thick plastic laminated sheet ( Make Hylum) for one light point/ fan/exhaust fan point/ bell point etc controlled by one, one way switch,complete all as specified and as directed by the Engineer-in-Charge. Note : (i) New Sunken boxes wherever required shall be measured & paid separately. (ii) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost
All as per item No 87 here-in-above, but for one 3 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 87 here-in-above, but for one 3 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 87 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheathed electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
Socket outlet 2 in 1, 3 pin 5 Amp, flush type complete all as specified and as directed by the Engineer-in-Charge.
Socket outlet 2 in 1, 3 pin 5 Amp and 15 Amp, flush type complete all as specified and as directed by the Engineer-in-Charge.
Switch piano, flush type, single pole, one way,15Amp, complete all as specified and as directed by the Engineer-in-Charge.
Switch piano, flush button, 5 Amp, complete all as specified and as directed by the Engineer-in-Charge.
Bell push switch, flush button, single pole, one way 5 Amps complete all as specified and as directed by the Engineer-in-Charge.
Call bell, ding dong, AC 230 volt, single pole, complete all as specified and as directed by the Engineer-in-Charge.
Sub main wiring, two single core, PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC casing caping with 1x4 Sqmm PVC copper conductor cable as in earth wire system, including taking out old wiring complete all as specified and as directed by the Engineer-in-Charge.
Ceiling rose, surface type, 65 mm x 50 mm, two to three terminals/ PVC/ polycarbonate, isolated body fixed on PVC block, complete all as specified and as directed by the Engineer-in-Charge.
Replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 12 way double door type with 200 amp rated bus bar complete all specified and as directed by the Engineer-in-Charge. Note: (i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) The disturbed surface shall be match with existing surface. Make: Havells/Legrand/Heggar.
MCB SPN 40 Amp , 240 volt breaking capacity 10 KA complete, all specified and as directed by the Engineer-in-Charge.
MCB SP 6 to 32 Amp , 240 volt breaking cacacity 10KA. complete, all specified and as directed by the Engineer-in-Charge.
Universal batten, suitable for indoor applications LED tube light fitting 1x18 Watt 4 FT complete, Trim LED NEO including all fixing arrangement complete, all as specified and as directed by the Engr-in-Charage. Make:-Havells Cat Part No.reGalBattert5uPto1X18WdsBsWH or equivalent in Philips/ OSRAM/Bajaj.
LED tube light with very high efficiancy suited for installation in existing batten complete all as specified and as directed by the Engr-in-Charge. Make: Havells CAT Part No. Crystal 1213 t8dst18wled865s Glass or equivalent in Philips/OSRAM/Bajaj.
Efficient LED batten suitable for indoor applications tube light fitting 1x10 Watt 2 Ft, complete all as specified and as directed by the Engr-in-Charge. Make: Havells CAT Part No. LUMILINEPLUSBS10WLED865SPCSS or equivalent in Philips/Bajaj.
1X25 watt LED street light fitting with lamp, pressure die cast housing with epoxy powder coated dark graphite grey colour finish, prismatic polycarbonate cover with individual LED lenses with GI pipe 1.5mtr length, clamps nuts, bolts complete, all as specified and as directed by the Engr-in-Charage. Make: Crompton Cat part No. LSTS 25CDI LED or equivalent in Philips/Syska.
Angular type lamp holder, PVC/ polycarbonate type with back plate suitable for batten fitting, including plastic square board of required size complete all as specified and as directed by Engineer-in-Charge.
LED Lamp, pin type, 9 watt, complete all specified and as directed by the Engineer-in-Charge. MAKE: Polycab cat part No. LLP0101051 AELIUS LX LED LAMP 9W BC 6500 K or equivalent in Bajaj/CG.
Taking down and re-fixing, connecting existing electric meters, single phase complete all specified and as directed by the Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick burried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40x40x6mm and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate complete all as specified and shown in EP-3 of SSR Part-I & as directed by Engr-in-Charge.
Supply, jointing, fixing or passing through pipe, trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 25 Sqmm 3.5 core for working voltage upto including 1100 volts confirming to IS-7098 (Part-I) 1988 (Compaction Conductors shall be shaped and arrangement for the same shall be on the cable), complete all as specified & directed by Engr-in-Charge. and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out , for foundation of pipe line and pit etc in any type of soil ,complete all as directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm thick, complete all as directed by Engineer-in-Charge.
Removing excavated surplus material to a distance n.exc. 50 m and depositing where directed at a level n.exc 1.5m above starting point complete all as specified & directed by Engineer-in-Charge.
Sand cushioning to underground cables complete all as specified in clause 19.75 of SSR Part-I laid before and after laying of cables,complete, all as specified and as directed by the Engr-in-Charage.
Sub class 'B' bricks, old size, brick covering laid dry, flat transversally along the length of cable on sand cushioning, with width equal to the length of the brick complete all as specified and directed.
GI tubing, light grade with all fittings laid in trenches or under road crossing or fixed along walls /poles/pipes for post top lantern as protection pipe with clamps, nuts, washer bolts (where necessary) bore of pipe 40mm, 0.30 cm below ground level and 1.5 m above ground level, including two coats of super enameled synthetic white paint on GI pipe as per reqmt of site complete all as specified.
Supply & fix (in replacement ) of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of TPN 4 way double door type ( 01 incoming & 04 outgoing) with 200 amp rated bus bar complete all specified and as directed by the Engineer-in-Charge. Note: (i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) The disturbed surface shall be match with existing surface. Make: Havells/Legrand/Heggar.
Supply and fix (in replacement) of MCB TPN 63 Amp complete all specified and as directed by the Engineer-in-Charge.
Geyser (water heater storage type), electrical, capacity 25 litres. BEE 5 star rated, vertical type including giving inlet & outlet connections, testing & commissioning etc; complete all as specified and as directed by the Engineer-in-Charge. Make: Jaquar model Elena/ Racold Model ALTRO 2/ Venus model wave.
Cutting, screwing, alterations and additions in existing GI pipe of size 15mm dia including clamps, screws etc.complete all as specified and directed by Engr-in- Charge. Note:- The disturbed surfaces will be made as per existing surfaces without any extra cost.
M/S MADAN GOPAL and CO
KISHAN CONTRACTOR
VIJAY KUMAR LAKHNI
surinder kumar jindal bros
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .