Loading…
Loading…
Tender Value
₹57.6 L
Closing Date
2 Sept 2026, 4:00 pm6d left
R G DESAI
Tender For Bi-Annual ARC for Erection of 66KV S/S Equipment, Structures, Control wiring etc. work for 66KV Line Bay 66kv TR bay works at Various 66kv Sub-Station under Himatnagar Construction Division.
337044
2026-27/HTC / 44
Open
Electrical and Maintenance Works
Works
Sabarkantha
16 documents required · 16 mandatory
₹5,900
GETCO,Himatnagar
20 Aug 2026
20 Aug 2026
20 Aug 2026
2 Sept 2026
20 Aug 2026
NAME OF WORK: Tender For Bi-Annual ARC for Erection of 66KV S/S Equipment, Structures, Control wiring etc. work for 66KV Line Bay / 66kv X'mer bay works at Various 66kv Sub-Station under Construction
Division under R & M / KSY / O&M Works.
GUJARAT ENERGY TRANSMISSION CORPORATION LTD.
TRANSMISSION CIRCLE ,HIMATNAGAR
Name of Work :- Tender For Bi-Annual ARC for Erection of 66KV S/S Equipment, Structures, Control wiring etc. work for 66KV Line Bay / 66kv X'mer bay works at Various 66kv Sub-Station under Construction Division
under R & M / KSY / O&M Works.
Erection of structure,Equipment, control wiring for 66 kv Line Bay
S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S Total
Sr no Description of work Unit Rate Amount
Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty
Erection of 66KV Breaker (Any type / Make) including
supporting structure & fixing all its accessories, fittings,
connections etc. complete as per owner's/supplier's
manual and instruction of E.I.C. including individual &
1 interpole wiring of operating box and that with M.K.Box. 1 1 1 1 1 1 1 1 1 1 1 1 1 4 2 19 5535
with assisting to the erection engineer Erection without
crane is permitted. Rates are inclusive of
dragging/loading/unloading of same from site store to
Erection of 66KV CT/PT (all type make) on its erected
structure including complete dragging/ loading/ unloading
of same from site store to erection site and fixing of
required clamps, connectors as per instructions of E.I.C.
Erection of 66KV LA (All type/make) on its erected
structure including complete dragging/loading/ unloading
3 of the same from site store to erection site and fixing of Phase 3 3 3 3 3 3 3 3 3 3 3 3 3 12 4 55 415
required clamps, connectors, corona rings, surge counter
and other accessories etc. as per inst. of E.I.C.
Erection of 66KV Centre Break Isolator (All make) with
earth blade on its erected structure consisting of 3 base
channels with porcelain/solid core insulator including
interconnected piping with operating mechanism and Set of
accessories with final adjustment for simultaneous pole
operating & closing. The rates are inclusive of dragging /
loading / unloading of the same from site store to erection
site as per instruction of E.I.C.
5 - - DO - - as above but without earth blade complete. 1 1 1 1 1 1 1 1 1 1 1 1 1 4 2 19 2491
Erection of 66KV Poly cone/Solid Core/Bus Post Insulator
on its erected structure including minor required
6 fabrication & complete fixing of accessories and shifting of No 1 1 1 1 1 1 1 1 1 1 1 1 1 4 16 33 277
same including loading/ unloading from its site store to
Erection of Structure for Equipment/Lighting Mast/ VHF
Mast including punching of nut bolts. Rates are inclusive
7 of minor required fabrication and shifting of same up to MT 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 14 20 79.5 2491
erection site from its s/s Store. including Stub Setting as
per instruction of EIC..
Stringing of Twin Moose/Zebra Bus complete in all respect
8 with fixing of all fitting, insulators sag compansating spring 0 0 0 0 0 0 0 0 0 0 0 0 0 0 120 120 110
and all accessories as per the instruction of E.I.C.
Stringing of Single ACSR Moose/ Zebra Bus complete in all
9 respect with fixing of all fitting, insulators and all 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 100 63
accessories as per the instruction of E.I.C.
Stringing of Single Panther Bus complete in all respect with
10 fixing of all fitting, insulators and all accessories as per the 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 100 52
instruction of E.I.C.
Stringing overhead earthwire in switch yard in s/s structure
11 including jointing, jumpering, tensioning, clamping, etc.. Rmt 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 100 31
Complete as per E.I.C.
Preparing and fixing of required length of Jumpers of
Single ACSR Moose/Zebra/Panther type conductor in the
12 switchyard on respective Bus & equipments, tensioning, 150 150 150 150 150 150 150 150 150 150 150 150 150 600 300 2850 16
Compressing & dressing of jumpers complete as per
instruction of E.I.C.
Installation of Earthing Strips / MS Round Bar as shown
below including digging of 600 mm Deep and 450 mm Wide
Trench in any kind of soil expects Rocky(HR/SR) / Fixing on
Structures as per attached drawing including fixing
arrangement with Two Bolt Arrangement , Jointing with
Nut Bolts and Lap Welding and applying Zinc Rich Paint on
welded joints including supply of GI Nut & Bolts as per
specification and approved Earth Mat Lay Put.
Providing & fixing, Testing and Commissioning of
Maintenance Free Treated Earth Electrodes suitable for
Normal soil as per drawing no GETCO /E/P-021(1 OF 2) R2
DT 04.06.2015 and technical specification GETCO/E/TS-
maintenance free earth pits/R1 dated 04.06.2015 for 66/11
kv substation with ground enhancement material/back
14 fill/grounding compound as per IEEE 80-2000 CLAUS No 5 5 5 5 5 5 5 5 5 5 5 5 5 20 0 85 13893
14.5(d) and as per part 7 of IEC 62561 using copper
bounded earth electrode(with 250 micron copper
coating)having 24 mm (mim) and 3000 mm length which
shall be capable of handling STC of 25 KA-1 sec work also
include Providing BB masonry inspection chamber(man
hole) incl. light type CI cover
Providing & fixing, Testing and Commissioning of
Maintenance Free Treated Earth Electrodes suitable for
Normal soil as per drawing no GETCO /E/P-021(1 OF 2) R2
DT 04.06.2015 and technical specification GETCO/E/TS-
maintenance free earth pits/R1 dated 04.06.2015 for
132,220 & 400 kv substation with ground enhancement
15 material/back fill/grounding compound as per IEEE 80- No 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 10 18171
2000 CLAUS 14.5(d) and as per part 7 of IEC 62561 using
copper bounded earth electrode(with 250 micron copper
coating)having 24 mm (mim) and 3000 mm length which
shall be capable of handling STC of 25 KA-1 sec work also
include Providing BB masonry inspection chamber(man
hole) incl. light type CI cover
Erection of 66KV Control Panel, Relay panel or C/R Panel
or RTCC Panel including grouting of panel, jointing with
16 adjoining panels with providing required B/N including No 1 1 1 1 1 1 1 1 1 1 1 1 1 4 2 19 691
required fabrication for joining panels & entry of control
cables and complete vermin proofing.
Minor Fabrication for erection of any Equipment /Structure
17 /Panel or anywhere in sub stations as well as at opposite 1 1 1 1 1 1 1 1 1 1 1 1 1 4 1 18 4992
end substation also Inst. Of E.I.C.
Providing of M15 Grade Concrete for various equipment
structure, Guy, 11kv DP, M.K. Box, Neutral channels, cable
support channel, grouting of Pole/ Flood light structure
18 with cement, sand & metal in proportion of 1:2:4 Cmt 3 3 3 3 3 3 3 3 3 3 3 3 3 12 6 57 5276
respectively. The rates are inclusive of supply of sand,
metal, water & cement ,Muffing and with smooth cement
mortar (1:6) finish.
Loading, Transporting & Unloading of all SS material like SS
Structure, indoor & out door SS Equipments, DP Structure,
earthing materials etc.for SS & opposite end feeder bay -
Store to SS Site
20 P & F radium stiker for outdoor & indoor equipment Sq. inch 25 25 25 25 25 25 25 25 25 25 25 25 25 100 50 475 2
identification like LA ,Icolater, Circuit breaker ,Transformer,
CT, PT, MK Box , CR panel ,11 kv Panel etc..
Providing and fixing of ISI marked Insulating Mattysheet
Suitable for 11KV Class As per following specification.
Reference IS:15652-2006 with latest amendment. Suitable
for Voltage Class :B Max Use Voltage : 11KV
AC proof voltage : 22KV Leakage current : < 10 micro
ampere Colur RED/BLUE
Make : Vardhman or equivalent ( Rubberhouse India)
Width :1 mtr. Thickness :2.5 mm. Surface :Chequred
on one side and other side plain. NOTE: Contractor has to
supply Rubber Matty strictly as per IS:15652-2006 with
latest amendment specification and shall submit test
certificate for routine test as per relevant IS
Preparing of complete schedule of wiring for line/
transformer bay for 66KV bays in triplicate. necessary
drawing will be provided by the GETCO. Schedule should
be approved by EE. or DE in charge.
Laying of Control Cable Up to 7 Core, 1.1KV PVC, armored
copper/ aluminum control cable in readymade cable
trench and inside Hume pipe including binding / clamping
23 of cable with GI wire or saddles as per the requirement Mtr 300 300 300 300 300 300 300 300 300 300 300 300 300 1200 1000 6100 6
including the supply and fixing of identification tags at both
ends in between if required to following size (Cable will be
supplied by GETCO at free of cost)
24 As above but for, Above 7 Core Control Cable Mtr 400 400 400 400 400 400 400 400 400 400 400 400 400 1600 1500 8300 10
Laying of Control Cable Up to 7 Core, 1.1 KV PVC armored
copper /aluminum cable in ground by digging trench of
25 suitable width and 450 mm depth in any type of soil Mtr 70 70 70 70 70 70 70 70 70 70 70 70 70 300 200 1410 21
including supply and fixing of identification tag on both end
and at distance every 100 mtrs for
26 As above but for, Above 7 Core Control Cable Mtr 60 60 60 60 60 60 60 60 60 60 60 60 60 250 200 1230 26
Providing and fixing 'B' class G.I. pipes of following size for
cable protection including fixing with the structures.( Non
SOR) including required 'L' & 'T' band, coupling for CT,PT,
27 Transformer, M.K.Box cabling on structure including
required fabrication.(weight of pipe-25kg/meter)
Termination of Control Cable at Panel / M.K./ Equipments
including supply of required size of brass cable glands, lugs,
ferrules, PVC Binding Tape, Buttons etc. Up to 7 Core
29 As above but Above 7 Core Control Cable., End 16 16 16 16 16 16 16 16 16 16 16 16 16 64 40 312 349
Providing and fixing of all weather proof, cold rolled sheet
steel Junction Box for CVT & PT, CT terminations with
Nos. of disconnecting type, 'Elmex' make CATDM 4 or
equivalent type connectors and required no of fuses, links
etc.as per instruction of Engineer-in-charge and as per
drawing enclosed here with
Providing & Fixing of Single Piece Cast Alluminium with full
frame with Acrylic Cover integrated efficet flood light on
31 swedge pole/GI structure by providing required structure No 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 17 7487
etc for 1*250 watt etc.. 4 core 2.5 sq mm double insulated
flexible standard wire.
I we am / are willing to carry out the above work at_______________________________________ % above / below (percentage)
should be written in figures and words. ___________________________________________________________Percentage above /
below the tender amount work out Rs. ______________________________________________Rupees in
Signature of Contractor,
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2026-27 HTC 44 Tech Bid.pdf
2026-27 HTC 44 Price Bid.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].