Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.9 LAccepted-AOC MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹47.8 L+₹5.5 L (13.0%)Rejected-AOC NIL | L2 | Rejected-AOC Become L2 | |
| 3 | L3₹51.0 L+₹8.8 L (20.8%)Rejected-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L3 | Rejected-AOC Become L3 | |
| 4 | L4₹58.1 L+₹15.9 L (37.6%)Rejected-AOC | L4 | Rejected-AOC Become L4 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
29 May 2021, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Chariali Tezpur
REPAIR/MAINTENANCE OF DG SET WITH AMF PANEL AND ALLIED WORKS AT ZONE 1, ZONE 2, ZONE 3(A AND B), ZONE 4, ZONE 5 AND 1 (A,B,C) UNDER GE (S) TEZPUR
2021_MES_440248_1
8568
Open Tender
Civil Works
Item Rate
270 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹1 L
Yes
18 Jun 2021
4 May 2021
31 May 2021
4 May 2021
29 May 2021
17 May 2021
Amount
Maint and servicing of DG set 320 KVA conopy type with AMF Panel , in through authorise service agency of OEM ,Make- Cummins, including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of POL tank and radiator etc all as specified and directed :- (Note spares required for above maint will be measured and paid separately under relevent items of Sch):Location: HQ-4 Corps
Maint and servicing of DG set 200 KVA conopy type in through authorise service agency of OEM ,MakeGREAVS COTTON Ltd, including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner and CTC, including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water etc for the following capacities of DG sets all as specified and directed :- (Note spares required for above maint will be measured and paid separately under relevent items of Sch)Location: HQ-4 Corps
Maint and servicing of DG set125 KVA conopy type with AMF Panel in through authorise service agency of OEM ,Make- kirloskar, including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner and CTC, including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water etc for the following capacities of DG sets all as specified and directed :- (Note spares required for above maint will be measured and paid separately under relevent items of Sch)Location: Signal Center.
Maint and servicing of DG set140 KVA conopy type in through authorise service agency of OEM ,MakeKirloskar, including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner and CTC, including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water etc for the following capacities of DG sets all as specified and directed :- (Note spares required for above maint will be measured and paid separately under relevent items of Sch)Location: Zone 1
Maint and servicing of DG set 100 KVA through authorise service agency of OEM ,Make- Kirloskar, including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner and CTC, including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water etc for the following capacities of DG sets all as specified and directed :- (Note spares required for above maint will be measured and paid separately under relevent items of Sch)Location: NFS node signal complex, Laxman marg
Maint and servicing of DG set 62.5 KVA conopy type through authorise service agency of OEM ,Make- Kirloskar, including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner and CTC, including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water etc for the following capacities of DG sets all as specified and directed :- (Note spares required for above maint will be measured and paid separately under relevent items of Sch)Location: 4COSR, Bihuguri and 02 nos HQ 4 Corps, 4 Cosr
. Maint and servicing of DG set 30 KVA conopy type through authorise service agency of OEM ,Make- Kirloskar, including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner and CTC, including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water etc for the following capacities of DG sets all as specified and directed :- (Note spares required for above maint will be measured and paid separately under relevent items of Sch)Location: 5 TAC MT HQ 4 Corps
Maint and servicing of DG set 40 KVA conopy type through authorise service agency of OEM ,Make- Kirloskar, including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner and CTC, including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water etc for the following capacities of DG sets all as specified and directed :- (Note spares required for above maint will be measured and paid separately under relevent items of Sch)Location Bihuguri
Supply and fix in replacement of Fuel filter for 320kva DG set,Make : Cummins
Supply and fix in replacement of Fuel filter for 125 kva DG set,Make : Cummins/Kirloskar
Supply and fix in replacement of Fuel filter for 200kva DG set,Make : Greaves cotton ltd
Supply and fix in replacement of Fuel filter for 140kva DG set,Make : Kirloskar
Supply and fix in replacement of Fuel filter for 100 kva DG set,Make : Kirloskar
.Supply and fix in replacement of Fuel filter for 62.5 kva DG set,Make : Kirloskar
.Supply and fix in replacement of Fuel filter for 30 kva DG set,Make : Kirloskar
Supply and fix in replacement of Fuel filter for 40 kva DG set,Make : Kirloskar
Supply and fix in replacement of Diesel filter for 320 kva DG set,Make : Cummins
Supply and fix in replacement of Diesel filterfor 125 kva DG set,Make : Cummins/Kirloskar
Supply and fix in replacement of Diesel filtre for 200 kva DG set,Make : Greaves cotton ltd
Supply and fix in replacement of Diesel filter for 140 kva DG set,Make : Kirloskar
Supply and fix in replacement of Diesel filter for 100 kva DG set,Make : Kirloskar
Supply and fix in replacement of Diesel filter for 62.5 kva DG set,Make : Kirloskar
Supply and fix in replacement of Diesel filter for 30 kva DG set,Make : Kirloskar
Supply and fix in replacement of Diesel filter for 40 kva DG set,Make : Kirloskar
Supply and fix in replacement of Air cleaner filter for 320 kva DG set,Make : Cummins
Supply and fix in replacement of Aircleaner filter for 125 kva DG set,Make : Cummins/Kirloskar
Supply and fix in replacement of aircleaner filter for 140 kva DG set,Make :Kirloskar
Supply and fix in replacement of Aircleaner filter for 100 kva DG set,Make : Kirloskar
Supply and fix in replacement of aircleaner filter for 62.5 kva DG set,Make : Kirloskar
Supply and fix in replacement of aircleaner filter for 30 kva DG set,Make : Kirloskar
Supply and fix in replacement of aircleaner filter for 40 kva DG set,Make : Kirloskar
Supply and fix in replacement of Fan belt for 320 kva DG set,Make : MRF/Dunlop
Supply and fix in replacement of Fan belt for 125 kva DG set,Make : MRF/Dunlop
Supply and fix in replacement of Fan belt for 200 kva DG set,Make : MRF/Dunlop
Supply and fix in replacement of Fan belt for 140 kva DG set,Make :MRF/Dunlop
Supply and fix in replacement of Fan belt for 100 kva DG set,Make : MRF/Dunlop
Supply and fix in replacement of Fan belt for 62.5 kva DG set,Make : MRF/Dunlop
Supply and fix in replacement of Fan belt for 30 kva DG set,Make : MRF/Dunlop
Supply and fix in replacement of Fan belt for 40 kva DG set,Make : MRF/Dunlop
Supply and fix in replacement of Disply control Panel (LED Board) Part no-0300-6088 for 320kva DG set,Make : Cummins
Supply and fix in replacement of Fuel actuator with O Ring Part no-3330601 for 320kva DG set,Make : Cummins
Supply and fix in replacement of Water Separator filter for 320kva DG set,Make : Cummins
Supply and fix in replacement of Key switch Part no-504975 for 320kva DG set,Make : Cummins
Supply and fix in replacement of coolant temperature sensor Part no3865346 for 320kva DG set,Make : Cummins
Supply and fix in replacement of Fuel NRV for 320kva DG set,Make : Cummins
Supply and fix in replacement of Lube oil pressure sensor adaptor Part no-3814448 for 320kva DG set,Make : Cummins
Supply and fix in replacement of SD coil for 320kva DG set,Make : Cummins
Supply and fix in replacement of Actuator for 320kva DG set,Make : Cummins
Supply and fix in replacement of Solenoid Switch for 320 kva 24 Volt DG set,Make : Cummins
Supply and fix in replacement of Harness (Engine) wiring for 320kva DG set,Make : Cummins
M&L for top overhulling of engine 62.5 kva Make:- kirloskar with the following details (a) Check cylinder head for valve leakage/grinding,polishioning the same. (b) Decarbonization of combustion chamber,piston ring grooves. (c )S/F the piston ring complete =01set. (d)S/F all joints,gaskets & O rings=01set. (e)S&F thermostate =01no (f) cleaning the cooling system,stainer, diesel tank,engine sump=01job. (g) S&F water pump =01no. (h)S&F Coolent Hose-1set (i)S&F fuel ratio control-01no (j)Calliberation of governor in test bench =01no. (k) Reassemble all parts and testing complite all as directed.
. M&L for top overhulling of engine 140 kva Make:- Kirloskar with the following details (a) Check cylinder head for valve leakage/grinding,polishioning the same. (b) Decarbonization of combustion chamber,piston ring grooves. (c )S/F the piston ring complete =01set. (d)S/F all joints,gaskets & O rings=01set. (e)S&F thermostate =01no (f) cleaning the cooling system,staine r, diesel tank,engine sump=01job. (g) S&F water pump =01no. (h)S&F Coolent Hose-1set (i)S&F fuel ratio control-01no (j)Calliberation of governor in test bench =01no. (k) Reassemble all parts and testing complite all as directed.
M&L for top overhulling of engine 125 kva Make:- Kirloskar.with the following details (a) Check cylinder head for valve leakage/grinding,polishioning the same. (b) Decarbonization of combustion chamber,piston ring grooves. (c )S/F the piston ring complete =01set. (d)S/F all joints,gaskets & O rings=01set. (e)S&F thermostate =01no (f) cleaning the cooling system,stainer, diesel tank,engine sump=01job. (g) S&F water pump =01no. (h)S&F Coolent Hose-1set (i)S&F fuel ratio control-01no (j)Calliberation of governor in test bench =01no. (k) Reassemble all parts and testing complite all as directed.
M&L for top overhulling of engine 320 kva Make:- Cummins .with the following details (a) Check cylinder head for valve leakage/grinding,polishioning the same. (b) Decarbonization of combustion chamber,piston ring grooves. (c )S/F the piston ring complete =01set. (d)S /F all joints,gaskets & O rings=01set. (e)S&F thermostate =01no (f) cleaning the cooling system,stainer, diesel tank,engine sump=01job. (g) S&F water pump =01no. (h)S&F Coolent Hose-1set (i)S&F fuel ratio control-01no (j)Calliberation of governor in test bench =01no. (k) Reassemble all parts and testing complite all as directed.
Taking down and supply and fixing Stop solenoid switch 12Volts
Taking down and supply and Top up Coolent for radiators
Taking down and supply and fixing Oil pressure gauge 62.5 to 125 KVA
Taking down and supply and filling in repacement/topping up engine oil multi grade 15W /40W in engine all as specified and directed. (Make ELF Oil/ Castrol /HP)
Dismentling the top cover of the engine and Taking out defective crank shaft from DG set of 125KVA for checking of clearance grinding polishing and refixing the same in position after complete repair as directed bu Engr-in-charge=01 Job (a)Supply only following spares for 62.5KVA DG set =02 nos. (b)Cylinder liner (3800210000)=01sets. (c)Crank case caps bearing set (4600620000)=01no. (d) Piston ring (F600571000)=4set. (e)Valve guide (3818102000)=12set. (f) Valve sheet insert exhaust (3818103000)=9 no. (g)Valve (3818170000)=12 no. (h)B Kit for RV2 overhauling (3899904000)=01set . (I)Cyl head gasket(F600726000)=1 set. (J) Piston assy complete (2H09910000)=02 no.
Supply & Fix Aluminium Lugs of various sizes (16 sqmm - 400 sqmm ) as per site requirement including taking down old unserviceable lugs complete all as specified and directed.
Calibration of FIP and fuel injector from the authorised dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set up to 125/140KVA (Certificate to this effect that calibration and repair is carried out by authorised delear will be submitted by the contractor) all as specified and directed.
Calibration of FIP and fuel injector from the authorised dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set up to 200/320 KVA(Certificate to this effect that calibration and repair is carried out by authorised delear will be submitted by the contractor) all as specified and directed.
. Disconnecting the electric connection of Alternator of capacity 200/320 KVA DG set ,taking the accumalator and cleaning the core assembly through air blower,heat varnishing with insulating material complete all as directed.(Necessary Spare will be measured and paid in respective items)
Supply and fix in replacement of Disply control Panel (LED Board) Part no-0300-6088 for 125 kva DG set,Make : kirloskar
Supply and fix in replacement of Disply control Panel (LED Board) Part no-0300-6088 for 140 kva DG set,Make : kirloskar
Supply and fix in replacement of field coil assembly for 125/200/320kva DG set,Make : Kirloskar
Supply and fix in replacement of Eye bolt for 125/200/320kva DG set,Make : Kirloskar
Supply and fix in replacement of fan key for125/200/320kva DG set,Make : Kirloskar
Supply and fix in replacement of fan for125/200/320kva DG set,Make : Kirloskar
Supply and fix in replacement of Circlip for125/200/320kva DG set,Make : Kirloskar
Supply and fix in replacement of DE Bearing for125/200/320kva DG set,Make : Kirloskar
Supply and fix in replacement of Brush holder spindle for125/200/320kva DG set,Make : Kirloskar
Supply and fix in replacement of NDE bearing cap for125/200/320kva DG set,Make : Kirloskar
Supply and fix in replacement of Terminal box with LID for125/200/320kva DG set,Make : Kirloskar
Supply and fix in replacement of Slipring assembly for125/200/320 kva DG set,Make : Kirloskar
Supply and fix in replacement of Exicitation (CX) unit for 125/200/320 kva DG set,Make : Kirloskar
M&L for dusting, cleaning, washing using causting soda mixed water and scraping to all old paint to be preparing the surface for new painting after removing all incoming and outgoing electric connections of DG set capacity upto 30 KVA, 62.5 to 140 KVA (40 KVA-02 No, 62.5 KVA - 04 ,125 KVA - 02 Nos, 140 KVA- 01 No, 200 KVA-01) painting using heat resistive paint appllied by spray gun in two coats, over one coat of red oxide primer, complete marking using diffirent colour in standard size of letters and making all connections as per existing complete all as directed by GE. Note :- (i) Colour of paint shall be decided by GE. (ii) DG sets are located at varrious location. (iii) Lower/dark part of surface shall be painting by synthetic enamel paint.
All as per item No 77 above but capacity 320 KVA complete all as directed by GE.
M&l for dismantling/ opening to body parts to be replacing the spaires under overhauling to major parts of DG sets capacity 62.5 to 140 KVA (62.5 -01 ,125 - 02 and 140 KVA- 01 No) inluding re-assembling to all as per exsited after replacing the required spaires complete including testing idel and full load upto satisfiction to accepting authority. Note ;- (i) Required fuel and others shall be provided by deppt. (ii) Quoted rate shall be included Tpt chages site to workshop and back (if required) and other all type of required works at site.
S& F the following spares to inreplacement of DG set capacity 62.5 KVA to 140 KVA all as directed by GE:- (62.5-01, 125- 02 and140 KVA -01 No located A Mess and+ Signal centre+ Zone 3) Note : (i) All spares shall be genuine in origional maufactures all per exisiting. (ii) All spaires shall be supply for different capacity of DG sets. Make Kirloskar/ Cummins (iii) Fixing of spares may be at site or workshop as required.
Lub oil filter element
Fuel filter element primary and Secondary
Element corrosion resister.
Element air cleaner outer
Element air cleaner inner
Element super by pass filter
Hose pipe set of three for cooling system
Lub oil pressure pipe from lub oil pump to filter to lub oil Gallary.
Oil seal for crank shaft ( front and rear)
Gasket for lub oil cooler CLR HSG
O' Ring for lubrication oil cooler
Oil seal for ACC drive
Oil seal 'O' Ring for cummins engine
Hose for Turbo charger
Barrel and plunger injector for cummins engine
Cup injector for cummins engine
Tappet roller for cummins engine
Connector fuel inlet for cummins engine
Connector fuel outlet for cummins engine
Piston
Small end bearing
Intake valve
Exhaust valve
Valve guide
Valve seat
Thrust washer
Oil seal for crank shaft rear
Oil seal for crank shaft front
Injector nozzle
Joint ring crank shaft front
Bush for cam shaft
Hose pipe set with clamp for radiator
Copper washer for injector
Air breather
Rocker cover nut.
Tube assembly fuel return from injection.
Flexible pipe FIP to fuel filter.
Water pumps assembly Make:Meadows /Kirloskar/ cummins /Ruston
Cam shaft
Repair and servicing to self starter of DG set and replacement of spares such as pinion bearing ,connectior ,bushes etc complete all as speciffied.
Cushion/ engine mounting pad
Supply & Fix following spares to inreplacement of DG set of capacity 320 KVA all as directed by GE:- (Located Manekashblock) Note : (i) All spaires shall be genuine in origional maufactures all per exisiting. (ii) All spares shall be supply for different capacity of DG sets. Make Kirloskar/ Cummins
Lub oil filter element
Fuel filter element primary and Secondary
Element corrosion resister.
Element air cleaner outer
Element air cleaner inner
Element super by pass filter
Hose pipe set of three for cooling system
Lub oil pressure pipe from lub oil pump to filter to lub oil Gallary.
Oil seal for crank shaft ( front and rear)
Gasket for lub oil cooler CLR HSG
O' Ring for lubrication oil cooler
Oil seal for ACC drive
Oil seal 'O' Ring for cummins engine
Hose for Turbo charger
Barrel and plunger injector for cummins engine
Cup injector for cummins engine
Tappet roller for cummins engine
Connector fuel inlet for cummins engine
Connector fuel outlet for cummins engine
Main bearing
Piston
Small end bearing
Intake valve
Exhaust valve
Valve guide
Valve seat
Thrust washer
Oil seal for crank shaft rear
Oil seal for crank shaft front
Injector nozzle
Joint ring crank shaft front
Bush for cam shaft
Hose pipe set with clamp for radiator
Copper washer for injector
Air breather
Rocker cover nut.
Tube assembly fuel return from injection.
Flexible pipe FIP to fuel filter.
Piston ring set with oil rings (GOETZE)
Repair / maintenance of radiator by cleaning internally and externally finces using soda water and compresed air and making leak proof by soldering and brazing, including replacement of all the gaskets, damaged copper tubes of suitable size, nuts and bolts etc for 125 to 320 KVA (125 -02 No , 140 KVA - 01 and 320 KVA - 01 No) DG Set all as directed by Engineer in Charge. Note : Quoted rate shall be deemed Tpt chages, de-assembling ,assembling and other work if required. (Location A mess-01 , S/centre- 02 and Main Bldg -01 No)
M&L for rewinding to alternator main stator, exterior rotor and exterior stator capacity 62.5/125 KVA using supper enamelled copper wire in exisiting appropiated gauge complete with insulating matireial, de-assembimg and re-assembling etc incl with following work :- Note:- (i) All essential test as per IS of wounded winding shall be carried out by contractor by authorise authority and two copy of test certificates be submitted to GE for office record. (II) The quoted rate shall be included removing and making all electric and erathing connections ,transpotation charges site to workshop and back , de -assembilng and assembling of items with testing all as per site and directed by GE complete. (iii) DHPP and lubricating oil required for testing will be supplied by the Department. (iv) The rate minor parts such as screw, washer, split ring, circlips and etc shall be deemed to be included in the unit rate. (a) Dismantling of complete alternator parts without damaging any portion and display all dismantled items for inspection by GE to ascertain the extent of repair involved. (b) Taking out old unserviceable burnt copper wire from the main stator, extrior rotor and extrior statater for re-winding using super enamelled copper wire as per existing gauges and turn. (c) Heating varnishing to field coil and armature with super quality varnish and dried out with external heat unit the insulation resistance to required mega Ohms. (d) Cleaning /washing of DE and NDE bearings with connector terminal end. (i) Supply and fix DE & NDE bearing - 02 Nos., Driet - 06 Nos (ii) Supply and fix connector terminal - 01 Nos. (iii) Supply and fix Carbon bush - 12 Nos. and auto cart pannel board timmer -01 No (e) Cleaning and polishing to slip ring assembly and refix the same in position. (f) Checking tension of spring of carbon bush holder and replace with new spring where necessary.(g) Checking all connections for its correctness and reconnect as per the diagram for smooth functioning.(h) Supply and fix of all carbon brushes of slip ring. (j) Assembling the alternator complete as per the existing and complete with engine with proper alignment. (k) Testing of alternator after repair as per direction of Engineer-in-Charge to establish satisfactory repair.
M&L for rewinding to alternator main stator, exterior rotor and exterior stator capacity 320/200 KVA using supper enamelled copper wire in exisiting appropiated gauge complete with insulating matireial, de-assembimg and re-assembling etc incl with following work :- Note:- (i) All essential test as per IS of wounded winding shall be carried out by contractor by authorise authority and two copy of test certificates be submitted to GE for office record. (II) The quoted rate shall be included removing and making all electric and erathing connections ,transpotation charges site to workshop and back , de -assembilng and assembling of items with testing all as per site and directed by GE complete (iii) DHPP and lubricating oil required for testing will be supplied by the Department. (iv) The rate minor parts such as screw, washer, split ring, circlips and etc shall be deemed to be included in the unit rate.(a) Dismantling of complete alternator parts without damaging any portion and display all dismantled items for inspection by GE to ascertain the extent of repair involved. (b) Taking out old unserviceable burnt copper wire from the main stator, extrior rotor and extrior statater for re-winding using super enamelled copper wire as per existing gauges and turn. (c) Heating varnishing to field coil and armature with super quality varnish and dried out with external heat unit the insulation resistance to required mega Ohms. (d) Cleaning /washing of DE and NDE bearings with connector terminal end. (i) Supply and fix DE & NDE bearing - 02 Nos., Driet - 06 Nos (ii) Supply and fix connector terminal - 01 Nos. (iii) Supply and fix Carbon bush - 12 Nos. and auto cart pannel board timmer -01 No (e) Cleaning and polishing to slip ring assembly and refix the same in position. (f) Checking tension of spring of carbon bush holder and replace with new spring where necessary. (g) Checking all connections for its correctness and reconnect as per the diagram for smooth functioning.
Maintanence and serviceining the AMF panel and replace the unserviceable items and testing and replace unserviceable wiring connection in pannel for automatic operation through realy, contactor. timer , sensor etc all as directed.( Unserviceable items will be measured and paid seperately
M&L and fixing to inreplacement of Digital Meter suitable for AMF panel Make:JACKSON
M&L and fixing to inreplacement of Three pole power contractor ,Type -MNX-110 ,Aux contacts 2NO=2NC ,Catno-CS94137 suitable for AMF panel Make:L&T
M&L and fixing to inreplacement of AC control contractor -MO0AC-15 4A at415 volt ,Catno-CS94826suitable for AMF panel Make:L&T
M&L and fixing to inreplacement of DC control contractor -MO0AC-15 4A at415 volt ,Catno-CS94667suitable for AMF panel Make:L&T
Taking down and Supply and fixing steel fabricated battery box made with iron angle 40x40 and size 40cmx30cmx20cm to arrange one 24 volt battery all as directed
Taking down and Supply and fixing Battery lead with terminal made with brass for 12 volt battery
S & F battery including taking down old unserviceable low maintenance Lead Acid type of capacity 12 volts 180 AH including removal of existing unserviceable one and keeping it in self custody which becomes contractors property after the schedule of credit recovery complete all as specified and as directed. make- Exide/ Amaron
S & F battery including taking down old unserviceable low maintenance Lead Acid type of capacity 12 volts 150 AH including removal of existing unserviceable one and keeping it in self custody which becomes contractors property after the schedule of credit recovery complete all as specified and as directed. make- Exide/ Amaron
S & F battery including taking down old unserviceable low maintenance Lead Acid type of capacity 12 volts 120 AH including removal of existing unserviceable one and keeping it in self custody which becomes contractors property after the schedule of credit recovery complete all as specified and as directed. make- Exide/ Amaron
Supply and fix SMPS based battery charger with output of 12V, Voltage step down (230/12 v), current Max 10A and automatic tickle & boost charging of charging voltage 13.6 V - 14.3V, with over and under Voltage protection, Input voltage variation range 170-260V, with charging indication of power ON, Battery Charging and Battery Full including removal of existing unserviceable one complete all as specified and as directed.
Taking down and Supply and fixing heat proof asbestors rope 12mm dia on engine exhaust pipe including dismantling of worn out Asbestors rope and minor welding/tightening in leakage exhaust complete all as directed conforming to ISI specification fire proof/flame proof all as specified and directed.
Preparation of old painted surface of the DG set including radiator, fuel tank etc of the following capacities complete degreasing and spray painting the same with two coats of approved synthetic enamel paint including writing SM/MES nos on DG set size of letter shall be 5CM x 5CM of capacity 62.5/100/125/140 KVA all as directed by Engr-in-charge.
M&L for cleaning external surface with cleaning agent including cleaning of radiator coil with mild acid (or caustic soda) and cleaning of fuel tank etc of the following capacities complete including writing SM/MES nos on DG set size of letter shall be 5CM x 5CM of capacity 200/320 KVA all as directed by Engr-in-charge.
Supply and fix in replacement to self starter 24 volt dc Make : Lucas including takingdown old and unserviceable one
Supply and fix in replacement to PT fuel pump assembly in genuene by origional manufacture all as per existing specification for DG set of capacity 140 KVA (Make : Kirloskar/Cummins)
Supply and fix in replacement to PT fuel pump assembly in genuene by origional manufacture all as per existing specification for DG set of capacity 320 KVA (Make : Cummins)
Supply and fix in replacement of turbo charger kit of capacity 320 KVA and calibrating complete as approved by GE. Make : Cummins)
Supply and fix in replacement of turbo charger kit of capacity 140 KVA and calibrating complete. (Turbo charger Model : HOLSET or as approved by GE) of capacity 140 KVA Make : Kirloskar/Cummins)
Supply and fix in replacement of turbo charger kit of capacity( 125 KVA -02 No and ) capacity DG set complete all as directed by GE. Make;- Meadows/Kirloskar/ cummins/Ruston engine.
Repair and calibration to fuel injection pump incl replacing minor spares such as nut blots ,washer, seal etc all as required for DG set capacity 125 to 140 KVA all as directed by GE. Make;- Meadows/Kirloskar/ cummins/Ruston engine.( 125 KVA - 01 No + 140 KVA -01)
Repair and calibration to fuel injection pump incl replacing minor spares such as nut blots, washer, seal etc all as required complete for DG set capacity 320 KVA all as directed by GE. Make;- Meadows/Kirloskar/ cummins/Ruston engine.
M&L for repair to crank shaft by metal filling ,remantling, grinding, and polishing complete and making true as exisited complete all as directed by GE.
Supply and fix in replacement of oil pump assembly in original all as exsiting suitable for DG set capcity 125 to 140 KVA complete all as directed by GE.
Supply and fix in replacement to of PVC flexible pipe 1/2" dia bore including fixing clamps.
Supply and fix in replacement to brass nipple suitable for fuel line and taking out old one as directed.
Supply and fix in replacement to of Voltage regulator (cutout) 12 Volt for battery charging system. Make : Cummins of equivalent as approved by GE) (Cummins Cat Part No. 0504730).
Supply and fix in replacement to and testing of self starter 12 Volt suitable for 140 KVA DG set complete all as specified and directed.
Supply and fix in replacement to silencer assembly complete with fixing clamp. (Cat Part No. 3229937 & 3812295)
Supply and fix in replacement to ignition on switch with key and other accessories
Supply and fix in replacement to frequency meter 45- to 60 Hz, 440 Volt complete all as specified and directed.
Supply and replacement of rubber coupling including nuts & bolts and connecting plate key of capacity 62.5 to 320 KVA DG set etc complete etc all as in panel board specified & directed. Make :- Meadows/ Kirloskar.
Supply and fix in replacement of 4 Pole Power contractor of AMF control of capacity 415 volts 3 phase 50 Hzs I th 500 A, as per IS 13947 ,IEC 60947-4-1, EN- 60947 compete with testing and comissioning complete all as specified and directed. Make :- Siemens/Schneider/L&T or equivalent as approved by GE
Supply and fix in replacement of 4 Pole Power Contactors - Type MCX of capacity 415 volts 255 A, as per IS 13947 ,IEC -609474 -4-1, EN- 60947-4-1, complete all as specified and directed. Make :- Siemens/Schneider/L&T or equivalent as approved by GE
Supply and fix in replacement of 4 Pole Power Contactors - Type MCX of capacity 415 volts 200 A, as per IS 13947 ,IEC -609474 -4-1, EN- 60947-4-1, complete all as specified and directed. Make :- Siemens/Schneider/L&T or equivalent as approved by GE
Supply and fix in replacement off load change over switch in sheet metal enclosure 4 poles with neutral link , 415 volts, 400 Amps current raiting conforming to IS; 13947 (Part-3): IEC; 60947-3 incl all fixing materriels all as specified and directed by GE.Make :- Siemens/Schneider/L&T or equivalent as approved by GE
Supply and fix in replacement off load change over switch in sheet metal enclosure 4 poles with neutral link , 415 volts, 200 Amps current raiting conforming to IS; 13947 (Part-3): IEC; 60947-3 incl all fixing materriels all as specified and directed by GE. Make :- Siemens/Schneider/L&T or equivalent as approved by GE
Supply and fix in replacement to MCCB ,4 pole, TPN, 415 volts , microprocessor based , rated 250 Amps,having repturing capacity 36 KA - 01 No as incomer Complete all as specified and as directed.
Supply and fix in replacement to MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 160 Amps,having repturing capacity 25 KA - 01 No as incomer Complete all as specified and as directed.
Supply and fix in replacement to MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 125 Amps,having repturing capacity 25 KA - 01 No as incomer Complete all as specified and as directed.
Supply and fix in replacement to MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 63 Amps,having repturing capacity 16 KA - 01 No as incomer Complete all as specified and as directed.
Supply and fix in replacement to MCBs , 240 Volts grade , SPN, single pole and neutral link ,"C" curve , 63 Amps Complete all as specified and as directed.
M&L for repair and repalacing the door hinges of panel/ feeder piller boxes incl cutting/ welding /painting etc all as site required to be making serviceable as per existing and directed by GE.
Supply only distil (deminralished) water use in battery in a sealed container ISI marked complete Note: Make shall be approved by accepting officer.
Maint and servicing of DG set 400 KVA conopy type with AMF Panel , in through authorise service agency of OEM ,Make- Cummins, including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of POL tank and radiator etc all as specified and directed. Note:- spares required for above maint will be measured and paid separately under relevent items of Schedule
Maint and servicing of DG set 250 KVA conopy type in through authorise service agency of OEM ,MakeGREAVS COTTON Ltd, including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner and CTC, including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water etc for the following capacities of DG sets all as specified and directed. Note:- spares required for above maint will be measured and paid separately under relevent items of Schedule
Maint and servicing of DG set 160 KVA conopy type in through authorise service agency of OEM ,MakeGREAVS COTTON Ltd, including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner and CTC, including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water etc for the following capacities of DG sets all as specified and directed. Note:- spares required for above maint will be measured and paid separately under relevent items of Schedule. Note:- spares required for above maint will be measured and paid separately under relevent items of Schedule Location:- Gajraj Auditorium
Maint and servicing of DG set 75 KVA conopy type through authorise service agency of OEM ,Make- Kirloskar, including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner and CTC, including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water etc for the following capacities of DG sets all as specified and directed. Note:- spares required for above maint will be measured and paid separately under relevent items of Schedule
Supply only Fuel filter for 400 KVA DG set, Make : As per OEM.
Supply only Fuel filter for 250 KVA DG set,Make : Greaves cotton ltd or as approved by GE.
Supply only Fuel filter for 160 KVA DG set,Make : Greaves cotton ltd or as approved by GE.
Supply only Fuel filter for 75 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only Lub oil filter for 400 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only Lub oil filter for 320 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only Lub oil filter for 250 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only Lub oil filter for 160 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only Lub oil filter for 125 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only Lub oil filter for 100 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only Lub oil filter for 75 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only Lub oil filter for 62.5 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only Air cleaner filter (inner and outer ) for 400 KVA DG set, Make : Cummins or as approved by GE.
Supply only Air cleaner filter (inner and outer ) for 250 KVA DG set, Make : Greaves cotton ltd or as approved by GE.
Supply only Air cleaner filter(inner and outer) for 160 KVA DG set, Make : Greaves cotton ltd or as approved by GE.
Supply only Air cleaner filter(inner and outer ) for 75 KVA DG set, Make : Kirloskar or as approved by GE.
Supply only Fan belt for 400 KVA DG set, Make :JK/Dunlop or as approved by GE.
Supply only Fan belt for 250 KVA DG set, Make : JK/Dunlop or as approved by GE.
Supply only Fan belt for 160 KVA DG set, Make : JK/Dunlop or as approved by GE.
Supply only Fan belt for 75 KVA DG set, Make : JK/Dunlop or as approved by GE.
M&L for top overhulling of engine 320 KVA Make:- Cummins.with the following Spare Parts:- (a) Seal O ring - 02 Nos (b) Core Cooler - 01 No (c) Kit-Barrel Plunger & Cap - 06 (d) Head, Cylinder - 01 Nos (e) Gasket Oil Pan - 01 No (f) Gasket Turbo Charger - 01 No (g) Clamp -T bolt - 02 Nos (h) Belt V-Ribbed (h) Hose, Plain - 04 Nos (j) Seal triangular ring - 03 Nos (k) Screen - 01 No (l) Thermostat - 01 No (m) Clamp, Hose - 04 Nos (n) Seal O ring - 01 No (o) Kit, Seal - 01 No (p) Upper engine gasket set - 01 No (q) Gasket Governor set - 01 No (r) Bearing, ball - 01 No (s) Seal 'O' ring (40169330) - 18 (t) Diaphragm, Fuel pump damper - 01 No (u) Washer sealing - 01 No (v) Gasket, oil suc connection - 03 Nos (w) Ball check - 06 Nos (x) Shaft fuel pump drive - 01 No (y) Shaft Techometer drive - 01 No (z) Bearing connecting rod - 12 Nos (z) Crank Shaft bearings (aa) Spring compression - 01 No (ab) Gasket, fuel pump - 01 No (ac) Screen filter - 06 Nos (ad) Ring liner seal - 06 Nos (ae) Plug injector orifice - 06 Nos (af) Spider jaw coupling - 01 No (ag) Hub, Jaw coupling - 01 No (ah) Key square - 01 No (ai) Retainer screen - 06 Nos (aj) Kit Piston and ring set - 01 No (ak) Kit Cylinder head NTBC repair - 02 No (al) Governor Barrel & Plunger - 01 No (am) Kit, Turbo repair HT 4B - 01 No (an) Liner, Cylinder - 01 No (ao) Rod Push - 18 Nos (ap) Screw cross head Adjusting - 12 Nos (aq) Nut, heavy Hexagonal - 12 Nos (ar) Delivery charges - LS (as) Service charges - LS (at) Reassemble all parts and testing complete all as directed.
M&L for top overhulling of engine 100/160 kva Make:- Kirloskar.with the following details (a) Check cylinder head for valve leakage/grinding,polishioning the same. (b) Decarbonization of combustion chamber,piston ring grooves. (c ) S&F the piston ring complete =01set.(d) S&F all joints,gaskets & O rings=01set. (e) S&F thermostate =01no (f) cleaning the cooling system,stainer, diesel tank,engine sump=01job. (g) S&F water pump =01no. (h) S&F Coolent Hose-1set (i) S&F fuel ratio control-01no (j) Calliberation of governor in test bench =01no. (k) Reassemble all parts and testing complite all as directed.
Calibration of FIP and fuel injector from the authorised dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set up to 75/100 KVA (Certificate to this effect that calibration and repair is carried out by authorised delear will be submitted by the contractor) all as specified and directed.
Calibration of FIP and fuel injector from the authorised dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set up to 125/160KVA (Certificate to this effect that calibration and repair is carried out by authorised delear will be submitted by the contractor) all as specified and directed.
Calibration of FIP and fuel injector from the authorised dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set 250/320/400KVA (Certificate to this effect that calibration and repair is carried out by authorised delear will be submitted by the contractor) all as specified and directed.
Disconnecting the electric connection of Alternator of capacity 250/320/400 KVA DG set ,taking the accumalator and cleaning the core assembly through air blower,heat varnishing with insulating material complete all as directed.
Disconnecting the electric connection of Alternator of capacity125/160 KVA DG set ,taking the accumalator and cleaning the core assembly through air blower,heat varnishing with insulating material complete all as directed.
Disconnecting the electric connection of Alternator of capacity 62.5/75/100 KVA DG set ,taking the accumalator and cleaning the core assembly through air blower,heat varnishing with insulating material complete all as directed.
Supply only in replacement of field coil assembly for 125/100/75/62.5kva DG set,Make : Kirloskar or as approved by GE.
Supply only in replacement of Eye bolt for125/100/75/62.5 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only in replacement of fan key for125/75/62.5 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only in replacement of fan assembly for125/100/75/62.5 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only in replacement of fan for125/100/75/62.5 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only in replacement of Circlip for125/100/75/62.5 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only in replacement of DE Bearing for125/100/75/62.5 KVA DG set,Make : Kirloskar or as approved by GE.
Supply only in replacement of Brush holder spindle for125/100/75/62.5kva DG set,Make : Kirloskar or as approved by GE.
Supply only in replacement of NDE bearing cap for125/100/75/62.5kva DG set,Make : Kirloskar or as approved by GE.
Supply only in replacement of Slipring assembly for125/100/75/62.5kva DG set,Make : Kirloskar or as approved by GE.
Supply only in replacement of Exicitation (CX) unit for 125/100/75/62.5kva DG set, Make : Kirloskar or as approved by GE.
Supply only in replacement of Slipring assembly for 160/250kva DG set,Make : Greaves cotton ltd or as approved by GE.
Supply only in replacement of Exicitation (CX) unit for160/250kva DG set,Make : Greaves cotton ltd or as approved by GE.
Supply only in replacement of Exicitation (CX) unit for 320kva DG set,Make Cummins or as approved by GE.
Supply only in replacement of Slipring assembly for 320kva DG set,Make Cummins or as approved by GE.
Supply only in replacement of Exicitation (CX) unit for 400kva DG set,Make Cummins or as approved by GE.
Taking down and Supply and fixing Battery terminal made with brass for 24 volt battery
Preparation of old painted surface of the DG Set Canopy, DG set including radiator Fuel tank etc of the following capacities complete degreasing and spray painting the same with two coats of approved synthetic enamel paint including writing SM/MES nos on DG set size of letter shall be 5 CM x 5CM of capacity 62.5/75/100/125/160 KVA all as directed by Engr in Charge.
Material and labour for cleaning external surface with cleaning agent including cleaning of radiators coil with with mild acid (or caustic soda) and cleaning of fuel tank etc of the following capacities complete including writing SM/MES nos on DG set size of letter not less than 50mm x 50mm of capacity 100/125/160/250/320/400 KVA all as directed.
Taking down and Supply and fixing self starter 12 volt dc Make :- Lucas
Repair, transporting, taking down and servicing of self starter 12/24 volt dc at authorised service centre including refixing the same and testing complete as directed Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose.
M/S N S CONSTRUCTION
Flint India
Iconic Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .