Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹9.3 L+₹75,349 (8.82%)Rejected-Finance GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L2 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹19,120
Closing Date
20 Dec 2021, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne Distt- Pauri Garhwal Pin-246155
SPECIAL REPAIR TO BLDG NO DS-15 AT QL (OR MARRIED ACCN) AT GRRC UNDER AGE (I) LANSDOWNE
2021_MES_484914_2
8659/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I Lansdowne
Class E Cat a i
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹19,120
20 Jan 2022
6 Dec 2021
22 Dec 2021
6 Dec 2021
20 Dec 2021
8 Dec 2021
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating AZ-150 GI based corrugated steel sheet 0.50mm thick of any colour (ISI Marked) having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating AZ-150 GI based plain steel sheet 0.50mm thick (ISI Marked) of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling timber scantling 40 sqcm and over in section,in any position, any description complete all as specified and directed.
M & L for 2nd class softwood in timber scantling for wall panelling, ceiling, roof truss,post, purlins, rafters and similar work (Clean sawn Timber framed and fixed type) including necessary coating framed joints with glue, complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
M & L for 2nd class soft wood boarding 20 mm thick planed one side, rebeted or fixed with screw, fixed to timber frame work with nails complete all as specified and directed. .
S&F in repairs E-boards, ceiling, 4 mm thick with J framed work with main Tee of size 24 x 28.5 mm made out of PGI sheet .3 mm thick double at web and single at flange, flange coverd with powder coated sheet 0.25 mm thick and wall angle 24 x 24 x .45 mm powder coated for ceiling , ceiling boards 60cm x 60cm x 4mm thick , suspended with GI wire 2mm dia and 2m average length with adjustable hanging device complete including plugging in brick/stone walls with steel rawl plug @ 600 mm C/C Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides and making good all the disturbed portion complete all as spd & directed by GE/Eng-in-Charge.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material,outside cantt area distance not exceeding 1.5 KM. complete all as specified and directed.
Material & labour for Rendering 10 mm thick CM 1:6 on brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
M & L for Rendering 15 mm thick in two layers i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Material & labour for Rendering 5 mm thick CM 1:3 using water proofing liquid compound as per manufacturer's instructions on brick or concrete surfaces of ceiling /chajja's finished even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Supply only liquid water proofing compound.ISI marked complete all as specified and directed.
M&L for preparation of new surface of wall and applying two coat of Anti -fungel acrylic emulsion paint Make-Berger (wall masta),or equavlent in Asain or nerolac including one coat of primer complete all as specified by manufacturer and directed by Engineer-in-charge .
M&L for preparation of new surface of wall and applying two coat of Acrylic Emulsion Paint over a coat of primer after applying wall care putty as per manufacturer instructions including preparation of surface , complete all as specified and directed.
M&L for Complete removal of existing treatments by mechanised method from wall by scraping and filling the damage portion with wall putty or cement mortar as required at site and applying two coat of Acrylic Emulsion Paint over a coat of primer after applying wall care putty as per manufacturer instructions including preparation of surface , complete all as specified and directed.
M&L for Preparation of old wooden surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint Ist quality after removal of existing treatment from old surface with help of thiner or other removing chemical materilas complete all as specified and directed.
M & L for preparation of old steel surafces of any description over 10 cm width or girth & applying two caots of synthetic enamel paint Ist quality after removal of old existing treatments with help of thiner or other removing chemical materilas complete all as specified and directed
Dismantling water tanks exc 250 & n exc 500 capacity in litres and removing to store complete all as specified and directed
S&F for Rotational moulded polyethylene water storage tank (ISI Marked only) including, plastic lid cover ( ISI Marked) , triple layered, cylindrical vertical with closed top hoisted and fixed in position of capacity 500 ltrs including making connections,20 mm dia ball valves( ISI Marked heavy duty ) high pressure PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe anf fixed (min wt 210 gram) complete all as specified in SSR Part I.complete all as specified and directed.
Material & Labour for 300x300x 7 to 8mm thick:- Non-Skid light coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.06 Sqm and not exc. 0.11 Sqm, in floor etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 15 mm thick screed bed in cm 1:6 including dismantling of existing old tile. complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I)
Material & Labour for 300X450X 8 to 9 mm thick joint free light coloured glazed ceramic tiles of any design and pattern, as in dado etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 10 mm thick in cm (1:4) backing coat and including dismantling of old tiling and removing old unserviceable materials from the distance not exceeding 1.5 Km complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I) Lansdowne
S&F in repair galvanised mild steel wire cloth ,0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks,or galvanised wire steples complete all as specified and directed.
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sq.m. each pane including hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
S&F in repair bib tap cast copper alloy with crutch or butter fly handle, screwed down for iron pipe 15 mm bore of tubing fancy type cromium plated (ISI Marked). complete all as specified and directed.Make -JaquarEssco Cat No MQT-511KN or equvalent in Gem Cat part No. 12210 Gem and Hindware Cat part No. F200003 ( Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
S&F in repair stop valve cast copper alloy screwed down high presure screwed both end for iron pipe 15 mm dia fancy type cromium plated (ISI Marked). complete all as specified and directed. Make JaquarEssco Cat Par No -MQT-526KN or equvalent in Part No. 12260 (Gem), F110004 (Hindware) Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
Demolition and breaking up 150 mm internal dia drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M&L for 150 mm bore Salt-glazed stoneware drain pipes laid in trenches and jointed as specified SGSW drain pipes laid in trenches complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in concrete bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipes complete all as specified and directed.
Taking up or down steel tubing with connections for cleaning for refixing or removing to storeyard complete of bore 15mm.complete all as specified and directed.
Taking up or down steel tubing with connections for cleaning for refixing or removing to storeyard complete of bore 20mm. complete all as specified and directed.
S& F for GI tubing 15mm bore, medium grade ISI marked with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions, including short lengths etc.) ( heavy grade ISI Marked) , fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and directed.
S& F for GI tubing 20mm bore, medium grade ISI marked with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions, including short lengths etc.) ( heavy grade ISI Marked) , fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and directed.
Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed rigid PVC conduit(ISI marked) ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) including metal flush box made of GI sheet and white cover complete all as specified and directed for the following. One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
S&F for switch piano 230 volts AC flush type, single pole, one way 6 Amps ISI Marked complete all as specified and directed. Make : Anchor/ Cona / Havells
S&F for ceiling rose 3 terminal / PVC/ polycarbonate, isolated body ISI marked all as specified and directed Make : Anchor/ Cona / Havells
S&F for LED tube light batten 20 Watt, 4ft, Polycarbonate housing, translucent diffuser, With LED Light Source, 2200 Lumens, natural White, Surge Protection range- 2KV, Voltage Protection range – 120 -280VAC, 2 years warranty , System efficacy not less than 110Lm/Watt for the fitting, power factor >0.95, total harmonic distortation<20%, Color rendering index >80, Coefficient Colour Temperature – 6500K, Fixed on site with all accessories all as specified & directed. Cat No: SZSLBMX020 of shakti Cat No,C&S LTTB4F20WLEDof C&S LM79 and LM 80 Reports to be produced. BIS Certification must.
S&F for LED Bulb 10 Watt (Cool day light) housing made from polycarbonate, with opaque diffuser, having Colour temp 6500 K and lumen output 950, voltage range 120V-280V AC, power factor >0.9, THD <33% suitable for “B-22 type to fix on batten holder Make : Shakti/Havells/Wipro/C&S.
PIONEER REFRIGERATION AND ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .