| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC 37 SUBHASH NAGAR AIR FORCE JODHPUR 342 008 | JODHPUR | JODHPUR | RAJASTHAN | 342008 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹37.5 L+₹80,719 (2.20%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹37.7 L+₹96,877 (2.64%)Rejected-Finance 00 BAJRANG CHOK MAHOBA MAHOBA UTTAR PRADESH 210427 | MAHOBA | UTTAR PRADESH | 210427 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹39.0 L+₹2.3 L (6.24%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹39.8 L+₹3.1 L (8.32%)Rejected-Finance PANCHAYATI RAJ ROHTAK | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
11 Jan 2020, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur- 342011
ADDITIONAL ALTERATION TO BUILDINGS NO P-284 AND CERTAIN MINOR WORKS INDOOR SPORTS COMPLEX AT DEFENCE LAB JODHPUR
2019_MES_308748_1
8365/E8
Open Tender
Civil Works
Item Rate
270 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹97,000
Yes
12 Sept 2020
23 Dec 2019
13 Jan 2020
23 Dec 2019
11 Jan 2020
1 Jan 2020
24 Dec 2019 - 31 Dec 2019
Amount
M&L squared rubble stone,walling jodhpur type regular courses well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed by Engineer-in-charge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 40mm & dressing face beds and joints as specified to random rubble walling uncoursed or brought up to courses complete all as specified & directed by Engineer-in-charge.
Racking out joints/ pointing to squared rubble masonry built in cement mortar or cement lime mortar, coursed or uncoursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed by Engineer-in-charge.
M&L keyed pointing in cement mortar (1:3) to squraded rubble masonary coursed or un coursed jodhpur type complete all as specified & directed by Engineer-in-charge.
Demolition floor hearth or wall tiling including cement mortar bedding and backing coat and removing unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge.
S&F coloured glazed ceramic tiles size 350x250x7 / 450x350x7/ 450 x 300 x 7mm thick on vertical surface of wall over and including 10mm thick backing coat in CM 1:4 set and jointed in neat cement slurry and pointed in white cement / coloured cement to match the tiles complete all as specified & directed by Engineer-in-Charge
M&L plain cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete all as specified & directed by Engineer-in-charge.
M&L 75 mm thick PCC (1:4:8) type D 2 using 40 mm graded crushed stone aggregate laid in alternative bays as in plinth protection including finishing the surface even & fair & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight all as specified & directed by Engineer-in-Charge
M&L 25mm thick PCC 1:2:4 type B-0 using 12.50 mm graded crushed stone aggregate as in base for screed etc, complete all as specified & directed by Engineer-in-charge.
M&L non skid ceramic coloured tiles of size 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over including screed bed or bedding layer of 15mm thick in CM (1:4) complete all as specified & directed by Engineer-in-charge.
M&L light shade, vitrified tiles, 10mm thick (minimum), (square/ rectangular polished, area of each tiles exceeding 0.36 Sqm (including 600mmx600mm size) but not exceeding 0.42 Sqm, in flooring set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles and over 15mm thick screed bedding in CM 1:4 complete all as directed by Engineer-in-charge.
M&L vitrified tiles of light shade, 10mm thick (minimum) (square/ rectangular) polished area of each tiles equal to or exceeding 0.36 Sqm but not exceeding 0.42 Sqm,cut to size as required in skirting/dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10 mm thick rendering with CM 1:4 complete all as specified and directed by Engineer-in-charge.
M&L 18 to 20mm thick granite stone slab (colour as approved by AGE(I)) table rubbed and polished as in flooring, cooking platform,window cill,pillers,steps etc including rounding to edge of granite slab as required pointing with white cement (1:2) using marble dust with admixture of pigment to match with colour of granite slab over 15mm thick screed bed/backing coat in CM (1:4) complete all as specified and directed by Engineer-in-charge.
M&L 18 to 20mm thick granite stone slab (colour as approved by AGE(I)) table rubbed and polished as inwall lining (veneering to wall) 12mm thick in cement mortar(1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with colour of granite slab complete all as specified and directed by Engineer-in-charge.
M&L machine cut kota stone slab flooring 20 to 25mm thick laid over cement screed base and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15 mm thick backing coat in CM (1:4) complete all as directed by Engineer-in-charge.
M&L machine cut kota stone slab 18 to 20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15 mm thick backing coat in CM (1:4) complete all as directed by Engineer-in-charge.
M&L Udaipur green marble stone slabs 15 to 20 mm thick as in floors,steps,etc including rounding to edge of marble slab as required pointing with white cement (1:2) using marble dust with admixture of pigment to match with colour of marble slab over 10mm thick screed bed/backing coat in CM (1:4) complete all as specified and directed by Engineer-in-charge.
M&L 40mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in floors & fixing of glass dividing strips & finishing the surface even & smooth with using extra cement all as specified & directed by Engineer-in-charge.
Supply only 38mm wide and 3mm thick glass dividing strip complete all as specified & directed by Engineer-in-charge.
M&L 4.00 mm thick PVC tiles/sheets,laminated plain coloured,marble mosaaic or mottled finish,laid with approved rubber based adhesive in floors complete all as specified and directed by Engineer-in-charge.
M&L treating of soil underexisting floors using emulsion @ one litre per hole,300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors complete all as specified and directed by Engineer-in-charge.
M&L treating at points og contact of wood work by chemical emulsion (in oil or kerosene based solution @ 0.50 litre/ hole by drilling 6mm dia holes at adownward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed by Engineer-in-charge.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed by Engineer-in-charge.
M&L 15 mm thick , plaster in cement mortar (1:4) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L 15 mm thick , plaster in cement mortar (1:4) on brick masonry wall surfaces and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L preparing new plastered surfaces of walls and applying two coats of acrylic weather coats exterior grade paint over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L preparing old decorated surfaces of stone walls by complete removal of existing treatment and applying two coats of acrylic weather coats exterior grade paint over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L preparing old decorated surfaces of stone walls (RCC projected beam/slabs/chajjas etc by complete removal of existing treatment and applying two coats of acrylic weather coats exterior grade paint over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L 15 mm thick , plaster in cement mortar (1:6) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L preparing new plastered surface of wall and applying 2 to3 mm thick birla white wall care putty complete all as specified & directed by Engineer-in-Charge.
M&L two coats of oil bound distemper of approved tint over and including a coat of primer on putty finished wall surface complete all as specified & directed by Engineer-in-Charge.
M&L two coats of oil bound distemper of approved tint over and including a coat of primer on newly plastered surface of walls complete all as specified & directed by Engineer-in-Charge.
M&L preparing old plastered surface of wall by removing complete removal of existing treatment and applying 2 to3 mm thick birla white wall care putty complete all as specified & directed by Engineer-in-Charge.
M&L preparing old plastered surface of ceiling by removing complete removal of existing treatment and applying 2 to3 mm thick birla white wall care putty complete all as specified & directed by Engineer-in-Charge.
M&L two coats of oil bound distemper of approved tint over and including a coat of primer on putty finished ceiling surface complete all as specified & directed by Engineer-in-Charge.
M&L antiskid organic paint on old wooden floors of badminton court including cleaning and preparing the surfaces as per manufacturers instructions complete all as specified & directed by Engineer-in-charge.
S&F rolled mild steel sections like angle, channel, flat etc as inframed work such as grills,gratings,etc,with ends of bars shouldered and/or riveted,or forged into spikes, framed guard bars;barred iron doors;ladders ;framed balusters;walk ways; railings;framedwork of water tanks,hold fast,wall ties andsimilar work confirming toFe-290Gde E-165 complete all as specified & directed by Engineer-in-charge.
Taking down collapsible steel gate of area not exceeding 15 sqm and refixing after repairing like remove band,welding,change of rollers etc complete all as specified & directed by Engineer-in-charge.
M&L preparation of new or previously untreated steel surfaces of any description over 10cm width or girth not otherwise described and apply two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified & directed by Engineer-in-charge.
M&L preparation of old steel surface of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified & directed by Engineer-in -charge.
S&F Collapsible steel gates,top hung,consisting of channel pickets,pivoted flat bars,top and bottom runners,brass handles etc., asspecified,erected in position and securing runners with holdfasts and brackets,including taking down old un-serviceable collapsible steel gate complete all as directed by Engineer-in-charge.
Taking down chowkats or frames (without taking of shutters from the frames) area not exceeding 1.5 Sqm each complete all as specified & directed by Engineer-in-charge.
Taking down chowkats or frames (without taking of shutters from the frames) area exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified & directed by Engineer-in-charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F, solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specifications & directed by Engineer-in-charge.
S&F, 100mm size, butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin,anodised type B-21 including necessary welding if required complete all as specified & directed by Engineer-in-charge.
S&F 150 mm size aluminium anodised barrel tower bolts of extruded section complete all as specified & directed by Engineer-in-charge.
S&F 150 mm size aluminium handle, cast type, anodiesed complete all as specified & directed by Engineer-in-charge.
S&F Anodised aluminium frame for doors,windows,ventilators,partition wall etc with one or more rebated including jointing cleat for fixing etc complete all as specified and directed by Engineer-in-charge.
S&F anodised aluminium(powder coating of any colour) door shutters,aluminium section weight 1.00 to 1.8 kg/m including necessary jointing cleats,glazing clips,rubber neoprene packing,handles 2 Nos in each door,hinges,anodised aluminium snap beading screws etc complete all as specified & directed by Engineer-in-charge.(thickness of powder coating not less than 50 micron) (Note :- Floor door spring & sheet glass shall be measured and paid seperately).
S&F anodised aluminium(powder coating of any colour) window and ventilator shutters,fixed type without sash bar,aluminium section weighting 1.00 to1.80 kg/m including necessary jointing cleats,glazing clips,rubber packing,anodised aluminium snap beading,screws etc complete all as specified & directed by Engineer-in-charge.(thickness of powder coating not less than 50 micron) (Note :- Floor door spring & sheet glass shall be measured and paid seperately).
S&F anodised aluminium(powder coating of any colour) window and ventilator shutters,side hung type without sash bar,aluminium section weighting 1.00 to1.80 kg/m including necessary jointing cleats,glazing clips,rubber packing,anodised aluminium snap beading,screws etc anodised aluminium fittings hinges (type B-21) 100 mm long (02 Nos) tower bolt 100 mm long (02 Nos) and handle 100 mm long (01Nos) on each shutters, complete all as specified & directed by Engineer-in-charge.(thickness of powder coating not less than 50 micron) (Note :- Floor door spring & sheet glass shall be measured and paid seperately).
S&F Anodised aluminium grill (powder coating any colour) 6mm aluminium section having square gap of 50 mm with U clip (weight not less than 0.50Kg per sqm) complete all as specified and directed by Engineer-in-charge. (Deco grill or equivalent, thickness of powder coating not less than 50 micron)
S&F 12 mm thick prelaminated particle board/ MDF board exterior grade, prelaminated both side with decorative choice lamination fixed with screws to timber frame work/aluminium frame complete as specified and directed by Engineer-in-charge.
S&F 100 mm size 4 Levers, bress mortice Lock, vertical type complete all as specified & directed by Engineer-in-charge.
S&F140mm Floor door stopper of aluminium alloy body and tongue,anodised,with hard drawn steel spring,fixed in floor complete all as specified & directed by Engineer-in-charge.
S&F, Aluminium(Die cast)body Door closer hydraulically regulated,designation No3,universal type,suitable for shutters of 851 to 1000 mm in width and of weight between 61to 80 Kg complete all as specified & directed by Engineer-in-charge.
M&L Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box,main body with stainless steel cover,governing pivot made of brass,other parts made of mild steel heavy duty and making good to floor to match with existing floor complete all as specified and directed by Engineer-in-charge.
S&F 4.80 mm thick frosted sheet glass, ordinary quality and glazing in squares area not exceeding 0.5 Sqm in each pane complete all as specified & directed by Engineer-in-charge.
S&F 4.80 mm thick sheet glass, ordinary quality and glazing in squares area exceeding 0.5 Sqm in each pane complete all as specified & directed by Engineer-in-charge.
S&F 5.50 mm thick tinted sheet glass, ordinary quality and glazing in squares area exceeding 0.5 Sqm in each pane complete all as specified & directed by Engineer-in-charge.
S&F Solar control film 50 micron reflective type (graveware sun control or equivalent) complete all as specified & directed by Engineer-in-charge.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 and fixed with stainless steel wire staples complete all as specified & directed by Engineer-in-charge.
S&F stainless steel framed work for stairs (square,round hollow section of any type etc) including stringers treads,landing,balusters,handrails,cleats,brackets etc complete all as specified and directed by Engineer-in-charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC,PVC or reinforced concrete) of 75mm/110mm bore set in cement mortar complete all as specified and directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors as waste & vent pipes complete all as specified & directed by Engineer-in-charge.
S&F PVC (SWR) bends any radius 110 mm bore with access door complete all as specified & directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors as waste & vent pipes complete all as specified & directed by Engineer-in-charge.
S&F PVC (SWR) bends any radius 75mm bore with access door complete all as specified & directed by Engineer-in-charge.
S&F PVC (SWR) multi floor trap with grating including jointing with solvent cement 75mm complete all as specified & directed by Engineer-in-charge.
M&L 125mm/110mm dia PVC (SWR) gully trap, setting & jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
Taking up or down 15 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-charge.
S&F 15 mm bore galvanised iron tubing ISI Marked 'Medium Grade' with all fittings laid in floors or fixed to wall complete all as specified and directed by Engineer-in-charge.
Fixing only 15 mm bore galvanised iron tubing ISI Marked 'Medium Grade' with all fittings laid in floors or fixed to wall complete all as specified and directed by Engineer-in-charge.
Taking up or down 20 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-charge.
S&F20mm bore galvanised iron tubing ISI Marked 'Medium Grade' with all fittings laid in floors or fixed to wall complete all as specified and directed by Engineer-in-charge.
Fixing only 20 mm bore galvanised iron tubing ISI Marked 'Medium Grade' with all fittings laid in floors or fixed to wall complete all as specified and directed by Engineer-in-charge.
S&F in repairs bib taps, cast copper alloy Chromium Plated, with crutch or butter fly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F 125mm size brass chromium plated shower rose with shower arm of suitable length & bend of 45 degree with flange complete all as specified & directed by Engineer-in-charge.
S&F Brass chromium plated Tubular towel rail 20mm dia,D type, 60 cm long between flanges, complete all as specified & directed by Engineer-in-charge.
S&F stop cock, fancy type,brass chromium plated, with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for 15 mm bore iron pipe or for union complete all as specified & directed by Engineer-in-charge.
S&F in repair vitreous china wash basin white, flat back of size 550 x 400 mm white including waste fittings, brass, chromium plated, coupling, waste pipe, brackets including cutting for and pinning in ends of brackets errect stand, fixing waste pipe complete all as specified & directed by Engineer-in-charge.
S&F PTMT Liquid soap container fixed with brass chromium plated screws (As per sample kept in AGE B/R office) complete all as specified & directed by Engineer-in-charge.
S&F in repairs vitreous china EWC (Excluding flushing cistern and flush pipe) complete all as specified & directed by Engineer-in-charge.
S&F in repairs CP brass water jet spray suitable for EWC complete all as specified & directed by Engineer-in-charge.
S&F, in repair, brass chromium plated angle valve for 15mm bore pipe complete all as specified & directed by Engineer-in-charge.
S&F, in repair, white/ black plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed by Engineer-in-charge.
S&F 15 mm bore brass chromium plated angular stop cock with wall flange(2in1), complete all as specified & directed by Engineer-in-charge.
S&F stainless steel toilet paper with cutting edge cover (As per sample kept in AGE B/R office) complete all as specified and directed by Engineer-in-chage.
S&F stainless steel soap dish of standard size (As per sample kept in AGE B/R office) fixed with chromium plated screws complete all as specified & directed by Engineer-in-charge.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, 10 ltrs capacity, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified & directed by Engineer-in-charge.
S&F in repairs vitreous china urinal,Half stall type,white including cantilever brackets,flush pipe,waste coupling,waste pipe 40mm,spreader etc complete all as specified & directed by Engineer-in-charge.
Dismantling of old un-serviceable PVC/RCC water tank of 500 to 1000 ltrs capacity complete all as specified & directed by Engineer-in-charge.
S&F 1000 ltrs capacity rotational moulded polythene water storage tanks (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete unreinforced inground floors and pavings ,roof padding including roof treatment, granite flooring, tiles flooring and pavings not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge.
M&L 15 mm thick plaster in cement mortar (1:3) with liquid water proofing compound on concrete surfaces of roof and finishing the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L APP based polymeric membrane minimum weighing 3kg / Sqm and minimum 3mm thick reinforced with polyester non woven fabric (weight not less than 150 gms / Sqm) and on primed surface(one coat of approved bituminous [email protected] Ltr per Sqm) by torch application method complete all as specified & directed by Engineer-in-charge.
Supply only liquid water proofing compound ISI Marked complete all as specified & directed by Engineer-in-charge.
S&F CP pillar cock auto closing system with buttom flange of 15mm dia bore for wash hand basin any type screwed down for iron pipe and fixed with cheknut/washers as required complete all as specified & directed by Engineer-in-charge. (Make:Jaquar-Model cat part No-PRS-CHR-031 or equivalent as approved by AGE (I)
S&F CP urinal flush valve (concealed) auto closing system with wall flange of 15mm dia bore for chinaware urinals of any type screwed down/up for iron pipe and fixed in wall including with PVC connection pipe 15X450mm connecting to nozzle of urinal with all necessary accessories complete all as specified & directed by Engineer-in-charge. (Make:Jaquar-Model cat part No-PRS-CHR-073 or equivalent as approved by AGE (I) )
Dismantling wall tiling including cement mortar bedding but not backing and removing rubbish off the premises than Cutting chases in stone/concrete block or slab walls not exc 10cm girth & cutting existing steel tubing for alterations or addition or lengthening pipe to form connector & fixing of concealed CP urinal flush valve 15mm dia bore in stone/concrete walls than rendering 15mm thick with CM(1:4)on fair faces of walls than fixing with new tiles to match with existing tiles in colour & size ,finally making good to disturbed portion of wall tiling complete all as specified and directed by Engineer-in-charge. Note:- 1.Make & size of wall tiles will be incorporated as site per sample approved by Engineer-In-Charge 2.Old u/s CP fittings obtained at site may be handed over/deposit in B&R sub division as directed by Engineer-in-charge.
M&L 5 mm thick plaster in cement mortar (1:3) on concrete surfaces of ceiling and finishing the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
S&F 4.8mm thick Eye glass of size 150X150mm plain sheet glass as in wooden door shutter any type (25 to 40mm thick) including cutting as per required opening, than fixing of glass sheet in shutter with wooden beading and making good to disturbed portion with painting complete all as specified by Engr-in-charge. Note:- Taking down shutter from frames/chowkats complete and refixing or welding in same opening with necessary hardware materials like MS butt hinges/MS screws if required.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified & directed by Engineer-in-chage. (Note:- work should be carried out at above 8.00 to 10.00 mtr height in wksp complex under roof covering/sheets with proper safety precautions as directed by Engineer-in Charge.)
M&L cutting in brick/stone masonary than fixing of window grill in postion & making good to wall surface with plastering ,and applying two coats of OED in disturbed walls complete all as specified and directed by Engineer-in-charge.
M&L Cutting openings through walls for door, windows & other openings or enlarging existing openings, etc in cement mortar or cutting out defective masonry for underpinning including providing, fixing & removing, shoring, cleaning & stacking stone & removing surplus to store & rubbish off the premises in & making good to disturbed portion after completion of each job all as specified & directed by Engineer-in-charge
M&L Plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded stone aggregate) cast in situ in hold fast etc as directed including use and waste of form work complete all as specified and directed by Engineer-in-charge.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc . removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed by Engineer-in-charge.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed by Engineer-in-charge.
Taking down un-serviceable exhaust/ceiling fan of any size and capacity complete all as specified and directed by Engineer-in-charge. (old exhaust fan / ceiling fan shall be deposited in MES store yard)
S&F 450 mm sweep exhaust fan AC single phase 230/240 volts with louver 1400 RPM complete all as specified and directed by Engineer-in-charge. (metal body)
S&F 300 mm sweep exhaust fan AC single phase 230/240 volts with louver 1400 RPM complete all as specified and directed by Engineer-in-charge. (plastic body)
M&L point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including heavy duty PVC concealed conduit with accessories concealed in wall/roof/floor etc, ISI marked with mild steel/prestressed steel sunken/concealed box suitable for modular plate cover (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with modular cover plate for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch One light/fan point / exhaust fan pointcontrolled by one, one way switch 5Amps complete all as specified and directed by Engineer-in-charge.
M&L point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 4 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including heavy duty PVC concealed conduit with accessories concealed in wall/roof/floor etc, ISI marked with mild steel/prestressed steel sunken/concealed box suitable for modular plate cover (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with modular cover plate for fixing of switches socket combination 5/15 Amp inciuding PVC insulated multistranded copper conductor 4 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge.
M&L Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc including taking out old un-serviceable earthing, complete all as directed by Engineer-in-charge. Note: (i) The concrete pit shall be PCC 1:3:6 type C-1, 40mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate, reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No. 3 of MES SSR Part-I., (ii) Item includes the cost of GI pipe up to 7.5m GI for protection of earth lead & (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Taking down unserviceable sub main wiring with copper/aluminium conductor,PVC insulated,unsheathed cable of any size drawn through rigid PVC/Steel conduit or PVC casing coping including earth wire complete all as specified and directed by engineer-in-charge.
M&L Wiring for circuit / submain wiring in suitable size of rigid non-metallic PVC concealed conduit alongwith 6.00 Sqmm earth wire with 4 x 6.00 Sqmm FRLS PVC insulated multi-stranded copper conductor, single core cable complete all as specified and directed by engineer-in-charge.
M&L Wiring for circuit / submain wiring in suitable size of rigid non-metallic PVC concealed conduit alongwith 6.00 Sqmm earth wire with 2 x 6.00 Sqmm FRLS PVC insulated multi-stranded copper conductor, single core cable complete all as specified and directed by engineer-in-charge.
M&L Wiring for circuit / submain wiring in suitable size of rigid non-metallic PVC concealed conduit alongwith 10.00 Sqmm earth wire with 4 x 10.00 Sqmm FRLS PVC insulated multi-stranded copper conductor, single core cable complete all as specified and directed by engineer-in-charge.
M&L Wiring for circuit / submain wiring in suitable size of rigid non-metallic PVC concealed conduit alongwith 4.00 Sqmm earth wire with 2 x 4.00 Sqmm FRLS PVC insulated multi-stranded copper conductor, single core cable complete all as specified and directed by engineer-in-charge.
M&L PVC insulated triple core 1.50 sqmm FRLS conductor multistrand for connection for security light from DB box to security lights/OH conductor to security light complete all as specified and directed by engineer-in-charge.
S&F 25 sqmm 3.5 core XLPE LT insulated armoured heavy duty electric cable with aluminium conductor light complete all as specified and directed by engineer-in-charge.
S&F 32 mm dia rigid non-metallic PVC conduit exclusive of boxes (junction / terminal) but inclusive of all tees,bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe hooks etc complete all as specified and directed by engineer-in-charge.
S&F modular switch piano 6 Amp flush type single pole one way with ISI marked,complete all as specified and directed by engineer-in-charge.
S&F MCB SP ‘C’ Curve 10KA : 6 to 32 amps in DB complete all as specified and directed by Engineer-in-charge.
M&L MCB DB SPN 8 way double door concealed in wall IP 43 protection with 200 Amps rated bus bar for housing MCBs complete all as specified and directed by Engineer-in-charge.
S&F MCB SPN ‘C’ Curve 10KA : 40 amps in DB complete all as specified and directed by Engineer-in-charge.
S&Fmodular switch piano 16 Amp flush type single pole one way with ISI marked,complete all as specified and directed by Engineer-in-Charge.
S&F modular Socket out let flush type universal type 6 pin 6/16 Amps , ISI marked,complete all as specified and directed by Engineer-in-Charge.
S&F two pin earth plug socket with one MCB SP "C" curve 10KA 32 Amps with enclosure complete all as specified and directed by Engineer-in-Charge.
S&F three pin earth plug socket with one MCB TPN 415 V "C" curve 10KA 63 Amps with enclosure complete all as specified and directed by Engineer-in-charge.
M&L MCB DB TPN 4 way double door concealed in wall IP 43 protection with 200 Amps rated bus bar for housing MCBs complete all as specified and directed by Engineer-in-charge.
S&F MCB TPN 415 V ‘C’ Curve 10KA : 63 amps in DB complete all as specified and directed by Engineer-in-charge.
S&F MCB TPN 415 V ‘C’ Curve 10KA : 40 amps in DB complete all as specified and directed by Engineer-in-charge.
S&F modular white cover plate with frame, 4 module complete all as specified and directed by Engineer-in-charge.
S&F modular white cover plate with frame, 2 module complete all as specified and directed by Engineer-in-charge.
S&F lamp holder PVC/ Polycarbonite type complete all as specified and directed by Engineer-in-charge.
Fabrication and fixing 1.20 m long,40 mm bore GI tubing medium grade, bended to shape required as in brackets for fixing street/security/sports light with 02 Nos 40mm wide 4 mm thick clamps with nuts,bolt and washers rated complete all as specified and directed by Engineer-in-charge.
S&F surface and wall mounted LED lumiline batten with polycabonate housing & integrated electronic driver 22 W complete all as specified and directed by Engineer-in-charge.
S&F2x2 environmental friendly,new reneration,aesthetically designed,ultra modern recess mounting luminaire with high brightness SMD 36 Watt LEDs as light source suitable for Armstrong /grid ceiling complete all as specified and directed by Engineer-in-charge.
S&F 5/6 watt LED bulb complete all as specified and directed by engineer- in-charge.
Taking down old/unserviceable under ground LT cable of any cross-sectional area from trenches/walls/poles after dis-connecting connections complete all as specified and directed by Engineer-in-charge.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor,cross-sectional area50sq.mm 3 1/2core complete all as directed by Engineer-in-charge.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor,cross-sectional area 25sq.mm 3 1/2core complete all as directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed by Engineer-in-charge.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer-in-charge.
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and n. exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
M&L sand cushioning to undergound cable with using tibba sand and gently punning for cushioning to cable complete all as specified and as directed by Engineer-in-charge. Note: for the purpose of payment only punned thickness will be measured.
M&L plain cement concrete (1:3:6) type C-1 using 20 mm graded crushed stone aggregate as in foundations, filling & mass concrete complete all as specified & directed by Engineer-in-Charge.
S&F Turbo LED flood light 200 Watt with secondary optics with innovative thermal management with multiple optics and equipped with IP-66 protection complete all as specified & directed by Engineer-in-Charge. (CAT REF :-LSFO-200-CDL/60 of CG or equivalent as approved by AGE(I).
S&F 400 Watt LED Flood light Unique Modular Design and Scalable solution with IP66 protection ideal for stadium lighting and Highmask application complete all as specified & directed by Engineer-in-Charge. (CAT REF :-LFLPL-400-CDL/60 of CG or equivalent as approved by AGE(I).
S&F 72 Watt LED street light Aesthetically designed roadway luminiare with excellent thermal management with IP66 protection and GI bracket of 32 mm bore medium grade pipe of 1.20 mtr long with suitable size clamps,nuts and bolts complete all as specified & directed by Engineer-in-Charge. (CAT REF :-LSTP-72-CDL of CG or equivalent as approved by AGE(I).
S&F Steel tubular swaged poles,complete with cast iron base plate,finial taper plug,bolts,nuts & screws as specified type 410 SP-64 (12.00 metres long) complete all as specified & directed by Engineer-in-Charge.
S&F Ceiling rose, 3 phase / PVC / Polycarbonate, isolated bodycomplete all as specified and directed by engineer-in-charge.
SHOBHIT BUILDERS
HINDUSTAN TRADING COMPANY
SHRI BHIKSHU ART AND CONSTRUCTION CO
HOODA CONSTRUCTION COMPANY
vinayandsons
M/S Dharam Chand Lal Chand Jain
Nikhat nirman
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .