| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 6 VANARAI SHOPPING COMPLEX W E HIGHWAY GOREGAON E MUMBAI 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | L1 | Accepted-AOC Successful Lowest (L1) Bidder | |
| 2 | L2₹25.7 L+₹7.8 L (43.7%)Rejected-AOC | L2 | Rejected-AOC Unsuccessful Bidder | |
| 3 | L3₹26.0 L+₹8.1 L (45.3%)Rejected-AOC 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L3 | Rejected-AOC Unsuccessful Bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Not meeting NIT criteria. | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹26.9 L
EMD Value
₹53,792
Closing Date
4 Jul 2020, 6:00 pmClosed
Asstt.General Manager (Engg.-Elect.)
Airports Authority of India, Room No. 202/15, ATS Complex, Sutar Pakhadi Road, Andheri (East), Mumbai - 400 099
Annual Maintenance Contract of HT installations at ATS Complex and Operational Area, Mumbai Airport, Mumbai for the year 2020-21 to 2021-22
2020_AAI_51213_1
MUM/ATS/ENGG-E/eNIT-01/2020-21
Open Tender
AMC/ Maintenance Contracts
Item Rate
730 days
ATS Complex and Operational Area of C.S.M.I.A.
Tender fee, EMD, MSME Regn. along with Decl.for exemption of Tender Fee and EMD,Unconditional Accept. Ltr. and Balance Documents as per PQ Performa
6 documents required · 6 mandatory
₹1,120
Yes
Airports Authority of India
₹53,792
Yes
21 Aug 2020
23 Jun 2020
10 Jul 2020
24 Jun 2020
4 Jul 2020
24 Jun 2020
24 Jun 2020 - 29 Jun 2020
Amount
Filtration and dehydration of oil for the following installations including testing of the Oil for dielectric strength before and after filtration as per IS: Specification and submission of of the report of B.D.V. Test and Chemical analysis of the oil to determine the level of acidity as per IS: Specification and cleaning of breather and providing fresh charges of Silica Gel to the transformers, Supplying and replacing corroded nuts and bolts, gaskets and washers, etc. (Transformers oil for topping up will be supplied separately.) a) First year i) Transformer 11 KV/ 433 Volts, 2 MVA
Filtration and dehydration of oil for the following installations including testing of the Oil for dielectric strength before and after filtration as per IS: Specification and submission of of the report of B.D.V. Test and Chemical analysis of the oil to determine the level of acidity as per IS: Specification and cleaning of breather and providing fresh charges of Silica Gel to the transformers, Supplying and replacing corroded nuts and bolts, gaskets and washers, etc. (Transformers oil for topping up will be supplied separately.) a) First year ii) Transformer 3.3 KV/ 433 Volts, 250 KVA
Filtration and dehydration of oil for the following installations including testing of the Oil for dielectric strength before and after filtration as per IS: Specification and submission of of the report of B.D.V. Test and Chemical analysis of the oil to determine the level of acidity as per IS: Specification and cleaning of breather and providing fresh charges of Silica Gel to the transformers, Supplying and replacing corroded nuts and bolts, gaskets and washers, etc. (Transformers oil for topping up will be supplied separately.) a) First year iii) Transformer 3.3 KV/ 433 Volts, 100 KVA
Filtration and dehydration of oil for the following installations including testing of the Oil for dielectric strength before and after filtration as per IS: Specification and submission of of the report of B.D.V. Test and Chemical analysis of the oil to determine the level of acidity as per IS: Specification and cleaning of breather and providing fresh charges of Silica Gel to the transformers, Supplying and replacing corroded nuts and bolts, gaskets and washers, etc. (Transformers oil for topping up will be supplied separately.) a) First year iv) 3.3 KV HT extensible oil switch fuse unit/ Isolator
Filtration and dehydration of oil for the following installations including testing of the Oil for dielectric strength before and after filtration as per IS: Specification and submission of of the report of B.D.V. Test and Chemical analysis of the oil to determine the level of acidity as per IS: Specification and cleaning of breather and providing fresh charges of Silica Gel to the transformers, Supplying and replacing corroded nuts and bolts, gaskets and washers, etc. (Transformers oil for topping up will be supplied separately.) a) First year v) 3.3 KV, Oil immersed Ring Main Units of 200 -400 Amps. capacity consisting of one incomer and two outgoings.
Filtration and dehydration of oil for the following installations including testing of the Oil for dielectric strength before and after filtration as per IS: Specification and submission of of the report of B.D.V. Test and Chemical analysis of the oil to determine the level of acidity as per IS: Specification and cleaning of breather and providing fresh charges of Silica Gel to the transformers, Supplying and replacing corroded nuts and bolts, gaskets and washers, etc. (Transformers oil for topping up will be supplied separately.) b) Second year i) Transformer 11 KV/ 433 Volts, 2 MVA
Filtration and dehydration of oil for the following installations including testing of the Oil for dielectric strength before and after filtration as per IS: Specification and submission of of the report of B.D.V. Test and Chemical analysis of the oil to determine the level of acidity as per IS: Specification and cleaning of breather and providing fresh charges of Silica Gel to the transformers, Supplying and replacing corroded nuts and bolts, gaskets and washers, etc. (Transformers oil for topping up will be supplied separately.) b) Second year ii) Transformer 3.3 KV/ 433 Volts, 250 KVA
Filtration and dehydration of oil for the following installations including testing of the Oil for dielectric strength before and after filtration as per IS: Specification and submission of of the report of B.D.V. Test and Chemical analysis of the oil to determine the level of acidity as per IS: Specification and cleaning of breather and providing fresh charges of Silica Gel to the transformers, Supplying and replacing corroded nuts and bolts, gaskets and washers, etc. (Transformers oil for topping up will be supplied separately.) b) Second year iii) Transformer 3.3 KV/ 433 Volts, 100 KVA
Filtration and dehydration of oil for the following installations including testing of the Oil for dielectric strength before and after filtration as per IS: Specification and submission of of the report of B.D.V. Test and Chemical analysis of the oil to determine the level of acidity as per IS: Specification and cleaning of breather and providing fresh charges of Silica Gel to the transformers, Supplying and replacing corroded nuts and bolts, gaskets and washers, etc. (Transformers oil for topping up will be supplied separately.) b) Second year iv) 3.3 KV HT extensible oil switch fuse unit/ Isolator
Filtration and dehydration of oil for the following installations including testing of the Oil for dielectric strength before and after filtration as per IS: Specification and submission of of the report of B.D.V. Test and Chemical analysis of the oil to determine the level of acidity as per IS: Specification and cleaning of breather and providing fresh charges of Silica Gel to the transformers, Supplying and replacing corroded nuts and bolts, gaskets and washers, etc. (Transformers oil for topping up will be supplied separately.) b) Second year v) 3.3 KV, Oil immersed Ring Main Units of 200 -400 Amps capacity consisting of one incomer and two outgoings.
Filtration and dehydration of oil for the 11 KV, 1600 Amp. HT MOCB including co-ordination with M/s. Reliance for taking shut down of the supply, disconnecting the control supply, racking out the MOCB, cleaning the bus bar fingers and insulators, racking in the MOCB after filtration and dehydration of the oil and connecting the control supply properly and charging the HT panel in co-ordination with M/s. Reliance and testing the supply and controling, etc. (Transformer oil for topping up will be supplied separately.) a) First year
Filtration and dehydration of oil for the 11 KV, 1600 Amp. HT MOCB including co-ordination with M/s. Reliance for taking shut down of the supply, disconnecting the control supply, racking out the MOCB, cleaning the bus bar fingers and insulators, racking in the MOCB after filtration and dehydration of the oil and connecting the control supply properly and charging the HT panel in co-ordination with M/s. Reliance and testing the supply and controling, etc. (Transformer oil for topping up will be supplied separately.) b) Second year
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. a) First year i) Transformer 11 KV/ 433Volts, 2 MVA
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. a) First year ii) Transformer 3.3 KV/ 433Volts, 250 KVA
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. a) First year iii) Transformer 3.3 KV/ 433Volts, 100 KVA
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. a) First year iv) Transformer 320 KVA Dry Type
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. a) First year v) 11 KV HT MOCB panel with busbars consisting of 1600 Amp. two incomer, two outgoings and one buscoupler including CT & PT.
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. a) First year vi) 3.3 KV HT extensible oil switch fuse unit/ Isolator
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. a) First year vii) 3.3 KV, Oil immersed Ring Main Units of 200 -400 Amps capacity consisting of one incomer and two outgoings, job includes rectification of Oil leakage, etc. as required.
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. b) Second year i) Transformer 11KV/ 433Volts, 2 MVA
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. b) Second year ii) Transformer 3.3KV/ 433Volts, 250 KVA
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. b) Second year iii) Transformer 3.3KV/ 433Volts, 100 KVA
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. b) Second year iv) Transformer 320 KVA Dry Type
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. b) Second year v) 11 KV HT MOCB panel with busbars consisting of 1600 Amp. two incomer, two outgoings and one buscoupler including CT & PT.
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. b) Second year vi) 3.3 KV HT extensible oil switch fuse unit/ Isolator
Annual maintenance contract of following capacity of Transformers to maintain in serviceable condition including tightening of HT and LT terminations, cleaning of breathers etc as per preventive maitenance periodically as per Annex-I(A) and Annex- I(B) for a period of one year, submission of test/service reports as per Maintenance shedule, etc. complete as required. b) Second year vii) 3.3KV, Oil immersed Ring Main Units of 200 -400 Amps capacity consisting of one incomer and two outgoings, job includes rectification of Oil leakage, etc. as required.
AMC of L&T make Air Circuit Breakers installed at LT Ess. and Non-Ess. Panels as Main incomers, DG incomers and Bus Couplers and Incoming feeders of AC Panel of the following rating:- a) First year i) 3200 Amp, 4 Pole, U Power Series ACB
AMC of L&T make Air Circuit Breakers installed at LT Ess. and Non-Ess. Panels as Main incomers, DG incomers and Bus Couplers and Incoming feeders of AC Panel of the following rating:- a) First year ii) 1600 Amp, 4 Pole, U Power series ACB
AMC of L&T make Air Circuit Breakers installed at LT Ess. and Non-Ess. Panels as Main incomers, DG incomers and Bus Couplers and Incoming feeders of AC Panel of the following rating:- a) First year iii) 800 Amp, 4 Pole, C Power Series ACB
AMC of L&T make Air Circuit Breakers installed at LT Ess. and Non-Ess. Panels as Main incomers, DG incomers and Bus Couplers and Incoming feeders of AC Panel of the following rating:- b) Second year i) 3200 Amp, 4 Pole, U Power Series ACB
AMC of L&T make Air Circuit Breakers installed at LT Ess. and Non-Ess. Panels as Main incomers, DG incomers and Bus Couplers and Incoming feeders of AC Panel of the following rating:- b) Second year ii) 1600 Amp, 4 Pole, U Power series ACB
AMC of L&T make Air Circuit Breakers installed at LT Ess. and Non-Ess. Panels as Main incomers, DG incomers and Bus Couplers and Incoming feeders of AC Panel of the following rating:- b) Second year iii) 800 Amp, 4 Pole, C Power Series ACB
AMC of 800 Amp Vaccum Circuit Breakers installed at ELDIS-II (New RADAR) in operational area, Mumbai airport. a) First year
AMC of 800 Amp Vaccum Circuit Breakers installed at ELDIS-II (New RADAR) in operational area, Mumbai airport. b) Second year
Visiting charges towards inspecting, checking, taking parameters and rectification of the faults if require for ACB. (Beyond 4 nos. preventive maintenance and 8 nos. breakdown complaints.)
Testing and calibration of Voltage and current operated relays as per Annex -II including secondary injection testing and settings once in a year, submitting test reports etc complete as required. Job includes checking proper co-ordination of relays, testing of tripping, checking all the control systems, checking and testing electrical interlocking, checking of control wiring, tightening of the wiring, etc. complete as required. a) First year
Testing and calibration of Voltage and current operated relays as per Annex -II including secondary injection testing and settings once in a year, submitting test reports etc complete as required. Job includes checking proper co-ordination of relays, testing of tripping, checking all the control systems, checking and testing electrical interlocking, checking of control wiring, tightening of the wiring, etc. complete as required. b) Second year
Cable fault detection of HT / LT underground power cables of the 1.1 KV grade of any size with the cable fault finding machine complete etc. as required.
Supply of transformer oil of IS: 335/1980 ammended upto date with test report as required.
Repainting of following equipments including scrapping by sand/emery paper to get even surface and applying metal primer on corroded surface and painting with two coat of approved brand synthetic enamel/Aluminum paint including writing, etc. complete as required. a) Transformer 11KV/ 433Volts, 2 MVA
Repainting of following equipments including scrapping by sand/emery paper to get even surface and applying metal primer on corroded surface and painting with two coat of approved brand synthetic enamel/Aluminum paint including writing, etc. complete as required. b) Transformer 3.3KV/ 433Volts, 250 KVA
Repainting of following equipments including scrapping by sand/emery paper to get even surface and applying metal primer on corroded surface and painting with two coat of approved brand synthetic enamel/Aluminum paint including writing, etc. complete as required. c) Transformer 3.3KV/ 433Volts, 100 KVA
Repainting of following equipments including scrapping by sand/emery paper to get even surface and applying metal primer on corroded surface and painting with two coat of approved brand synthetic enamel/Aluminum paint including writing, etc. complete as required. d) 11 KV HT MOCB panel.
Repainting of following equipments including scrapping by sand/emery paper to get even surface and applying metal primer on corroded surface and painting with two coat of approved brand synthetic enamel/Aluminum paint including writing, etc. complete as required. e) 3.3 KV, 200/400 Amp Ring Main Units and Isolating switch
CIS ELECTRICALS PVT LTD
Manish Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .