| 1 | L1₹12.7 LAccepted-AOC JOGESHWARI W 758 ADARS NEW LINK ROAD 758 ADARS MUMBAI 400101 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.3 L+₹1.3 L (10.3%)Rejected-Finance | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹14.4 L+₹1.4 L (11.1%)Rejected-Finance B 145 VIKAS NAGAR COMMANDER CHOWK NEW DELHI 59 PIN 110059 | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹14.4 L+₹1.5 L (11.2%)Rejected-Finance B 12 BASEMENT PLOT NO 19 RETAIL BUSINESS CENTRE ADITYA COMPLEX NANGAL RAYA SOUTH WEST NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Being Not Lowest | |
| 5 | L5₹14.6 L+₹1.6 L (12.4%)Rejected-Finance GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L5 | Rejected-Finance Being Not Lowest |
Tender Value
Refer Docs
EMD Value
₹34,340
Closing Date
27 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lansdowne
Garrison Engineer Lansdowne Distt- Pauri Garhwal Pin-246155
SPL REPAIR BLDG NO P-137 AND P-138 (SINGLE JCOS ACCN) AT GRRC AND PROVN OF OIL STORE NEAR BLDG NO T-3 AT RECORDS GARH RIF LANSDOWNE UNDER GE LANSDOWNE
2020_MES_382157_1
8555/E8
Open Tender
Civil Works
Item Rate
180 days
GE Lansdowne
Class E Category a (i)
6 documents required · 6 mandatory
₹500
GE Lansdowne
₹34,340
21 Dec 2020
30 Sept 2020
29 Oct 2020
30 Sept 2020
27 Oct 2020
15 Oct 2020
60 days
Amount
Taking down Chowkats with shutter exceeding 1.5 sqm . but n . Exc 4sqm each (Without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats with shutter n. exc 1.5 sqm each. (without taking of shutter from the frame) complete all as specified and directed.
Taking down shutter of any description exc. 1 sqm but n exc 2 sqm complete all as specified and directed.
Taking down shutter of any description n. exc. 1 sqm complete all as specified and directed.
S&F steel ventilators with top hung shutter including hinges steel peg stay complete all as specified and directed.
M&L Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M & L for cement concrete cast-in situ Type B-1(1:2:4) (using 20 mm graded stone aggregate), in lintels up to 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
S & F 25 mm thick Second class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkat complete all as specified and directed.
S & F 35 mm thick Second class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkat complete all as specified and directed.
S & F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided in to squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc complete all as specified and directed.
S & F solid PVC door frames of sizes 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed.
S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail , lock rail and bottom rail on either side and as gap insert for top rail and bottom rail , panelling of plain colour PVC sheet to be fitted in the MS framewelded/ sealed to the stiles and rails with suitable PVC sheet beading , and jointed together with solvent cement in the frame at site as per specification.
Resecuring or easing & adjusting without taking down shutter of any descriptio exc. 1 sqm but n exc 2 sqm complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutter of any descriptio n. exc. 1 sqm complete all as specified and directed.
S&F galvanised mild steel wire cloth ,0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks,or galvanised wire steples complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth ,0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks,or galvanised wire steples complete all as specified and directed.
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sq.m. each pane including hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
S&F 4 mm thick figured ,pin head type and glazing with oil putty in square n. exc 0.5 sq.m. each pane complete all as specified and directed.
S & F Aluminium alloy anodised sliding door bolt with hasp & staple ( bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections cast aluminium alloy lenght of 250 mm complete all as specified and directed.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 125 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed.
S & F 75 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed.
S & F aluminium handle 150 mm long anodised, cast type fixed complete complete all as specified and directed.
S & F aluminium handle 125 mm long anodised, cast type fixed complete all as specified and directed.
S & F aluminium anodised hasp and stple 125 mm long , safety type, including bolt to hinge plate and fixed with screws complete all as specified and directed.
M&L for Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed.
M&L for Preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
M&L for Preparation of New or previously untreated steel and iron surfaces of any description, over 10 cm width or girth not otherwise described and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide complete all as specified and directed.
M & L for preparation of old painted steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparation of New or previously untreated steel and iron surfaces of any description, n. exc 10 cm width or girth when unconnected with other painting or when painted in a different tint and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide complete all as specified and directed.
Disconnecting existing tanks, setting side (or lowering if required) for repairs, cleaning and removing all scale and dirt etc. from tanks and mouths of circulating pipes etc. and hoisting if required reconnecting and refixing in position exc 250 Ltrs but n .exc 500 Ltrs capacity complete all as specified and directed.
Dismantling water tanks exc 250 & n exc 500 capacity in litres and removing to store complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) Hoisted and fixed in position of 500 ltrs capacity
S&F in repairs 20 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210gms./ 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in Stone concrete block or slab walls complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection including cleaning for refixing or removel to store complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connection including cleaning for refixing or removel to store complete all as specified and directed.
S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors incl taking down complete all as specified and directed.
Refixing to old steel tubing 15mm dia and connection in new or old position (wall ceiling floor etc.) complete all as specified and directed.
S & F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors incl taking down complete all as specified and directed.
Refixing to old steel tubing 20mm dia and connection in new or old position (wall ceiling floor etc.) complete all as specified and directed.
S & F in repair vitreous china squatting pan Orissa pattern size 580mm x 440mm white with integral foot rest including provision of lime concrete bedding, connection to trap and flush pipe etc as in floor all as specified and as sdirected.
S&F in repairs vitreous china ware wash hand basins, white flat size 550x400mm (excluding taps, waste, chain and plug and porcelain stopper but including brackets) complete all as specified and directed.
S&F inrepairs soap dish,vitreious china white, approximate size 160*160*90 mm fixed to plug with cromium plated screws complete all as specified and directed.
S & F in repair 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve and brackets float and handle, and bracket complete all as specified and directed.
S & F PVC connection pipe 15mm size with PTMT nuts of 450 length including fixed in repairs complete all as specified and directed.
S &F in repairs swivel shower of PTMT any colour for fixing with 15mm dia pipe (Min weight 40 gms) complete All as specified and as directed.
S &F in repairs shower arm 15mm size 195mm long with bend of 45 degree with flange of PTMT any colour (Min weight 40 gms) complete all as specified and as directed.
S & F in repair bib taps 15mm bore cast copper alloy chromonium plated with crutch or butterfly, handle, screwed down, screwed for iron pipe complete all as specified and directed.
S & F in repairs stop valve15mm bore cast copper alloy chromonium plated screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repair stop valve15mm bore cast copper alloy fancy type chromonium plated with long shank and cup(concealed type) screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs pillar taps cast copper alloy fancy type with capstan heads,CP screwed down high pressure ,with or without lettered "Hot or Cold "with long screw shanks for 15mm bore of iron pipe complete all as specified and directed.
S & F in repairs towel rail 600mm long of chromium plated brass screw and wooden / plastic cleats complete all as specified and directed.
S & F in repairs 110mm bore PVC Pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) junction, single equal or unequal complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S & F in repairs 75 mm bore PVC Pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S & F in repairs 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S & F 75 mm bore PVC (SWR) junction, single equal or unequal complete all as specified and directed.
M & L in repairs 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
Demolition of brick / stone work built in cement mortar including all quians, pillars etc. complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster of any description on brick walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L rendering 15 mm thick on external surfaces of wall in cement mortar 1:4 with using water proofing treatment all as specified and directed.
Material & labour for Rendering 10 mm thick CM 1:6 using water proofing liquid compound as per manufacturer's instructions on brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
M&L rendering 5mm thick on fair faces of brick work or concrete sufaces in cm (1:4) as in ceiling complete all as specified.
M & L preparing new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M & L preparing new plastered surfaces of internal walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L preparing old plastered surfaces of walls as required and applying two coats of distemper oil emulsion complete all as specified and directed.
M&L preparing of old plastered or un plastered surface of walls and applying two coats of white wash complete all as specified and directed.
M & L preparing old plastered surfaces of ceiling as required and applying two coats of white washing complete all as specified and directed.
M & L Preparing new plaster surface of ceiling and applying three three coats of white wash complete as specified and as directed.
Demolition of cement concrete (reinforced) not exc. 15 cm thick complete all as specified and directed.
M & L for mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, inlcluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Engr-in-Charge
M & L for providing precast reinforced cement concrete type B1, 1:2:4 (20 mm graded stone agg) nominal mix in chajjas, shelves, manhole cover and similar work complete with necessary form work and set in CM 1:6 all as spdand directed.
Demolition concrete in situ in ground floors and paving n exc 15 cm thickness(below or above ground floor) complete all as specified and directed.
M & L PCC Type C-2 1:3:6 (using 40 mm graded stone aggregate) as in surface channels and drains or benching in manholes complete including necessary form work as specifed and directed.
M & L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed.
M & L PCC 1:3:6 type C2 (75 mm thick as in plinth protection & finishing the surface even & fair whtiout using extra cement complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated materials n exc 50 mtrs and deposited where directed at a level n exc 50 mtr where directed n exc 1.50 m above the starting point complete all as specified and directed.
Demolition and breaking up 150 mm internal dia drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M&L 150 mm bore Salt-glazed stoneware drain pipes laid in trenches and jointed as specified SGSW drain pipes laid in trenches complete all as specified and directed.
M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in concrete bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipes complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L 15 mm thick in cement mortar 1:4 screed bed or bedding layer of mortar for laying floor finishes complete all as specified and directed.
M&L for non skid cereamic coloured tiles 7 to 8mm thick (square/ rectangle) area of each tiles exceeding 0.11 sqm but n. exc.0.18sqm, in floor etc set and joined in neat cement slurry and pointed in white or .coloured cement to match complete all as specified and directed.
M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with gray cement pigments complete all as specified and directed.
M & L Rendering 10 mm thick in cement mortar (1:3) as in backing layer for laying of tiles in vertical surfaces complete all as specified & directed.
M&L glazed, coloured, ceramic, tiles of size (300mm x 200 mm) x 6 to 7 mm thick, on vertical surfaces, such as dadoes, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles all as specified and directed.
M&L for taking down of existing sunken slab treatment from the sunken portion and cleaning the surfaces by washing down with water and rubbish off the permises including as under:-Cleaning and filling crackes with sealing compound, brushing neat with neat cement slurry@ 3.0 Kg per Sqm and grouting in 25 mm thick PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregates over sunken slab portion and finishing the top surface even and smooth without using extra cement and carrying out the roof treatment by applying the following process through authorised applicator of the company: - (i) MPB coating or URP coating by applying primer coating of Dr Fixit Pidicrete URP duly mixed with cement in ratio 3:10 by weight. (ii) URP coating by applying primer coating of STP ShaliCrete URP/Dr Fixit Pidicrete URP duly mixed with cement in ratio 1:5 by weight. (iii) Applying two coats of STP ShaliCem EWP/Dr Fixit Pidifin 2K as per manufacturer's instructions. (iv) Applying 10 mm thick rendering of mortar obtained by mixing portland cement - 50 Kg, Washed sand - 150 Kg, STP ShaliCrete URP/Dr Fixit Pidicrete URP 6-7.5 Kg and water 10 Litres.
M&L for taking down existing roof treatment of any type completely and cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and providing roof treatment complete all as described in the following process after the surface is completely dried: - i) Applying cement slurry @ 3.00 Kg/Sqm on cleaned roof surfaces and over it 20 mm thick screed in CM 1:4, finished even and smooth without using extra cement. ii) Applying a coat of cold applied polymeric modified bituminous primer @ 0.30 Kg/Sqm. iii) Providing APP based 5 layer polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by torch application as per the manufacturer's instructions with side over lap of 75mm and end over lap of 100mm. iv) Applying a coat of polymeric modified bitumen 85/25 @ 1.2 Kg/Sqm. v) Applying a coat of Super Silver shield @ 0.10 Kg/Sqm. Note: The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer only.
Excavation in trenches not exc 1.50m wide and not exc 1.50m depth for foundation etc or for shefts, wells complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) foundation fillings and mass concrete complete all as specified and directed.
M&L Brick work with fly ash brick, straight or curved on plan exc 6 mtrs mean radius and built in cement mortar 1:6 all as specified and directed.
M&L 40mm thick DPC in cement concrete 1:2:4 type B-0 mixing with liquid water proofing admixture as per manufacturer instructiions including necessary form work complete all as specified and directed. (WPC shall be measured & paid seperateley)
Supply only integral water proofing compound complete all as specified and directed.
M&L Broken bricks hardcore of gauge 63mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M&L Cement concrete 1:4:8 type D2 using 40mm graded agg 75 mm thick as in sub base of floor etc complete all as specified and directed
M & L for Rendering 15 mm thick in two coats i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
M&L for Preparation of newly plaster surface of wall and applying three coats of white wash complete all as specified.
S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fasternings and heavy bracket framing (beam, tee, angle, channel or flat secitons) including distance pieces, cleats etc conforming to Fe 290 Gde E-165 complete all as specified and directed.
S&F pre painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F rolled MS framed work as in doors or gate of angle or other section with gusset plate, rail, brases etc ornamental and intricate design, including either hooks and hinges or steel hanging door fitting to be prepared for hanging and also fastening conforming to Fe 290(Gde E-165 ) complete all as specified & directed.
S&F for hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securig wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
S&F Mild steel, plain, black sheet 0.80mm in steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc complete all as specified and directed.
S&F Butt hinges, 40mm heavy weight, cold rolled mild steel, and fixed complete all as specified and directed.
S&F Mild steel pressed handles, oval type, stove enamelled blac complete all as specified and directed.
S&F Mild steel sliding door bolts, 250mm plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars dovetailed or welded, complete all as specified and directed
Supply & fix 3mm thick sheet glass, ordinary quality glazing with oil putty of make Shalimar Hardware or fixed with wooden beads or in steel windows in square n.exc. 0.50sqm each pane complete all as specified and directed.
M&L kota stone slab 20-25 mm thick as in floor etc over and including 15mm screed bed in cement mortar 1:6 cement & jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing & polishing to achive mirror finish an roughning the surfaces complete all as specified and directed .
M&L kota stone slab 20-25 mm thick as in landing/risers/treads/skirting/dado etc over and including 10mm screed bed in cement mortar 1:4 cement & jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing & polishing to achive mirror finish an roughning the surfaces complete all as specified and directed .
M&L for sand filling 50 mm thick under floor or in foundation complete all as spd and directed.
Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, socket, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfaces of walls, floors, etc.
M&L for point wiring light/fan/bell point with PVC insulated FRLS unsheathed single core cable of multistranded copper conductor of size 1.5 sqmm as phase & neutral drawn in and including PVC conduit(HMS), duly concealed to wall/floor or above false ceiling of suitable size with all fitting and accessories laid on wall/ceiling alongwith 1.5 sqmm stranded PVC insulated unsheathed copper conductor(Green in color) as earth wire and connected to common earth dolly for the following incl making good to surface with CM(1:4) plaster and paint to match the surface complete incl provn of CI/pressed steel terminal switch box and white bakelite plastic laminated top sheet cover and fixed with brass screws cup washer for fixing switches/socket/regulators etc complete all as specified and directed for the following: - (a) one light/bell/fan point
All as per item no 121 here in above but one light point controlled by one piano type switch 5 Amps single pole two way complete all as specified and directed.
All as per item no 121 here in above but for one 3 pin 5 Amps socket outlet on same board controlled by one 5 Amps piano switch one way complete all as specified and directed.
All as per item no 121 here in before but for one 5 pin switch socket outlet 5A on independent board controlled by one 5 Amps piano switch one way complete all as specified and directed.
M&L for point wiring 15Amp indep point with PVC insulated FRLS unsheathed single core cable of multistranded copper conductor of size 2.5 sqmm as phase & neutral drawn in and including PVC conduit(HMS), duly concealed to wall/floor or above false ceiling of suitable size with all fitting and accessories laid on wall/ceiling alongwith 1.5 sqmm stranded PVC insulated unsheathed copper conductor(Green in color) as earth wire and connected to common earth dolly for the following incl making good to surface with CM(1:4) plaster and paint to match the surface complete incl of CI/pressed steel terminal switch box and white bakelite plastic laminated top sheet cover and fixed with brass screws cup washer for fixing switches/socket/regulators etc complete all as specified and directed
S&F Switch Piano Flush button single pole one way 5 Amp complete all as specified and directed
S&F Bell Push Switch Piano Flush button single pole one way 5 Amp complete all as specified and directed
S&F Switch Piano Flush button single pole two way 5 Amp complete all as specified and directed
S&F socket outlet flush type 3/5 pin 5/6 Amps 230V AC complete all as specified and directed.
S&F switch piano flush type single pole one way 15/16 Amps complete all as specified and directed.
S&F socket outlet flush type 5/6 pin 15 Amps 230V AC complete all as specified and directed.
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting complete all as specified & directed
M&L ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as specified and directed.
S&F in replacement calling bell ding dong AC 230 volts single pole complete all as specified and directed.
S&F MCB DB TPN 04 way with 200 amps 415 volts rated copper busbar in sheet steel enclosure double door type complete all as specified and directed.
S&F MCB DB SPN 6 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure double door type complete all as specified and directed.
Supply & fixing MCB , SP, AC, 240 volts of 06/10/16 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply & fixing MCB, SPN, AC, 240 volts of 10/16/25 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply & fixing MCB, SPN, AC, 415 volts of 40 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
Disconnecting and taking out old unserviceable submian wiring and S&F sub main wiring with two single core PVC insulated,unsheathed, multistranded copper conductor cable 6 Sqmm with one single core 4 Sqmm PVC insulated, unsheathed, stranded copper conductor cable as earth wire(green in color) in and including PVC conduit(HMS), duly concealed to wall/floor or above false ceiling of suitable size with all fitting and accessories laid on wall/ceiling and earth wire connected to common earth point complete all as specified & directed.
Disconnecting the unserviceable under ground cable, taking out the same and supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 1554) in trenches / ducts / through GI pipes under roads of size 16 sqmm 4 core complete all as specifed and directed. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate items of Sch A
Excavation in trenches in soft/disintegrated soil not exc 1.5 m wide and not exceeding 1.5m in depth for laying UG cable/foundation etc complete all as specified and directed.
Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and spread fine river sand in trenches as cushioning to underground cable on top and bottom of cable complete all as specified and directed(measurement to be taken after punning down).
M&L for cable protection bricks common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches complete all as specified and directed at site.
Disconnecting and dismantling old U/S tube light and Supply, fixing & testing 20 W LED tube light all purpose surface and wall mounted LED batten with aluminum housing & integrated electronic driver, 4 feet long complete complete all as specified and directed. Make :- Havells Cat No lumilinePlusBs20Wled865sPCss or equivalent make in Philips/Wipro
Disconnecting and dismantling old U/S bldg light and supply, fixing & testing 30 W LED road way light fitting/Bldg light mounting type made out of one piece in pressure die-cast aluminium, alloy powder coated housing enclosed with glass cover in frame fitted luminaries complete with electronic driver and all accessories suitable for & including lamp 30 W with suitable No's of LEDs and GI pipe bracket 32mm dia light grade bend to shape duly painted with aluminum paint over one coat of red oxide primer fixed to wall with nuts, bolts etc as directed. The fitting shall IP 65 protection and impact resistance of iK07 with 10KV Built-in surge Protection device duly prewired complete complete all as specified and directed. Make :- EnduraCitYlitePlatPlussl30Wled757sasYBoPC or equivalent make in Philips/Wipro
Disconnecting and taking out old unserviceable bulb and S&F LED bulb 10 W complete all as specified and directed. Make:- Havells LED ADORE 10 W B22 CDL 3 STAR LAMP or equivalent make in Philips/Wipro
Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 32 mm bore, light grade as in sleeving etc laid in trenches / pole post /under culvert/ under road etc. complete all as specified and directed .
M&L, for earthing in replacement with galvanized earth plate electrode 600x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvanized earth lead wire of 4 mm dia by means of nuts, bolts, washer of galvanized iron or steel all as shown in electrical plate No 5 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-0 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and connecting the GI wire to Bldg DB inside GI pipe light grade 20 mm dia fixed to wall of bldg complete all as specified and as directed.
M&L for point wiring light point with PVC insulated FRLS unsheathed single core cable of multistranded copper conductor of size 1.5 sqmm as phase & neutral drawn in and including stove enameled steel conduit, duly concealed to wall/floor or above false ceiling of suitable size with all fitting and accessories laid on wall/ceiling alongwith 1.5 sqmm stranded PVC insulated unsheathed copper conductor(Green in color) as earth wire and connected to common earth dolly for one flame proof light point controlled by one flame proof switch complete as as specified and directed.
Supply and fix Switch flame proof rotary type with termination box in LM6, 16A, Double pole 250V complete all as specified and directed.
Supply and Fix flame proof Led tube light 20 W complete all as specifed and directed. Make:- Crompton Fiamma II cat part no. EXTN1LT8-16/20 or equivalent
Supply and fix flame proof exhaust fan single phase 230V 300 mm sweep, .25HP, 1120 CFM complete all as specifed and directed. Make:- Sudhir EF/140 or equivalent
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 1554) in trenches / ducts / through GI pipes under roads of size 10 sqmm 2 core complete all as specifed and directed. Note;- The earth work, GI pipe shall be measured and paid seperately under appropriate items of Sch A
Supplying, laying & jointing GI water tubing, 25 mm bore, light grade as in sleeving etc laid in trenches / pole post /under culvert/ under road etc. complete all as specified and directed .
SHRISHTI ENTERPRISES
M/s Candid Mask Networks Pvt Ltd
S D Constructions
Panwar Electrical
RAMAPATI ENGINEERING SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .