PLWSS Shout Nanj and Chouridhar in Tehsil Karsog Distt Mandi HP SH_Providing and laying rising main and supply and installation of centrifugal pumping machinery with allied accessories Ist IInd and IIIrd stage
2021_HPIPH_54938_1
KSG-MDI10-764
Open Tender
Pumps/Motors
Item Rate
180 days
Nanj
Please refer Tender documents.
9 documents required · 9 mandatory
₹800
Yes
₹1.1 L
Yes
13 Jan 2022
22 Dec 2021
30 Dec 2021
22 Dec 2021
29 Dec 2021
22 Dec 2021
Amount
Excavation in foundation, trenches ( for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposoited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration unmetalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-Charge.
Providing and laying;Jointing and testing in trenches to be levelled to grades IS marked ,MSERW flanged pipe of following dia meters conforming to IS 1978 YST 210 or x 42 (latest with up to date ammdments) having minimum wall thickness as specified below of steel grade LX 290 or 42 jointed with flanges conforming to table as specified below of IS 6392-1971 (latest with upto date ammendments )welded at both ends according to relevant IS standard and detailed specifications and provided with nuts and bolts of required size,3mm thick compressed asbestos fiber gasket or synthetic rubber gasket conforming to relevant IS codes including all short pieces,bends tees,and other specials extra made from parent tubes and welded with flanges of tables as applicable to the particular reach and of approved specifications as per site condition including flushing,cleaning,painting and hydraulic testing complete. The pipes and specials shall have galvanised coating as per ISW-4736 with latest ammendments at following RDs.
RDs 1st stage from to Length Dia Class wall thick Flanged TableTotal Length . 0 110 110 100 MS Pipe 4.00 28 110 Rmt.
RDs 2nd stage from to Length Dia Class wall thick Flanged TableTotal Length . 0 100 100 100 MS Pipe 4.40 34 100 Rmt.
RDs 3rd stage from to Length Dia Class wall thick FlangedTable Total Length . 0 75 75 100 MS Pipe 4.80 34 75 Rmt.
Providing, Laying, jointing and testing of MS Pipe L-290 (X-42) bevelled edged conforming to ISO:3183-2007 of following mentoned grade, diameter and wall thickness in trenches having random lengths of 5-7 mtrs including cost of fabrication of minimum 3 cut bends of required degree. The pipe shall have inside & out side Galvanisation at manufacturer work conforming to IS:4736 (with upto date ammendments). The pipe shall be jointed with circumferencial butt welded joints by electric arc welding with minimum three layers of welds so as to achive the minimum effective thorat thickness and strength of welds conforming to IS: 816-1969 sepecification, by using welding electrodes of 2.50 mm to 6.30 mm of Advani Oerlikon (Ador)- CITOJET / Esab make, conforming to IS:814-1991, at site of work complete in all respects. Each butt welded joint shall be tested with dye-penetration test ( with the kit consisting of 3 sprays of 250 ML each includes (a) Cleaner CL-96 (b) Penetrant PT-97 (c) Developer Div-98 of checkmate make) complete in all respects, including manual / mechanical handling of pipes in all leads and lifts to the entire satisfication of Engineer-in-charge. (The earth work in treches and cost of MS flanges to be measured and paid for separately)
RDs 1st stage from to Length Dia Class wall thick ButtWelded Total Length . 110 600 490 100 MSPipe 4.00 ButtWelded 490 Rmt.
RDs 2nd stage from to Length Dia Class wall thick ButtWelded Total Length . 100 600 500 100 MSPipe 4.40 ButtWelded 500 Rmt.
RDs 2nd stage from to Length Dia Class wall thick ButtWelded Total Length . 600 900 300 100 MSPipe 4.00 ButtWelded 300 Rmt.
RDs 3rd stage from to Length Dia Class wall thick ButtWelded Total Length . 75 300 225 100 MSPipe 4.80 ButtWelded 225 Rmt.
RDs 3rd stage from to Length Dia Class wall thick ButtWelded Total Length . 300 600 300 100 MSPipe 4.40 ButtWelded 300 Rmt.
RDs 3rd stage from to Length Dia Class wall thick ButtWelded Total Length . 600 900 300 100 MSPipe 4.00 ButtWelded 300 Rmt.
Laying, jointing and testing of GMS pipe bevelled edged conforming to IS:1239 of following size and class in trenches having random lengths of 5-7 mtrs including cost of fabrication of minimum 3 cut bends of required degree. The pipe shall have inside & out side Galvanisation at manufacturer work conforming to IS:4736 (with upto date ammendments). The pipe shall be jointed with circumferencial butt welded joints by electric arc welding with minimum three layers of welds so as to achive the minimum effective thorat thickness and strength of weld conforming to IS: 816-1969 sepecification, by using welding electrodes of 2.50 mm to 6.30 mm of Advani Oerlikon (Ador)- CITOJET / Esab make, conforming to IS:814-1991, at site of work complete in all respects. Each butt welded joint shall be tested with dye-penetration test ( with the kit consisting of 3 sprays of 250 ML each includes (a) Cleaner CL-96 (b) Penetrant PT-97 (c) Developer Div-98 of checkmate make) complete in all respects, including manual / mechanical handling of pipes in all leads and lifts to the entire satisfication of Engineer-in-charge. (The earth work in treches and cost of MS flanges to be measured and paid for separately).
RDs 1st stage from to Length Dia Class wall thick ButtWelded Total Length . 600 2200 1600 100 Medium 4.50 ButtWelded 1600 Rmt.
RDs 2nd stage from to Length Dia Class wall thick ButtWelded Total Length . 900 2000 1100 100 Medium 4.50 ButtWelded 1100 Rmt.
RDs 3rd stage from to Length Dia Class wall thick ButtWelded Total Length . 900 1500 600 100 Medium 4.00 ButtWelded 600 Rmt.
Providing of horizontal spindle,horizontal/redial split casing/end suction (backpull out arrangement) Single/double/Multistage centrifugal pumps or combination of pumps,.in series/parallel of recommended make such as KSB/Mather & Platt /Kirloskar/ Beaconweir/BE / Grundfos pump/LUBI Pump as per BIS 1520-1980 with upto date ammendments) read with IS 9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze ,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade------- with cast iron casing coupled directely through a flexible coupling on a common CI/cast steel base plate(base plate to be from the manufacturer of the pumping unit only) to slip ring/squirrel cage screen protected drip proof induction motor/motors of standard make such as kirlokar/BHEL/NGEF /GEC/Crompton/ Siemen/Marthon/ABB and suitable for operation on 415(+/-)5% volts,50 cycles/second ,3 phase AC electric supply. The power of electric motor/motors should be at least +15% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-) 15% of the duty point head.The motor/motors as per IS: 325-1978 with upto date ammendments read with IS: 900-1972. It should include cost of bearing ,nuts,bolts and painting etc. and should meet the following requirements:- (2 Set of 50 HP Each= 100).
(A).SITE CONDITION :- (i) Location of Site About 18 Km from Churag :- Near Village Parlog Bridge (ii) The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mt :- 719 Mtrs (iii)Humidity:- Weather generally remains humid during monsoon Season. (iv) Nature of Atmosphare:-As normally encountered in Shivalik Range. (v) Detail of quality of water:-Clear cold water. (vi) Water free from sand or not:- Yes. (vii) Water corosive or not:-Not. (viii) Turbidity (if any):-Clear Cold WATER. (ix) NPSH available:- 8.994 Mts. (x) Any other information or requirement.
(B). OPERATING CONDITIONS :- (i) Type of current:-AC three/single phase. (ii) Operating frequency:- 50 HZ. (iii) Rated voltage:-400 (+/-) 10% volts. (iv) System of earthing if any to be adopted:-Double loop earthing as per BIS 3043-1987 latest with upto date ammendments. (v) No. of working hours per day :- 8 hours. (vi) Speed of revolution in RPM:- To be quoted by tenderer. (vii) Direction of rotation:-To be quoted by tenderer. (viii) The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.:- 25 degree centigrade.
(C). MOTOR :- (i) Ref to BIS code:-BIS 325- 1978 read with BIS 900-1992 (latest) with upto date ammendments. (ii) Type of enclosure of motor:-SPDP (as per BIS 4691-1985 (Latest). (iii) Type of duty:-Continuous. (iv) Mechanical out put in KW:-suitable for driving centrifugal pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. (v) Class of insulation:-Class- B. (vi) Max. permissible temp. rise of motor reqd. if different from given in B (viii) above. (vii) Particulars of test reqd. & where they are to be conducted:-As per terms & conditions. (viii) Particulars as to whether voltage limiting device will be employed:-ATS/star delta starter oil immersed fully automatic to be installed between bus bar chamber & motor.Shunt capacitor is also proposed to be installed for improving the power factor at site. NOTE :- Star delta starter upto 37.5 KW. ATS between 37.5 KW to 50 KW & Stator rotor starter with slip ring motor beyond 50 KW. (ix) Motor whether squirrel cage or slipring:- Squirrel cage/slipring. Note :- Squirrel cage upto 65HP and slipring above 65 HP. (x) Details of shaft extension reqd:- Just sufficient to provide direct drive by flexible coupling to pump.
(xi) Type of slip ring gear whether continously rated or for starting puposes only & whether to be fitted with brush lifting or short circuiting arrangements or bothe if interlocks are required.:-Continously rated for squirrel cage/ slipring motor. (xii) Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in curcuit:- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.(xiii) Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated & No. of starts during a specified period:- To work the pumps offered. (xiv) Where possible fault capacity of the systemto which the motor is connected:- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent defomations.
(D). PUMP (BIS 1520-1980) read with BIS 9137-1978 both latest with upto date ammendemnts :- (i) Nos of pumps reqd:-1 Nos. working pumps & 1 No. stand bye. (ii) Spare parts required:- For two years normal maintenance as recommended by manufacturer. (iii) Optional fittings reqd:-Air cock for exahausting air from each stage.
(E).PUMP OPERATING CONDITIONS :- (i) Capacity:- 5.18 LPS. (ii) Total head in Mts.:- 383.44 mtrs. (If total head is not known then follwing details be provided :- a) static Head: 358 mtrs, (b) Minimum depth of water: --------mtrs. (c) Variation in water level: ----- mtrs. (d) Ground level mex. Water level: 719 mtrs. (e) Ground level to delivery point: 1077 mtrs. (f) Pressure in the suction tank: ------ Kg/cm^2 (g) Pressure in the delivery tank: ------ Kg/cm^2 (h) Length of Rising main: 2200 mtrs.) (iii) Dia of R/main: 100mm. (iv) Drive arrangement:Direct through flexible coupling on a common base plate.(v) Drive type:-Electric driven. (vi) NPSH reqd:-To be quoted by the tenderer. (vii) Limits of total head in which the pump is reqd. to operate:-(-) 25% to (+) 10% of total head. (viii) Suction/delivery size of pump:-To be specified by the tenderer. (ix) Efficiency of pump at a) duty head,b) (+) 10% head,c) (-) 25 % head:-To be specified by the tenderer. (x) Material of construction:-To be specified by the tenderer (Manufacturer certificate to be appended).
Suply of suitable oil immeresd Star Delta Starter/ATS/stator Rotor Starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release with initial oil filling. Note:- Star- delta - starter upto 37.5 KW. ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50KW.
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltge difference.
Change over switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable cacpacity.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 104 Kg/cm^² NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirlosker/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pas arrangement & size equal to delivery of Pump for withstanding nominal seat pressure of 52Kg/cm^ ² NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Glad/Bhel/Leader of suitable size Cast Iron/Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 52 Kg/cm^²NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Glad/BHEL/Leader/of reputed make of suitable size cast iron flanged sluice valve confirming to IS 780, size equal to dia of suction pipe PN 1 Provided with hand wheel/Cast iron Cap.
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast iron flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with upto date ammendments.
P/L suitable size copper pVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) - 1988 or latest with upto date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phase) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipe or trenches under floor. The type size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Providing laying suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part-I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipes, solder, nuts & bolts, cable gland sets. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
Providing/Laying suction, delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure indicated in item No. 1e(ii). Note :- Actual laying to be done as per final drawings to be approved by the Engineer-in-Charge.
Errection of all equipments i/c cost of tees, bends tapers and any other fittings required as per site conditions and as per directions of Engineer-in-Charge.
2nd Stage:- Providing of horizontal spindle, horizontal/ redial split casing/end suction (backpull out arrangement) Single/double/Multistage centrifugal pumps or combination of pumps, in series /parallel of recommended make such as KSB/Mather & Platt/Kirloskar/ Beaconweir/ BE/ Grundfos pump/LUBI pump as per BiS 1520-1980 with upto date ammendments) read with IS 9137- 1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze impellers/ priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade with cast iron casing coupled directely through a flexible coupling on a common CI /cast steel base plate (base plate to be from the menufactourer of the pumping unit only) to slip ring/ squirrel cage screen protceted drip proof induction motor/ motors of standard make such as Kirlokar/ BHEL/ NGEF/GEC/Crompton/ Siemen/ Marthon/ ABB and suitable for operation on 415(+/-) 5% volts, 50 cycles/ second, 3 phase AC electric supply. The power of electric motor/ motors should be at lease +15% in excess of the maximum power required by the pump/ pumps in the operation range of (+) 10% and (-) 15% of the duty point head. The motor/motors as per IS: 325-1978 with upto date ammendments read with IS 1900-1972. It should include cost of bearing nuts, bolts and painting etc. and should meet the following requirements:-
(A).SITE CONDITION :- (i) Location of Site :- Near Shirmi (ii) The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mt :-1077 Mtrs (iii)Humidity:- Weather generally remains humid during monsoon Season. (iv) Nature of Atmosphare:-As normally encountered in Shivalik Range. (v) Detail of quality of water:-Clear cold water. (vi) Water free from sand or not:- Yes. (vii) Water corosive or not:-Not. (viii) Turbidity (if any):-Clear Cold WATER. (ix) NPSH available:-8.634 Mts. (x) Any other information or requirement.
(B). OPERATING CONDITIONS :- (i) Type of current:-AC three/single phase. (ii) Operating frequency:- 50 HZ. (iii) Rated voltage:-400 (+/-) 10% volts. (iv) System of earthing if any to be adopted:-Double loop earthing as per BIS 3043-1987 latest with upto date ammendments. (v) No. of working hours per day :- 8 hours. (vi) Speed of revolution in RPM:- To be quoted by tenderer. (vii) Direction of rotation:-To be quoted by tenderer. (viii) The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.:- 25 degree centigrade.
(C). MOTOR :- (i) Ref to BIS code:-BIS 325- 1978 read with BIS 900-1992 (latest) with upto date ammendments. (ii) Type of enclosure of motor:-SPDP (as per BIS 4691-1985 (Latest). (iii) Type of duty:-Continuous. (iv) Mechanical out put in KW:-suitable for driving centrifugal pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. (v) Class of insulation:-Class- B. (vi) Max. permissible temp. rise of motor reqd. if different from given in B (viii) above. (vii) Particulars of test reqd. & where they are to be conducted:-As per terms & conditions. (viii) Particulars as to whether voltage limiting device will be employed:-ATS/star delta starter oil immersed fully automatic to be installed between bus bar chamber & motor.Shunt capacitor is also proposed to be installed for improving the power factor at site. NOTE :- Star delta starter upto 37.5 KW. ATS between 37.5 KW to 50 KW & Stator rotor starter with slip ring motor beyond 50 KW. (ix) Motor whether squirrel cage or slipring:- Squirrel cage/slipring. Note :- Squirrel cage upto 65HP and slipring above 65 HP. (x) Details of shaft extension reqd:- Just sufficient to provide direct drive by flexible coupling to pump.
(xi) Type of slip ring gear whether continously rated or for starting puposes only & whether to be fitted with brush lifting or short circuiting arrangements or both if interlocks are required.:-Continously rated for squirrel cage/ slipring motor. (xii) Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in curcuit:- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.(xiii) Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated & No. of starts during a specified period:- To work the pumps offered. (xiv) Where possible fault capacity of the systemto which the motor is connected:- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent defomations.
(D). PUMP (BIS 1520-1980) read with BIS 9137-1978 both latest with upto date ammendemnts :- (i) Nos of pumps reqd:- 1 Nos. working pumps & 1 No. stand bye. (ii) Spare parts required:- For two years normal maintenance as recommended by manufacturer. (iii) Optional fittings reqd:- Air cock for exahausting air from each stage.
(E).PUMP OPERATING CONDITIONS :- (i) Capacity:- 5.18 LPS. (ii) Total head in Mts.:- 500.52 mtrs. (If total head is not known then follwing details be provided :- a) static Head: 479 mtrs, (b) Ground level mex. Water level: 1077 mtrs. (c) Ground level to delivery point: 1556 mtrs. (d) Length of Rising main: 2000 mtrs.) (iii) Dia of R/main: 100mm. (iv) Drive arrangement:Direct through flexible coupling on a common base plate.(v) Drive type:-Electric driven. (vi) NPSH reqd:-To be quoted by the tenderer. (vii) Limits of total head in which the pump is reqd. to operate:-(-) 25% to (+) 10% of total head. (viii) Suction/delivery size of pump:-To be specified by the tenderer. (ix) Efficiency of pump at a) duty head,b) (+) 10% head,c) (-) 25 % head:-To be specified by the tenderer. (x) Material of construction:-To be specified by the tenderer (Manufacturer certificate to be appended).
Suply of suitable oil immeresd Star Delta Starter/ATS/stator Rotor Starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release with initial oil filling. Note:- Star- delta - starter upto 37.5 KW. ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50KW.
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltge difference.
Change over switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable cacpacity.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 104 Kg/cm^² ASA 600 NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirlosker/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pas arrangement & size equal to delivery of Pump for withstanding nominal seat pressure of 104Kg/cm^ ²ASA 600. NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Glad/Bhel/Leader of suitable size Cast Iron/Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 104 Kg/cm^² NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast iron flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with upto date ammendments.
P/L suitable size copper pVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) - 1988 or latest with upto date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phase) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipe or trenches under floor. The type size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Providing laying suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part-I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipes, solder, nuts & bolts, cable gland sets. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
Providing/Laying suction, delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure indicated in item No. 1e(ii). Note :- Actual laying to be done as per final drawings to be approved by the Engineer-in-Charge.
Errection of all equipments i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
3rd Stage:- Providing of horizontal spindle, horizontal/ redial split casing/end suction (backpull out arrangement) Single/double/Multistage centrifugal pumps or combination of pumps, in series /parallel of recommended make such as KSB/Mather & Platt/Kirloskar/ Beaconweir/ BE/ Grundfos pump/LUBI pump as per BiS 1520-1980 with upto date ammendments) read with IS 9137- 1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze impellers/ priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade with cast iron casing coupled directely through a flexible coupling on a common CI /cast steel base plate (base plate to be from the menufactourer of the pumping unit only) to slip ring/ squirrel cage screen protceted drip proof induction motor/ motors of standard make such as Kirlokar/ BHEL/ NGEF/GEC/Crompton/ Siemen/ Marthon/ ABB and suitable for operation on 415(+/-) 5% volts, 50 cycles/ second, 3 phase AC electric supply. The power of electric motor/ motors should be at lease +15% in excess of the maximum power required by the pump/ pumps in the operation range of (+) 10% and (-) 15% of the duty point head. The motor/motors as per IS: 325-1978 with upto date ammendments read with IS 1900-1972. It should include cost of bearing nuts, bolts and painting etc. and should meet the following requirements:-
(A).SITE CONDITION :- (i) Location of Site :- Near Village Bag (ii) The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mt :-1556 Mtrs (iii)Humidity:- Weather generally remains humid during monsoon Season. (iv) Nature of Atmosphare:-As normally encountered in Shivalik Range. (v) Detail of quality of water:-Clear cold water. (vi) Water free from sand or not:- Yes. (vii) Water corosive or not:-Not. (viii) Turbidity (if any):-Clear Cold WATER. (ix) NPSH available:-8.994 Mts. (x) Any other information or requirement.
(B). OPERATING CONDITIONS :- (i) Type of current:-AC three/single phase. (ii) Operating frequency:- 50 HZ. (iii) Rated voltage:-400 (+/-) 10% volts. (iv) System of earthing if any to be adopted:-Double loop earthing as per BIS 3043-1987 latest with upto date ammendments. (v) No. of working hours per day :- 8 hours. (vi) Speed of revolution in RPM:- To be quoted by tenderer. (vii) Direction of rotation:-To be quoted by tenderer. (viii) The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.:- 25 degree centigrade.
(C). MOTOR :- (i) Ref to BIS code:-BIS 325- 1978 read with BIS 900-1992 (latest) with upto date ammendments. (ii) Type of enclosure of motor:-SPDP (as per BIS 4691-1985 (Latest). (iii) Type of duty:-Continuous. (iv) Mechanical out put in KW:-suitable for driving centrifugal pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. (v) Class of insulation:-Class- B. (vi) Max. permissible temp. rise of motor reqd. if different from given in B (viii) above. (vii) Particulars of test reqd. & where they are to be conducted:-As per terms & conditions. (viii) Particulars as to whether voltage limiting device will be employed:-ATS/star delta starter oil immersed fully automatic to be installed between bus bar chamber & motor.Shunt capacitor is also proposed to be installed for improving the power factor at site. NOTE :- Star delta starter upto 37.5 KW. ATS between 37.5 KW to 50 KW & Stator rotor starter with slip ring motor beyond 50 KW. (ix) Motor whether squirrel cage or slipring:- Squirrel cage/slipring. Note :- Squirrel cage upto 65HP and slipring above 65 HP. (x) Details of shaft extension reqd:- Just sufficient to provide direct drive by flexible coupling to pump.
(xi) Type of slip ring gear whether continously rated or for starting puposes only & whether to be fitted with brush lifting or short circuiting arrangements or both if interlocks are required.:-Continously rated for squirrel cage/ slipring motor. (xii) Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in curcuit:- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.(xiii) Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated & No. of starts during a specified period:- To work the pumps offered. (xiv) Where possible fault capacity of the systemto which the motor is connected:- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent defomations.
(D). PUMP (BIS 1520-1980) read with BIS 9137-1978 both latest with upto date ammendemnts :- (i) Nos of pumps reqd:- 1 Nos. working pumps & 1 No. stand bye. (ii) Spare parts required:- For two years normal maintenance as recommended by manufacturer. (iii) Optional fittings reqd:- Air cock for exahausting air from each stage.
(E).PUMP OPERATING CONDITIONS :- (i) Capacity:- 5.18 LPS. (ii) Total head in Mts.:- 534.71 mtrs. (If total head is not known then follwing details be provided :- a) static Head: 518 mtrs, (b) Ground level mex. Water level: 1556 mtrs. (c) Ground level to delivery point: 2074 mtrs. (d) Length of Rising main: 1500 mtrs.) (iii) Dia of R/main: 100mm. (iv) Drive arrangement:Direct through flexible coupling on a common base plate.(v) Drive type:-Electric driven. (vi) NPSH reqd:-To be quoted by the tenderer. (vii) Limits of total head in which the pump is reqd. to operate:-(-) 25% to (+) 10% of total head. (viii) Suction/delivery size of pump:-To be specified by the tenderer. (ix) Efficiency of pump at a) duty head,b) (+) 10% head,c) (-) 25 % head:-To be specified by the tenderer. (x) Material of construction:-To be specified by the tenderer (Manufacturer certificate to be appended).
Suply of suitable oil immeresd Star Delta Starter/ATS/stator Rotor Starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release with initial oil filling. Note:- Star- delta - starter upto 37.5 KW. ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50KW.
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltge difference.
Change over switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable cacpacity.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 104 Kg/cm^² ASA 600 NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirlosker/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pas arrangement & size equal to delivery of Pump for withstanding nominal seat pressure of 104Kg/cm^ ²ASA 600. NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Glad/Bhel/Leader of suitable size Cast Iron/Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 104 Kg/cm^² NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Glad/BHEL/Leader/of reputed make of suitable size cast iron flanged sluice valve confirming to IS 780, size equal to dia of suction pipe PN 1 Provided with hand wheel/Cast iron Cap.
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast iron flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with upto date ammendments.
P/L suitable size copper pVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) - 1988 or latest with upto date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phase) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipe or trenches under floor. The type size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Providing laying suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part-I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipes, solder, nuts & bolts, cable gland sets. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
Providing/Laying suction, delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure indicated in item No. 1e(ii). Note :- Actual laying to be done as per final drawings to be approved by the Engineer-in-Charge.
Errection of all equipments i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
HYDRAULIC ENGINEERING COMPANY
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .