Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAdmitted-Finance TAKANA COLONY PITHORAGARH UTTARAKHAND | PITHORAGARH | UTTARAKHAND | 262501 | ₹40.8 L | L1 | Admitted-Finance |
| 2 | L2₹40.9 LAdmitted-Finance | ₹40.9 L | L2 | Admitted-Finance |
| 3 | L3₹40.9 LAdmitted-Finance | ₹40.9 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Garg Construction L3 | AR ENTERPRISES L2 | MANISH CHAUDHARY M/S OM SAI ENTERPRISES 48 JAGDAMBA COLONY PITHORAGARH UTTARAKHAND L1 |
|---|---|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C | 244 | Point | 1,559.86 ₹3.8 L | 1,559 ₹3.8 L | 1,558 ₹3.8 L |
| 2.00 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. | 280 | Rm | 355.14 ₹99,439.20 | 355 ₹99,400 | 354 ₹99,120 |
| 3.00 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 100 | Rm | 570.99 ₹57,099 | 570 ₹57,000 | 569 ₹56,900 |
| 4.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 633 | Rm | 247.75 ₹1.6 L | 247 ₹1.6 L | 246 ₹1.6 L |
| 5.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Circuit Wiring & Light Plug Wiring) | 1,139 | Rm | 292.41 ₹3.3 L | 292 ₹3.3 L | 291 ₹3.3 L |
| 6.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm (For Single Phase DB. From Sub Panel to DB) | 25 | Rm | 466.79 ₹11,669.75 | 466.79 ₹11,669.75 | 465 ₹11,625 |
| 7.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm (For Three Phase DB. From Sub Panel to DB) | 227 | Rm | 1,068.62 ₹2.4 L | 1,068.62 ₹2.4 L | 1,067 ₹2.4 L |
| 8.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 16 sq. mm (For Three Phase DB. From Sub Panel to DB) | 202 | Rm | 1,451.4 ₹2.9 L | 1,451.4 ₹2.9 L | 1,450 ₹2.9 L |
| 9.00 | Supplying and fixing following Modular base & cover plate one existing modular metal boxes etc. as required 6 Module | 28 | Each | 193.52 ₹5,418.56 | 193.52 ₹5,418.56 | 192 ₹5,376 |
| 10.00 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch | 28 | Each | 109.52 ₹3,066.56 | 109.52 ₹3,066.56 | 108 ₹3,024 |
Tender Value
₹40.9 L
EMD Value
₹82,000
Closing Date
17 Feb 2026, 3:00 pmClosed
DGM HQ BRIDCUL
BRIDCUL Opp Govt ITI Niranjanpur Saharanpur Road Dehradun
Internal Electrification and Allied works for Examination Hall at Govt. Degree College, Halduchaur, Distt. Nainital.
2026_BRID3_91682_1
231/BRIDCUL/1030/26 Dated 02.02.2026
Open Tender
Electrical Works
365 days
Nainital
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
MD - BRIDCUL
₹82,000
BRIDCUL Dehradun
17 Mar 2026
5 Feb 2026
17 Feb 2026
5 Feb 2026
17 Feb 2026
11 Feb 2026
10 Feb 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Circuit Wiring & Light Plug Wiring)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm (For Single Phase DB. From Sub Panel to DB)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm (For Three Phase DB. From Sub Panel to DB)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 16 sq. mm (For Three Phase DB. From Sub Panel to DB)
Supplying and fixing following Modular base & cover plate one existing modular metal boxes etc. as required 6 Module
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 15/16 A Switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 6 pin 15/16 A Socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, Unarmored Telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Extra for Fixing the Louvers/ Shutters Complete with Frame for a Exhaust Fan of all sizes.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
Supplying and Fixing Following way, Horizontal Type Three Pole and Neutral, Sheet Steel, MCB Distribution Board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 Way (4 + 18), Double Door
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 95 sq. mm (38mm)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 225 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 225 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 225 mm width X 50 mm depth X 1.6 mm thickness
Design, manufacture, supply, installation, testing and commissioning of Floor Mounting Distribution Panel cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid. INCOMER : 150 AMP with Changeover swaitch of 150 amp BUS BAR : 150 AMP, 440 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm/amp. The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient Temperature. OUT GOINGS : 2 No 40 AMP 4P MCCB (Light DB GF), 2 No 40 AMP 4P MCCB (Light DB FF) 2 No 63 AMP 4P MCCB (Power DB GF & UPS I/P) 1 No 63 AMP 4P MCCB (Power DB FF) 4 No 63 AMP 4P MCB (Spare) Complete panel as above and complete
Providing and Supplying of LED Batten 20 Watts 1150 mm Complete in all respect.
Providing and Supplying of Surface/recess type LED Panel 2x2 36 Watts Complete in all respect.
Providing and Supplying of 9W Led Bulb With Battery-Is:16102, Warranty for free replacement 1 year Complete in all respect.
Providing and Supplying of 12W Warm White Ceramic Circular LED Surface/ recess Ceiling Light Complete in all respect.
Providing and Supplying of Aluminium Wall Fan 2 year Warranty Complete in all respect.
Providing and Supplying of Exhaust Fan 300 mm Complete in all respect.
Providing and Supplying of 2 Ton 5 Star, Inverter AC Wall Mount Split AC Complete in all respect.
Supply of 10KVA/ 10KW True Online , DSP Controlled , double conversion online UPS with 3 phase AC input and 3 phase AC output with 30min backup on 12V SMF batteries Bank with Rack ( min. VAH required =10080 VAH ) ,The UPS should be with IGBT Based Rectifier and IGBT based Inverter and with LCD/LED display for monitoring of its status along with same OEM Make inbuilt Galvanic Isolation Transformer . UPS should have inbuilt phase sequence corrector and dust filters, SNMP card & parallel kit. True Online Double Conversion with IGBT Based Rectifier & IGBT Based Inverter Technology Input Voltage window 330 VAC - 475 VAC Input Frequency window 45-55 Hz Nominal Frequency 50 Hz Total Harmonic Current Distortion (THDI ) should be less than 5 % at full rated load Input power factor (pf) greater than or equal to 0.99, Bypass Frequency range (+/- 10%) Output Power Factor should not less than 0.9 Output Power Capacity in watts (KW) 10KVA / 10KW Output Voltage - 400 /415 Volts rms, adjustable via the user interface. Total Harmonic Distortion : < 2% for linear load & <5% for 100% non-linear load Output Frequency range 50/60 HZ. Minimum 93% without isolation 60 minutes at a load representing 110 % , 10 minutes at a load representing 125% , 60 second at a load representing 150% Parallel option upto 4 Units should be available UPS Should Be built in Manual and Maintenance Bypass One Year on UPS Two years on UPS with onsite service Support 40 degree C Less than 70 dBA Min. VAH for bank required =10080 VAH.Battery Type DC Voltage Bus ( 192-240) VDC . UPS Should Work Flexible on 192 - 240 batteries.Common battery bank configuration is require upto 2 UPS. Complete in all respect
Supply, installation, testing and commissioning of IP Camera Indoor 4MP with RJ 45 connector/jack. Complete in all respect
Supply, installation, testing and commissioning of IP Camera Outdoor 4MP with RJ 45 connector/jack. Complete in all respect
Supply, installation, testing and commissioning of NVR 32 channel complete with all respect accessories and suitable for minimum 8 slot harddisk. Complete in all respect
Supply, installation, testing and commissioning of hard disk 4TB per NVR. Complete in all respect
Supply, installation, testing and commissioning of Switch 16 port POE. Complete in all respect
Supply, installation, testing and commissioning of Back Box. Complete in all respect
Supply, installation, testing and commissioning of 48" LED Screen for Observation and reviewing. Complete in all respect
Supply and fixing of 2 meter patch cord with complete connectors. Complete in all respect
Supply, installation, testing and commissioning of 9U RACK with PDU and respected accessories.Complete in all respect
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
BOQ_108601.xls
BOQ • 0.31 MB
sbdinternalexaminationhallhalduchaurf.pdf
Tender Documents • 1.80 MB
Download all tender documents and submit your bid