| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC M/S The Home Plus is the Lowest Bidder, hence accepted | |
| 2 | L2₹27.0 L+₹2.7 L (11.0%)Rejected-Finance | L2 | Rejected-Finance M/S is the Lowest Bidder, hence accepted | |
| 3 | L3₹41.9 L+₹17.6 L (72.5%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L3 | Rejected-Finance M/S is the Lowest Bidder, hence accepted | |
| 4 | Rejected-Technical PACHPADRA ROAD OPP MILK DAIRY BALOTRA TEHSIL PACHPADRA DISTT BALOTRA RAJ | GANGANAGAR | RAJASTHAN | 335001 | - | Rejected-Technical Not enlisted in appropriate category |
| Sl No | Description | Qty | Unit | KRISHNA CONSTRUCTION COMPANY L3 | L C ASSOCIATES L2 | The Home Plus L1 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for cleaning and desilting of RCC over head tank Capacity 0.50 Lakh Gallons of any depth by pumping out /removing liquid waste/sewage with, removing silt, sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements, face mask etc and removing the same (silt, sludge & other waste material) in leak proof trucks covered with tarpoline to outside of MD land all as per existing rules and regulations of civil authorities and flushing the tank with fresh water etc complete all as specified and directed.
Note :- (a) Cleaning and desiliting of RCC over head tank shall be carried in following stages as under :-
Stage-I :- Dewatering the tank with portable submerssible pump set flowable of 30000 Ltrs/Hrs.
Stage-II :- Desilting and removal of left over dirty water and sludge with a special sludge removal pump.
Stage-III :- Cleaning of wall, ceiling and floor by high pressure water jet with the help of German equipments which creates pressure of 80-120 bar.
Stage-IV :- Removal of remaining sludge from the floor with the help of high pressured industrial vacuum cleaner.
Stage-V :- Spraying of bio degradable, eco friendly antibactirial agent certified by NTC a government approved lab to disinfect the tank from all harmful pathogens. The doze utilized for safe as per the OECD Guidelines 423 adopted is as on 17 Dec 2001.
Stage-VI :-Treatment of inside tank by exposing UV radiation to kill to further suspended or floating bacteria, write cleaning of tanks date with black enemel paint on white background.
Stage-VII :- Removal of remaining sludge from the floor with the help of high pressured industrial vacuum cleaner.
(b) All necessary equipment of machinery, T & P, transportation etc shall be arranged by contractor and quoted rate shall be deemed to included of the same. | 3 | EACH JOB | 5,000 ₹15,000 | 4,000 ₹12,000 Lowest | 1,00,000 ₹3,00,000 |
| 2.00 | All as per Item No 1.00 above but RCC over head tank capacity 1.0 Lac Gallons complete all as specified and directed. | 1 | EACH JOB | 7,000 ₹7,000 | 4,500 ₹4,500 Lowest | 80,000 ₹80,000 |
| 3.00 | All as per item No 1.00 above but RCC covered Under Ground Sump (0.50 Lac Gallon Capacity) static water tank complete all as specified and directed. | 2 | EACH JOB | 10,000 ₹20,000 | 3,800 ₹7,600 Lowest | 50,000 ₹1,00,000 |
| 4.00 | All as per item No 1.00 above but RCC covered Under Ground Sump (1.0 Lac Gallon Capacity) static water tank complete all as specified and directed. | 1 | EACH JOB | 12,000 ₹12,000 | 4,500 ₹4,500 Lowest | 90,000 ₹90,000 |
| 5.00 | All as per item No 1.00 above but RCC covered Under Ground Clear Water Sump (5.0 Lac Gallon Capacity) static water tank complete all as specified and directed. | 1 | EACH JOB | 20,000 ₹20,000 | 16,000 ₹16,000 Lowest | 75,000 ₹75,000 |
| 6.00 | All as per item No 1.00 above but RCC covered Under Ground Sump (27.50 Lac Gallon Capacity) static water tank complete all as specified and directed. | 1 | EACH JOB | 2,75,000 ₹2,75,000 | 1,20,000 ₹1,20,000 Lowest | 2,25,000 ₹2,25,000 |
| 7.00 | All as per item No 1.00 above but RCC covered Under Ground Sludge tank (0.50 Lac Gallon Capacity) static water tank complete all as specified and directed. | 2 | EACH JOB | 10,000 ₹20,000 | 4,000 ₹8,000 Lowest | 75,000 ₹1,50,000 |
| 8.00 | All as per item No 1.00 above but RCC covered Under Ground Sum (25000 Gallon Capacity) static water tank complete all as specified and directed. | 2 | EACH JOB | 15,000 ₹30,000 | 3,500 ₹7,000 Lowest | 22,500 ₹45,000 |
| 9.00 | All as per item No 1.00 above but PVC water tank 5000 ltr capacity complete all as specified and directed. | 3 | EACH JOB | 2,000 ₹6,000 | 800 ₹2,400 Lowest | 40,000 ₹1,20,000 |
| 10.00 | All as per item No 1.00 above but PVC water tank 10000 ltr capacity complete all as specified and directed. | 1 | EACH JOB | 4,000 ₹4,000 | 1,000 ₹1,000 Lowest | 80,000 ₹80,000 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
14 Oct 2025, 6:00 pmClosed
Sh Nitish Pathak, EE
GE (AF) Phalodi PIN-342301
CLEANING AND MAINTENANCE OF OH TANK, UNDER GROUND SUMP AND CONNECTED WORKS AT TECH AREA AND DOMESTIC AREA AT AFS PHALODI.
2025_MES_731250_1
8724/A/E8
Open Tender
Civil Works
Item Rate
180 days
Air Force Stn Phalodi
As per Tender Documents.
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹64,000
Yes
10 Dec 2025
16 Sept 2025
21 Oct 2025
16 Sept 2025
14 Oct 2025
30 Sept 2025
Amount
M&L for cleaning and desilting of RCC over head tank Capacity 0.50 Lakh Gallons of any depth by pumping out /removing liquid waste/sewage with, removing silt, sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements, face mask etc and removing the same (silt, sludge & other waste material) in leak proof trucks covered with tarpoline to outside of MD land all as per existing rules and regulations of civil authorities and flushing the tank with fresh water etc complete all as specified and directed. Note :- (a) Cleaning and desiliting of RCC over head tank shall be carried in following stages as under :- Stage-I :- Dewatering the tank with portable submerssible pump set flowable of 30000 Ltrs/Hrs. Stage-II :- Desilting and removal of left over dirty water and sludge with a special sludge removal pump. Stage-III :- Cleaning of wall, ceiling and floor by high pressure water jet with the help of German equipments which creates pressure of 80-120 bar. Stage-IV :- Removal of remaining sludge from the floor with the help of high pressured industrial vacuum cleaner. Stage-V :- Spraying of bio degradable, eco friendly antibactirial agent certified by NTC a government approved lab to disinfect the tank from all harmful pathogens. The doze utilized for safe as per the OECD Guidelines 423 adopted is as on 17 Dec 2001. Stage-VI :-Treatment of inside tank by exposing UV radiation to kill to further suspended or floating bacteria, write cleaning of tanks date with black enemel paint on white background. Stage-VII :- Removal of remaining sludge from the floor with the help of high pressured industrial vacuum cleaner. (b) All necessary equipment of machinery, T & P, transportation etc shall be arranged by contractor and quoted rate shall be deemed to included of the same.
All as per Item No 1.00 above but RCC over head tank capacity 1.0 Lac Gallons complete all as specified and directed.
All as per item No 1.00 above but RCC covered Under Ground Sump (0.50 Lac Gallon Capacity) static water tank complete all as specified and directed.
All as per item No 1.00 above but RCC covered Under Ground Sump (1.0 Lac Gallon Capacity) static water tank complete all as specified and directed.
All as per item No 1.00 above but RCC covered Under Ground Clear Water Sump (5.0 Lac Gallon Capacity) static water tank complete all as specified and directed.
All as per item No 1.00 above but RCC covered Under Ground Sump (27.50 Lac Gallon Capacity) static water tank complete all as specified and directed.
All as per item No 1.00 above but RCC covered Under Ground Sludge tank (0.50 Lac Gallon Capacity) static water tank complete all as specified and directed.
All as per item No 1.00 above but RCC covered Under Ground Sum (25000 Gallon Capacity) static water tank complete all as specified and directed.
All as per item No 1.00 above but PVC water tank 5000 ltr capacity complete all as specified and directed.
All as per item No 1.00 above but PVC water tank 10000 ltr capacity complete all as specified and directed.
S & F in renewal of automatic star delta Submersible motor starter in steel sheet enclosure AC 3 phase, 415 Volts, 50 Hz type MUG with single phase preventer, dry run preventer, overload protection, reverese phase protection suitable for 40 HP submersible pump set (Contactor rating minimum 65 Amps, Overload Relay Range minimum 34 to 50 Amps) complete all as specified and directed.
Material & labour for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burred in ground vertically earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of GI nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate upto 5 mtr and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 using 20mm stone aggregates for earthing pit, 10mm thick cast iron cover with angle iron frame and shown in electrical plate No 3 of SSR Part-I and testing on complete including dismantling old earthing all as specified and directed. Note: (i) Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc complete all as specified and directed. (ii) The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level.
S & F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
Supply and fixing Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
M & L Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
S & F aviation LED obstraction lamp with aluminium die castingand polycarbonate red dome 7 w, 230 volt , 360 degree viewing angle IP 65 rating complete all as specified and directed.
S & F PVC insulated unsheathed copper conductor cable 1.5 sqmm three core multistranded,PVC round sheathed FRLSH electric cable, 1100 volts grade complete all as specified and directed.
Supply and fixing SPN DB 4 way double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting SPN, 240 Volt complete all as specified and directed.
Supply and fixing MCB SPN 16 Amp 'B' curve, 240 Volt complete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area 6 Sqmm 2 core and laid in trenches / duct / fixing on panels /walls /poles or passing through pipe including connecting with suitable lugs, thimble ,glands, nuts and bolts complete including taking out the old burnt out cables any size or type complete all as specifed & directed. Note: (i) LT Cable joint , Lugs, Thimble, Gland, Nut & bolts shall be included in quoted item rate.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area 50 Sqmm 3.5 core and laid in trenches / duct / fixing on panels /walls /poles or passing through pipe including connecting with suitable lugs, thimble ,glands, nuts and bolts complete including taking out the old burnt out cables any size or type complete all as specifed & directed. Note: (i) LT Cable joint , Lugs, Thimble, Gland, Nut & bolts shall be included in quoted item rate.
Taking out existing rapid gravity filter media (sand and gravels) and cleaning to tank by jet pressure pump, remove sludge from tank complete all as specified and directed. Note :- Waste material remove from site and site clearence is responsibility of Contractor.
Taking out existing filter media of sludge drying bed and cleaning to tank remove sand and mud complete all as specified and directed. Note :- Waste material remove from site and site clearence is responsibility of contractor.
Taking out existing tube settler filter media (pvc cool tube ,loose leaves) including cleaning of tank wall tiles using anti scaling chamical, remove mud sludge and wash complete tank by using jet pressure pump complete all as specified and directed. Note :- Waste material remove from site and site clearence is responsibility of contractor.
M & L for cleaning to mixing chamber of size 10 x 2.6 x 1.83 mtr rubing,scraping and removing sludge from tank and washing after cleaning apply two coat of white wash on tank walls complete all as specified and directed. Note :- waste material remove from site and site clearence is responsibility of cotractor.
Supply and placing of rapid gravity filter media with new sand at 750 mm thick of size 0.45 mm to 0.70 mm gravels as depth of layers complete all as specified and directed. Note :- The test certificate of rapid gravity sand filter will be provided by the contractor from nearest PHED lab.
Supply, installation and testing of filter media for sludge drying bed remove complete existing sand bed and fill the new sand (in two layer of each 200 mm thickness) of size 0.8mm to 3mm and gravels in 100 mm thick of size 3mm to 6mm as complete all as specified and directed. Note :- The test certificate of sand will be provided by the contractor from nearest PHED lab.
Supply, installation and testing PVC cool tube media ,loose leaves of size 11 m2/m3 to 60 deg angle inclination , vertical height 1000mm as per existing complete all as specified and directed.
S & F copper cable size 0.5 sqmm PVC insulated multistranded 12 core control cable for water level indicator complete all as specified and directed.
M & L for Stairs (framed) including ,steps , treades, landing, balusters, hand rails etc. including cleats, brackets, etc. with necessary drilling, fastening, welding work and fixing material required included in quoted rate (Fe-290 Gde E-165) complete all as specified and directed. Note:- Stair will be fixed inside the tank over the height approx 15 to 20mtr .
M & L for Complete removal of existing treatment on external wall surface of any type of over head reservoir upto 25 mtr height and applying two coat of weather proof paint over a coat of primer including crack filling with epoxy or polyurethene foam complete all as specified and directed.
M & L for Complete removal of existing treatment on internal wall surface of any type of over head reservoir upto 25 mtr height and applying two coat of epoxy coating over a coat of primer as per manufacturers instruction with and including necessary scaffolding arrengment for carry out the work complete all as specified and directed. (Note : The work will to be carried out by authorised applicator).
L C ASSOCIATES (BID ID -3450216)
KRISHNA CONSTRUCTION COMPANY (BID ID -3442954)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .