GE I NAVY JAMNAGAR
INS VALSURA JAMNAGAR 361150
PROVISION OF LIFT AND GALLERY FOR BLDG No P 235 AT INS VALSURA JAMNAGAR
2022_MES_502207_1
8568
Open Tender
Miscellaneous Works
Item Rate
120 days
GE I NAVY JAMNAGAR
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹64,900
Yes
4 Aug 2022
18 Jan 2022
7 Feb 2022
18 Jan 2022
5 Feb 2022
24 Jan 2022
18 Jan 2022 - 24 Jan 2022
60 days
Amount
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MD land complete all as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MD land complete all as directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick (above or below ground level) complete all as specified and directed.
Demolition of cement reinforced concrete of any descritpion and in any position not otherwise specifically provided for complete all as specified and direacted
Excavation over areas n.exc 1.5m deep and getting out soft/ lose soil complete all as directed.
Excavation over areas exc 1.5m and n exc 3.0 deep and getting out soft/ disintergrated rock complete all as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of pipe line etc and getting out in any type of soil (i.e.soft/ loose or hard/ dense soil) complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance exceeding 250m but not exceeding 500m and depositing where directed at a level n. exc. 1.50m above the starting point.
M&L for PCC 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in foundation filling, mass concrete complete all as specified and directed
M&L pre-cast PCC 1:3:6 type C1 (using 20 mm graded granite aggregate) as in block masonry with factory made solid blocks, exceeding 10 cm in width and setting in CM 1:4 complete all as specified.
M&L for RCC M-30 (using 20 mm graded granite stone aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams, base of columns etc and the like complete. Note: Reinforcement shall be measured and paid separately.
M&L for RCC M-30 (using 20 mm graded crushed granite stone aggregate) as in Walls, retaining walls, basement walls, ballast walls (upto 8m height) and the like; any thickness; above top of footings; including attached pilasters and buttresses. Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, canopies, deck slab etc complete all as directed. Note: Reinforcement shall be measured and paid separately.
Supply only Integral Water Proofing Compound (ISI Marked) of Make : CICO, Acco Proof, Impermo, Aqua flex as approved.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or batter, flat rough finished surface all as specified.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. vertical or to batter for flat fair finished surface complete all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping), flat rough finished surface all as specified.
S&F rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming to Fe410-W Gde E-250 quality A.
S & F 10 mm dia and over TMT bars cut to length bent to shape required cranking including bending , hooking ends etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No. 19 here-in-above but 6 to 8mm dia bar - do -
All as per item No. 19 here-in-above but 5 mm dia and over upto 10 mm dia as in stirrups
M&L for rendering 15 mm thick in cement mortar 1:4 on brick/ block masonry surfaces other than fair faces of brick work mixed with WPC as per manufacturer instruction, and finished the surface fair and even complete all as specified and directed. (Note : WPC measured and paid separately).
M&L for rendering 15 mm thick in cement mortar 1:3 on fair faces of brik work or concrete surfaces mixed with WPC as per manufacturer instruction, and finished the surface fair and even complete all as specified and directed. (Note : WPC measured and paid separately).
M&L for rendering 10 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified.
M&L for rendering 5 mm thick in CM 1:3 on ceiling surfaces fair faces of brick work or concrete surfaces finished fair and even complete all as specified.
M&L for three coats of white wash on newly plastered surface of ceiling after necessary preparation of surface complete all as directed.
M&L for preparing newly plastered or unplastered surfaces of walls and applying two coats of plastic emulsion paint over a coat of primer over a coat of 3mm thick white cement based wall care putty complete all as specified.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth.
M&L for acrylic polymer modified cemetatious waterproofing treatment to bottom, sides of lift pit and roof using Nitocote CM of fosroc or equivalent of 2mm thick complete as per manufacturer instructions.
E&M WORKS: M&L for point wiring with 1100 V, 1.5 Sqmm single core PVC FRLS insulated unsheathed cable, copper conductor multistranded passing through including PVC conduit 20mm, MS box/ PVC/ MS/ Cast Iron box and logic modular whtie plates of suitable as required at site with PVC insulated unsheathed stranded copper of size 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting and making good surface of walls applying suitable painting as required all as directed. NOTE: (i) Switch and socket to be measured and paid for separately.
All as per item No.31 here-in-above, but for 6 Amp (2/3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
S&F switch modular type single pole one way 6 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 01 or equivalent in Philips / Crabtree / ABB / Havells
S&F socket outlet 2/3 Pin 6 Amp modular type all accessories complete all as directed. Make: Legrand Cat No. 6755 52 or equivalent in Philips / Crabtree / ABB / Havells
S&F Ceiling rose surface bakelite White / Ivory / Urea finish 50 mm dia three terminals including supply and fix PVC square mounting block complete all as specified and directed.
S&F 20 Watt 4 ft Batten surface and wall mounted LED batten with aluminium housing & integrated electronic driver fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Havells Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivalent of Bajaj/ Crompton/ Philips /Wipro.
S&F MCCB DB's VTPN type double door in wall/ nitch when MCBB's to be used Four pole and neutral, 4 way, 415 Volt with rated Bus bar, suitable for Flush Mounting and Surface Mounting with 160 Amps Copper Bus bar for each phase and 2 Neutral bar, 2 Earth bar and Cable ties for cable managent, Fully insulated busbar and shrouded Neutral bar, improved Pan assembly for ease of installation, Prefitted masking sheet, Reversible Door for IP 43 & IP 54 DB's with provision for DPX3 160 MCCB as incomer, and TPN/ SPN/ DP/ SP outgoing complete all as specified and directed. IP:54 Protection. Make: Legrand Cat part No. 5077 50 Modules No. DPX3 160+12 or equivalent in Indo Asian/ Standard/ L&T
S&F one way sheet metal enclosure fixed in wall/ Nitch when MCCB's to be used triple pole and neutral 415 Volt complete all as specified and directed. Make: Legrand Cat No. 5078 01 or equivalent in Havells/ L&T/ Indo Asian/ Standard (for 160 Amp MCCB)
S&F MCCB 160 Amp, 4 pole, 415 V with adjustable thermal and magnetic setting of breaking capacity 25 kA complete all as specified and as directed. (for tapping from existing panel)
S&F MCB TPN 63 Amp, 415 V, 50 Hz, 10 kA suitable for lighting and other domestic load rating C-Series complete all as specificed and directed. Make: Legrand Cat No. 4086 80 or equivalent of Havells/ L&T/ ABB (for lift)
S&F MCB SP 6 Amp, 240 V, 50 Hz, 10 KA suitable for lighting and other domestic load rating C-Series complete all as specified and as directed. Make: Legrand Cat No. 4085 87 or equivalent of Havells / L&T / ABB (for light & fan point)
Supply and lay cable in trenches or fixing on wall or pole XLPE cable insulated screened PVC beded GI steel strip or wire armoured electric power cable (heavy duty) with standard aluminium conductor 1100 volt grade cross sectional area 35 Sqmm 3.5 core making necessary connection & testing on completion all as directed.
S&F 50 mm bore high density polyethylene pipes ISI Marked (HDPE) of pressure rating 6 kgf/cm2 for protection of cable in trenches complete as specified.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point complete all as specified including testing on completion. (for VTP DB & Lift)
Item No. 45.00 Contd/-- The following technical features of 6 persons pasanger lift as under : 1. ACVVVF closed loop drive 2. Alarm button in car operating panel with battery back-up 3. Automatic operation for car fan 4. Adjustable door open time 5. Anti-nuisance (empty car) 6. Anti-nuisance (car call cancellation at direction reversal) 7. Blower fan in car for ventilation 8. Braille on push buttons 9. Car call cancellation by double pressing floor button in car operation panel 10. Door open and door close buttons in car operating panel 11. Door closing retries 12. Door nudging 13. Emergency light 14. Full load by-pass 15. Home landing 16. Infra-red screen for car door 17. Intercom 18. Jammed landing operating panel call button by-pass 19. Motor overheat protection 20. Overload function with audio-visual indication in car operating panel 21. Phase failure and phase reversal protection
Item No. 45.00 Contd/-- 22. Automatic rescue device in case of power failure 23. Attendant control 24. Car arrival chime on car top 25. Red dot matrix scrolling display in car operating panel 26. Red dot matrix scrolling display in landing operating panel on All Floors 27. Fireman control 28. Fireman emergency return 29. Independent operation (car VIP function) 30. Voice announcement unit in English language in car 31. Car gate lock Safety Note : Rate quoted includes: (a) Obtaining Lift License (including all accessories free and expenses) (b) Obtaining applicable statutory permits and approvals (documents for PWD Approval/ Erection Permission as applicable) before start of Works Permission, as applicable) before start of work. (c) Supply and erection of suitable scaffolding (as per approved GAD) inside elevator shaft/escalator pit for entire installation period and dismantling/ removal of the same after completion of Works. (d) Provn of fixing of separator channels for common shaft if reqd. (e) Supply, installation of shaft reduction channels. (f) Material & labour for safety hooks and lift suspended system as per manufacturer requirements. (g) All accessories of lift & lift instalation & testing shall be all as per IS-14665.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .