| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L1 | Accepted-AOC lowest tenderer | |
| 2 | L2₹18.5 L+₹2.9 L (18.4%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
Tender Value
₹16.8 L
EMD Value
₹33,600
Closing Date
11 Mar 2024, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001 (Punjab)
Special Repair of Bldg No P-19 JCOs Married Accommodation at CG Complex and certain sanctioned works at Dholewal under GE Ludhiana.
2024_MES_641974_1
GE/LDH-64/2023-24
Open Tender
Civil Works
Item Rate
180 days
CG COMPLEX AND DHOLEWAL
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹33,600
Yes
30 Mar 2024
12 Feb 2024
13 Mar 2024
12 Feb 2024
11 Mar 2024
27 Feb 2024
12 Feb 2024 - 26 Feb 2024
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge.
Dismantling brick tiles or terracing tiles, single layers including any treatment on roof complete all as specified and as directed by Engr-in-charge.
Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part there of) and removing from outside of defence land complete all as specified and as directed by Engr-in-charge.
M&L Applying evenly a bitumen tack coat of industrial bitumen 85/25 @ 1.2 kgs/Sqm including cleaning surfacescomplete all as specified and directed by Engr-in-Charge.
M&L Priming surfaces and applying normal treatment (for moderate conditions) using bitumen primer @ .30 Kg/Sqm applied hot complete all as specified and directed by Engr-in-Charge.
M&L providing APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150gms/Sqm) laid on primed surfaces by forced application APP based polymeric membrance complete all as specified and directed by Engineer-in-Charge.
M&L for Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate average thickness 50mm as in roof padding incl mixing water proofing compound or equivalent as per manufacturers instruction complete all as specified and directed by Engr-in-Charge. Note. water proofing material shall be measured and paid seperately)
M & L 40 mm thick brick tiles laid on cement mortar and joints grouted flush in cement mortar ( 1:3 ) mixed with 5% of crude oil by weight of cement on cement mortar complete all as specified and directed by Engr-in-Charge.
All as per Item No. 08 above but except tiles complete all as specified and directed by Engr-in-Charge.
Removing mortar from and cleaning bricks, stacking for measurement including all extra handling and removal and disposing off rubbish complete all as specified and directed by Engr-in-Charge.
Supply only Integral water proofing compound (ISI Marked approved) complete all as specified and directed by Engr-in-Charge.
M&L PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engr-in-Charge.
Dismantling of stone slabs and tiles of any description or thichness in floors aprons etc laid bedded and pointed in any mortar complete all as specified & directed by Engineer-in- charge.
M&L, Granite slab 20 mm thick (table rubbed and polished) as in in steps, jambs,pillars, window-cill, cooking platform over and including 15mm thick bedding layer in cement mortar (1:6) and pointed with white or colour cement (1:2) using marble dust with admixture to match the shade of granite complete all as specified and directed by Engr-in-Charge.
M&L machine cut kota stone 18-22 mm thick as in slab, flooring & tread of steps over and including 15mm thick cement screed bed in cement mortar 1:6 laid and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and grantie polishing complete all as specified and directed by Engr-in-Charge.
All as per item 15 above but in riser of steps, skirting & dado laid over and including 10mm thick cement screed in CM 1:4 complete all as specified and directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing, serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile 0.11 Sqm but n.exc 0.18 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment to match over and including15mm thick screed bed in cement mortar (1:6) complete all as specified and directed by Engr-in-Charge.
All as per item No 18 above but as in skirting over and including rendering 10mm thick in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge.
M&L glazed ceramic coloured/ printed tiles 450mm x 300mm x 7mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick bedding layer in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.
Demolition of brickwork built in cement or cement lime mortar incl all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-Charge.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frames(without taking off shutters from the frame) area n.exc 1.5 Sqm each complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frames exc 1.5 Sqm but n.exc 4.0 Sqm with shutters (without taking off shutters from the frame) complete all as specified and as directed by Engineer –In -Charge
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed by Engineer –In -Charge.
S & F Pre-laminated particle board 18/19mm thick, interior grade, pre laminated one side decorative choice lamination and side balancing white,fixed in frame, complete all as specified and as directed by Engineer –In -Charge.
Taking down shutters of any desciption area exc 1.0 Sqm but n.exc 2.0 Sqm each and refixing in the same opening after easing, minor adjustment and minor repair complete all as specified and directed by Engr-in-Charge.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube suppling & fixing in opening as per specification and drawing complete all as specified and directed by Engr-in-Charge.
S&F factory made soilid panel PVC Door shutter 30mm thick S-Type consisting of frame made out MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail, & bottom rail; Panneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing complete all as specified and directed by Engr-in-Charge.
M&L for Box type steel window/ventilator made of ERW tube P-section of size 60 mm x 25 mm single rebated outer frame wall thickness 1.0mm comprises glazed skelton of ERW tube P-Section size 50mm x 20mm with one/two Nos open able leaf consisting of two Nos Sash bar of T-section 20x3 mm welded to frame with one or no vertical mullion of ERW box type T Section of size 60mm x 25mm and F1 2mm thick welded/screwed to frame for fixing of glass incuding fittings and fixtures like handle, Tower bolt, stopper, Cleat, Pintal Hinges, holdfasts etc complete including cutting holes, making good dismantled portion in PCC 1:2:4 type B-1, all as specified and directed. (a) Holdfast 150mm long of 12mm x 3mm MS flat-04 Nos per window. (b) Handle of Z section 20mm x 25mm, 100mm long-01 Nos per leaf. (c) Z Section stopper 20mm x 25mm, 100mm long-01 Nos per leaf. (d) Cleat 55mm long of hollow square 15mm x 12mm- 02 Nos per leaf. (e) MS pintol hinges size 75mm x 12mm -02 Nos per leaf. (f) one coat of red oxide primer. Note:- MS guard bars, sheet glass, and painting shall be measured and paid seperately.
All as item No 30 but fixing with wire mesh complete all as specified & directed by Engr-in-charge.
S&F mild steel framed work such as guard bars/grills,grating etc with end of bars shouldered and/or riveted or forged into spikes and similar works including one shop coat of zinc chromate primer complete all as specified.
M&L for 3mm thick Sheet glass, ordinary quality and glazing with silicon sealant in square n exc 0.5 sq.m in each pane complete fixed in repair all as specified and directed by Engineer-in-Charge.
Ditto item no 33 but frosted glass of 3 mm thick complete all as specified and as directed by Engr-in-charge.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engineer-in-Charge.
S&F for Pressed steel frames of size 105x60mm sheet thickness 1.25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, tarring back of chowkhats & holdfast etc, complete all as specified and directed by Engineer-in-Charge.
S&F for Pressed steel frames of size 125x60mm sheet thickness 1.25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, tarring back of chowkhats & holdfast etc., complete all as specified and directed by Engineer-in-Charge.
M&L Providing cement concrete type C-0 1:3:6 (12.5 mm graded stone aggregate) as for pressed steel chowkhats complete all as specified and directed by Engr-in-Charge.
M&L for 35mm thick factory made glazed and skeleton shutters,2nd class hardwood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats complete all as specified and directed by Engineer-in-Charge.
S&F of factory made plain framed pannelled door shutters 35mm thick (two layer panel) with lock rail and panel of 9mm BWP commercial ply or 12mm verneering on both faces. The size of rail and stile as per IS-1003, SSR Pt-I kiln seasoned and chemically treated complete all as specified and directed by Engr-in-Charge.
S&F in Aluminium handles, cast type, anodised 150mm long complete all as specified and directed.
S&F 300 mm long ordinary rat tail rod pattern spring incl roller and roller plate complete (Mild steel) complete all as specified & directed by Engr-in-charge.
S&F 100mm size Butt hinges, medium weight, cold rolled mild steel bright finish complete all as specified and directed by Engineer-in-Charge.
S&F 150mm aluminium anodised tower bolts of extruded section fixed with screw, complete all as specified & directed by Engr-in-charge.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolts 200 mm complete all as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue, 140mm size ,anodised, with hard drawn steel spring complete all as specified and directed by Engineer-in-Charge.
M&L framed work as in cooler stand doors or gates of angle or other section drilled for fixing and hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete (Fe410-W Gde E-250 Quality-A) complete all as specified.
M&L for preparation of new or previously untreated wooden surface of any description two coats of synthetic enamel paint over a coat of pink primer including prepration to new wooden surfaces exc.10cm in width or girth complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new or previously untreated steel surface of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Taking down eaves gutters and rain water pipes CI/PVC ,110 mm/75mm including all fittings and size and pattern complete all as specified & directed by Engineer-in- charge.
Supply & fixing 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvent fixed to walls complete all as specified & directed by Engineer-in- charge.
Supply & fixing 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvent laid in trenches complete all as specified & directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bend 110mm bore of any radius complete all as specified & directed by Engineer-in- charge.
Supply & fixing 75mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvent fixed to walls complete all as specified & directed by Engineer-in- charge.
Supply & fixing 75mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvent laid to trenches complete all as specified & directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bend 75mm bore of any redius complete all as specified & directed by Engineer-in- charge.
S&F for PVC (SWR) floor trap, plain with grating 75mm diameter of outlet, setting and jointing with solvent cement complete all as specified and directed by Engr-in-Charge.
S&F for 110 mm PVC (SWR)" P" Trap complete all as specified
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal provided with access door complete all as specified and directed by engr-in-charge.
S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal provided with access door complete all as specified and directed by engr-in-charge.
S&F 75mm bore PVC (SWR) branch piece double (double Y) equal or unequal provided with access door complete all as specified and directed by engr-in-charge.
S&F 75 mm PVC SWR vent cowl complete all as specified
S&F 110 mm PVC SWR vent cowl complete all as specified
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified & directed by Engineer-in-charge.
M&L rendering 12mm thick on brick work or concrete surface in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L rendering 15mm thick on brick work or concrete surface in cement mortar (1:4) and finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge
M&L rendering 5mm thick in cement mortar (1:3) on ceiling/ soffit of slabs finished even and smooth without using extra cement complete all as specified & directed by Engineer-in- charge.
M&L preparing newly plastered or pointed surface of ceiling and applying two coats of white wash complete all as specified & directed by Engineer-in-charge.
M&L on newly plastered surface of walls preparatory to distempering and applying two coats of oil bound distemper of any colour over chalk whitening including preparation complete all as specified and directed by Engineer in charge
M&L prepration of newly plastered or pointed surface of walls and applying two coat of cement base paint complete all as specified & directed by Engineer-in- charge.
Preparation of old decorated plastered or un-plastered surfaces of ceiling of any height including cornices, pilasters by brooming down with steel wire brushes scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc and applying one coat of white wash on ceiling all as specified and directed.
M&L for complete removal of existing treatment of old decorated plastered or un-plastered surfaces of walls of any height including cornices, pilasters by brooming down with steel wire brushes scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc and applying two coats of cement base paint including preparation on walls all as specified and directed.
M&L for Preparation of old decorated plastered or un-plastered surfaces of walls of any height including cornices, pilasters by brooming down with steel wire brushes scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc making good holes cracks with wall putty , rubbing down with sand paper to make the surfaces even and smooth and applying one coat of distemper oil emulsion white or tinted, all as specified and as directed.
Cutting chases, pinning in, making good to facing where reqd and pointing in CM 1:3 to ends of edges of landing etc and cutting chases for concealed water tubing and making good cutting exc 10 cm but n.exc 20 cm girth complete all as specified and directed by Engr-in-charge.
Taking up or down steel tubing 15mm bore and connections, including cleaning for refixing or removal to store.' complete all as specified and directed by Engr-in-Charge.
All as per item No 75 but 20mm bore complete all as specified and as directed by Engr-in-charge.
S&F 15mm bore GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr-in-Charge.
All as per item No 77 but 20mm bore complete all as specified and as directed by Engr-in-charge.
Refixing old steel tubing and connections in new or old postion (wall, ceiling , floors ,etc) 15mm bore. complete all as specified and as directed by Engr-in-charge.
All as per item No 79 above item but 20mm bore complete all as specified and as directed by Engr-in-charge.
S&F in repairs vitreous china wash down water closet pedestal pattern pan white with trap including connection to existing out joint pipe, flushing pipe or Cistern, antisyphonage pipe, including making, etc complete including making good to floor etc complete all as specified and as directed.
S&F in repair plastic water closet seat cover of White colour closed pattern with flat bottom and cover with mild steel chromium plated hinging device etc complete as specified and directed.
S&F in repair stainless steel sinks 1mm thick sheet with over all size 495mm x 420mm and bowl size 410mmx330x160mm for kitchen or laboratory with pluge washers and waste, including bedding in cement mortar on to dwarf walls or including fixing centilever bracket and connecting uinon to waste pipe including chromium plated waste coupling and waste pipe complete all as specified and directed by Engr-in-Charge.
S&F in repairs plate rack made of stainless steel 1.00 mm thick of size 600x900mm fixed to wall with and including nuts & bolts of suitable size for fixing in wall complete all as specified and directed.
S&F in repair PVC low level flushing cistern syphonic action type white with inlet ball valve, handle including brackets 10 ltrs capacity etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china wash hand basin white flat, back of size 580mm x 450mm including 32mm waste coupling and PVC waste down pipe complete all as specified and directed by Engr-in-Charge.
S & F in repairs PVC connections 15mm size with PTMT nuts and bolts of length 450mm etc complete all as specified and directed
S&F in repair pillar tap, cast copper alloy fency type chromium plated screwed down high, pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed to 15mm bore of pipe etc all as specified and directed by Engineer-in- charge.
S&F in repairs bib taps, cast copper alloy with crutch or butterfly handle fency type, screwed down , screwed for iron pipe or for brass ferrule and fixed in iron pipe of 15 mm complete all as specified and directed.
S&F in repairs brass cromium plated jet for pedestal water closet including PVC flexible pipe alongwith complete necessary fitting all as specified & directed by Engineer-in- charge.
S&F in repair stop valves/angle valve 15mm bore , cast copper alloy fency type, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed etc complete all as specified and directed.
Dismantling water tanks exc 250 & nexc 500 ltr complete all as specified and directed
S & F in repairs brass ball valves high pressure with polythylene float and fly nut complete screwed for iron pipe dixed 20mm dia etc complete all as specified and directed by Engr-in-Charge.
S & F rotational moulded polyethylene water storage tanks triple layered of capacity 500 ltr (cylindrical vertical with closed top) hoisted and fixed in position including nipple suitable for water tank complete all as specified and directed by Enigneer-in-charge.
S&F in repairs harrision rails, mild steel , chromium plated with fixing bracket, stops, rollers etc complete all as specified and directed.
M/L 75 mm thick PCC 1:3:6 mix type C2 (40mm graded crushed stone aggregate) as in plinth protection and paving finishing surface even and smooth without using extra cement laid in alternate bay complete all as specified and directed.
Taking down shutters of any desciption area exc 1.0 Sqm but n.exc 2.0 Sqm each and removal to store complete all as specified and directed.
S&F in repair Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old or previously untreated wooden surface of any description and applying one coat of synthetic enamel paint exc.10cm in width or girth complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old or previously untreated steel surface of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F in repair stop valves/angle valve 15mm bore (concealed type) , cast copper alloy fency type, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed etc complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves of bore dia 15 mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves of bore 20 mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
Disconnecting existing tank, setting aside for repair, cleaning etc and hoisting if reqd reconnecting and refixing in position exc 250 & nexc 500 ltr complete all as specified and directed.
S&F in repair brass chromium plated tubular towel rail 20mm dia (D) type 60cm long between flanges complete all as specified and directed by Engr-in-Charge.
S&F in repairs brass chromium plated shower roses with or without swivel joint 75mm size incl fixing to steel pipe complete all as specified and directed.
M&L for cement concrete type E - 2, 1:5:10 (using 40 mm graded brick aggregate) as in sunken flooring complete all as specified and directed by Engineer-in-Charge.
S&F 32 mm dia PVC pipe 450mm long beveled cut at both ends by making hole in walls sunken portion approx above the R C C slab and ceiling finished the hole with cement plaster 1:2 to match with existing surfaces complete.
M&L 25mm thick Cement concrete 1:2:4 type B-0 using 20 mm graded crushed stone aggregate as in sub flooring rough finished surface complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge.
M&L complete removal of existing treatment and applying three coats of white wash on wall surfaces including prepration of Old plastered surfaces complete all as specified and as directed by Engr-in-charge.
M&L two coats of white wash on wall surfaces including prepration of newly plastered surfaces complete all as specified and as directed by Engr-in-charge.
Taking down carefully the point wiring (light, Fan, socket or power) complete, (incl fittings such as switches, sockets any type, ceiling roses, pandents, light fittings, etc and making good disturbed surface of walls floors etc. all as specified & directed by Engineer-in-charge.
M &L Point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through and including 20mm dia PVC rigid non metallic conduit with all accessories such as internal bend end caps etc complete concealed in walls/ceiling/roof/etc including provision of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor, all as specified and as directed for the following :-
One ligth point controlled by one switch with cables 1.5 sqmm size
One celing/Exhaust fan point controlled by one switch with cables 1.5 sqmm size
One 3 pin socket outlet,5 amps,independent,with cables 1.5 sqmm size
One 3 pin socket outlet 5 amps on same board with other switches,with cables 1.5 sqmm size
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm size.
One light point controlled by 2 way switches,with cables 1.5 sqmm size.
All as per item No. 115 here in before but 2.50 Sqmm copper conductor wiring with 1.50 Sqmm copper conductor as earth continuity for 15/16 Amps socket outlet on independent board all as specified & directed by Engineer-in-charge.
Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals complete all as specified and as directed by Engineer-in-charge
Supply and Fix Switch Piano,Flush type single pole , one way 5 Amp complete all as specified and as directed by Engineer-in-charge.
Supply and Fix Socket outlet 3 pin, 5 A flush Piano,Flush type complete all as specified and as directed by Engineer-in-charge.
M&L Socket outlet multi purpose 3 in 1, 6 pin, 5 & 15 Amps, flush type complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F in replacement bell push, AC, 230 volts, single pole all as specified and directed by Engineer-in-charge.
S&F in replacement bell Ding Dong, AC, 230 volts, single pole controlled by one bell push all as specified and directed by Engineer-in-charge.
Supply and fix LED tube light fittings 1200 mm, 20W, 240V, 50Hz,rated input current- 0.070-0.110, rated input watt 20, oprating voltage range- 140-270, P.F- not less then 0.95, surge protection upto- 4Kv, IP20, THD shell be less then 10%, CCT- (k0)- 6500ANSI, higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviromental friendly, energy efficient complete all as specified and directed by Engineer-in-charge..
S & F in replacment of existing light fitting with LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer - in - Charge.
S & F in replacment of existing light fitting with Water tight bulk head LED 10 Watt light fitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed by Engineer - in - Charge.
Taking down Ceiling fan, sealing cable end, dismantling blades from fan and keeping in safe custody for reuse at site and making good disturbed surfaces complete all as specified and as directed by Engineer-in-charge.
Refixing only ceiling fan and connecting up including provision sutiable of new down rod for ceiling fans,of cable from celling rose/ connector to fan all as specified and as directed by Engineer-in-charge.
S&F fan regulator , flush stapped type ,electronic , single phase 230 volt complete all as specified and directed by Engineer-in-charge.
Taking down of any size of building security light fittings complete all as specified and directed by Engineer-in-charge.
Supply and fixing bldg security light fitting LED 30/35 W LED made up of pressure die cast aluminium housing with potted isolated driver and high power LED and indl lenses, operating range- 90V to 340V AC. , IP66 with high power LED lamp compete all as specified and directed by Engineer-in-charge.
M & L Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc all as specified and as directed by Engineer-in-charge.
Supply and fixing factory made sheet metal enclosures SPN 8 way double door 240 v for DB,s suitable for having MCB flush with wall complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB SPN 40 Amps 240 V, C- curve, 50 Hz, breking capacity-10 kA. complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB SP 6-32 Amps240 V, C- curve, 50 Hz, breking capacity-10 kA . complete all as specified and directed by Engineer-in-charge.
M &L Earthing including earth work complete with galvanised steel earth plate electrode 60cm X 60 cm X 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level with the top edge of electrode not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia means of bolts, nuts,check nuts and washers of galvanised iron and GI lead protected with protection pipe of GI light grade 15mm dia upto 3mtr above ground level along poles fixed with two clamps of 25mm 3mm flat iron and connected to running earth wire at top of poles and watering pipe 20mm bore of GI medium grade all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point all as specified and direct and testing on completion including PCC 1:3:6 ) C-I cover and frame excavation and earth work etc complete all as specified in elect plate No 3 of SSR Part -I 2009 Note :- PCC Chamber shall be constructed at least 1.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in soft and loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed.
M&L cement concrete 1:2:4 type B2 (using 40 mm graded crushed stone aggregate) as in foundation filling of fencing posts & struts including form work complete all as specifed and directed by Engineer-in-Charge
S&F mild steel angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings c/c and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
M&L for TMT mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with dia of neck between 11mm to 15mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
Supply only Chain link MS galvnised fencing ,3 mm dia, 50mmx50mm mesh , complete all as specified and directed by Engineer-in-charge.
Labour only fixing chain link fencing including line wires, any mesh, size and type to any type of standards rails, straining bolts, etc. including provision of binding wire,complete all as specified and directed by Engineer-in-charge.
M&L two coat of synthetic enamelled paint on new steel surface of any description over 10 cm in width or girth over one coat of red oxide primer incl preparation of new surfaces etc complete all as specified.
Fixing only Commissioning and testing of Air conditioner (twin cool) 2 Ton capacity split type , 5 star with dual smart inverter technology in copper built with in built air ioniser & Plasma filter for better indoor air quality with cordless remote control unit covering EER 3.2 with stablizer of suitable size all as specified and directed by engr-in-charge. Note :- (i) Unit rates quoted by contractor shall be deemed to included for cutting holes in walls/floor and making good as per existing using plaster (1: 3) and puttey and match with finished surface. (ii) Necessary stand for outer unit shall be deemed to be included in quoted rates. Note : AC and voltage stablizer shall be issued under Schedule 'B' free for fixing only
M& L for sub main Wiring for circuit/submain wiring in PVC Conduit along with earth wire with 2x4Sqmm+1x4.0Sqmm as earth wire of FRLS PVC insulated copper conductor multistranded (ISI marked), complete all as specified and directed.
JAY ANN CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .