Executive Engineer Electric Division Sumbal,
Executive Engineer Electric Division Sumbal,
Rate contract for Improvement,Errection of HT,LT network creation,augmentations of various works under CDF,DC work T,D MPLADS ,snow damage ,B2V and other time bound works in respect of Electric Division Sumbal Sonawari
2020_PDD_105249_1
EDS-4 OF 2020-21
Open Tender
Electrical Works
Item Rate
15 days
Sumbal
As per SBD
8 documents required · 8 mandatory
₹1,000
Executive Engineer Electric Division Sumbal
₹35,000
2 Nov 2020
26 Sept 2020
9 Oct 2020
26 Sept 2020
8 Oct 2020
28 Sept 2020
26 Sept 2020 - 28 Sept 2020
180 days
Amount
Providing, Errection,testing & commissioning of 11 Mtr long ST Poles SP-56 including manual, mechanical carriage, excavation of pole pits
Providing, Errection,testing & commissioning of 9 Mtr long ST Poles SP-33 including manual, mechanical carriage, excavation of pole pits
Providing,Errection,testing & commissioning of 8 Mtr long ST Poles SP-15 including manual, mechanical carriage, excavation of pole pits
loading,unloading,Transportation,Installation, testing and commissioning of 63 /100/250Kva, 11/0.440 KV distribution transformer .(Transformer shall be provided by the Deptt.)
Loading,Transportation,insurance,unloading,carriage ,delivery at site and errection of ST Poles 11 m long (410 SP-56) completely errected in the pit of 1/6th of the pole length including excavation and back filling of the pole pit and also incription of permenant marking on each pole (Name of Scheme 2019-20,xx,xx means pole Number).(Poles shall be supplied by the department).
Loading,Transportation,insurance,unloading,carriage ,delivery at site and errection of ST Poles 9 m long (410 SP-33) completely errected in the pit of 1/6th of the pole length including excavation and back filling of the pole pit and also incription of permenant marking on each pole (Name of Scheme 2019-20,xx,xx means pole Number).(Poles shall be supplied by the department).
Loading,Transportation,insurance,unloading,carriage ,delivery at site and errection of ST Poles 8 m long (410 SP-15) completely errected in the pit of 1/6th of the pole length including excavation and back filling of the pole pit and also incription of permenant marking on each pole (Name of Scheme 2019-20,xx,xx means pole Number).(Poles shall be supplied by the department).
Loading,Transportation,insurance,unloading,measuring binding of conductor ACSR 0.1 (Dog) including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices(conductor to be supplied by the department)
Loading,Transportation,insurance,unloading,measuring, ,laying, and stringing of overhead 0.05 (Rabbit) ACSR conductor on cross arms through insulators including joints by PG Clamps where ever required complete in all respects as per REC standard. (conductor to be supplied by the department)
Loading,Transportation,insurance,unloading,measuring, ,laying, and stringing of overhead 0.03 (weasel) ACSR conductor on cross arms through insulators including joints by PG Clamps where ever required complete in all respects as per REC standard. (conductor to be supplied by the department).
Supplying and fixing of pole Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection
Supplying and fixing of pole Earthing Complete by GI Spiral Earthing, 8 SWG 115 turn coil earthing as per REC J-1 drawing
Painting of ST poles with Zinc rich red colour paint upto bottom section & silver colour for rest of of the pole, inscribed with permenent marking on each pole "Name of scheme-2016-17/xx" (xx mean pole numbers say 01,02...) in white paint in backgound of green paint at conspicious place. The paint shall have to be sprayed not brushed. The rate offered shall include cost of paint etc
Supply and fixing of clamps for LT Shackle insulators (Including Shackle 45 kN insulators) with GI back clamps to be fixed without drilling/punching of poles on ST poles.
Supply and fixing of clamps for LT Shackle insulators (Including Shackle 45 kN insulators) with MS back clamps to be fixed without drilling/punching of poles on ST poles.
Supplying and fixing of Galvanized Nuts and Bolts of sizes.
Supplying and fixing of MS Nuts and Bolts of sizes.
Supplying and erection of GI Channel “V’ cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure. NOTE: Please refer Pole drawings for details
Supplying and erection of MS Channel “V’ cross-arm (75 x 40x6mm) with MS Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure. NOTE: Please refer Pole drawings for details
Supplying and erection of GI channel/angle cross arms including fixing GI channels ( 100x50x6mm)8ft / (75x40x6 mm)8ft / angles(50x50x6 mm)4/5ft with 50X8 mm back clamps without drilling/punching holes in the poles.
Supply and installation of 11KV pin insulators(polymer)5KN with GI pins dia of 25mm as per ISI specification as per REC standard.
Providing & fixing of 11KV G.O Switches of capacity 200 A (09 insulator post type) with arragement for pad locks & operating rod . The operating rod should be G.I Pipe (B-class) of 25 mm dia of requisite length.
Providing & fixing of 11KV Drop out fuse set
Providing & fixing of Lightning Arrestor (station type)
Providing & fixing of Lightning Arrestor (line type)
Providing & fixing of LT Fuse set
Providing & fixing of Disc insulator (45 KN B&S) with GI fitting compitable with ACSR 0.03/0.05/0.1 conductor
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 400 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 300 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 185 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 120 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 95 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 16 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing, laying, testing & commissioning of 3x35mm sq +1x105mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03(three) power cores stranded, compacted circular Aluminium conductor screened with Black extruded semi conducting compound, natural coloured XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires.
Providing, fixing , testing & commissioning of cable kits ( heat shrinkable)
Providing, fixing , testing & commissioning of cable kits ( push on type)
Providing & fixing of Eye hook & suspension clamp assembly
Providing and fixing of Anticlimbing devices on poles made out of fabricated Iron without use of barbed wire type devices).
Providing and fixing of Danger Plates on poles
Providing & fixing of Guy assembly comprising of Guy Wire, Guy insulator, Guy rod and turn buckle complete etc
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole including muffing 20 cm above ground level plaster and curing of concrete in size of 600x600x1700mm for 9 and 8 mtr long ST poles (540, SP-33 and 15) (the leftover pit after concreting to be filled with soil and boulders) NOTE: Please refer Pole drawings for details 11 KV LINE and LT cable
Providing & fixing of bi-metallic clamps for fixing of LT cable with distribution transformers having capacity upto 100 kVA
Providing & fixing of bi-metallic clamps for fixing of LT cable with distribution transformers having capacity of 200 kVA & above
Providing & fixing of 300 mm sq Aluminum Thimbles for cable terminations
Providing & fixing of 185 mm sq Aluminum Thimbles for cable terminations
Providing & fixing of 120 mm sq Aluminum Thimbles for cable terminations
Providing & fixing of 95 mm sq Aluminum Thimbles for cable terminations
Providing and fixing of three point Sub Station earthing as per REC approved construction standards with F5, F10 & J2 drawings issued by REC as reference. Each electrode to be connected through double GI strips to be fixed on baby insulators. The termination should be bolted and not welded.
Providing Errection, Testing & commissioning of 160 A-200 A with breaking capacity of 36 kA MCCB TPN (L&T, Hager, Legrand/standard make) . The MCCB should be housed in enclosure fabricated out of MS sheet of 18 SWG duly powder coat painted.
Providing Errection, Testing & commissioning of 315 A-400 Awith breaking capacity of 50 kA MCCB TPN (L&T, Hager, Legrand /Standard make) . The MCCB should be housed in enclosure fabricated out of MS sheet of thickness not less than 2 mm duly powder coat painted.
Providing & fixing of spreader terminal- 4 pole 250A
Providing & fixing of spreader terminal- 4 pole 400A
Providing and fixing of shackle insulators
Providing, Laying, stringing, tensioning and binding of conductor ACSR 0.1 (Dog) including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices
Providing, Laying, stringing, tensioning and binding of conductor ACSR 0.05 (Rabbit) including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices
Providing, Laying, stringing, tensioning and binding of conductor ACSR 0.03 (Weasel) including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices
Supply,transportation & commisioning of 100 KVA Step-down transformer 11/0.440KV(energy efficient) fitted with Silaca Gel Breather,oil filled and tested,complete in all respects including earthing of sub-station as per latest specifications and drawing adopted/approved by the department
Supply inastallation, & commisioning of 200 KVA Step-down transformer 11/0.440KV (Energy efficient) fitted with Silaca Gel Breather,oil filled and tested,complete in all respects including earthing of sub-station as per latest specifications and drawing adopted/approved by the department
Providing, installation, testing and commissioning of 250 KVA 11/0.433 KV tansformer including sub-station earthing by providing of M.S. rod 16 mm dia (3 No's) as per REC J-I specification, galvanized 25x3 mm flat iron for transformer nuetral and body LA earthing, salt charcol etc complete job
Supply inastallation, & commisioning of 63 KVA Step-down transformer 11/0.440KV aluminium wound fitted with Silaca Gel Breather,oil filled and tested,complete in all respects including earthing of sub-station as per latest specifications and drawing adopted/approved by the department
Supply,transportation & fixing of MS Channel,iron cross arms 100X50X50X6mm,9 ft long duly fabricated,red oxide & aluminium paint coated including all necessary nuts and bolts & washers (as per the latest specification and drawing approved by the department).
Supply,transportation & fixing of MS Channel,iron cross arms 75X50X50X6mm,9ft long duly fabricated,red oxide & aluminium paint coated including all necessary nuts and bolts & washers (as per the latest specification and drawing approved by the department).
Supply,transportation & fixing of MS Channel,iron cross arms 75X40X40X6mm,5 ft long duly fabricated,red oxide & aluminium paint coated including all necessary nuts and bolts & washers (as per the latest specification and drawing approved by the department).
Supply,transportation & fixing of Al.Braces 50X50X6mm (3/4ft)duly fabricated,red oxide & aluminium paint coated including all necessary nuts and bolts & washers (as per the latest specification and drawing approved by the department).
Supply,Installation and fixing of Galvanised Guy Wire No. 7/14 and 8 SWG
Supply, Instalaltion and laying of 16 mm sq 2 core cable (havels/Polycab make)
Supply,Installation and fixing of 11 KV link set as per REC standard
Installation of single phase and three phase digital/prodigy meter with seal and thimbles.
Supply,Installation & fixing of 1-ф prodigy Energy meter 5-30/10-60 Amp DLMS complaint of Accurancy clause including Providing of thimbles for energy meter connection with seal.
Supply,Installation & fixing of 3-ф prodigy Energy meter 5-30/10-60 Amp DLMS complaint of Accurancy clause including Providing of thimbles for energy meter connection with seal.
supply ,installation, testing and commissioning of kiosk type outdoor HT meter Units at 11 KV level employing CT/PT combo unit with 3 phase 4 wire CT/PT operated fully static, AMR compatible, DLMS complaint Tri-Vector energy meter, with RS-232 communication port and GPRS modem with 35 mm2 3 core 11 KV cable of length 11 mtr and 9 mtr with cable kits fixied on each end of cable. with earthing strip and rods complete.
laying and fixing of 16 mm² 2 core almunium cable (Service line)(Rate to be quoted per meter) complete job with relevant ISI standard.
Providing and fixing of PG Clamps 16mm/10mm Termination lugs with relevant ISI standard.
Providing and fixing of Rawal Plug with screws relevant ISI standard.
Dismentling of 11 Mtr long ST Poles including carriage to divisional stores,
Dismentling of of 9 Mtr long ST Poles including carriage to divisional stores,
Dismentling of of 8 Mtr long ST Poles including carriage to divisional stores,
Dismentling of of PCC Poles including carriage to divisional stores without damaging / breaking the pole. If the pole gets damaged no payment will be made.
Dismentling of of wooden Poles including carriage to divisional stores,
Repositioning of 9 mt ST tilted poles
Repositioning of 8 mt ST tilted poles
Repositioning of PCC tilted poles
Repositioning of tilted wooden poles
Dismantling of conductor ACSR 0.1 including hardware fittings and returning the dismantled material to stores.
Dismantling of conductor ACSR 0.05 including hardware fittings and returning the dismantled material to stores.
Dismantling of conductor ACSR 0.03 including hardware fittings and returning the dismantled material to stores.
Re-stringing, tensioning and binding of conductor ACSR 0.1 including fixing of hardware fittings and jointing as per standard practices
Re-stringing, tensioning and binding of conductor ACSR 0.05 including fixing of hardware fittings and jointing as per standard practices
Re-stringing, tensioning and binding of conductor ACSR 0.03 including fixing of hardware fittings and jointing as per standard practices
Branch cutting
M/S BABA ELECTRICALS
Rather Engineering Works
SHAH ELECTRICALS
SS ENTERPRISES
M/s Bilal Electricals
haris enterprise
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .