Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹19.4 L+₹35,945.50 (1.89%)Rejected-Finance 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹19.9 L+₹88,027.50 (4.62%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹21.2 L+₹2.2 L (11.3%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹28.8 L+₹9.7 L (51.1%)Rejected-Finance 179 THE MALL AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹43,100
Closing Date
23 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-46/2020-21 PROVISION OF STANDBY LT CHANGEOVER PANEL IN POWER HOUSE AND CERTAIN B/R AND E/M MINOR WORKS AT AF STATION AMBALA UNDER GE AF AMBALA
2020_MES_391420_3
GE AF/AMB-46/2020-21
Open Tender
Civil Works
Item Rate
120 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE AF AMBALA
₹43,100
Yes
24 Mar 2021
1 Feb 2021
25 Feb 2021
1 Feb 2021
23 Feb 2021
10 Feb 2021
60 days
Amount
Surface excavation not exceeding 30cm deep and averaging 15cm deep in soft / loose soil and getting out including taking out roots, shrubs etc, complete all as specified and as directed
Excavating in post holes (or similar holes) each not exceeding 0.5cum, returning, filling in, getting out in soft / loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50m complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc.not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, using broken stone or boulders complete all as specified and as directed
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed
Demolition of concrete of any description and in any position not otherwise specifically provided for and removal of debris complete all as specified and as directed
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, chajjas, etc. also splays between floors and beams, etc. in flat surfaces for rough finish complete all as specified and as directed
M&L for plain cement concrete in 1:3:6 (type C-2) using 40mm graded stone aggregates as in foundation, filling, mass concrete, etc. complete all as specified and as directed
M&L for 40mm thick plain cement concrete type B-1,1:2:4 (using 20mm graded stone aggregates) as in floors, sub-bases, etc. finished to receive floor finishes, etc. complete all as specified and as directed
M&L for 25mm thick plain cement concrete type B-1,1:2:4 (using 20mm graded stone aggregates) as in floors, sub-bases, etc. finished to receive floor finishes, etc. complete all as specified and as directed
M&L for reinforced cement concrete type B-1,1:2:4 (using 20mm graded stone aggregates nominal mix) as in chajjas, parapets, louvers, fascia, railings (exceeding 600mm in height) and similar works complete all as specified and as directed Note: Reinforcement will be measured and paid separately under respective item herein
M&L for plain cement concrete 1:2:4 (type B-1) using 20mm graded stone aggregates as in coping, padding, kerbs, bed blocks, locking of interlocking tiles, etc. complete all as specified and as directed
M&L for plain cement concrete 1:2:4 (type B-2) using 40mm graded stone aggregates as in foundation filling, mass concrete, complete all as specified and as directed
M&L for 50mm thick plain cement concrete type B-1,1:2:4 (using 20mm graded stone aggregates) as in path, hardstanding, floors, sub-bases, etc. finished to receive floor finishes, etc. complete all as specified and as directed
M&L for 150mm thick plain cement concrete type B-2,1:2:4 (using 40mm graded stone aggregates) as in floor, pavings, etc. complete all as specified and as directed
M&L for 100mm thick plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in sub-bases, etc. complete all as specified and as directed
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in foundations filling, mass concrete, etc. complete all as specified and as directed
Supply and lay glass dividing strips, 3mm thick inserted in position, conforming to design approved complete all as specified and as directed
M&L for mild steel TMT bars grade Fe-500D, 10mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410W (grade-E 250) quality-A complete all as specified and as directed
S&F steel work in tubular trusses including special shaped washers, etc. using ERW or induction butt welded tubes conforming to IS-1161-1979 structural grade 240 complete all as specified and as directed
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed at both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm in length, dia of neck & shank 10mm complete all as specified and as directed
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 410-W (grade E-250) quality-B complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:4) complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan as in half brick thick walls built in CM (1:4) complete all as specified and as directed
M&L rendering 15mm thick in cement mortar (1:4) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, etc. finished even and smooth without using extra cement complete all as specified and as directed
M&L rendering 15mm thick in cement mortar (1:6) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, inner sides of drains, etc. finished even and smooth without using extra cement complete all as specified and as directed
M&L rendering 15mm thick in cement mortar (1:4) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, inner sides of drains, roof, etc. finished even and smooth without using extra cement complete all as specified and as directed
M&L rendering 10mm thick in cement mortar (1:6) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, inner sides of drains, roof, etc. finished even and smooth without using extra cement complete all as specified and as directed
M&L for rendering 5mm thick plaster, in cement mortar (1:3) on fair faces of concrete surfaces of soffits of slabs, ceilings, etc. finished even and smooth without using extra cement complete all as specified and as directed
M&L for rough cast plaster including 15mm thick rendering in CM 1:3 on brickwall or concrete surfaces, all as specified in SSR Part-I clause 14.22 complete all as specified and as directed Note: Rough cast finish shall be made as under: (i) After applying the under coat of cement mortar 1:3 and while it is still in plasic state the rough cast mixture consisting of crushed stone or fine gravel / aggegates (of size between 6 to 12mm depending on the texture required) mixed with course sand and cement in the ratio of 1:1:1 shall be applied and finished even (ii) The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered
M&L for preparing of new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) complete all as specified and as directed
M&L for preparing of new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
M&L for preparing of new wood / wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, tint as approved complete all as specified and as directed
M&L preparation of new plastered / unplastered masonry / concrete wall surfaces, roof coverings, etc. and applying two coats of exterior acrylic anti-fungal paint in camouflage pattern (as approved by the GE) as per manufacturer's instructions complete all as specified and as directed
M&L for preparing of new plastered or unplastered surfaces and applying two coats of cement based paint (of approved tint) over a coat of chalk whitening on walls complete all as specified and as directed
M&L preparation of old plastered / unplastered, treated / untreated surfaces and applying two coats of white wash on walls, etc. complete all as specified and as directed
M&L preparation of new plastered / unplastered and applying three coats of white wash on walls, etc. complete all as specified and as directed
M&L for preparation of old/new masonry / concrete wall surfaces and applying two coats of oil emulsion distemper over a coat of wall primer including a coat of wall care putty 1mm thick including all necessary staging, scaffolding, safety precautions, etc. as required to work at heights, etc. complete all as specified and as directed
M&L for non-skid ceramic tiles, coloured, 7 to 8mm thick, joint free, edge cut, exceeding 0.06sqm and not exceeding 0.11sqm in size, of superior quality on floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles complete all as specified and as directed
M&L for non-skid ceramic tiles, coloured, 7 to 8mm thick, joint free, edge cut, exceeding 0.11sqm and not exceeding 0.18sqm in size, of superior quality on floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles complete all as specified and as directed
M&L for glazed ceramic tiles, coloured of size 450x300x7 to 8mm thick, of superior quality on vertical faces, dados, skirting, risers, etc. laid over and including 10mm thick backing coat in CM 1:4 roughened to receive tiles, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles with complete all as specified and as directed
M&L for vitrified coloured tiles 10mm thick, of size not exceeding 0.36sqm each, of superior quality, in floors, etc. laid over 15mm thick screed bed in CM (1:6) (rate shall be included) set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed
S&F steel window (box type) factory made double shutter (glazed and wire gauzed) with side hung shutters including pintle type hinges, steel handles fabricated type for each leaf duly welded, mild steel barrel tower bolts 150mm size (02Nos for each leaf) duly welded, with and includingglazing bars dovetailed or welded including MS fillets, including provision and welding of guard bars including one shop coat of red oxide primer over window, frame & guard bars complete all as specified and as directed Notes: (i) Windows shall be fabricated as per HQ CE Chandigarh Zone drawing No. TD-219 Sh 1/3 to 3/3 dated 02 Jan 2007 amended dated 22 Jun 07 in Sh 1/3 and dt 15 Jun 07 in sh 2/3 & 3/3 & TD-220 sheet 1/3 to 3/3 These drawings shall be referred from the office of GE (AF) Ambala/HQ CWE AF AMBALA (ii) Glazing and wire gauge shall be measured and paid separately (iii) Double shutter area of opening shall be measured for payment purposes
M&L 35mm thick factory made plain framed paneled door shutter (two panels) 2nd class HW rail and style with lock rail and panels of 12mm thick ISI marked veeneered particle board with commercial veeneering on both faces, with size of rail and style shall be as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and as directed
S&F butt hinges, 125mm size, heavy weight, cold rolled mild steel complete all as specified and as directed
S&F 200mm long mild steel barrel tower bolts stove enameled black with bright bolts complete all as specified and as directed
S&F mild steel sliding door bolts, 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed
S&F 3mm thick sheet glass, ordinary quality, area not exceeding 0.5sqm in each pane, cut to required size and shape to existing wooden shutters / MS windows / shutters, etc. with glazing clips, glass oil putty, etc. complete all as specified and as directed
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
S&F structural steel, rolled section such as joist, beam, channel, angle, tee, in available lengths as in door frames including welding of 10mm dia tie bar complete all as specified and as directed
M&L for mild steel 25x5mm flat iron as in doors etc. complete all as specified and as directed
S&F cast iron Nahani trap, with grating including jointing to waste pipe (dia of outlet 75mm) fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed
Taking up or down 15mm bore steel water tubing and connections including disposing off, etc. complete all as specified and as directed
Taking up or down 20mm bore steel water tubing and connections including disposing off, etc. complete all as specified and as directed
Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame) and disposing off complete all as specified and as directed
Dismantling and breaking up drain pipes, etc. 75mm bore CI pipes jointed in cement mortar and disposing off complete all as specified and as directed
S&F steel water tubing, 15mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS: 1239 fixed to walls / ceilings or laid in floor / trenches complete all as specified and as directed
S&F steel water tubing, 20mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS: 1239 fixed to walls / ceilings or laid in floor / trenches complete all as specified and as directed
Fixing only steel water tubing, 15mm bore, medium grade, galvanised with screwed and socketed joints, including supply and fixing all fittings, and fixed to walls or laid in floors / trenches complete all as specified and as directed for the following bores: Note: Serviceable tubings obtained from dismantling herein before will be reused under this item
Fixing only steel water tubing, 20mm bore, medium grade, galvanised with screwed and socketed joints, including supply and fixing all fittings, and fixed to walls or laid in floors / trenches complete all as specified and as directed for the following bores: Note: Serviceable tubings obtained from dismantling herein before will be reused under this item
S&F 75mm bore cast iron soil, waste and vent pipes, spun pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and as directed
S&F 75mm bore bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and as directed
S&F solid PVC door frame of size 50x47mm made out of 5mm thick plain / printed coloured PVC sheet (as approved) reinforced with MS square tube all as per specifications and drawing given in SSR Part-I 2009 all as per manufacturer's instructions and making good the disturbed surfaces complete all as specified and as directed
S&F factory made solid panel PVC door shutter, 30mm thick, consisiting of MS frame made out of MS tubes for top and bottom rails, MS frame shall be moulded with plain coloured PVC 'C' channel and having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain coloured PVC sheet top rail, lock rail and bottom rails, paneling of plain coloured PVC sheet to be fitted in MS frame welded / sealed to stiles and rails with suitable PVC sheet beading and jointed together using solvent and fixed in position in frame as per site requirement and specified in MES Schedule 2010 complete all as specified and as directed Door Width Size of style Size of rails exceeding 1.5' but not exceeding 2' 50mm 50mm exceeding 2' but not exceeding 2.5' 50mm 75mm exceeding 2.5' but not exceeding 3' 75mm 100mm exceeding 3' 100mm 125mm
S&F steel ventilators with top hung shutter including hinges, peg stay to receive glass or gauze with and including fixing with 25x5mm MS flat and one shop coat of primer complete all as specified and as directed
S&F 100mm long mild steel medium weight cold rolled butt hinges fixed with screws / welded to frames complete all as specified and as directed
S&F 125mm long extruded aluminim handles, fabricated type, anodised complete all as specified and as directed
S&F 250mm aluminium anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed
S&F 3mm thick figured / pin head glass, ordinary quality, cut to required size and shape for windows, etc. in glazing not exceeding 0.5sqm in area with oil putty including hacking off old glass and putty fillings, etc. complete all as specified and as directed
S&F in repairs 15mm dia bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S&F in repairs 15mm dia stop cocks, concealed type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed
S&F 15mm dia pillar taps, fancy type, cast copper alloy, with capstain heads, chromium plated, screwed down, high pressure, with or without lettered 'HOT'/'COLD', with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed
S&F in repairs wash hand basin, vitreous China, coloured, flat back type, of size 640x450mm, including CI brackets, cutting for and pinning in ends of brackets with coupling and including PVC connection 60cm key with brass union complete all as specified and as directed
S&F waste coupling, 32mm, brass, half / full threaded, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed
M&L for 20mm thick granite stone slab, of any type, table rubbed and polished, in steps, jambs, pillars, window cills, cooking platforms and the like in laid over and including 20mm thick screed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of slab complete all as specified and as directed
M&L for machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complet complete all as specified and as directed
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed
S&F in repairs vitreous China wash down water closet pan (Pedestal pattern), coloured (as approved), with 'P' or 'S' trap, including flush pipe, trap, connection to drain or outgoing pipe, anti-syphonic pipe, seat cover to match with colour of WC, closed pattern with flat bottom & cover and chromium plated mild steel or aluminum anodized hinge device and jointing and connecting up complete all as specified and as directed
S&F 10litres capacity PVC flushing tank, white / coloured, syphonic action type, low level, valveless, with PVC inlet ball valve, PVC flush pipe, float and suitable sized brackets including cutting of floor / wall and making good to the disturbed surfaces in CM 1:3 with finishes to match with the existing and taking down of old PVC flush tank and disposing off complete all as specified and as directed
S&F flush pipe of polyethylene of low or high density or PVC 32mm dia, for low level cistern complete all as specified and as directed
S&F 15mm PVC connections, 450mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed
S&F 32/40mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/sqcm fixed to walls, ceilings or in floors, etc. complete all as specified and as directed
S&F stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75mm bore pipes complete all as specified and as directed
S&F vitreous China bowl urinal flat back half stall of size 465x355x265mm (minimum), white, with grating and union for discharge pipe, including providing fixing plugs, brackets, grating, union and connections to flushing pipe, bedding urinal against wall in CM 1:2, securing bowl with plugs and 60mm long brass screws, pointing around urinal bowl in white cement (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed
S&F in repairs vitreous China partition, 20mm thick, white, of size 310x700mm fixed with and including suitable stainless steel chromium plated bullet hinges 200mm long, etc. duly gouted in walls complete all as specified and as directed
S&F urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum weight 60gms) complete all as specified and as directed
M&L for laying pre-polished 80mm thick rubber moulded, double glossy, coloured, designer, interlocking tiles made of M-40 design mix concrete of approved design and shape with the crushing strength not less than 400kg/sqcm laid over and including 25mm thick (compacted thickness) sand bed (rate shall be included) complete all as specified and as directed
S&F in position aluminium-zinc colour coated high tensile alloy steel trap sheeting of 0.5 to 0.53mm thick, high rib, having 550 Mpa yeild strength BMT 0.45mm and zinc (galvanized) and aluminum combined coating of 150 gms/sqm (AZ-150) of 0.50mm TCT having top colour coat of regular modified polyester/silicon modified polyester/HDPE polyester of 18 to 20micron and back coat of 5 to7 micron epoxy primer fixes, RMR 1040 profile width 1125mm in roofing panels / sheeting complete as per manufacturer's instructions, all as specified and as directed Note: The sheet shall be fixed to MS angles with self drilling and self topping screws conforming to AS 3566 with moulded EPDM washers
Supply, laying, jointing, connecting and testing XLPE insulated, screened, 1100V (earthed) grade, screwed, PVC bedded, galvanised steel strip armoured electric power cable, conforming to IS: 7098 (Part-I) 1988, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls, etc. complete all as specified and as directed of the following sizes: Note: Excavation and earthwork, sand cushion, brick cover will be measured and paid separately under respective item herein
3.5 core 300sqmm
3.5 core 120sqmm
2 core 16sqmm
2 core 10sqmm
Supply, installation, testing & commissioning of powder coated compartmentalized (separate compartments for each MCCB), cubical LT panel, indoor type, conforming to IS-13947 and IP-54 protection class, of suitable size, front & back openable, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with 1500A rated copper bus bar, 4 pole, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 415V, 50Hz, 3 phase, 2 wire 1100V AC supply with gland plates, air vent gaskets / louvers, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) {painting exposed areas with two coats of synthetic enamel paint (of approved tint)} duly grouted in and including 100mm thick PCC 1:3:6 platform of suitable size (with 0.5m offset to all sides of panel/feeder), accommodating with and including the under mentioned and connecting up complete all as specified and as directed Notes: (i) Panel shall be procured from any of the makes detailed hereinafter (ii) The panel drawing shall be submitted by the Contractor from approved makes as listed for the approval of the Garrison Engineer
item No. 101 contd... Incoming (i) ACB 800A, 50kA, FP, 415V adjustable type manual draw out type- 2Nos. (ii) ACB bus bar coupler 800A, 50kA, 415V, 4 pole, adjustable type manual draw out type- 1No. (iii) Digital ampere meter 3 phase 0 to 800A square type- 01No. (iv) Digital volt meter 3 phase 0 to 500V square type- 01No. (v) Copper bus bar chamber 1200A capacity mounted on suitable insulators - 4Nos. (vi) Indicator lamp LED type RYB (set of three)
item No. 101 contd... Outgoing (i) MCCB three phase adjustable type with thermal magnetic release 630A 50kA FP adjustable with set of spreaders- 2Nos. (ii) MCCB three phase adjustable type with thermal magnetic release 315A 35kA FP adjustable with set of spreaders- 2Nos. (iii) MCCB three phase adjustable type with thermal magnetic release 100A 16kA FP- 6Nos.
M&L for cable jointing kit for 1.1kV earthed grade cable for end termination heat shrink joint indoor/outdoor type with jointing material and accessories suitable for 2 core, 16mm², XLPE insulated armoured aluminium conductor cable complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for end termination heat shrink joint outdoor type with jointing material and accessories suitable for 3.5 core, 120mm², XLPE insulated armoured aluminium conductor cable complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for end termination heat shrink joint outdoor / indoor type with jointing material and accessories suitable for 3.5 core, 300mm², XLPE insulated armoured aluminium conductor cable complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
Supplying, fixing / laying steel water tubing, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed of the following sizes:
80mm bore
40mm bore
S&F sheet metal enclosures for MCB distribution board 240V single pole and neutral 4 way double door, flushed inside the wall with 100Amps rated busbar including making good the disturbed surfaces also matching the exisiting surfaces complete all as specified and as directed
S&F sheet metal enclosures for MCB distribution board 240V single pole and neutral 4 way double door, flushed inside the wall with 200Amps rated busbar including making good the disturbed surfaces also matching the exisiting surfaces complete all as specified and as directed
Supply, installation, testing & commissioning of powder coated compartmentalized, cubical LT panel, conforming to IS-13947 and IP-54 protection class, of suitable size, front & back openable, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with 63A rated copper bus bar, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 240V, 50Hz, 1 phase, 2 wire 1100V AC supply with gland plates, air vent gaskets / louvers, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 25x25x4mm thick MS angle legs (4Nos.) duly grouted in and including 100mm thick PCC 1:3:6 platform of suitable size (with 0.5m offset to all sides of panel/feeder), painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer, accommodating with and including the under mentioned and connecting up complete all as specified and as directed with and housing the underlaid items: Note: The panel drawing shall be submitted by the Contractor from approved makes as listed for the approval of the Garrison Engineer
item No. 114 contd... Incoming: MCB of capacity 63A SPN 240V 50Hz 10kA -01No. Outgoing: MCB of capacity 32A SP 240V 50Hz 10kA -02Nos.
S&F MCB SPN 63A, 240V, B curve, 10kA complete all as specified and as directed
S&F MCB SP 32A, 240V, B curve, 10kA complete all as specified and as directed
S&F MCB SPN, 240V, 5 to 40A, 10kA, 'C' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed
S&F MCB SP, 240V, 5 to 40A, 10kA, 'C' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed
S&F MCCB 4P 315A 415V 50Hz 35kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F offload changeover switch 415V 630A 4 pole in sheet metal enclosure with side operating handle fixed on walls or inside panels with all connecting up complete all as specified and as directed
M&L for point wiring, concealed type, with 1.5sqmm single core multistranded copper conductor ZHFR PVC insulated and unsheathed cable 1100V grade drawn through and including rigid metallic steel ERW conduit, minimum 20mm dia, ISI marked and all conduit accesories concealed in wall/celing/roof, etc. with sunken type pressed steel/welded MS terminal boxes made out of 1.6mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings, switches, sockets outlets, regulators, etc. including provisining of 1.5sqmm ZHFR PVC insulated unsheathed cable 1100volt grade with multi-standed copper conductor to common earth dolly for earth wire for flame proof fittings complete all as specified and as directed
S&F flame proof rotary type switch with termination box in aluminium alloy LM6 FLP 16A 250V with wire guard complete all as specified and as directed
S&F flame proof weather proof LED tube light fitting 1x20W, 240V, 4' long, suitable for gas / vapour group IIA & IIB and zone 1&s, IP- 65 protection calss, with all accessories pre-wired and connecting with ZHFR grade twin core twisted flexible copper conductor cable and testing on installation complete all as specified and as directed
S&F flame proof, heavy duty, metalic body with metalic blades, legs, ISI marked energy efficient BEE five star rated exhaust fan, 457mm sweep, 1440RPM, CFM 4000 with lauvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including making hole on wall grouting bolts nuts washers, etc. complete all as speceified and as directed
S&F GI strip of size 32x6mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. complete all as specified and as directed
M&L for earthing using GI earthing with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 32x6mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
M&L for earthing with galvanised steel earth wire electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth wire 4sqmm to the extent of 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
Notes for serial item No. 127 & 128: (i) The cost of GI earth plate, GI continuity wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
Bairagi Builders
MAHESH GAUR AND CO.
M/s B.S.Jain
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .