Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC SHAMAL BECHAR S CHAWL SIDHANATH ROAD B H KHANDERAO MARKET VADODARA 390 001 GUJARAT | VADODARA | VADODARA | GUJARAT | 390001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹7.8 L+₹19,755 (2.60%)Rejected-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹9.1 L+₹1.5 L (19.9%)Rejected-AOC ARIHANT 15 A GOKUL SOCIETY SINDHWAL MATA ROAD PRATAPNAGAR VADODARA 390 004 | VADODARA | GUJARAT | 390004 | L3 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹23,000
Closing Date
22 Nov 2021, 6:00 pmClosed
GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2021_MES_485607_1
8637
Open Tender
Civil Works
Item Rate
120 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹23,000
Yes
8 Jan 2022
1 Nov 2021
29 Nov 2021
1 Nov 2021
22 Nov 2021
8 Nov 2021
2 Nov 2021 - 4 Nov 2021
Amount
Demolition of cement concrete (unreinforced) of any description and in any position and removing material from site complete.
M&L for Cement concrete type B1 1:2:4 (20 mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete.
Taking down cement plaster from brick / concrete surface including scrubbing down with water etc and M&L for 15 mm thick rendering in two layer on fair faces of brick work or concrete sur-faces of wall 05 mm thick in CM 1:4 mixed with WPC @ 3% by wt of cement for finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 (WPC will be measured and paid separately) complete.
M&L for 10 mm thick plaster on roof surface with CM 1:3 mixed with water proofing compound @3% by weight of cement and Plaster will be carried out such a manner when PCC padding is green and shall be finished even and smooth without using extra cement complete. (WPC will be measured and paid separately).
Supply only integral water proofing compound.
M&L for preparing surfaces of wall or exposed surfaces of cement concrete and applying two coats of Cement base paint over a coat of alkali resistant primer on extl wall surfaces complete .
Disconnecting existing tanks, exc. 250 and n. exc 500 ltrs setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete.
Disconnecting existing tanks, exc. 500 and n. exc 1000 ltrs setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete.
Dismantling of PVC water storage tanks and removing capacity from 500 to 1000 ltr complete
S&F for 500 Ltr capacity double layerd rotational moulded ployethyene water storage tank (cylindrical vertical with closed Top) hoisted and fixed in position complete.
S&F for 1000 Ltr capacity double layerd rotational moulded ployethyene water storage tank (cylindrical vertical with closed Top) hoisted and fixed in position complete.
Taking down steel tubing and connection 20mm dia including cleaning for refixing the same in new or old position fixed on wall and ceilings or laid in floors complete
Taking down steel tubing and connection 25mm dia including cleaning for refixing the same in new or old position fixed on wall and ceilings or laid in floors complete
Refixing only galvanised steel tubing 20mm dia (ISI marked) medium grade including all necessary fittings and fixed to wall / ceiling or laid in floor complete.
Refixing only galvanised steel tubing 25mm dia (ISI marked) medium grade including all necessary fittings and fixed to wall / ceiling or laid in floor complete.
S&F galvanised steel tubing 20mm dia (ISI marked) medium grade including all necessary fittings and fixed to wall / ceiling or laid in floor complete.
S&F galvanised steel tubing 25mm dia (ISI marked) medium grade including all necessary fittings and fixed to wall / ceiling or laid in floor complete.
S&F in replacement 25mm ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed complete.
M&L for complete removal of existing water proofing treatment including plaster, concrete padding or brick padding, roughening of concrete surface, cleaning and washing down the surface with water and removing debris/rubbish out side MD land complete.
M&L for 50 mm avg thick PCC padding in cement concrete type B0 (1:2:4) using 12.5 mm graded stone aggr mixed with WPC @ 2% by wt of cement finished surface even and smooth without using extra cement for laying of WPT complete. (WPC will be measured and paid separately).
M&L for water Proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm and laying Actetic PolyPropylene (APP) modified membrane pre fabricated, reinforced with non woven polyester of minimum 3.50 Kg/Sqm, 3 mm thick (minimum) with minimum 75 mm side over laps and minimum 100 mm end overlaps and applying one coat of aluminium paint @ 0.11 Kg/Sqm over APP membrane complete
Badri Electricals
Dagli Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .