Loading…
Loading…
Tender Value
₹93.3 L
EMD Value
₹1.9 L
Closing Date
25 Jun 2026, 12:00 pm
Replacement of various S&T gears(EPM, cable, relays, LC boom, Fire extinguisher etc.) in different sections over SEE Division.
SandT-SEE-E-OT-26-27-11
SandT-SEE-E-OT-26-27-11
Open
6 Months
Unknown (Unspecified Location)
₹0
₹1.9 L
1 Jun 2026
1 Jun 2026
11 Jun 2026
1-ANNEXURE - Z (Part-1) Non Schedule Items
Supply, Installation and Commissioning of rail head continuity bond by pinbrazing as per RDSO Spn. no. IRS: 103-2004 with latest amendment. as per technical specification attached. Inspection: Consignee Above/
Supply, Installation and Commissioning of TLJB lead wire bond ( 20 sq. mm. 2.5 mtrs long) by pinbrazing as per RDSO Spn no. IRS: 103-2004 with latest amendment. as per technical specification attached. Inspection: Consignee Above/
Supply, Installation and Commissioning of TLJB lead wire bond ( 4.5 mtrs long) by pinbrazing as per RDSO Spn no. IRS: 103-2004 with latest amendment.as per technical specification attached. Inspection: Consignee Above/
Supply of William stretcher Insulation set suitable for ground connection as per RDSO Drg No T-10367, T-10368, T-10384 and the spec IRS: S-23 and 40 with latest amendments. Inspection: Consignee Above/
Supply of Insulation Material for Gauge tie plate as per RDSO Drg No T-10372/Alt.2, T- 10371/ Alt.2, T-10368/ Alt, T-15083/88/ Alt 2 and T-11690/ Alt.2 and to IRS :S-23 and S-40. Inspection: Consignee Above/
Supply of insulating material for ground connection of EPM as per technical specification attached. Inspection: Consignee Above/
Supply of insulation for 'L'bracket for IRS type point machine fitting consisting of insulation plate-01 No, Ferrules-2 No, Washers-4 No (Material Nylon-66). Inspection: Consignee Above/
Supply of Terminal Blocks of flowing specification. Above/
"Supply of glass fuse 0.63A/1A/2A/4A/6A/10A/16A. Note:- Rating & requirement as specified by site incharge or as per direction of site incharge. Before supply, sample must be approved by consignee & controlling officer" Inspection: Consignee Above/
Supply of basic material to construct unit maintenance free earth as per RDSO Specs.No RDSO/SPN/197/2008 or latest and conforming to RDSO Drg.No. SDO/ RDSO/E&B/001dtd.19.09.08 . It consist of following: (a) Copper bonded steel electrode of 3.0 m long,17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 11 no. (b) Earth enhancement material supplied in sealed bags of minimum 10kg = 3 nos. © Copper strip of150x25x6 mm, to terminateearth rod= 1 no. (d) Copper strip of 300x25x6 mm (MEEB)= 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no.(f) Supply of 35 sq. mm multistrand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (g)Supply of 16 sq. mm multistrand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (h)Supply of 10 sq. mm multistrand single core PVC insulated copper cable as per IS: 694 for connecting various equipment's to SEEB (i) Supply of copper lug sleeve for 3/16 cable Inspection: RDSO Above/
Installation of Unit Maintenance Free Earth as supplied. It includes ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6mm x 200 mm to the earth electrodes. All material toolsand features required for weld will be arranged by contractor.(v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sqmm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and bus bars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum 12 copper bonding thickness of 250 micrones to made requirement of underwriter's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300mm x 25 mm x 6 mm formain equip- potential busbar, copper strips of 150 mm x 25mm x 6 mm sub equipotential busbar in relay room, power room and panel room. Copper strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300mm x300 mm x 300 mm(Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specn. No. RDSO/SPN/197/2008 or latest and conforming to RDSO Drg. No. SDO/RDSO/E&B/001 or latest & RDSO TAN 3006 ver3.0 dt. 30.06.2025. Above/
Painting of two coats of enamel paint over one coat of red oxide primer and there after numbering on the following items after scraping and cleaning of the surface where ever necessary .Primer and paints both Asian paint make are to be supplied by the contractor. Numbering is to be as per practice of the ECR and directives of the site Engineer. Above/
Supply of PBT fuse block with inserts cartridge type, to be mounted inside the location Box/Relay Rack. Above/
Supply & Execution of Sealed maintenance free VRLA battery Set of 60 cells (stackable) in combination of 55+5 For SMPS based integrated power supply system, Each cell of 2V/300AH capacity, fully charged, confirming to RDSO specification no. IRS-S-93/96(A) Amendment 1, complete with connecting links and suitably numbered in stackable racks along with user manuals.(Inspection agency- RDSO) Above/
Supply of GI boom as per RDSO Drg No. S-11600 1st section Suitable for Electrical Lifting Barrier As Per Spec No. RDSO/Spn/2008/2012 Ver. 2.0 or Latest. Note- Material should be supplied along with Test certificate from OEM and his warranty certificate. Before supply, sample must be approved by consignee & controlling officer. Inspection: Consignee Above/
Supply of GI boom as per RDSO Drg No. S-11600 2nd section Suitable for Electrical Lifting Barrier As Per Spec No. RDSO/Spn/2008/2012 Ver. 2.0 or Latest. Note- Material should be supplied along with Test certificate from OEM and his warranty certificate. Before supply, sample must be approved by consignee & controlling officer. Inspection: Consignee Above/
Supply of GI boom as per RDSO Drg No.S-11600 3rd section Suitable for Electrical Lifting Barrier As Per Spec No. RDSO/Spn/2008/2012 Ver. 2.0 or Latest. Note- Material should be supplied along with Test certificate from OEM and his warranty certificate. Before supply, sample must be approved by consignee & controlling officer. Inspection: Consignee Above/
Supply of GI boom (32 feet ) as per RDSO's Drg no. RDSO/S/11600 suitable for electric lifting barrier of Spec. No. RDSO/SPN/208/2012 Ver. 2.0. or latest) Inspection: Consignee Above/
Supply of Drill Bit HSS 9/32" as per technical specification attached. Inspection: Consignee Above/
Supply of True RMS Industrial Logging Multimeter with trend capture Make: Fluke 289 or similar as per technical specification attached. Inspection: Consignee Above/
"Supply of digital Cable fault locator for metallic S&T cables of reputed make . Model ANDIG5289 (or similar reputed make with similar or better specs) as per TECH SPN No. GR/TIE- 05/03,JULY 2006 & TEC73060:2006 or latest . Note-Item to be supplied after successful demonstration and approval of Railways. Technical compliance of OEM along with Make & Model certificate as per attached format must be submitted with offer." Inspection: Consignee Above/
Supply of PVC flexible copper cable single core multistrand 1 x 10 Sq.mm (80 conductor each diameter 0.40 +/-0.01) as per IS 694/2010 with latest amendment if any.with insulation thickness of 1.0mm nominal conductor resistance 1.91 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). Inspection: RDSO Above/
Supply of PVC flexible copper cable single core multistrand 1 x 16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.0 mm nominal conductor resistance 1.121 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). Inspection: RDSO Above/
"Supply and installation of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI Mark IS: 15683 operating temperature (-30°C to +55°C) for class 13 B type of fire with 1 mtr. Hose pipe fitted with PVC bent horn complete in all respect. Note:- BIS certification & Testing certification of NABL accredited Lab must be submitted by tenderer along with supply otherwise no payment will be made. " Inspection: Consignee Above/
"Supply of Fire ball as per following specifications :- (i)To be used for extinguishing fire with very less time of 3-5 Sec, (ii) Shelf life- Minimum 05 Yrs. (iii) Item Weight:- 1.3 Kg (Min) (iv) It should have a stand for keeping it. (v) Warrantee/Guarantee:As per OEM,(vi) GC/TC to be submitted along with the materials. Make: AFO, Elide fire or better Note-Technical compliance of OEM as per attached format must be submitted with offer. " Inspection: Consignee
Item Breakup - 1-ANNEXURE - Z (Part-1) Non Schedule Items
69.98 699800.00 Block for test and measurement 0.08 mm² - 2.5 mm² center marking with test slot for test plug 2 mm/0.079 in and 2.3 mm/0.091 in carrier rail din35 front entry cage clamp connection grey WAGO or Similar asper RDSO Spec. No. RDSO/Spn/189/2004 Ver. 3.0 or Latest. Inspection: RDSO
13.77 mm/0.098 in thick WAGO or similar as per RDSO Spec. No. RDSO/Spn/189/2004Ver. 3.0 or Latest. Inspection: RDSO
200.00 mm/0.039 in thickunslotted, yellow with chrome WAGO or similar as per RDSO Spec. No. RDSO/Spn/189/2004 Ver. 3.0 or Latest Inspection: RDSO
500.00 wide carrier raildin 35, grey WAGO or similar as per RDSO Spec. No.RDSO/Spn/189/2004 Ver. 3.0 or Latest. Inspection: RDSO Total 744420.00 "Supply & installation of following miscelleneous items of operating cum indication panel (Deltron make) i.e buttons, dominos, indication lamp , face cover plate etc. as per site requirement & as per Item- 15 instruction of railway site incharge. Note:-Material should be supplied along with Test certificate from OEM and his warranty certificate. Before supply, sample must be approved by consignee & controlling officer" S No. Item Description of Item Unit Qty Rate Amount No
200.00 2669.00 533800.00 and all accessories with face cover plate and writing. Inspection: Consignee
50.00 Yellow) Inspection: Consignee
50.00 2419.00 120950.00 complete and accessories (Grey Colour) Inspection: Consignee
5.00 2035.00 with prewiring and all accessories. Inspection: Consignee
50.00 control panel with complete button, wiring and collar . Inspection: Consignee
50.00 Inspection: Consignee
10.00 5013.00 accessories Inspection: Consignee Total 778455.00 Painting of two coats of enamel paint over one coat of red oxide primer and there after numbering on the following items after scraping and cleaning of the surface where ever necessary .Primer and Item- 16 paints both Asian paint make are to be supplied by the contractor. Numbering is to be as per practice of the ECR and directives of the site Engineer. SONPUR DIVISION-S AND T/EAST CENTRAL RLY S No. Item Description of Item Unit Qty Rate Amount No
120.00 1021.27 122552.40 with Aluminium paint. (a) Single case.
30.00 Aluminium paint. (b) Half case.
100.00 complete fitting as per ECRly standard practice.
50.00 complete (Point machine with black enamel only outside and ground connection with red oxide)
Numbers Total 503397.30 "Supply of following Components/Parts for Electrically Operated Lifting barrier as per RDSO SPEC NO. RDSO/ SPN/208/2012 (Ver 2.0) with latest amendment. Note- Material should be supplied along Item- 18 with Test certificate from OEM and his warranty certificate. Before supply, sample must be approved by consignee & controlling officer" S No. Item Description of Item Unit Qty Rate Amount No
10.00 9174.70 with base mounting suitable for operation of electric lifting barrier. Inspection: Consignee
30.00 6064.56 181936.80 with clutch bush, 44 teeth timing belt pulley, spring and adjusting nut. Inspection: Consignee
15.00 nos.) Inspection: Consignee Total 303640.70 Supply of PBT fuse block with inserts cartridge type, to be mounted inside the location Box/Relay Item- 19 Rack. S No. Item Description of Item Unit Qty Rate Amount No
229.19 229190.00 75/91(latest)) Inspection: RDSO Total 267865.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
I_CT_GCC-
ATTACHMENT
ACS1TO10.pdf
ATTACHMENT
Tender Notice
ATTACHMENT
Tender Document
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22_1.pdf
ATTACHMENT
T-26-27-11FullNotice-Rep.ofvariousgears-.pdf
ATTACHMENT
T-26-27-11TenderDocument-Rep.ofvariousgears.pdf
ATTACHMENT
Download all tender documents and submit your bid