Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.0 L+₹5.5 L (13.4%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹49.9 L+₹8.4 L (20.2%)Rejected-Finance 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹52.6 L+₹11.1 L (26.8%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹59.1 L+₹17.7 L (42.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
12 Jan 2023, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
REPAIR / ROUTINE MAINTENANCE OF FIRE FIGHTING SYSTEM / FIRE ALARM SYSTEM, EOT CRANE, DG SET AND ALLIED WORKS AT NAVAL AIR ENCLAVE UNDER GE NAVY PORBANDAR
2022_MES_564647_2
9143/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹78,000
Yes
4 Feb 2023
29 Dec 2022
14 Jan 2023
29 Dec 2022
12 Jan 2023
6 Jan 2023
30 Dec 2022 - 5 Jan 2023
Amount
Labour for Repair/Servicing /Overhauling to carry out maintenanace of diesel engine driving generating set of capacity 160 KVA, Model :- 6SL9088TA (Make - Kirloskar) . Checking thoroughly the Generator and finding out its faulty/defective parts and complete servicing /replacing following spares of the DG set including labour for replacement of defective spares as required to make the DG set 100% functional condition. Testing the DG set after repair to the entire satisfaction of Engr-in-charge. Note:- 1) Spare will be measured separately under relevant item of the schedule .
S& F in replacement of KOEL CARE Super Genuine Oil 13 Liters CAN Part Number :- 82.050.10.0.13.
S& F in replacement of SPINON LUBE OIL FILTER Part Number :- 06.436.01.0.00.
S& F in replacement of FUEL FILTER, 1.1 LIT, TWIN BOWL Part Number :- 48.117.10.0.00.
S& F in replacement of KOEL CARE GENUINE COOLANT PREMIX 5 LITRE CAN Part Number :- 82.020.35.1.05.
S& F in replacement of PRIMARY AIR FILTER ELEMENT Part Number :- 6H.411.02.0.00.
S& F in replacement of V BELT: (AVX13 X 1015 LENGTH) Part Number :- F6.019.17.0.00
S& F in replacement of V BELT: (AVX 13 X 1562 LENGTH) Part Number :- F6.019.16.0.00
S& F in replacement of BATTERY CABLE ASSEMBLY 21 SQ.MM Part Number :- 02.950.10.0.00
S& F in replacement of FUEL PIPE (RETURN) M12 X 1.5 MALE PLUG X M14 X 1.5 BANJO (700 MM) Part Number :- F6.708.12.0.00
S& F in replacement of HOSE ( FOR 160 KVA ) Part Number :- F6.255.46.0.00
S& F in replacement of PIPE FOR THERMOSTAT TO WATER TANK OF RAD. Part Number :- F6.680.04.0.00
S& F in replacement of HOSE FOR THERMOSTAT TO WATER TANK. Part Number :- F6.255.06.0.00
S& F in replacement of STICKER KIRLOSKAR GREEN POWER IDEAS 420X450MM. Part Number :- 2H.075.06.0.00
S& F in replacement of KIRLOSKAR GREEN BRAND STICKER 5M LENGTH. Part Number :- 2H.075.01.0.00
S& F in replacement of LEFT HAND LOCK WITH CATCHER (100 TO 600 KVA) .Part Number :- 06.598.03.0.00
S& F in replacement of VENT CONNECTION HOSE. Part Number :- F6.255.18.0.00
S& F in replacement of HOSE FOR AIR CLEANER. Part Number :- F6.980.01.0.00
S& F in replacement of AMARON BATTERY 12 V / 130Ah
M & L for FIP Calibration Suitable for Engine of Model F6.3208/0800023
M & L for taking out complete FIP assembly for overhauling from the DG Set, transportation to Original Equipment Manufacture (OEM) repair workshop for Servicing, opening /disconnecting all internal connection, cleaning the same, complete servicing as per Original Equipment Manufacture (OEM) Guidelines & Re-assembling the same and transportation back from workshop fixing the same on the DG Set and testing the DG Set Suitable for Engine of Model F6.3208/0800023.
M & L for Injector Calibration & Pressure Testing Suitable for Engine of Model F6.3208/0800023
M & L for Injector Overhaul Suitable for Engine of Model F6.3208/0800023
M & L for taking out Starter assembly from the DG Set, transportation to Original Equipment Manufacture (OEM) repair workshop for Servicing, opening/disconnecting all internal connection, cleaning the same, varnishing the armature with superior qualiy varnish, complete servicing as per Original Equipment Manufacture (OEM) Guidelines & Re-assembling the same and transportation back from workshop fixing the same on the DG Set and testing the DG Set Suitable for Engine of Model F6.3208/0800023.
M & L for Charging Alternater Servicing Suitable for Engine of Model F6.3208/0800023
M & L for Radiator Servicing Suitable for Engine of Model F6.3208/0800023
Labour for Repair/Servicing /Overhauling to carry out maintenanace of diesel engine driving generating set of capacity 50 KVA, Model :- 4R1190 (Make - Kirloskar). Checking thoroughly the Generator and finding out its faulty / defective parts and complete servicing /replacing following spares of the DG set including labour for replacement of defective spares as required to make the DG set 100% functional condition. Testing the DG set after repair to the entire satisfaction of Engr-in-charge. Note:- 1) Spare will be measured separately under relevant item of the schedule.
S& F in replacement of SPIN ON FILTER FOR LUBRICATING OIL Part Number :- 06.436.01.0.00
S& F in replacement of POLY V BELT Part Number :- 4H.1493.01.0.00
S& F in replacement of FUEL PIPE ( FUEL FILTER TO FUEL PUMP ) Part Number :- 4H.657.01.0.00
S& F in replacement of FUEL PIPE FEED PUMP TO FILTER Part Number :- 4H.031.05.0.00
S& F in replacement of SPIN ON FUEL FILTER (TWIN BOWL, 0.6 LIT.) Part Number :- 3H.132.10.0.00
S& F in replacement of FUEL FILTER ELEMENT PRIMARY Part Number :- 3H.132.01.0.00
S& F in replacement of FUEL FILTER SECONDARY ELEMENT Part Number :- 3H.132.02.0.00
S& F in replacement of KOEL CARE Super Genuine Oil 13 Liters CAN Part Number :- 82.050.10.0.13
S& F in replacement of KOEL CARE GENUINE COOLANT PREMIX 5 LITRE CAN Part Number :- 82.020.35.1.05
S& F in replacement of ASSEMBLY OF AIR CLEANER (AIR CLEANER + STRAP + RAIN CAP) Part Number :- 2H.277.20.0.00
S& F in replacement of PRIMARY AIR CLEANER ELEMENT Part Number :- 2H.277.05.0.00
S& F in replacement of FUEL PIPE M14 X M14 B, PARALLEL,750 L , 9.0 I.D.,SAE 100 R6 Part Number :-4H.896.07.0.00
S& F in replacement of FUEL PIPE ( RETURN ) M12 X 1.5 MALE PLUG X M14 X 1.5 BANJO (700 MM) Part Number :- F6.708.12.0.00
S& F in replacement of BATTERY CABLE ASSEMBLY 21 SQ.MM Part Number :- 02.950.10.0.00
M & L for FIP Calibration Suitable for Engine of Model 5H.3022/1000462
M & L for taking out FIP assembly from the DG Set, transportation to Original Equipment Manufacture (OEM) repair workshop for Servicing, opening / disconnecting all internal connection, cleaning the same, complete servicing as per Original Equipment Manufacture (OEM) Guidelines & Re-assembling the same and transportation back from workshop fixing the same on the DG Set and testing the DG Set Suitable for Engine of Model 5H.3022/1000462
M & L for Injector Calibration & Pressure Testing Suitable for Engine of Model 5H.3022 / 1000462
M & L for Injector Overhaul Suitable for Engine of Model 5H.3022/1000462
M & L for taking out Starter assembly from the DG Set, transportation to Original Equipment Manufacture (OEM) repair workshop for Servicing, opening / disconnecting all internal connection, cleaning the same, varnishing the armature with superior qualiy varnish, complete servicing as per Original Equipment Manufacture (OEM) Guidelines & Re-assembling the same and transportation back from workshop fixing the same on the DG Set and testing the DG Set Suitable for Engine of Model 5H.3022/1000462 Note:- Rate is inclusive of all genuine spares required during repair of starter. Note:-Contractor has to submit Test & Calibration Report obtained from the Original Equipment Manufacture (OEM) Service Centre
M & L for Charging Alternater Servicing Suitable for Engine of Model 5H.3022/1000462
M & L for Radiator Servicing Suitable for Engine of Model 5H.3022/1000462
Note for Servicing items of the Schedule Item NO 1.00 & 2.00 Note:- 1) The above Item Includes following a) Labour Charges tools / gauges for Major and Minor repairs including Overhauls b) Labour charges for all unlimited Breakdown Complaints related to Genset for a period of one year c) Preventive Maintenanace 4 visit in a year (qtrly based) to carry out Inspection of 61 Check points of DG sets As per Annexure 'A' attached & submission of Test Report duly signed by Engr-In-Charge, Authorised Kirloskar Care Service Partner & Contractor for every qtrly Visit. Note:- 2) The above Item excludes following a) Cost of consumables and spares parts require for preventive or breakdown Visits b) Charges for external job works like FIP-Starter-Charging alternator repairing, AC Alternator Repairing, Machining required for any part of Genset. Note :-3) The Spare Parts, engine Oil & Premix Coolant used for work under contract must be 'Kirloskar Care' genuine / recommended by OEM Purchased from Authorised Kirloskar Care Service & Spare Dealership. Note:-4) All works under contract must be carried out by Kirloskar Trained Service Engineers from Local Autorised Kirloskar Care Service & Spare Dealership to have a quick /urgent hastle free service to restore the system in minimum time frame. Note:-5) The Minor Brakdown Complaints will be attended within 4 Hrs & should be rectified 24 Hrs by Kirloskar Trained Service Engineers from Local Autorised Kirloskar Care Service & Spare Dealership. Note:-6) Contractor has to collabrate with "Kirloskar Bandhan" 1 Year Service Package (4 Visits qtrly based) from KOEL CARE after acceptance of contract.
Labour for Repair/Servicing /Overhauling to carry out maintenanace of diesel engine driving generating set of capacity 160 KVA, Model :- 6G11TAG24 (Make -GREAVES COTTON). Checking thoroughly the Generator and finding out its faulty/defective parts and complete servicing / replacing following spares of the DG set including labour for replacement of defective spares as required to make the DG set 100% functional condition. Testing the DG set after repair to the entire satisfaction of Engr-in-charge. Note:- 1) Spare will be measured separately under relevant item of the schedule.
S& F in replacement of LUBE OIL FILTER(232V12) Part Number :- 605411880008
S& F in replacement of GREAVES LUBE OIL20 L CI-4 Part Number :- 123200198634
S& F in replacement of PRIMARY ELEMENT A/F Part Number :- 105413100157
S& F in replacement of SECONDARY ELEMENT A/F Part Number :- 105413100158
S& F in replacement of FILTER ELEMENT WITH O RING Part Number :- 1200240911
S& F in replacement of FLTER INSRT WITH O RING Part Number :- 1200240912
S& F in replacement of BATTERY CABLE ASSEMBLY 21 SQ.MM Part Number :- 02.950.10.0.00
M & L for Fuel Pump Servicing Suitable for Engine of Model 02.950.10.0.00
M & L for Nozzle Servicing Suitable for Engine of Model 02.950.10.0.01
M & L for Turbo Charging Servicing Suitable for Engine of Model 02.950.10.0.02
M & L for Radiator Servicing Suitable for Engine of Model 02.950.10.0.02
Labour for Repair/Servicing/Overhauling to carry out maintenanace of diesel engine driving generating set of capacity 40 KVA, Model :- 3G11AG25 (Make -GREAVES COTTON). Checking thoroughly the Generator and finding out its faulty/defective parts and complete servicing /replacing following spares of the DG set including labour for replacement of defective spares as required to make the DG set 100% functional condition. Testing the DG set after repair to the entire satisfaction of Engr-in-charge. Note:- 1) Spare will be measured separately under relevant item of the schedule.
Labour for Repair/Servicing/Overhauling to carry out maintenanace of diesel engine driving generating set of capacity 40 KVA, Model :- 3G11AG25 (Make -GREAVES COTTON). Checking thoroughly the Generator and finding out its faulty/defective parts and complete servicing /replacing following spares of the DG set including labour for replacement of defective spares as required to make the DG set 100% functional condition. Testing the DG set after repair to the entire satisfaction of Engr-in-charge. Note:- 1) Spare will be measured separately under relevant item of the schedule.
S& F in replacement of ELEMENT SINGLE FUEL FILTER Part Number :- 700000793493
S& F in replacement of GREAVES LUBE OIL CI4 -10 LTR PACK Part Number :- 123200198624
S& F in replacement of ELEMENT PRIMARY FILTER (DRY) Part Number :- 700000793450
S& F in replacement of ELEMENT SECONDARY FILTER Part Number :- 700000793451
M & L for Fuel Pump Servicing Suitable for Engine of Model :- 700000793451
M & L for Nozzle Servicing Suitable for Engine of Model 700000793451
M & L for Turbo Charging Servicing Suitable for Engine of Model 700000793451
M & L for Radiator Servicing Suitable for Engine of Model 700000793451
S &F in replacement of Exide Xpress Battery 12V / 88AH complete all as specified and directed by Engineer-in-Charge.
Note for Servicing items of the Schedule Item No. 3 to 4 :- Note:- 1) The above Item Includes following a) Labour Charges tools/gauges for Major and Minor repairs including Overhauls b) Labour charges for all unlimited Breakdown Complaints related to Genset for a period of one year c) Preventive Maintenanace 4 visit in a year (qtrly based ) to carry out Inspection of 61 Check points of DG sets As per Annexure 'A' attached & submission of Test Report duly signed by Engr-In-Charge, Authorised Greaves Cotton Ltd Service Partner & Contractor for every qtrly Visit.
Note:- 2) The above Item excludes following a) Cost of consumables and spares parts require for preventive or breakdown Visits b) Charges for external job works lke FIP-Starter-Charging alternator repairing, AC Alternator Repairing, Machining required for any part of Genset.
Note :-3) The Spare Parts, engine Oil & Premix Coolant used for work under contract must be 'Greaves Lub Oil ' genuine / recommended by OEM Purchased from Authorised Greaves Cotton Ltd Service & Spare Dealership.
Note:-4) All works under contract must be carried out by Greaves Cotton Ltd Trained Service Engineers from Local Authorised Greaves Cotton Ltd Service & Spare Dealership to have a quick /urgent hastle free service to restore the system in minimum time frame
Note:-5) The Minor Breakdown Complaints will be attended within 4 Hrs & should be rectified 24 Hrs by Greaves Cotton Ltd Trained Service Engineers from Local Authorised Greaves Cotton Ltd Service & Spare Dealership.
Note:-6) Contractor has to collabrate with "Greaves Cotton Ltd" 1 Year Service Package (4 Visits qtrly based ) from Authorised Dealer of Greaves Cotton Ltd after acceptance of contract.
S& F in replacement of Butterfly valve PN16 conforming to IS:13095/BS :5155 with Flanges, Gl Nut bolts, Gaskets etc complete testing / commissioning after installation of following size all as specified and directed by Engineer-in-Charge.
200 mm dia
150 mm dia
100 mm dia
S& F in replacement of C.l. Dual plate type Non-Return Valve class PN 16 rating with fittings, flanges, nutbolts, washers, gaskets etc complete testing / commissioning after installation of following size all as specified and directed by Engineer-in-Charge.
150 mm dia
80 mm dia
S& F in replacement of Gunmetal, Single Headed Fire Hydrant Valve with 80 mm N.B. flanged inlet, 63 mm dia female instantaneous outlet type. S.S. coupling, blank cap, chain, twist release type lug & all accessories Conforming to IS:5290. Including fixing with supports, flanged tapping from wet riser, orifice plate complete all as specified and directed by Engineer-in-Charge.
S& F in replacement of non-percolating rubber reinforced lined fire Hose pipe (as per IS : 636) of 63 mm dia and 2x15 mtrs long. The hose shall be rated for burst pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked SS male & female coupling (IS:903) bound & riveted to hose pipe with copper rivets & 1.5 mm copper wire complete all as specified and directed by Engineer-in-Charge.
S& F in replacement of 150 mm dia Pressure Gauge of range 0 - 16Kg / cm 2 conforming to IS - 3624 having bourdon tube of stainless steel 310 in cast aluminium, stove enameled, black, weather proof case with outer, screwed aluminumbezel and complete with necessary U-type stainless steel siphon tube and cock including providing suitably painted angle iron support to the tube etc.as per specification complete all as specified and directed by Engineer-in-Charge.
S& F in replacement of Pressure switch in the MS pipe Line including connection etc. as required. Providing and fixing pressure transducer complete all as specified and directed by Engineer-in-Charge.
S& F in replacement of of Manual call , Hooter point complete all as specified and directed by Engineer-in-Charge.
S& F in replacement of of Smoke detecter & heat detecter, point complete all as specified and directed by Engineer-in-Charge.
S& F in replacement of of C.I. dirt box strainer 200mm bore for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS: 2373
S& F in replacement of of MS ERW pipe 32 mm bore confirming to IS 1239/3589 duly coated with synthetic enamel paint of required shade complete as directed by Engineer-in-Charge.
M& L for scrapping, making good finish surface & painting of existing MS ERW pipe with synthetic enamel paint of required shade as per fire norms for following size complete as directed by Engineer-in-Charge.
100 mm dia
80 mm dia
Labour for Repair/Servicing /Overhauling to carry out maintenance of diesel engine driving generating set of capacity 69.1 KW, Model :- 4G11T (Make -Greaves Cotton). Checking thoroughly the Fire Engine and finding out its faulty/defective parts and complete servicing /replacing following spares of the Fire Engine including labour for replacement of defective spares as required to make the Fire Engine 100% functional condition. Testing the Fire Engine after repair to the entire satisfaction of Engr-in-charge. Note:- 1) Spare will be measured separately under relevant item of the schedule .
S& F in replacement of FILTER ELEMENT WITH O RING Suitable for Model :- 4G11T (Make -Greaves Cotton)
S& F in replacement of FLTER INSRT WITH O RING Suitable for Model :- 4G11T (Make -Greaves Cotton)
S& F in replacement of LUB OIL FILTER(232V12) Suitable for Model :- 4G11T (Make -Greaves Cotton)
S& F in replacement of AIR FILTER ELEMENT PRIMARY 8" (XRB08) Suitable for Model :- 4G11T (Make -Greaves Cotton)
S& F in replacement of AIR FILTER ELEMENT SAFETY 8" (XRB08) Suitable for Model :- 4G11T (Make -Greaves Cotton)
S& F in replacement of GREAVES LUBE OIL 20 L CI-4
S& F in replacement of RADIATOR PRE-MIX GREAVES TOOL 10 LIT
S& F in replacement of Set of hoses Suitable for Model :- 4G11T (Make -Greaves Cotton)
S& F in replacement of PIPE, FIP OIL SUPPLY Suitable for Model :- 4G11T (Make -Greaves Cotton)
S& F in replacement of LEAK OFF PLASTIC 4G11 STD Suitable for Model :- 4G11T (Make -Greaves Cotton)
S& F in replacement of COGGED BELT AX43-1143L Suitable for Model :- 4G11T (Make -Greaves Cotton)
S& F in replacement of LOP SWITCH 2.5Kg/Sqcm Suitable for Model :- 4G11T (Make -Greaves Cotton)
S& F in replacement of W T.SWITCH 95+/-2DegCel Suitable for Model :- 4G11T (Make -Greaves Cotton)
S& F in replacement of FUEL OFF SOLENOID-12VDC(PULL TO STOP) Suitable for Model :- 4G11T (Make -Greaves Cotton)
Disconnecting the electric connection from motor terminal box including insulating the ends of the cable, taking out pump set from base after opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gaskets, assembling the pump with replacement of pulley key, gland packing rope, greasing, transporting back to site and fixing on the existing foundation, connecting the electric connection of motor and testing complete to entire satisfaction of Engr-in-charge for the following capacity. (Note :- Major spare parts shall be measured and paid separately, minor spares deemed to in rate quoted, spares like pump shaft, impeller and bearing only will be measured and paid separately under relevant items.
Fire pump set of capacity 80 HP , 415 volt, 3 phase 50Hz. AC
Jockey pump set of capacity 15 HP, 415 volt, 3 phase 50Hz. AC
S& F in replacement of MCCB 125 amps 3 Pole , 415 Volts complete all as specified and directed by Engineer-in-Charge.
S& F in replacement of 3 Pole power contactor conforms to IS /IEC 60947-47-1, type MNX 70 .Make L& T/ Legrand/Schenider
S& F in replacement of 3 Pole power contactor conforms to IS /IEC 60947-47-1, type MNX 45 .Make L& T/ Legrand/Schenider
S& F in replacement of Add -on aux contact block 2NO+2NC type MNX -A2 .Make L& T/ Legrand/Schenider
S& F in replacement of Add -on aux contact block 1NO+1NC type MNX -A2 .Make L& T/ Legrand/Schenider
S& F in replacement of S.S. Single Headed Fire Hydrant Valve with 80 mm N.B. flanged inlet, 63 mm dia female instantaneous outlet type. S.S. coupling, blank cap, chain, twist release type lug & all accessories Conforming to IS:5290. Including fixing with supports, flanged tapping from wet riser, orifice plate complete as specified and directed by Engineer-in-Charge.
M & L for servicing,testing ,cleaning of S.S. Single Headed Fire Hydrant Valve with 80 mm N.B. flanged inlet,63 mm dia female instantaneous outlet type, replacing its worn out gasket , rusted nut bolts, filling of packing and making it in serviceable condition in order to have smooth & hastle free operation all as required complete as directed by Engineer-in-Charge.
S& F in replacement of 63 mm dia instantaneous pattern SS short branch pipe, 20 mm dia nozzle conforming to IS 903,suitable for inter connection to hose pipe coupling complete as specified and directed by Engineer-in-Charge.
M & L for servicing,testing ,cleaning of of 63 mm dia instantaneous pattern SS short branch pipe, nozzle , and making it in serviceable condition in order to have smooth & hastle free operation all as required complete as directed by Engineer-in-Charge.
S& F in replacement of Weather proof Standard Fire Hose Cabinet wall mounting type (400 mm x 450 mm x 250 mm deep) having single or double opening with necessary locking arrangement by allan key suitable for housing 2 nos. hose pipe, 1no. Branch pipe & nozzle spanner complete as specified and directed by Engineer-in-Charge.
Material and Labour for painting of fire hydrant/fire hose box of any size with one coat of red oxide and two coats of synthetic enamelled paint of FIRE RED colour complete with all fittings etc all as specified and directed by Engineer-in-charge.
S& F in replacement of First Aid Hose Reel equipment conforming to IS:884 comprising of hose reel drum, 8 mm shut off nozzle, Rubber Nos .hose of 25 mm dia x 30 mtr. long, painting, swinging type fixing bracket, anchor fastener, bolts & nuts etc. complete as specified and directed by Engineer-in-charge.
S& F in replacement of 4 way & 2 way fire brigade connection (FBC) of CI body with2 nos. S.S male instantaneous inlet couplings complete with cap and chain as required for 150mm dia MS pipe connection, confirming to all as specified and directed by Engineer-in-charge.
M& L for Refilling of 6 Kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Controllable discharge mechanism Class A Rating 3A & Class B rating 21B as per IS 15683 ISI MARK (ABC Dry Chemical Powder - MAP 50%) all as specified and directed by Engineer-in-charge.
M& L for Refilling of 9 liter Water CO2 Fire Extinguisher Mono Ammonium Phosphate Cartatge, Stored Pressure Type, Pressure Gauge, Controllable discharge mechanism Class A Rating 3A & Class B rating 21B as per IS 15683 ISI Mark all as specified and directed by Engineer-in-charge.
M& L for Refilling of CO2 type Fire Extinguisher of capacity 4.5 kg filled with Co2 Gas as per IS 15222 with control discharge mechanism, fitted with Hose & Horn applicable on Class B fire rating 21B confirms to IS 15683 bearing ISI mark. Co2 cylinder as per IS 7285 all as specified and directed by Engineer-in-charge.
S& F in replacement of water moniter 63 mm Firetech fire monitors are robust products designed with advanced technology and have been tested to provide the high-quality water jet and fog patterns. Firetech Monitors have huge range covering flows from 750 gpm to 2000 gpm made of Stainless-Steel body. Firetech fixed monitors all as specified and directed by Engineer-in-charge.
M & L for servicing,testing ,cleaning of water moniter 63 mm Firetech fire monitors including cleaning of nozzles, Changing of oil , repairing of fog nozzles, replacement of its unserviceable spares etc and complete testing after overhauling & repairs making it in serviceable condition in order to have smooth & hastle free operation all as required complete as directed by Engineer-in-Charge.
M & L for servicing,testing ,repairing of Low expansion foams have the lowest viscosity, or thickness/consistency, and expand at a ratio of between 2 to 1 and 20 to 1. Medium expansion foams expand at a ratio of 20 to 1 and 200 to 1, High expansion foams have an expansion ratio above 200 to 1 replacement of its unserviceable spares etc and complete testing after overhauling & repairs making it in serviceable condition in order to have smooth & hastle free operation all as required complete as directed by Engineer-in-Charge.
S& F in replacement of foam nozzle size 32 mm complete as directed by Engineer-in-Charge.
Rountine comprehensive maintenance for complete inspection /checking throughly the entire fire fighing system finding out and repairing faults if any making it 100% functional testing the fire system and submitting report of testing for its functionality after entire satisfaction for every visit. The comprehensive maintenance includes entire fire detection & fire fighting system from pump house to fire fighting area, replacement of parts mentioned other than in respective items of this schedule. Comprehensive maintenance includes checking of all electrical cables components from main control panel to zonal fire panel, mechanical fire fighting parameter such as checking of pumpset connections , complete oiling greasing in bearings, couplers etc,servicing of all inlet valves including replacement of gland packing, making pumpset on and run pumpset for full capacity at lease 15 mins, checking hydrant system, checking of hooters, alarm system, checking of hydrant pump, diesel engine pump set, jockey pump, throw of yard monitors, foam generator, water pressure etc., servicing complete all as directed by Engineer-in-Charge. Note:- Comprehensive maintenance will be carried out through a specialist authorised fire fighting agency and documents to this aspect be submitted before claiming payment.
Material and labour for cleaning of underground fire pump house sump by draining out the water after pumping by arranging re-watering pumps or by manual and wash the walls & bottom surface by high pressure spray of approximating 195 PSI with rotary water jet pumps and removing the sludge and foreign matters complete by and socking out the fixing with high pressure wet vacuum pumps scrubbing the wall and cleaning the entire sump including disinfectioning the tanks with spray of chemical approach by concerned authorities complete all as directed by the Engineer-in-Charge
Taking down unserviceable U/G cable from trenches, wall, floor etc and removing to store for safe custody above 35 sqmm upto 120 sqmm complete all as specified and directed. Note:- Excavation for taking will not paid for separatly, the cable shall be deemed to have taken down from the trenches excavated for laying of cables.
S& F in replacement of XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 V grade laid in trenches/through GI pipes /ductsHDPE Pipe including testing complete of following cross section area and size (Note:- Rate is inclusive of cable gland & cable lugs)
Cross section area 120 sqmm 3.5 core
Cross section area 95 sqmm 3.5 core
Cross section area 70 sqmm 3.5 core
Excavation in trenches in hard /dense soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested, complete all as specified and directed.
Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
S& F in replacement of laying of Double Walled Corrugated (DWC) HDPE pipe of size 90/75 mm outer/inner dia of conforming to IS 16205 Part -24 including necessary bends,coupling ,tees, reducers, spacers,end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge
S& F in replacement of Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 100 mm dia along with necessary clamp duly painted with silver aluminuim paint nut bolt etc, including PVC bend of required size for cable entry at bottom of pole complete all as specified and directed.
S& F in replacement of Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 80 mm dia along with necessary clamp duly painted with silver aluminuim paint nut bolt etc, including PVC bend of required size for cable entry at bottom of pole complete all as specified and directed.
S& F in replacement of repair Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 50 mm dia along with necessary clamp duly painted with silver aluminuim paint nut bolt etc, including PVC bend of required size for cable entry at bottom of pole complete all as specified and directed.
S& F in replacement of Sheet metal enclosure suitable to accommodate MCCB 160 Amps 4 pole, upto 185 sqmm 3.5 core cable complete all as specified and directed.
S& F in replacement of MCCB 160 Amps 4 Pole 25 ka with thermal magnetic release complete all as specified and directed.
M & L for Cutting the existing PCC floor/road/foot path not exeeding 15cm width,30 cm depth for laying of UG cable/protection of pipe complete all as specified and directed.
M & L for PCC type B1,1:2:4 using 20 mm graded stone aggregate complete all as specified and directed.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces complete all as specified and directed.
S& F in replacement of Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVC CASING CAPING/PVC Conduit not less then 25mm dia medium Grade fixed on walls/roof/floors complete all as specified and directed by Engineer in Charge. Notes:- Two wires of 4 sqmm and one wire of 4.0 sqmm and one run of PVC casing caping/Conduit shall be measured as one unit.
Dismantling unserviceable main switch/ kitkat DBs/ MCB including wooden board from existing position and making good disturbed surfaces of wall to match with existing surfaces complete all as specified and directed.
S& F in replacement of MCCB DB VERTICAL TYPE made of sheet steel , powder painted with NEUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade ,Glazed door 415 Volts TPN with 8 way Double door complete all as specified and directed.
S& F in replacement of MCB DB made of sheet steel , powder painted with NEUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade, 415Volts TPN with 6 way Double door complete all as specified and directed.
NOTE FOR ITEM NO 56 & 57 - (1) The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall./ DB to be fixed on wall including frame made out of MS flat 40x5mm (2).The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface, including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes making good disturbed surfaces of walls, etc)
S& F in replacement of MCCB TPN 125 Amps , 415Volts, 16 KA complete all as specified and directed.
S& F in replacement of MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 40 to 63 Amps complete all as specified and directed.
S& F in replacement of MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 25 to 63 Amps complete all as specified and directed.
S& F in replacement of MCB SP 240 Volts 'C' series, breaking capacity 10 KA of rating 6-32 Amps complete all as specified and directed.
M&L Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of 1991 (part-I) complete all as specified and directed.
S& F in replacement of earth enclosure with 2 pin earth plug sokcet complete with MCB SP 25 amp, flush mounting type complete all as specified and directed.
M&L for preventive maintenance consisting of normal repairs and locating the fault in Flame Proof type EOT Crane of capacity 5 Ton including making all electrical control and mechanical mechanism like gearbox, motor, plumber block, wheels for LT & CT motion, control panel brakes system, limit switch serviceability, tightening of all nut bolts, setting/adjusting of any disbalanced mechanical mechanism, checking electrical connection/control switches/ relays/ contactors and wiring, tightening loose connection, functional and making the free movement of entire unit as specified and as directed. details of cranes are as under: a) Capacity 05 Ton Span-44.5Mtr Hook Lift - 6.0 Mtr Indoor type [Flame proof type] – 01 Nos Make :- ROCKWELL HOISTO CRANES PVT LTD. Note 1 : All Spares other then those included Sch A are deemed to be included the rate quoted by the contractor for comprehensive/routine maint. Note 2. The load testing shall be carried out by authorised rep of Govt authorised agency, the testing shall be carried out within 60 days from date of commencement. Note 3 : Load and arrangement required shall be arranged and load test charges are deemed to be included in quoted rates. Note 4: Any breakdown during concurrency of contract shall be repaired by contractor within 48 hrs without any extra cost to govt.
M&L for scrapping and cleaning the old painted surfaces of entire exposed parts of Flame Proof Type EOT crane of capacity 5 Ton and Span 44.5m (Approx) with wire brushes etc. including removing oil & grease stains using appropriate cleaning agents and applying two spray coats of synthetic enamel golden yellow paint all as directed.
S& F in replacement of Long Travel Electro Hydraulic Thruster brake 160mm suitable for 5 Ton FLP EOT crane as per existing size complete all as specified and directed.
S& F in replacement of LT(Long Travel) & CT(Cross Travel) limit switch for 5 Ton capacity FLP EOT crane complete all as specified and directed.
S& F in replacement of CT & LT cable trolleys for 5 Ton FLP EOT Crane along with proper alignment of cable trolley as per existing size for EOT crane complete all as specified and directed.
S& F in replacement of Wire rope 12mm for 5 Ton Crane as per existing size for EOT crane complete all as specified and directed.
S& F in replacement of FLP CT wheel for 5 Ton Crane as per existing size for EOT crane complete all as specified and directed.
S& F in replacement of transformer mounted in control panel of 230/110V for EOT crane upto 5.0 Ton complete all as specified and directed.
S& F in replacement of Rotary limit switch 3 phase 415 volt 50 Hz, for EOT crane complete all as specified and directed.
S& F in replacement of Over load Relay for hoist for EOT cranecomplete all as specified and directed.
S& F in replacement of Over load Relay for CT/LT for EOT crane complete all as specified and directed.
S& F in replacement of Couplng Pinion for EOT crane complete all as specified and directed.
S& F in replacement & Dressing of cable trolley with trolley chain for EOT crane complete all as specified and directed.
BABUBHAI BHIMABHAI PANDAVADRA
shree chamunda enterprise
JAY BHARAT METAL SUPPLIERS
M/S Rajendra Constructions
RUDRAAY CONSTRUCTION
Vijay Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .