Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹40.6 L Quoted ₹40.9 L | L1 | Accepted-AOC LOWEST REASONABLE BID |
| 2 | L2₹42.9 L+₹1.9 L (4.70%)Rejected-Finance | ₹42.9 L+₹1.9 L (4.70%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹43.3 L+₹2.4 L (5.87%)Rejected-Finance | ₹43.3 L+₹2.4 L (5.87%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹44.3 L+₹3.4 L (8.35%)Rejected-Finance VILL BHAISORA POST CHINHAT DISTT LUCKNOW UP | ₹44.3 L+₹3.4 L (8.35%) | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹57 L
EMD Value
₹1.1 L
Closing Date
26 May 2025, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
SPL REPAIR TO OTM BLDG NO. 132 AT ARMY AREA JODHPUR UNDER GE (ARMY) NO. 01
2025_MES_704751_1
82425/134/E8
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (ARMY) NO. 01 JODHPUR
₹1.1 L
Yes
3 Jul 2025
19 Apr 2025
2 Jun 2025
19 Apr 2025
26 May 2025
12 May 2025
21 Apr 2025 - 10 May 2025
Amount
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified & directed by Engineer-in-charge.
Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness and removing debries and rubbish from site outside the MoD land complete all as specified & directed by Engineer-in-charge.
M&L non skid ceramic coloured joint free tiles 6 to 7 mm thick of size area exc 0.11Sqm but nexc 0.18 Sqm in floors etc set jointed in neat cement slurry and pointed in white or coloured cement to match the shade including 15 mm thick screed bed in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
M&L for glazed colour ceramic tiles of size 450x300x7mm, laid in vertical surface dado/skirting joint free etc, set and jointed in neat cement slurry and pointed in coloured tiles to match the shade of tiles over 10 mm thick rendering in CM1:3 over stone masonry surfaces & finished even & rough to receive tiles complete all as specified & directed by Engineer-in-charge.
M&L for non-skid coloured ceremic tiles joint less 7 to 8 mm thick area of each tiles exceeding 0.18 Sqm but n.exc. 0.38 sqm in floor etc set jointed in neat cement slurry and pointed in white or coloured cement to match the shade including 15 mm thick screed bed in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
Taking down carefully cement concrete/ spalled out concrete from RCC roof projections,Ceilings,Sunshades,beams,Columns etc upto cover depth by chipping out lightly including necessary scaffolding etc complete all as specified & directed by Engineer-in-charge.
M&L for cleaning the existing reinf of slabs chajjas , Columns etc & applying a coat of SIKA RUSTOFF 11 or equivalent of pidilite,fosroc,Thermax etc to remove rust particles etc throughly cleaning the surface complete all as specified & directed by Engineer-in-charge.
M&L for applying a coat of bond coat made with cement slurry(1part cement to 1.5-2parts water) mixed with admixture LATEX POWER or equivalent mixed @5 Kg per 50kg of cement & applying to the concrete surfaces @200gm/sqm to obtain tack complete all as specified & directed by Engineer-in-charge.
S&F GI chicken wire mesh of 0.71mm dia wire & 12mm mesh size fixed with nails & screws around RCC chajjas/fascias etc complete all as specified & directed by Engineer-in-charge.
M&L for 15-20mm thick rendering in CM 1:1:2 using 1 part cement to 1part 2-3mm screenings of stone agg & 2 parts coarse sand over the bond coat applied surfeces with cement mixed SIKA PLASTOCRETE admixture or equivalent of pidilite,fosroc,Thermax etc @100gm/50kg of cement & finishing the surfaces even & rough to recieve final rendering coat complete all as specified & directed by Engineer-in-charge.
M&L for 10-15mm thick rendering in CM 1:3 over the bond coat applied surfeces with cement mixed SIKA PLASTOCRETE SUPER admixture or equivalent @100gm/50kg of cement & finishing the surfaces even & smooth complete all as specified & directed by Engineer-in-charge.
M & L for mild steel framed work as in brackets etc for cooler stands,supportings frame work for sun shade etc framed steps/stairs etc complete using MS railing/angle iron Steel bars gusset plate etc conforming to Fe 290 Gde E-165 complete all as specified & directed by Engineer-in-charge.
Dismantling of wall and ceiling board (fibre, pulp, insulation, etc) or insulation board/slabs /blankets of any thickness including cover fillets complete all as specified & directed by Engineer-in-charge.
S&F anodised aluminium snap grid frame work of pre powder coated pre fabricated GI section (Including hangers) for false ceiling of size 600x600mm with ceiling board of PVC laminated gypsum board 10-12 mm thick and fixed as per manufacturer instruction including as per sample approved by GE , complete all as specified & directed by Engineer-in-charge.
M&L Exposing existing RCC members such as columns, slabs, lintels, beams, etc, upto the main reinforcement carefully by means of chisel and hammer, wire brushes or by any other mechanical means so as to remove all deteroit concrete and cleaning the surface to remove all loose dust particels, etc and make the surface ready to receive chemical treatment in specified condition complete all as specified & directed by Engineer-in-charge.
M&L for 30 mm thick guniting in patches on to the required area on RCC/PCC columns, beams, stairs, lintels, retaining walls, sunshades, roofinf slabs etc. of all sizes and shapes at all heights from the existing ground floors and all locations with CM 1:2 under pressure of 2 to 2.8 Kg/cm2 after removing the damaged loose spalled concrete by chipping, removal of dust and applying one coat of rust converter kp-100 equivalent grade over existing exposed old reinforcement wherever necessary providing and tying n position 25x25mm 12mm guage dia wire MS welded mesh or smaller size over treated surface ready to receive grouts including 5mm to 10mm thick plastering in CM 1:4 to match existing surfaces and finished even and smooth including curing for 10 days etc, complete all operations all as specified and directed including labour charges hire for all tools plants and machineries cost of consumable scaffolding, all types of protective equipments, pipelinesand vessels, materials etc. required to do guninting at the site, removing the debries out of the MoD land in low lying areas and levelling as directed, with wo coats of white wash over one coat of primer complete all as specified & directed by Engineer-in-charge. Note:- (a) After placing the additional reinforcement all concrete surfaces should be thoroughly scrubbed with brushes, washed with water and allowed to dry. To this surface apply chemical polycrete admixture at the rate not less than 2% by weight of cement or as per manufacturer instructions. (b) When polymix coating is in tackey condition guniting to be done with polycrete admixture t the rate not less than 2% by weight of cement or as per manufacturer instructions. Polycrete admixture to be procured from Chemical Adhesive Pvt Ltd Co or their authorized dealer. (c) Cost of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothig extra shall be paid on any account.
S&F GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified & directed by Engineer-in-charge.
M&L for 75 mm thick Cement concrete type D - 2,1:4:8 (40 mm graded agg) as in sub base to floors incl well compacting & laid to levels complete all as specified & directed by Engineer-in-charge.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying if inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified & directed by Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified & directed by Engineer-in-charge.
Taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed by Engineer-in-charge.
M&L for 15mm thick rendering in CM 1:6 finished even and smooth without extra cement on stone wall surface complete all as specified & directed by Engineer-in-charge.
M&L for 15 mm thick rendering in CM 1:4 finished surface to be fair and even on stone wall surface, complete all as specified & directed by Engineer-in-charge.
M&L Rendering 10 mm thick CM (1:3) on concrete surfaces on ceiling / facia /RCC Chhaja etc all as directed & finished even & smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
Demolition of stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified & directed by Engineer-in-charge.
M&L PCC solid building blocks 10 cm thick type B1 1:2:4 set in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
M&L for Plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping to parapet walls including necessary form work complete all as specified & directed by Engineer-in-charge.
M&L for Plain cement concrete 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in roof kerbs rounded or chamfered on edges complete all as specified & directed by Engineer-in-charge.
M&L for 5cm thick sand stone slabs in sunshades, chajjas, shelves, cills, landings cover stones templates etc n exc 2m in length punched dressed on face and along exposed edges self faced on other side and set and pointed in cement mortar 1:4 thickness of slab 5cm complete all as specified & directed by Engineer-in-charge.
M&L Udaipur Green marble 16-18mm thick as in window cills,platforms treads of steps etc over and including cement screed 15mm thick in cement mortar 1:4 laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed. Note: Quoted rate deemed to including the cost of chamfering the exposed edges of marble complete all as specified & directed by Engineer-in-charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified & directed by Engineer-in-charge.
M&L for preparing surfaces plastered or unplasterd on new surfaces applying 2 coats of Oil Bound distemper over 1.5mm to 2mm thick wall putty finished to a even and smooth finish over a coat of alkali primer complete all as specifed & directed by Eng-in-charge.
M&L for preparing surfaces plastered or unplasterd on new surfaces with 2 coats of Oil Bound distemper on Ceilings finished to a even and smooth finish complete all as specifed & directed by Eng-in-charge.
M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & directed by Engineer-in-charge.
Taking down chowkhats or frames with shutter exc 1.5 Sqm but not exceeding 4 Sqm each without taking off shutter from the frame complete all as specified & directed by Engineer-in-charge.
Taking down chowkhats with shutters (without taking off shutters from the frames) area nexc 1.50 Sqm & removal to store complete all as specified & directed by Engineer-in-charge.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp?ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified & directed by Engineer-in-charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). → Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified & directed by Engineer-in-charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
Taking down of steel window and ventilators, complete all as specified & directed by Engineer-in-charge.
M&L for fabrication of powder coated aluminium frame work as in frames for aluminium windows, Ventilators & Doors with aluminium section weighing 0.55 kg/m with or without rebate or for sliding windows(two track/three track ) , ventilators etc with louvers having suitable mechanism for tilting , U shaped fillets complete all as specified & directed by Engineer-in-charge.
S&F Anodised aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, 2tower bolts, 1mortice lock of vertical type brass 4 levers size 65mm and anodised aluminium snap beading screws etc, complete all as specified & directed by Engineer-in-charge.
M&L for pre powder coated aluminium decogrill all as per sample fixed to aluminium framework of windows & ventilators complete all as specified & directed by Engineer-in-charge.
M&L for pre powder coated Anodised aluminium Shutters for window and ventilator , side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified & directed by Engineer-in-charge. Note : Glass panes & aluminium wiremesh shall be measured & paid for seperately.
S&F stainless steel wire cloth 0.35 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with aluminium wire staples complete all as specified & directed by Engineer-in-charge.
S&F of 5.5 mm thick plain sheet glass ordinary quality and glazing with aluminum beading in alumium door/window/ventilators not exc. 0.5 Sqm in each pane complete all as specified & directed by Engineer-in-charge.
S&F solar control film 50micron thick non-reflective type sticked to glass panes as per manufacturer's instructions complete all as specified & directed by Engineer-in-charge.
M&L for PVC insulation panel 10mm thick with EPS stuck to 1mm plain PVC sheet suitably placed in aluminium frame work as per specification complete all as specified & directed by Engineer-in-charge.
Taking down Anodised aluminium powder coated doors,window and ventilator frames/ shutters including, replacement of unserviceable hinging devive box type , handles, making them in serviceable condition and re-fixing in same opening including joining cleat for fixing complete all as specified & directed by Engineer-in-charge.
S&F of aluminium anodized,tower bolt 200 mm long complete all as specified & directed by Engineer-in-charge.
S&F of aluminium anodized,tower bolt 150 mm long complete all as specified & directed by Engineer-in-charge.
S&F aluminum anodised handle extruded section of size 150mm long complete all as specified & directed by Engineer-in-charge.
S&F of aluminium alloy anodised sliding door bolt woth hasp and stalpe (bolt type and fixings clips of sheet cast or extruded sections and fixings bolts and sliding bolts of extruded sections and fixed 16mm dia and 300mm long complete all as specified & directed by Engineer-in-charge.
S&F of stainless steel butt hinges 100 mm size medium weight complete all as specified & directed by Engineer-in-charge.
S &F of mild steel butt hinges 100 mm size complete all as specified & directed by Engineer-in-charge.
S&F Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified & directed by Engineer-in-charge.
S & F floor door stopper of alluminium alloy body and toungue anodised with hard drawn steel spring 140mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing in repairs decorative type curtain rod stainless steel finish of pipe 22 to 25 mm dia as per sample approved by GE complete all as specified & directed by Engineer-in-charge.
Supply and fixing of purpose made brackets trade pattern for decorative type curtain rods suitable for holding 22 to 25 mm dia as per sample approved by GE complete all as specified & directed by Engineer-in-charge.
Supply and fixing in repair of decorative fincals (round type with mirror optic finish) trade pattern for decorative type curtain rods suitable for 22 to 25 mm dia curtain rods as per sample approved by GE's complete all as specified & directed by Engineer-in-charge.
Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 110mm bore complete all as specified & directed by Engineer-in-charge.
Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 75mm bore complete all as specified & directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls complete all as specified & directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls complete all as specified & directed by Engineer-in-charge.
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified & directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified & directed by Engineer-in-charge.
S&F 100mm bore pipe PVC (SWR) vent cowls, complete all as specified & directed by Engineer-in-charge.
S&F 75mm bore pipe PVC (SWR) vent cowls, complete all as specified & directed by Engineer-in-charge.
S&F in repairs Grating doom 100mm dia of chromium plated (Minimum weight 25gms) complete all as specified & directed by Engineer-in-charge.
S & F as in repairs 15 mm dia fancy type angular stop cock with chromium plated long thread with flange complete all as specified & directed by Engineer-in-charge.
S&F as in repairs of 15 mm dia fancy type bib taps cast copper alloy long body with flange with chromium plated fixed with iron pipe complete all as specified & directed by Engineer-in-charge.
S&F as in repairs of stop cock cast copper alloy regular body with adujstable wall flange with fancy type chromium plated with (concealed type) 20mm dia for iron pipe etc complete all as complete all as specified & directed by Engineer-in-charge.
S & F in repairs fancy type pillar tap, cast copper alloy, chromium plated, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair 15 mm bore fancy type CP brass two way angular stop cock chromium plated, screwed down high pressure with crutch or butterfly handle scrwed both ends for iorn pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair CP brass health faucet with 1200 mm long flexible tube with wall hook and chromium plated two way angle valve, complete all as specified & directed by Engineer-in-charge.
Dismantling existing tanks of any description n exc 500 ltrs capacity and removing from site complete all as specified & directed by Engineer-in-charge.
S&F 500 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl fixing arrangment for inlet/outlet/overflow & vent pipe of standard size complete all as specified & directed by Engineer-in-charge.
Supply only 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & 3, plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) complete all as specified & directed by Engineer-in-charge. (Fixing included in Item No 78 above)
Supply only Integral water proofing compund complete all as specified & directed by Engineer-in-charge.
Taking down or up steel tubing and connection including cleaning for refixing or credited to contractor for the following bore pipes complete all as specified & directed by Engineer-in-charge.
(a) 25 mm dia
(b) 20 mm dia
(c ) 15 mm dia
S&F of water tubing, medium grade, galvanized, with all fittings fixed to wall or laid in floors complete all as specified & directed by Engineer-in-charge.
(a) 25 mm dia
(b) 20 mm dia
(c ) 15 mm dia including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc
Re fixing/ Re laying of old GI water tubing and connections in new or old position including provision of new GI fittings complete all as specified & directed by Engineer-in-charge.
(a) 25 mm dia
(b) 20 mm dia
(c ) 15 mm dia including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc
M&L Vitrified Ceramic tiles Dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including M&L 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified & directed by Engineer-in-charge.
Demolition of cement concrete (unreinforced) of any description and any position not otherwise specifically provided for (roof padding/roof kerb/sunken floor etc) including tarfelt,plaster etc complete all as specified & directed by Engineer-in-charge.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in padding over old cleaned surface of any description on roof/terrace to fill any depressions etc or to obtain desired slopes complete all as specified & directed by Engineer-in-charge.
M&L for carrying out water proofing treatment for roofs in the following stages - (i) Rendering 15mm thick in cement mortar (1:4), mixed with integral water proofing liquid all as per manufacturer's instructions over concrete surfaces finished even and smooth with out using extra cement.Note : (WPC shell be measured separately and paid for under respective item of schedule). (ii) Material and labour for UV stable single component fibre reinforced elastomeric liquid applied waterproofing membrane having solid content of 55% formulated wih PU hybrid polymers and reinforcing acrylic fibres and having sun reflectivity Index (SRI) of 106. The application of the material should be done in three coat (6 hr gap after each coat) on the substrate, applying first self priming coat at ratio of damp proof ultra and water 3:1 then 2 undiluted coat of damp proof ultra obtaining coverage @1 ltr/10 sqft in two coats (10-12 hrs gap between each coat. The vital physical and chemical parameters shall be as under. Min elongationat break of 350%, crack bridging ability of 2.5 mm @650 microns thickness, resists positive hydrostatic pressure of up to 10 bars. The material shall be appliied with brush or roller, complete in all respect as per the direction of Engr-in charge/consultant. Also, proper surface preparation along with covingat corners is must complete all as specified & directed by Engineer-in-charge. Note : - The work shall be executed by the authorized applicator of the manufacturer only. Note : - 1.The authorized applicator of manufacturer shall be approved by GE. 2.The color of final finish shall be decided by the GE
S&F as in repairs light coloured (Ivory) vitreous china, wash hand basin of size 550mm X 400mm flat back with pedestal Including bracket , CP waste coupling ,chain and plug, 2 Nos PVC connection 15 mm size & 45-60cm long & PVC Waste coupling & flexible waste pipe complete all as specified & directed by Engineer-in-charge.
S & F as in repairs vitreous china wash down water closet European Type pedestal pattern with seat & cover as in repairs with jet spray complete incl fixing of flush pipe etc complete all as specified & directed by Engineer-in-charge.
S & F low level flusing cistern PVC 10 ltrs capacity with float valves (ISI Marked) white with inlet ball valve complete all as specified & directed by Engineer-in-charge.
S & F Vitreous China Urinal, Half stall type,white with Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) including PVC connection , bottle trap 32mm complete all as specified and directed by Engineer-in-charge.
M&L for preparing old surfaces plastered or unplasterd on old surfaces with complete removal of existing treatment applying 2 coats of Oil Bound distemper over 1.5mm to 2mm thick wall putty finished to a even and smooth finish over a coat of alkali primer complete all as specifed & directed by Eng-in-charge.
M&L for preparing old surfaces plastered or unplasterd on old surfaces with complete removal of existing treatment with 2 coats of Oil Bound distemper on Ceilings finished to a even and smooth finish complete all as specifed & directed by Eng-in-charge.
S&F in repair chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union suitable for 15mm bore pipe etc; complete all as specified & directed by Engineer-in-charge.
S&F in repair CP towel rail 600 mm long fixed with and including CP brass screws and wooden/ plastic cleats complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm bore angular stop cock chromium plated, fancy type cast copper alloy, screwed down, high pressure, screwed both ends for iron pipe with long shank and cup complete all as specified & directed by Engineer-in-charge. .
S&F in repair Soap dish, cromium plated , any type, fixed to plugs with chromium plated brass screws complete all as specified & directed by Engineer-in-charge.
S&F 5 - 6 mm thick bevelled edges high quality looking mirror fancy type fixed to wall with chromium plated screw with cup washers etc complete all as specified & directed by Engineer-in-charge.
S&F as in repairs two way angle bib cock cromium plated fancy type 15 mm bore /size Make Johnson or equivalent complete all as specified & directed by Engineer-in-charge.
S&F 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed fixed as in repairs complete all as specified & directed by Engineer-in-charge.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified & directed by Engineer-in-charge.
S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified & directed by Engineer-in-charge.
M&L Vitrified Ceramic tiles Dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm , in vertical surfaces dado/skirting joint free etc, set and jointed in neat cement slurry and pointed in coloured tiles to match the shade of tiles over 10 mm thick rendering in CM1:4 over stone masonry surfaces & finished even & rough to receive tile complete all as specified & directed by Engineer-in-charge.
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified & directed by Engineer-in-charge.
Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site complete all as specified & directed by Engineer-in-charge.
Taking down carefully UNSV submain wiring of any size complete all as specified & directed by Engineer-in-charge.
M&L for Point wiring (Concealed) using approved colour coding as per IS Red/Yellow/Blue, Black and green for single phase circuits) with multi stranded copper conductor 1.5 Sqmm nominal cross area single core PVC insulated and unsheathed FR LS cable 1100 Volts grade ISI 694 marked with valid CML No. in and including medium grade PVC concealed conduit of dia not less than 20mm and conduit accessories ISI marked with valid CML No. ( IS 9537 -1983 for wall/roof /floor etc with pressed flush metal boxes covered with inner plates & outer plates etc suitable for mounting of Modular switches & sockets including PVC insulated multi stranded copper conductor FRLS 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continully conductor to commonearth and connecting to earrth dolly complete all as specified & directed by Engineer-in-charge for the follwing
One light/Fan /Bell point controlled by one, one way switch complete all as specified & directed by Engineer-in-charge.
One socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch complete all as specified & directed by Engineer-in-charge.
One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch complete all as specified & directed by Engineer-in-charge.
All as per srl item No. 107 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point complete all as specified & directed by Engineer-in-charge.
All as per srl item No. 107 here-in-before but with 4 sq mm FRLS copper wire with 4 Sqmm FRLS copper earth wire for indpendent 15 Amp point complete all as specified & directed by Engineer-in-charge.
S&F Modular switch flush type single pole one way 6 Amp ISI Marked complete all as specified & directed by Engineer-in-charge.
S&F Modular switch flush type single pole one way 16 Amp ISI Marked complete all as specified & directed by Engineer-in-charge.
Supply and fix remote bell, AC 230 volts, single pole complete all as specified & directed by Engineer-in-charge.
S&F Modular socket outlet 2 in 1, 5 pin, 6 Amp, 230 Volts flush type, ISI Marked complete all as specified & directed by Engineer-in-charge.
S&F Modular socket outlet 2 in 1, 6 pin, 5 and 16 amp flush type, 230 Volts ISI Marked complete all as specified & directed by Engineer-in-charge.
Supply and fix modular socketed(2 Module) stepped type electonic fan regulator flush type ISI Marked complete all as specified & directed by Engineer-in-charge.
S&F Ceiling rose, three terminals, bakelite body, 230 volts, complete all as specified & directed by Engineer-in-charge.
Supply and fixing replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including AC decorative box type with driver, holder including,copper conductor cable of suitable size from ceiling rose complete complete, 4 ft long complete all as specified & directed by Engineer-in-charge.
S&F in replacement bldg security LED Light Luminaire of 35 Watts having IP 65 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with and including GI pipe 40 mm bracket of 1.5 m in length including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable complete all as specified & directed by Engineer-in-charge.
Supply and fixing replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed by Engineer-in-charge.
Supply and fix in repair 2'x2' energy efficient recess mounting 36 watt LED lumanaries fixing for POP/snapgrid ceiling housing including LED lamps other accessories and necessary electric connection complete all as specified & directed by Engineer-in-charge.
S&F in replacement Decorative, wall mounting fitting brushed nickel finish fixture with acrylic diffuser suitable with 9 W LED lamp B22 base complete all as specified & directed by Engineer-in-charge.
Taking down and refixing / Hanging only ceiling fan (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified & directed by Engineer-in-charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified & directed by Engineer-in-charge.
Taking down and re-fixing only exhaust fan (M.D.supply) and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified & directed by Engineer-in-charge.
S&F Vertical Distribution Board, double Door, suitable for 'A' Frame FP MCCB 100A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 4 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, complete all as specified & directed by Engineer-in-charge. Note : MCCB & MCB will be measured and paid separately under respective items
S&F MCCB, 'A' Frame, thermal adjustable magnectic setting, Ics = 75% 25 kA, 415V, 100 Amp, 4 Pole MCCB with over load and short circuit protection, complete all as specified & directed by Engineer-in-charge.
S&F MCB, B Curve type, 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as specified & directed by Engineer-in-charge.
S&F MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as specified & directed by Engineer-in-charge.
S&F sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 10 MCB SP as out going SPN 12 way complete all as specified and directed by Engr-in-charge.
M&L for sub main wiring with 2 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 25 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as specified & directed by Engineer-in-charge. Note:- Two run of 6 Sq.mm. and one run of 6 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
M&L for sub main wiring with 2 run of 4 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 25 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as specified & directed by Engineer-in-charge. Note:- Two run of 4 Sq.mm. and one run of 4 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
M&L for in repairs earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 mm dia with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified & directed by Engineer-in-charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
M&L for in repairs earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI Strip earth lead of Size25x 4 mma by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 mm dia with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 32mm bore medium grade GI protection pipe, test point etc. complete all as specified & directed by Engineer-in-charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI Strp 25 x 4 sqmm as earth lead.
Supply, laying testing LT UG XLPE in trenches/saddle clamping on wall (as per site requirement insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area 50 sqmm 3.5 core complete all as specified & directed by Engineer-in-charge. Note : Earth work and brick work measured and paid separately
Supply, laying testing LT UG XLPE in trenches/saddle clamping on wall (as per site requirement insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area 95 sqmm 3.5 core complete all as specified & directed by Engineer-in-charge. Note : Earth work and brick work measured and paid separately
Excvation in trenches not more than 1.5 meter wide and in depth in hard/dense/loose soil complete all as specified & directed by Engineer-in-charge.
Retuerning and filling of excvated hard/dense/loose soil in treches complete all as specified & directed by Engineer-in-charge.
Removal of surplus hard/dense/loose soil from excavated place and deposting at safe side distance not more than 50 meter from excavated place complete all as specified & directed by Engineer-in-charge.
Supply and lay sand for sand cushioning for cable protection in trenches complete all as specified & directed by Engineer-in-charge in SSR Part - 1.Note:. for the purpose of payment punned thickness will be measured.
Supply and laying Un reinforced Precast concrete cable cover, flat size 300 mm x 180 mm x 40mm complete all as specified & directed by Engineer-in-charge.
Supply and fix GI tubing Light grade of 40 mm dia for cable protection complete all as specified & directed by Engineer-in-charge.
Supply and fixing of sheet metal enclosure SPN with a two pin earth plug and socket with metal cladd top and one MCB,SP 20amps capacity complete all as specified & directed by Engineer-in-charge.
Taking down old serviceable Spilt AC complete (inner and outer) incl voltage stablizer any size and capacity , plug the gas pipe safly, and take in safe custudy servicing and and refix in same position complete all as specified & directed by Engineer-in-charge.
Taking down old serviceable Window AC complete incl voltage stablizer any size and capacity and take in safe custudy and refix in same position complete all as specified & directed by Engineer-in-charge.
M & L for road cutting(not more than 3.5 mtr in width of road) and excavation upto 60 cm below ground level and laying of 5 running mtr protection 40 mm dia GI pipe of Light grade and make good distrubuted suface by PCC 1:4:8 (nominal mix), type D-2, using 40mm graded crushed stone aggregate complete all as specified & directed by Engineer-in-charge.
S & F Brass swing ceiling fan fastener Hook , 12 mm size complete all as specified & directed by Engineer-in-charge.
MCCB 160 Amp 16 kA, (01 No) (Incomming)
MCCB 100 amp, 16 kA(03 Nos) (Outgoing)
MCB TPN 63 Amps(02)
Amp meter - 01 No
Voltmeter - 01 No
S & F indiaction Lamp tower lamp type incl taking down old unserviceable complete all as specified & directed by Engineer-in-charge.
M/L in repairs sub main wiring with FRLS PVC insulated and unsheathed 1.5 Sq mm single core multistrandred copper conductor cable passing through in and including PVC conduit , concealing in walls ( by means of chasing including making good existing surface and matching existing surface ) ISI marked and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, incl 1.5 Sq mm single core FRLS copper conductor cable PVC insulated and unsheathed as earth wire complete all as specified & directed by Engineer-in-charge. Note :- Two runs of cable 1.5 Sqmm and One run of 1.5 Sqmm along with conduit shall be measured as one unit length.
M/s Vishnu Infrastructures (BID ID -3299948)
SNEH CORPORATION (BID ID -3305493)
D.K.CONSTRUCTION CO (BID ID -3300443)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .