NAME OF WORK:-CONSTRUCTION OF SP & ABOVE RESIDENT CAT-E1-20 (P+11) AT BODAKDEV , AHEMEDABAD(INCLUDING ELECTRICAL WORK)
Statement showing the approximate quantities for the items of the above work to be carried out and approximate cost put to tender for Rs.
SCHEDULE -B WITH RATE
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Demolition of brick work & stone masonary incl. stacking of servicable material and disposal of
unservicable material with disposing all lead and lift. (iii)In cement mortar Rupees Five Hundred Forty Four
And Paise Ninety Five Only
Demolition including stacking of serviceable materials and disposal of unserviceable material with all
lead and lift (i)R.C.C. work Rupees One Thousand Forty
Seven And Paise Thirty Eight Only
Excavation for foundation in loose or soft soil upto 1.5 m. depth including sorting out and stacking of
useful materials and disposing of the excavated stuff upto any Lead and lift. Rupees One Hundred Fifteen And
Paise Ninety Two Only
Excavation for foundation indense or hard soil 1.5 m. to 3.0 m depth including sorting out and stacking
of useful materials and disposing of the excavated stuff upto any Lead and lift. Rupees One Hundred Sixty And
Paise Seventy Seven Only
Excavation for foundation indense or hard soil 3.0 m. to 5.0 m depth including sorting out and stacking
of useful materials and disposing of the excavated stuff upto any Lead and lift. Rupees One Hundred Seventy Two
And Paise Fifty Only
Excavation for foundation indense or hard soil MORE THAN 5.0 m depth including sorting out and
stacking of useful materials and disposing of the excavated stuff upto any Lead and lift. Rupees One Hundred Ninety Three
And Paise Forty One Only
Filling avaliable excavate earth ( excluding rock). In trenches, plinth sides of foundations etc. in layers
NOt exceeding 20 cms. In depth consolidation each deposited layer by ramming and watering. Rupees One Hundred Twenty Nine
And Paise Ten Only
Filling In Foundation & Plinth With Murrum Or Selected Soil In Layers Of 20Cms Th. Inclu.. Watering
, Ramming & Consolidating Etc.. Complete Rupees Two Hundred Eighty Six
And Paise Twenty Only
Applying general insecticide pest control treatment to floors, cupboards etc including labour material
etc. complete. Using Imidacloprid 30.5 SCas
Rupees Eighty Eight And Paise
9 as Per 6313part -II (0.075 % concentration by mass) is recommended 10.5 ml chemical diluted with 5 723.00 SMT 88.40
litres of water application 0.5 litre chemical/Sqm if surface is recommended as per I.S.
FILLING in plinth with SAND under floors including watering, raming consolidating and dressing etc.
complete. Rupees Four Hundred Fifty Five
And Paise Sixty Three Only
Providing and laying in position Ready Mixed M-150 grade concrete for reinforced cement conctere
work, using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer For up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Three Thousand Seven
plywood only with fair finish & proping must be of steel only so as to give a fair finish.) Providing & Mixing
11 1.00 CMT 3790.21 Hundred Ninety And Paise Twenty
admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer -in-charge.
Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS 456 shall be
maintained) in Foundation and Mass Concrete.(FOR GRID SLAB )
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-200 grade concrete for reinforced cement conctere
work, using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer For up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Four Thousand Seven
plywood only with fair finish and proping must be of steel only as to give a fair finish Providing & Mixing
12 116.00 CMT 4793.10 Hundred Ninety Three And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer -in-charge.
Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS 456 shall be
maintained) in Foundation and Mass Concrete.(FOR GRID SLAB )
Providing and laying in position Ready Mixed M-200 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including providing formwork with Rupees Six Thousand One
13 sheating steel sheets and the cost of centering shuttering, Providing & Mixing admixtures in 11.00 CMT 6179.53 Hundred Seventy Nine And Paise
recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability Fifty Three Only
without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash
But Excluding Cost Of Reinforcement (Min cement level as per latest IS 456 shall be maintained) in
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including providing formwork with Rupees Six Thousand Two
14 sheating steel sheets and the cost of centering shuttering, Providing & Mixing admixtures in 26.00 CMT 6239.99 Hundred Thirty Nine And Paise
recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability Ninety Nine Only
without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash
But Excluding Cost Of Reinforcement (Min cement level as per latest IS 456 shall be maintained) in
Providing & laying plain cement CONCRETE 1:2:4 (1-cement : 2-coarse sand : 4-graded STONE Rupees Three Thousand Six
15 AGGREGATE 20 mm NOminal size) and curing etc. complete excluding cost of formwork in 5.00 CMT 3661.30 Hundred Sixty One And Paise
FOUNDATION & PLINTH. Thirty Only
Providing and laying cement concrete 1:3:6(1- cement : 3- coarse sand : 6- hand broken stone
Rupees Two Thousand Nine
16 aggregates 20 mm. nominal size) and curing complete excluding cost of from work in : (a) Foundation 228.00 CMT 2976.00
Hundred Seventy Six Only
Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8- hand broken stone Rupees Two Thousand Six
17 aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and 91.00 CMT 2653.67 Hundred Fifty Three And Paise
Plinth Sixty Seven Only
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere
work, using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including providing formwork with Rupees Five Thousand Three
18 sheating steel sheets and the cost of centering, shuttering. Providing & Mixing admixtures in
29.00 CMT 5337.29 Hundred Thirty Seven And Paise
recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, improve workability
Twenty Nine Only
without impairing strength and durability as per direction of the Engineer -in-charge. Without Fly Ash But
Excluding Cost Of Reinforcement (Min cement level as per latest IS 456 shall be maintained) in
Foundation FOOTING and Mass Concrete.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work, using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer For up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of Rupees Five Thousand One
19 plywood only with fair finish and proping must be of steel only as to give a fair finish Providing & Mixing 796.00 CMT 5147.19 Hundred Forty Seven And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer -in-charge.
Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS 456 shall be
maintained) in Foundation FOOTING and Mass Concrete.
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including providing formwork with Rupees Ten Thousand Seven
20 sheating steel sheets and the cost of centering shuttering, Providing & Mixing admixtures in 7.00 CMT 10785.98 Hundred Eighty Five And Paise
recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability
Ninety Eight Only
without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash
But Excluding Cost Of Reinforcement (Min cement level as per latest IS 456 shall be maintained) in
Column having any cross sectional area of Columns.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Two
plywood only with fair finish and proping must be of steel only as to give a fair finish Providing & Mixing
21 16.00 CMT 9205.78 Hundred Five And Paise Seventy
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in Column having any cross sectional area of Columns. FOR COLUMN UPTO
Providing and laying in position Ready Mixed M-200 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including providing formwork with Rupees Ten Thousand Five
22 sheating steel sheets and the cost of centering shuttering, Providing & Mixing admixtures in 14.00 CMT 10535.42 Hundred Thirty Five And Paise
recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability Forty Two Only
without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash
But Excluding Cost Of Reinforcement (Min cement level as per latest IS 456 shall be maintained) in
Column having any cross sectional area of Columns FOR GROUND FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including providing formwork with
Rupees Ten Thousand Five
(formwork of plywood only with fair finish & proping must be of steel only so as to give a fair finish.) .,
23 9.00 CMT 10595.88 Hundred Ninety Five And Paise
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
Eighty Eight Only
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in COLUMN having any cross sectional area of Columns. FOR GROUND
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Seven Thousand Nine
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
24 159.00 CMt 7964.53 Hundred Sixty Four And Paise Fifty
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL UP TO
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Seven Thousand Nine
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
25 86.00 CMT 7964.53 Hundred Sixty Four And Paise Fifty
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing Rupees Eight Thousand Four And
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Paise Thirty Eight Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR FIRST
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing Rupees Eight Thousand Forty Four
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, And Paise Twenty Three Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing Rupees Eight Thousand Eighty
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Four And Paise Eight Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR THIRD
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Eight Thousand One
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
29 86.00 CMT 8123.93 Hundred Twenty Three And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Ninety Three Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Eight Thousand One
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
30 86.00 CMT 8163.78 Hundred Sixty Three And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Seventy Eight Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR FIFTH
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Eight Thousand Two
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
31 86.00 CMT 8203.63 Hundred Three And Paise Sixty
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR SIXTH
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Eight Thousand Two
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
32 86.00 CMT 8243.48 Hundred Forty Three And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Forty Eight Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Eight Thousand Two
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
33 86.00 CMT 8283.33 Hundred Eighty Three And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Thirty Three Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Eight Thousand Three
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
34 86.00 CMT 8323.18 Hundred Twenty Three And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR
Providing and laying in position Ready MixedM-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Eight Thousand Three
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
35 86.00 CMT 8363.03 Hundred Sixty Three And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR TENTH
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Eight Thousand Four
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
36 86.00 CMT 8402.88 Hundred Two And Paise Eighty
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR
ELEVENTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Eight Thousand Four
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
37 36.00 CMT 8442.73 Hundred Forty Two And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Seventy Three Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR
TWELVETH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Eight Thousand Four
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
38 6.00 CMT 8482.58 Hundred Eighty Two And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Fifty Eight Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SHEAR WALL having any cross sectional area of SHEAR WALL . FOR
THIRTEENTH FLOOR.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Seven Thousand Three
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
39 86.00 CMT 7341.98 Hundred Forty One And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Ninety Eight Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) for PLINTH BEAM for any cross sectional area of beam
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement
Rupees Nine Thousand Forty Eight
40 concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the 59.00 CMT 9048.81
And Paise Eighty One Only
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish .
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR GROUND FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement
Rupees Nine Thousand Eighty
41 concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the 49.00 CMT 9088.66
Eight And Paise Sixty Six Only
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish .
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR FIRST FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement Rupees Nine Thousand One
42 concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the 50.00 CMT 9128.51 Hundred Twenty Eight And Paise
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish . Fifty One Only
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR SECOND FLOOR.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement Rupees Nine Thousand One
43 concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the 50.00 CMT 9168.36 Hundred Sixty Eight And Paise
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish . Thirty Six Only
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR THIRD FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement Rupees Nine Thousand Two
44 concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the 50.00 CMT 9208.21 Hundred Eight And Paise Twenty
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish . One Only
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR FOURTHFLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement Rupees Nine Thousand Two
45 concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the 50.00 CMT 9248.06 Hundred Forty Eight And Paise Six
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish . Only
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR FIFTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement Rupees Nine Thousand Two
46 concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the 50.00 CMT 9287.91 Hundred Eighty Seven And Paise
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish . Ninety One Only
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FORSIXTH FLOOR.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement Rupees Nine Thousand Three
47 concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the 50.00 CMT 9327.76 Hundred Twenty Seven And Paise
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish . Seventy Six Only
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR SEVENTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement Rupees Nine Thousand Three
48 concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the 50.00 CMT 9367.61 Hundred Sixty Seven And Paise
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish . Sixty One Only
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR EIGHTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement Rupees Nine Thousand Four
49 concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the 50.00 CMT 9407.46 Hundred Seven And Paise Forty
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish . Six Only
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR NINETH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement Rupees Nine Thousand Four
50 concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the 50.00 CMT 9447.31 Hundred Forty Seven And Paise
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish . Thirty One Only
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR TENTH FLOOR.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement
Rupees Nine Thousand Four
concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the
51 51.00 CMT 9487.16 Hundred Eighty Seven And Paise
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish .
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting Sixteen Only
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR ELEVENTH FLOOR.
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement
Rupees Nine Thousand Seven
concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the
52 11.00 CMT 9717.11 Hundred Seventeen And Paise
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish .
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting Eleven Only
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR TWELVETH FLOOR.
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement Rupees Nine Thousand Seven
53 concrete work including pumping of R.M.C. from transit mixer to site of laying & finishing, including the 7.00 CMT 9756.96 Hundred Fifty Six And Paise Ninety
cost of formwork of plywood only with fair finish and proping must be of steel only as to give a fair finish . Six Only
Providing & Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting
of concrete, improve workability without impairing strength and durability as per direction of the Engineer
- in - charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
456 shall be maintained) in Beam having any cross section area of BEAM. FOR THIRTEENTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Two
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
54 91.00 CMT 9246.51 Hundred Forty Six And Paise Fifty
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm. FOR GROUND FLOOR.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Two
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
55 69.00 CMT 9286.36 Hundred Eighty Six And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Thirty Six Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm. FOR FIRST FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Three
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
56 69.00 CMT 9326.21 Hundred Twenty Six And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Twenty One Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm. FOR SECOND FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Three
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
57 69.00 CMT 9366.06 Hundred Sixty Six And Paise Six
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm FOR THIRD FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Four
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
58 69.00 CMT 9405.91 Hundred Five And Paise Ninety
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm FOR FOURTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Four
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
59 69.00 CMT 9445.76 Hundred Forty Five And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Seventy Six Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm FOR FIFTH FLOOR.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Four
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
60 69.00 CMT 9485.61 Hundred Eighty Five And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm FOR SIXTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Five
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
61 69.00 CMT 9525.46 Hundred Twenty Five And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm. FOR SEVENTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing Rupees Nine Thousand Five
62 admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, 69.00 CMT 9565.31 Hundred Sixty Five And Paise
improve workability without impairing strength and durability as per direction of the Engineer - in - Thirty One Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm FOR EIGHTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Six
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
63 69.00 CMT 9605.16 Hundred Five And Paise Sixteen
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm FOR NINTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Six
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
64 69.00 CMT 9645.01 Hundred Forty Five And Paise One
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm. FOR TENTH FLOOR.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Six
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
65 69.00 CMT 9684.86 Hundred Eighty Four And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Eighty Six Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm FOR ELEVENTH FLOOR.
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, including the cost of formwork of
Rupees Nine Thousand Nine
plywood only with fair finish and proping must be of steel only as to give a fair finish . Providing & Mixing
66 6.00 CMT 9914.81 Hundred Fourteen And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Eighty One Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in SLAB having thickness of 10cm upto 13cm. FOR TWELVETH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including providing formwork with
Rupees Eight Thousand Seven
sheating steel sheets and the cost of centering shuttering, Providing & Mixing admixtures in
67 11.00 Cum 8709.21 Hundred Nine And Paise Twenty
recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability
without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash
But Excluding Cost Of Reinforcement (Min cement level as per latest IS 456 shall be maintained) in
SLAB having thickness of 13cm upto 15cm for GROUND FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Two
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
68 18.00 CMT 8273.05 Hundred Seventy Three And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR GROUND FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Three
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
69 26.00 CMT 8312.90 Hundred Twelve And Paise Ninety
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR FIRST FLOOR.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Three
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
70 26.00 CMT 8352.75 Hundred Fifty Two And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Seventy Five Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR SECOND FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Three
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
71 26.00 CMT 8392.60 Hundred Ninety Two And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR THIRD FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Four
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
72 26.00 CMT 8432.45 Hundred Thirty Two And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
Forty Five Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR FOURTH
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Four
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
73 26.00 CMT 8472.30 Hundred Seventy Two And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR FIFTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Five
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
74 26.00 CMT 8512.15 Hundred Twelve And Paise Fifteen
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR SIXTH FLOOR.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing Rupees Eight Thousand Five
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Hundred Fifty Two Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR SEVENTH
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Five
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
76 26.00 CMT 8591.85 Hundred Ninety One And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Eighty Five Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR EIGHTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Six
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
77 26.00 CMT 8631.70 Hundred Thirty One And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Seventy Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR NINTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Six
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
78 26.00 CMT 8671.55 Hundred Seventy One And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Fifty Five Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR TEN FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Seven
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
79 26.00 CMT 8711.40 Hundred Eleven And Paise Forty
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR ELEVENTH
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Nine
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
80 24.00 CMT 8941.35 Hundred Forty One And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Thirty Five Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR TWELVETH
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Nine
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
81 11.00 CMT 8981.20 Hundred Eighty One And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Twenty Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 16cm upto 18cm. FOR THIRTEENTH
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing Rupees Eight Thousand Fifty Eight
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, And Paise Eighty Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 18cm upto 20cm. FOR GROUND
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing Rupees Eight Thousand Ninety
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Eight And Paise Sixty Five Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 18cm upto 20cm. FOR FIRST FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand One
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
84 5.00 CMT 8138.50 Hundred Thirty Eight And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Fifty Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 18cm upto 20cm. FOR SECOND
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand One
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
85 5.00 CMT 8178.35 Hundred Seventy Eight And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Thirty Five Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 18cm upto 20cm. FOR THIRD FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Two
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
86 5.00 CMT 8218.20 Hundred Eighteen And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Twenty Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of18cm upto 20cm. FOR FOURTH
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Two
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
87 5.00 CMT 8258.05 Hundred Fifty Eight And Paise Five
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 18cm upto 20cm. FOR FIFTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Two
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
88 5.00 CMT 8297.90 Hundred Ninety Seven And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Ninety Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 18cm upto 20cm. FOR SIXTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Three
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
89 5.00 CMT 8337.75 Hundred Thirty Seven And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Seventy Five Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 18cm upto 20cm. FOR SEVENTH
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Three
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
90 5.00 CMT 8377.60 Hundred Seventy Seven And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Sixty Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 18cm upto 20cm. FOR EIGHTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Four
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
91 5.00 CMT 8417.45 Hundred Seventeen And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Forty Five Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 18cm upto 20cm. FOR NINTH FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Four
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
92 5.00 CMT 8457.30 Hundred Fifty Seven And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Thirty Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 18cm upto 20cm. FOR TEN FLOOR.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Eight Thousand Four
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Mixing
93 5.00 CMT 8497.15 Hundred Ninety Seven And Paise
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in - Fifteen Only
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in LANDING SLAB having thickness of 18cm upto 20cm. FOR ELEVENTH
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of Rupees Eight Thousand Seven
94 plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & 6.00 CMT 8774.09 Hundred Seventy Four And Paise
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Nine Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR GROUND FLOOR
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of Rupees Eight Thousand Eight
95 plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & 2.00 CMT 8813.94 Hundred Thirteen And Paise Ninety
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Four Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR FIRST FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of Rupees Eight Thousand Eight
96 plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & 3.00 CMT 8853.79 Hundred Fifty Three And Paise
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Seventy Nine Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR SECOND FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of Rupees Eight Thousand Eight
97 plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & 3.00 CMT 8893.64 Hundred Ninety Three And Paise
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Sixty Four Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR THIRD FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of Rupees Eight Thousand Nine
98 plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & 3.00 CMT 8933.49 Hundred Thirty Three And Paise
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Forty Nine Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR FOURTH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of Rupees Eight Thousand Nine
99 plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & 3.00 CMT 8973.34 Hundred Seventy Three And Paise
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Thirty Four Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR FIFTH FLOOR
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Rupees Nine Thousand Thirteen
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, And Paise Nineteen Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR SIXTH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Rupees Nine Thousand Fifty Three
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, And Paise Four Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR SEVENTH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & Rupees Nine Thousand Ninety Two
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, And Paise Eighty Nine Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR EIGHTH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of Rupees Nine Thousand One
103 plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & 3.00 CMT 9132.74 Hundred Thirty Two And Paise
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Seventy Four Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR NINTH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of Rupees Nine Thousand One
104 plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & 3.00 CMT 9172.59 Hundred Seventy Two And Paise
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Fifty Nine Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR TENTH FLOOR
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of Rupees Nine Thousand Two
105 plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & 3.00 CMT 9212.44 Hundred Twelve And Paise Forty
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Four Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR ELEVENTH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of Rupees Nine Thousand Two
106 plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & 1.00 CMT 9252.29 Hundred Fifty Two And Paise
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Twenty Nine Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintels. FOR TWELVETH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Two
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
107 4.00 CMT 6239.99 Hundred Thirty Nine And Paise
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Ninety Nine Only
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR GROUND FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Two
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
108 9.00 CMT 6279.84 Hundred Seventy Nine And Paise
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Eighty Four Only
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR FIRST FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Three
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
109 13.00 CMT 6319.69 Hundred Nineteen And Paise Sixty
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR SECOND FLOOR
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Three
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
110 13.00 CMT 6359.54 Hundred Fifty Nine And Paise Fifty
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR THIRD FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Three
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
111 13.00 CMT 6399.39 Hundred Ninety Nine And Paise
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Thirty Nine Only
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR FOURTH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Four
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
112 13.00 CMT 6439.24 Hundred Thirty Nine And Paise
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Twenty Four Only
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR FIFTH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Four
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
113 13.00 CMT 6479.09 Hundred Seventy Nine And Paise
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR SIXTH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Five
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
114 13.00 CMT 6518.94 Hundred Eighteen And Paise
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Ninety Four Only
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR SEVENTH FLOOR
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Five
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
115 13.00 CMT 6558.79 Hundred Fifty Eight And Paise
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Seventy Nine Only
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR EIGHT FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Five
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
116 13.00 CMT 6598.64 Hundred Ninety Eight And Paise
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Sixty Four Only
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR NINETH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Six Hundred
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
117 13.00 CMT 6638.49 Thirty Eight And Paise Forty Nine
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR TENTH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Six Hundred
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
118 13.00 CMT 6678.34 Seventy Eight And Paise Thirty
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR ELEVENTH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Seven
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
119 3.00 CMT 6718.19 Hundred Eighteen And Paise
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR TWELVE FLOOR
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
Rupees Six Thousand Seven
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
120 2.00 CMT 6758.04 Hundred Fifty Eight And Paise
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in R.C.C. Lintel Bend. FOR THIRTEENTH FLOOR
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
Rupees Nine Thousand Eight
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
121 89.00 CMT 9845.15 Hundred Forty Five And Paise
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) M-250 for reinforced conerete CHHAJJAS for any thickness including finishing the
exposed surface with cement mortar 1:3 ( 1 cement : 3 fine sand) to give a smooth surface FOR ALL
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of Rupees Seven Thousand Three
122 plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing & 120.00 CMT 7357.19 Hundred Fifty Seven And Paise
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, Nineteen Only
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in STAIRCASE FOR All Floors.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere
work , using cement content as per approved Design Mix manufactured in fully automatic batching plant
and transported to site of work in transit mixer for up to any lead having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including the cost of with (formwork of
Rupees Fifteen Thousand Three
plywood only with fair finish & proping must be of steel only so as to give a fair finish). Providing &
123 34.00 CMT 15303.66 Hundred Three And Paise Sixty Six
Mixing admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength and durability as per direction of the Engineer - in -
charge. Without Fly Ash But Excluding Cost Of Reinforcement (Min cement level as per latest IS
shall be maintained) in VERTICAL AND HORIZONTAL FINS / PADADI FOR TERRACE FLOOR
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work
, using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying & finishing, Including providing formwork with
sheating steel sheets and the cost of centering shuttering, Providing & Mixing admixtures in Rupees Eight Thousand One
124 recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability 26.00 CMT 8146.91 Hundred Forty Six And Paise
without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash Ninety One Only
But Excluding Cost Of Reinforcement (Min cement level as per latest IS 456 shall be maintained) in
VARTICAL & HORIZONTAL FINS / PADADI for G.F. (One Side Shuttering for Sump Wall)
Providing T.M.T, FE - 500D Bar Reinfor Cement for R.C.C.work including cutting, bending, binding and
placing in position etc.complete for All Floors. (Brand as approved by GSPHC) Rupees Eighty And Paise Sixty
BRICK work masonary in common brunt clay building bricks having crusing strength NOt less than 35 Rupees Three Thousand Nine
126 kg./sq.cm.in cement mortar 1:6 (1 cement : 6 coarse sand ) (conventional bricks FOR FOUNDATION& 92.00 CMT 3981.21 Hundred Eighty One And Paise
PLINTH Twenty One Only
BRICK work masonary in common brunt clay building bricks having crusing strength NOt less than 35 Rupees Four Thousand Two
127 kg./sq.cm.in cement mortar 1:6 (1 cement : 6 coarse sand ) (conventional bricks FOR GROUND 18.00 CMT 4253.46 Hundred Fifty Three And Paise
FLOOR Forty Six Only
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and Rupees Five Thousand Nine
128 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 43.00 CMT 5990.42 Hundred Ninety And Paise Forty
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to Two Only
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR GROUND FLOOR
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and
Rupees Six Thousand Thirty And
129 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 92.00 CMT 6030.21
Paise Twenty One Only
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR FIRST FLOOR
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and
Rupees Six Thousand Seventy
130 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 111.00 CMT 6070.00
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR SECOND FLOOR
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and Rupees Six Thousand One
131 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 111.00 CMT 6109.79 Hundred Nine And Paise Seventy
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to Nine Only
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR THIRD FLOOR
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and Rupees Six Thousand One
132 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 111.00 CMT 6149.58 Hundred Forty Nine And Paise
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to Fifty Eight Only
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR FOURTH FLOOR
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and Rupees Six Thousand One
133 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 111.00 CMT 6189.37 Hundred Eighty Nine And Paise
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to Thirty Seven Only
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR FIFTH FLOOR
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and Rupees Six Thousand Two
134 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 111.00 CMT 6229.16 Hundred Twenty Nine And Paise
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to Sixteen Only
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR SIXTH FLOOR
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and Rupees Six Thousand Two
135 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 111.00 CMT 6268.95 Hundred Sixty Eight And Paise
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to Ninety Five Only
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR SEVENTH FLOOR
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and Rupees Six Thousand Three
136 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 111.00 CMT 6308.74 Hundred Eight And Paise Seventy
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to Four Only
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR EIGHTH FLOOR
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and Rupees Six Thousand Three
137 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 111.00 CMT 6348.53 Hundred Forty Eight And Paise
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to Fifty Three Only
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR NINTH FLOOR
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and Rupees Six Thousand Three
138 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 111.00 CMT 6388.32 Hundred Eighty Eight And Paise
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to Thirty Two Only
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR TENTH FLOOR
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and Rupees Six Thousand Four
139 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 111.00 CMT 6428.11 Hundred Twenty Eight And Paise
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to Eleven Only
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR ELEVENTH FLOOR
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and Rupees Six Thousand Four
140 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 39.00 CMT 6467.90 Hundred Sixty Seven And Paise
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to Ninety Only
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR TWELVETH FLOOR
Providing and Laying Autoclaved Aerated Fly sand based cement concrete (AAC) masonry blocks
confirming to IS 2185 (Part 3) having compressive strength not less than 4.0 N/mm2 (heavy strength)
and jointed with block jointing adhesive mortar having tensile strength of not less than 0.8 N/mm2 and Rupees Six Thousand Five
141 ensuring long lasting thermal insulation according to European norms (EN13501-2) suitable for high 15.00 CMT 6507.69 Hundred Seven And Paise Sixty
performance of external & internal concrete masonry walls, joint having thickness in thin layer of 3 mm to Nine Only
4 mm between masonry units. Masonry blocks need not to pre-wetthe blocks or post cure the wall with
water. FOR THIRTEENTH FLOOR
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees One Hundred Ninety Nine
142 finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including finishing with floating coat of neat 887.00 SMT 199.88
And Paise Eighty Eight Only
cement at Ground Floor.
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees Two Hundred Twenty Five
143 finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including finishing with floating coat of neat 802.00 SMT 225.69
And Paise Sixty Nine Only
cement at FIRST Floor.
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees Two Hundred Fifty One
144 finished even and smooth in C.M. 1:3 ( 1 cement : 3 coarse sand ) including finishing with floating coat of 716.00 SMT 251.50
And Paise Fifty Only
neat cement at SECOND Floor.
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees Two Hundred Seventy
145 finished even and smooth in C.M. 1:3 ( 1 cement : 3 coarse sand ) including finishing with floating coat of 716.00 SMT 277.31
Seven And Paise Thirty One Only
neat cement at THIRD Floor.
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees Three Hundred Three And
146 finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including finishing with floating coat of neat 716.00 SMT 303.12
Paise Twelve Only
cement at FOURTH Floor.
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees Three Hundred Twenty
147 finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including finishing with floating coat of neat 716.00 SMT 328.93
Eight And Paise Ninety Three Only
cement at FIFTH Floor.
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees Three Hundred Fifty Four
148 finished even and smooth in C.M. 1:3 ( 1 cement :3 coarse sand ) including finishing with floating coat of 716.00 SMT 354.74
And Paise Seventy Four Only
neat cement at SIXTH Floor.
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees Three Hundred Eighty And
149 finished even and smooth in C.M. 1:3 ( 1 cement : 3 coarse sand ) including finishing with floating coat of 716.00 SMT 380.55
Paise Fifty Five Only
neat cement at SEVEN Floor.
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees Four Hundred Six And
150 finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including finishing with floating coat of neat 716.00 SMT 406.36
Paise Thirty Six Only
cement at EIGHTH Floor.
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees Four Hundred Thirty Two
151 finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including finishing with floating coat of neat 716.00 SMT 432.17
And Paise Seventeen Only
cement at NINE Floor.
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees Four Hundred Fifty Seven
152 finished even and smooth in C.M. 1:3 ( 1 cement :3 coarse sand ) including finishing with floating coat of 716.00 SMT 457.98
And Paise Ninety Eight Only
neat cement at TEN Floor.
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and Rupees Four Hundred Eighty
153 finished even and smooth in C.M. 1:3 ( 1 cement : 3 coarse sand ) including finishing with floating coat of 716.00 SMT 483.79 Three And Paise Seventy Nine
neat cement at ELEVEN Floor. Only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees Five Hundred Nine And
154 finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including finishing with floating coat of neat 151.00 SMT 509.60
Paise Sixty Only
cement at TWELVE Floor.
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and
Rupees Five Hundred Thirty Five
155 finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including finishing with floating coat of neat 101.00 SMT 535.41
And Paise Forty One Only
cement atTHIRTEENTHFloor.
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Two Hundred Three And
156 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 sand ) including finishing with floating 1928.00 SMT 203.34
Paise Thirty Four Only
coat of neat cement slurry at GROUND FLOOR.
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Two Hundred Thirty One
157 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 sand ) including finishing with floating 1396.00 SMT 231.20
And Paise Twenty Only
coat of neat cement slurry at FIRST FLOOR.
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Two Hundred Fifty Nine
158 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 coarse sand ) including finishing with 2146.00 SMT 259.06
And Paise Six Only
floating coat of neat cement slurry at SECOND FLOOR.
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Two Hundred Eighty Six
159 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 coarse sand ) including finishing with 2146.00 SMT 286.92
And Paise Ninety Two Only
floating coat of neat cement slurry at THIRD FLOOR .
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Three Hundred Fourteen
160 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 sand ) including finishing with floating 2146.00 SMT 314.78
And Paise Seventy Eight Only
coat of neat cement slurry at FOURTHFLOOR.
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Three Hundred Forty Two
161 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 sand ) including finishing with floating 2146.00 SMT 342.64
And Paise Sixty Four Only
coat of neat cement slurry at FIFTH FLOOR.
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Three Hundred Seventy
162 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 coarse sand ) including finishing with 2146.00 SMT 370.50
And Paise Fifty Only
floating coat of neat cement slurry at SIXTH FLOOR.
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Three Hundred Ninety
163 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 coarse sand ) including finishing with 2146.00 SMT 398.36
Eight And Paise Thirty Six Only
floating coat of neat cement slurry at SEVEN FLOOR .
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Four Hundred Twenty Six
164 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 sand ) including finishing with floating 2146.00 SMT 426.22
And Paise Twenty Two Only
coat of neat cement slurry at EIGHTH FLOOR.
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Four Hundred Fifty Four
165 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 sand ) including finishing with floating 2146.00 SMT 454.08
And Paise Eight Only
coat of neat cement slurry at NINE FLOOR.
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Four Hundred Eighty One
166 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 coarse sand ) including finishing with 2146.00 SMT 481.94
And Paise Ninety Four Only
floating coat of neat cement slurry at TEN FLOOR.
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Five Hundred Nine And
167 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 coarse sand ) including finishing with 2146.00 SMT 509.80
Paise Eighty Only
floating coat of neat cement slurry at ELEVEN FLOOR .
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Five Hundred Thirty Seven
168 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 sand ) including finishing with floating 369.00 SMT 537.66
And Paise Sixty Six Only
coat of neat cement slurry at TWELVE FLOOR.
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior
Rupees Five Hundred Sixty Five
169 plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 sand ) including finishing with floating 82.00 SMT 565.52
And Paise Fifty Two Only
coat of neat cement slurry at TWELVE FLOOR.
Synthetic Texture Plaster with Double Coat Smooth plaster : Providing 20mm thick cement plaster in
single coat plastering upto for Outside and finished even and smooth in (i) Cement mortar 1:3 (1-cement
: 3-sand) as Base Coat and providing 2-3 mm thick synthetic texture plaster of approved texture
Rupees Six Hundred Two And
170 including cost of all rate are materials, labour, conveyance, loading and unloading, taxes, royalties, 9440.00 SMT 602.22
Paise Twenty Two Only
scaffolding, watering etc.complete for any Height as per Drawing and instructions of Engineer -in -
Charge.(Material Shall be Used as Approved By GSPHCL Only )
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing 10 mm thick CEMENT PLASTER in single coat interior plastering and finished even and
smooth in cement mortar (1:3) (1 Cement : 3 sand) and finishing with a floating coat of neat cement
slurry including providing and mixing WATER PROOFING material in Cement Mortar in proportion
Rupees One Hundred Eighty Three
171 recommended by the manufacturers foundation & plinth. Including finishing with a floating coat of neat 93.00 SMT 183.13
And Paise Thirteen Only
cement slurry. Cement mortar shall be prepared in cement mixter machine only. Water Proofing
compound shall be as per directed by Engineer in charge. Rates are inclusive for ground floors.FOR
Provinding 10 mm thick cement PLASTER in single coat of interior plastering and finished even and
smooth in cement mortar 1:3 ( 1 cement : 3 sand ) and finishing with floating coat of neat cement slurry
Rupees Three Hundred Fifty And
172 including providing and mixing WATER PROFFING material in C.M in proportion recomended by the 1679.00 SMT 350.29
Paise Twenty Nine Only
manufacturer including finishing with a flaoting coat of neat cement slurry. FOR ALL FLOOR
Providing & laying acrylic based modified cementitious composite coating system in two coats.1st coat
Rupees One Hundred Ten And
173 shall be acrylic polymer & cement & second coat shall be of acrylic polymer ,cement & silica sand.The 1679.00 SMT 110.70
Paise Seventy Only
application of both the coats shall be as per manufacturer's manual.
Providing and filling light weight filling material (CINDER) an approved in sunk slabs or as may be Rupees Seven Hundred Ninety One
directed at all floors including watering, consolidation etc.. Complete. And Paise Sixty Eight Only
Providing CEMENT VATA ( 10cm x 10cm )size quarter round in cement mortar 1 : 1 including neat Rupees Twenty Three And Paise
cement finishing, watering etc. Complete. Forty Five Only
Providing & laying Cement Concrete flooring 1:2:4 (1- cement 2; sand 4- M/c graded stone aggregate of
Rupees Three Hundred Forty Eight
176 20 mm nominal size) laid in one layer finished with a floating coat of neat cement (B) 50mm thick. 790.00 SMT 348.08
And Paise Eight Only
Providing, Supplying and Fixing of 32mm (Total) Thick Single Flush Door Shutter with 1mm Thick
Laminates on Both Side of Shutter. Making / Construction of Flush Door is with Pine or southern Yellow
Pine Filler and 2.5mm core veneer Both Side and 0.4mm Face Veneer on Both Side with Lock rail on
Center. Flush Door Provide with Teak wood beading patti (32mm X 12mm) on Peripheries of Flush Door
with Door Frame of Non Teak Solid Wood of size 120mm x 65mm with Chemically Treated and
Rupees Eight Thousand Nine
Seasoned Including Paint Matching with Laminates. Frame & Flush door shutter having 5 year warranty
53.00 SMT 8976.41 Hundred Seventy Six And Paise
against attack of biological agent like termite, borers, decay, fungi and harmful insects also warranty
against seasoning related issues like crack, bending, twisting, warping. Laminates on shutter shall be
press by cold press method. Shutter shall be brought to site in packed PVC bags & pvc coating shall be
removed on completion of work in such a way that shutter & Frame is free from nail mark & any damages
Rates are also Inclusive of all Labors & Proviging 15cm. Long 6 No of Hold Fast (25mm X 5mm) & 3 No
of 6 Inch S.S. but Hinges, 100mm x 75 mm x 3mm thick, required Screw & Nails per Frame and Fixing
following S.S. Fixtures And Fastening.
(1) Aldrops 1 No, 250mm x 16mm & Tadi 1 No, (2) Door Stopper 1 No, 100mm Long, (3) Double Leg
Heavy Push Door Stopper 1 No & (4) Handle 2 No, 150mm Long X 10mm thick. Door are Fixing as per
Details Drawing & Instruction of Engineer in charge. All Materials Used Shall be as Per approved
Material Make List of G.S.P.H.C. The Required Frame is to be Obtained from Vanil Udhyog Maked Only.
Providing, Supplying and Fixing of 32mm (Total) Thick Double Flush Door Shutter with 1mm Thick
Laminates on Both Side of Shutter. Making / Construction of Flush Door is with Pine or southern Yellow
Pine Filler and 2.5mm core veneer Both Side and 0.4mm Face Veneer on Both Side with Lock rail on
Center. Flush Door Provide with Teak wood beading patti (32mm X 12mm) on Peripheries of Flush Door
with Door Frame of Non Teak Solid Wood of size 150mm x 70mm with Chemically Treated and
Rupees Twelve Thousand Eight
Seasoned Including Paint Matching with Laminates. Frame & Flush door shutter having 5 year warranty
7.00 SMT 12870.01 Hundred Seventy And Paise One
against attack of biological agent like termite, borers, decay, fungi and harmful insects also warranty
against seasoning related issues like crack, bending, twisting, warping. Laminates on shutter shall be
press by cold press method. Shutter shall be brought to site in packed PVC bags & pvc coating shall be
removed on completion of work in such a way that shutter & Frame is free from nail mark & any damages
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Rates are also Inclusive of all Labors & Proviging 15cm. Long 8 No of Hold Fast (25mm X 5mm) & 8 No
of 6 Inch S.S. but Hinges, 100mm x 75 mm x 3mm thick, required Screw & Nails per Frame and Fixing
6mm thick Glass on Top of Door Frame with Battens Patti, following S.S. Fixtures And Fastening.
(1) Aldrops 2 No, 250mm x 16mm, (2) Door Stopper 2 No, 100mm Long, (3) Double Leg Heavy Push
Door Stopper 2 No & (4) Handle 4 No, 150mm Long X 10mm thick. Door with Glass are Fixing as per
Details Drawing & Instruction of Engineer in charge. All Materials Used Shall be as Per approved
Material Make List of G.S.P.H.C. The Required Frame is to be Obtained from Vanil Udhyog Maked Only.
Providing, Supplying and Fixing of 32mm (Total) Thick Single Flush Door Shutter with 1mm Thick
Laminates on Both Side of Shutter. Making / Construction of Flush Door is with Pine or southern Yellow
Pine Filler and 2.5mm core veneer Both Side and 0.4mm Face Veneer on Both Side with Lock rail on
Center. Flush Door Provide with Teak wood beading patti (32mm X 12mm) on Peripheries of Flush Door
with Door Frame of Non Teak Solid Wood of size 100mm x 60mm with Chemically Treated and
Rupees Eight Thousand Three
Seasoned Including Paint Matching with Laminates. Frame & Flush door shutter having 5 year warranty
438.00 SMT 8399.74 Hundred Ninety Nine And Paise
against attack of biological agent like termite, borers, decay, fungi and harmful insects also warranty
Seventy Four Only
against seasoning related issues like crack, bending, twisting, warping. Laminates on shutter shall be
press by cold press method. Shutter shall be brought to site in packed PVC bags & pvc coating shall be
removed on completion of work in such a way that shutter & Frame is free from nail mark & any damages
Rates are also Inclusive of all Labors & Proviging 15cm. Long 8 No of Hold Fast (25mm X 5mm) & 4 No
of 6 Inch S.S. but Hinges, 100mm x 75 mm x 3mm thick, required Screw & Nails per Frame and Fixing
following S.S. Fixtures And Fastening.
(1) Aldrops 1 No, 250mm x 16mm & Tadi 1 No, (2) Door Stopper 1 No, 100mm Long, (3) Double Leg
Heavy Push Door Stopper 1 No & (4) Handle 2 No, 150mm Long X 10mm thick. Door are Fixing as per
Details Drawing & Instruction of Engineer in charge. All Materials Used Shall be as Per approved
Material Make List of G.S.P.H.C. The Required Frame is to be Obtained from Vanil Udhyog Maked Only.
Providing and fixing solid PVC Flush Door shutter 24mm thick,made from Co-extruded three layer rigid
PVC foam sheet(single Extruded) with density not less than 600kg/cbm outer layer (0.8-1mm)thick
should be rigid PVC with density of not less than 1400kg/cbm.WPC Door frame upper patti of 24mm X
6mm size. Door should be water proof,Termite proof ,fire retardant&having good screw holding Rupees Four Thousand Five
capacity.proviidng and fixing 100% Solid Wood Plastic composite(WPC) Door Frame 90mmx45mm Hundred Thirteen Only
made from wood plastic composite(single Extruded Process)material with density 780kg/cbm .all as per
specifications drawing as directed by the engineer in charge.
Providing and fixing extrutded Domal Alluminium section window having extrutded alluminium colour
anodized secdtion frame, horizontal Three track member size 79.9mm x 45mm x 1.2mm (Section series
no: 27 x 65, @ Wt. 1.12kg/mt), Vertical member of size 79.9mm x 45mm x 1.2mm (Section @ Wt.
1.12kg/mt) with sliding shutter of horizontal member size 65.1mm x 27mm x 1.2mm (Section @Wt. Rupees Four Thousand Nine
181 0.655kg/mt) Vertical member of size 65.1mm x 27mmx 1.2mm (Section @ Wt. 0.655kg/mt) with 5mm 991.00 SMT 4985.25 Hundred Eighty Five And Paise
thick transparent bronze colour tinted float glass with powder coated alluminium fitting and Fixtures and Twenty Five Only
transparent silicon sealent glass fixing to frame as per details etc. completed for window Including one
mosquitoe jali shutter with both side Locking Arrangment. (Make Jindal)
Providing and fixing Alluminium section window having extruded Aluminum Colour anodized section 3.00 SMT
frame, horizontal Three track member size 92mm x 31.75mm x 1.30mm,@ Wt. 1.07 Kg/mt), vertical
member of size 92mm x 31.75mm x 1.50mm ,@ Wt. 1.06 Kg/mt) with sliding shutters of horizontal
Rupees One Thousand Five
member size 40 mmx18mm x1.29mm ,@ wtof 0.456 Kg/mt), vertical member of size 40mm x 18mm x
182 Hundred Sixty Eight And Paise
1.29 mm ,@ wt.of 0.456Kg/mt/ with 5 mm thick transparent bronze colour tinted float glass with powder
Twenty Seven Only
coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per details
including one mosquitoe jali shutter With Both Side Locking Arrangment.
Providing and fixing standard extruded of alluminium section of size 63 * 38.10 * 1.2 mm,@Wt 0.643 Rupees One Thousand One
183 Kg/RMT )with colour aNOdized alluminium frame for ventilation with 5 mm thick frosted glass as details 47.00 SMT 1163.92 Hundred Sixty Three And Paise
etc complete FOR VENTILATION Ninety Two Only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing & Laying integrated cement based proprietary water proofing treatment of required thickness
over the roof including 10mm thick cement mortar 1:3 and CHINA MOSAIC fitting and finally finishing the
surface with white cement slurry and sloping out terrace slabs withFollowing specification laid to required
slope not flatter than 1:80 ( the thickness of water proofing treatment near rainwater outlet or the lowest
point of the finished slope shell not to be less than 45 mm. Including treating the vertical surface of the
parapet wall up to 20 cm. height above finished level of terracing including finishing top with joint less
Rupees Eight Hundred Fifty Five
water proofing plaster curing testing etc, completed. Rate is Including 10 years performance of guarantee 838.00 SMT 855.11
And Paise Eleven Only
bond to be given on stamp paper ( no extra shall be paid for increase in thickness for proper slope ). (A)
Applying & grounting a slurry coat of neat cement using 2.75 kg/smt. of cement admixed with proprietary
water proofing compound confirming to IS 2645 and 10mm. Thick water proofing cement plaster in
cement mortar in 1:3.over the RCC slab including cleaning the surface before treatments.
(B) Laying cement concrete using broken brick bat
using 25 mm to 40 mm size with 50% of cement mortar 1:4 ( 1 cement : 4 corse sand )over 10mm. thick
water proofing cement plaster in cement mortar in 1:3 admixed
with proprietary water proofing compound conforming to IS 2645 required slope and treating similarly the
adjoining walls up to 200 mm height including rounding of
junction of walls.
(C) After two days of proper curing applying a second coat of cement slurry .
(D) Finishing the surface with china mosaic peices laid on 10 mm thick joint less cement mortar of mix
1:3 ( 1 cement : 3 sand) admixed with proprietary water proofing compound confirming to IS 2645 and
finally finishing the surface with trowel with neat cement slurry .
E) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for
curing for final test. All above operation to be done in order and as directed and specified by the engineer
Providingand laying 24" x24"Double Charge Vitrified Tiles 8 to10mm thick in Flooring over 20mm
(average) baseof cementmortar 1:6 ( 1cement: 6coarsesand) onnewsurfaceorfixingonexisting
Rupees One Thousand Four
flooringbyadhesiveincludingdismentalingofexistingflooringandmaterial jointedwithcolorcementslurry
185 6464.00 SMT 1440.20 Hundred Forty And Paise Twenty
including finised with flush pointing & cleaning the surface etc. complete for Light shade for all
floors.Material shall be used as approved by GSPHCL
Providingand laying 24" x24" Double Charge VitrifiedTiles 8 to10mm thick inSkirting over 10mm
(average) baseof cementmortar 1:3 ( 1cement: 3coarsesand) onnewsurfaceorfixingonexisting
Rupees One Thousand Three
flooringbyadhesiveincludingdismentalingofexistingflooringandmaterial jointedwithcolorcementslurry
186 598.00 SMT 1392.20 Hundred Ninety Two And Paise
including finised with flush pointing & cleaning the surface etc. complete for Light Shade for all
floors.Material shall be used as approved by GSPHCL
Providing and laying 25mm thick Machine cut Rough KOTA STONE SLAB FLOORING over 20mm
average thick base of cement mortar 1:6 ( 1 cement : 6 coarse sand) laid over & jointed with grey cement Rupees Seven Hundred Five And
slurry including rubbing & polishing etc. Complete. as Directed By Engineer In Charge for all Floors. Paise Thirty Nine Only
Providing and Laying Mirror Polished 25 mm thick Double Diamond Polished Kota Stone Flooring over
20mm thick base of cement mortar 1 : 6 (1-Cement : 6-Coarse Sand) laid over and jointed with grey
Rupees One Thousand Eighty One
188 cement slurry including Rubbing and Polishing etc. Complete. (A) 25mm Thick. In Green Colour. Rate 1129.00 SMT 1081.90
And Paise Ninety Only
Are Inclusive of Single Piece & Making 3 Line Groove and Moulding Of Outer edge as Directed By
Engineer In Charge.
Providing and Laying Mirror Polished 25 mm thick Double Diamond Polished SLAB in RISERS of steps, Rupees One Thousand Two
189 dedo , skirting and pilllars laid to 10 mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand) & jointed 204.00 SMT 1275.10 Hundred Seventy Five And Paise
with grey cement slurry including rubbing & polishing etc Ten Only
Providing and laying Anti skid Ceramic tiles (Non Skiding) 8 mm to 10mm thick in Floorings, treads of
steps and landing laid on a bed of 20 mm thick cement mortar 1:3 (1 - cement: 3- coarse sand) finished Rupees Nine Hundred Sixty And
with flush pointing in the colour as specified etc. complete in white cement for All Floors. Size and shade Paise Forty Seven Only
shall be as per the instruction of Engineer - In - Charge.
Providing and laying Ceramic tiles 8 mm to 10mm thick in skirting, risers of steps and DADO on 10mm
thick cement mortar 1:3 (1-cement: 3 coarse sand) finished with flush pointing in the colour as specified Rupees One Thousand Twenty
etc. complete in white cement for All Floors. Size and shade shall be as per the instruction of Engineer - Eight And Paise Eleven Only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and fixing both side polished machine cut KOTA STONE shelve/ partition 20mm to 25mm
thick embaded in to wall at support including racking and finishing smooth the surface including cutting Rupees Seven Hundred Ninety
the stone as and where required etc. complete including rounding of exposed edges etc. complete. Three And Paise Ninety Only
Providing and laying rubber flooring of size 480 mm x 480 mm having thickness 15 mm including the
Rupees Two Thousand One
cost of all labour,tools,other incidental expenses etc.necessary for completion of work as directed by the
193 311.00 SMT 2103.58 Hundred Three And Paise Fifty
ineer in charge. ( Including labour charges of Supply and Installation of Rubber flooring)
Providing and Fixing Granite Telephonic Black Colour 15 to 18 mm thick for jambs and sills of
doors & windows using neat cement slurry laid over 20 mm average base of cement mortar 1:1(1
cement:1 Coarse Sand) and jointed with grey cement slurry including racking(Tancha Work) rubbing and Rupees Two Thousand Four
polishing,scaffoldings,tools and tackles,scaffolding etc. complete(with base of neat cement) as per Hundred Twenty Eight Only
direction of Engineer in charge including rounding the exposed edges as directed.
Finishing Ceilling/Slop Surface with Plastic EmulsionPaint on Ceilling/Slop Surface(twocoats) to
givean required shap evenshadeafter throughl ybrushing the surface to removeall dirt and remainsof
loose powedermaterial etc. complete.Rateare inclusiveofapplyingtwocoat of lapy(Putty)andonecoat of
Rupees One Hundred Eighty Six
195 primer on new Ceilling/Slop Surface to givean devenshade including thoroughly brushing the surface free 9875.00 SMT 186.73
And Paise Seventy Three Only
from morta rdropping and other foreign matter and sand paperedsmooth.putty,primer&paints hallbeas per
approved list of GSPHCL
Finishing Wall with Plastic Emulsion Paint on Wall Surface (two coats) to give an required shap
even shade after throughly brushing the surface to remove all dirt and remains of loose poweder material
etc. complete. Rate are inclusive of applying two coat of lapy (Putty) and one coat of primer on new wall Rupees One Hundred Seventy Six
196 surface to give and even shade including thoroughly brushing the surface free from mortar dropping and 25189.00 SMT 176.33
And Paise Thirty Three Only
other foreign matter and sand papered smooth. putty , primer and paint make as per the approved list of
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) over and above
applying One Coat Of Primer to give an required shape even shade after thoroughly brushing the
Rupees One Hundred Forty Seven
197 surface to remove all dirt, and remains of loose powdered materials.etc complete. primer and paint make 9479.00 SMT 147.68
And Paise Sixty Eight Only
as per the approved list of GSPHCL
Providing & Fixing 15mm One way Bib Tap with Wall Flange. Rate are inclusive of all matreials, Labour
& Necessary Fittings etc. Complete as per Detailed Drawings, Specifications and as per the Instruction of Rupees Nine Hundred Ninety And
Engineer In charge. The Model & Make of Bib Tap Shall be as per the Approved Make List of GSPHCL. Paise Sixty One Only
Providing and fixing of Wall mixer with Wall Flange (With Seals), Button Assembly Sleeve & Buttonr,
Rupees Five Thousand Two
199 spout etc 124.00 NO 5251.00
Hundred Fifty One Only
complete the job , including cutting and making good the walls etc.
Providing & Fixing Two way Bib Tap with Wall Flange. Rate are inclusive of all matreials, Labour &
Necessary Fittings etc. Complete as per Detailed Drawings, Specifications and as per the Instruction of Rupees One Thousand Three
200 Engineer In charge. The Model & Make of Two way Bib Tap Shall be as per the Approved Make List of 105.00 NO 1309.39 Hundred Nine And Paise Thirty
GSPHCL. Nine Only
Providing & Fixing Health Faucets (ABS Body). Rate are inclusive of all matreials, Labour & Necessary
Fittings etc. Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In
Rupees Five Hundred Sixty Five
201 charge. The Model & Make of Health Faucets Shall be as per the Approved Make List of GSPHCL. 105.00 NO 565.51
And Paise Fifty One Only
Providing and laying G.I.RAIN WATER SPOUT of 50 mm dia and 0.30 m length. Rupees One Hundred And Paise
Providing & Fixing Single Hole Wash Basin with C.I or M.S. brackete & M. I. fisher union, P.V.C water
pipe with Connection from Stop Cock to Pillar Tap, PVC Bottle Trap with Connection 32mm dia. C.P.
brassa waste coupling etc. Complete. Rate are inclusive of all matreials, Labour & Necessary Fittings Rupees Three Thousand Nine
203 etc. Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In charge. 85.00 NO 3935.33 Hundred Thirty Five And Paise
The Model & Make of Wash Basin Shall be as per the Approved Make List of GSPHCL. including pillar Thirty Three Only
cock, angel cock, bottale trap
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing & Fixing Single Hole Table Top Wash Basin on Granite Slab with C.I or M.S. brackete & M. I
. fisher union, P.V.C water pipe with Connection from Stop Cock to Pillar Tap, PVC Bottle Trap with
Connection 32mm
Rupees Three Thousand Three
dia. C.P. brassa waste coupling etc. Complete. Rate are inclusive of all materials, Labour & Necessary
204 20.00 NO 3326.94 Hundred Twenty Six And Paise
Fittings etc. Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In
Ninety Four Only
charge. The Model & Make of Table Top Wash Basin Shall be as per the Approved Make List of
Provinding and fixing 600mm x 450mm bevelled edge MIRROR or superior glass mounted on 6mm
Rupees Eight Hundred Twenty Five
205 thick A.C. sheet of plywood sheet fixed to wooden plugs with C.P. brass screws & washers. 105.00 NO. 825.48
And Paise Forty Eight Only
Providing & Fixing Towel Ring. Rate are inclusive of all matreials, Labour & Necessary Fittings etc.
Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In charge. The Rupees Nine Hundred Nine And
Model & Make of Towel Ring Shall be as per the Approved Make List of GSPHCL Paise Eight Only
Providing & Fixing Towel Rod. Rate are inclusive of all matreials, Labour & Necessary Fittings etc.
Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In charge. The Rupees One Thousand Seventy
Model & Make of Towel Rod Shall be as per the Approved Make List of GSPHCL. Eight And Paise Seventy Only
Providing & Fixing Towel Rack. Rate are inclusive of all matreials, Labour & Necessary Fittings etc.
Rupees Three Thousand Three
Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In charge. The
208 105.00 NO 3343.63 Hundred Forty Three And Paise
Model & Make of Towel Rack Shall be as per the Approved Make List of GSPHCL.
Sixty Three Only
providing and fixing SS cloth HANGER (5 hook ) as per detailed drawing and as directed by engineering
Rupees Two Hundred Forty Nine
209 incharge. Rate are inclusive of all material,labour, taxes. As per approved list of GSHPHCL 125.00 NO. 249.85
And Paise Eighty Five Only
210 Providing and fixing 20 mm dia Alluminium rod with Alluminium chapla etc. complete. 160.00 RMT 80.00 Rupees Eighty Only
Providing & Fixing Wall Hung with PVC Flush Tank, Soft Seat Cover & intergal "P" or "S" Trap including
Jointing the Trap with Pan and Soil pipe. Wall hung shall be fixed on S.S heavy duty rack bolt having
Rupees Five Thousand Four
16mm dia, 165mm length using Plastic sleeve Make by Using Drill Bitt Only. Rate are inclusive of all
211 106.00 No. 5470.90 Hundred Seventy And Paise Ninety
matreials, Labour & Necessary Fittings etc. Complete as per Detailed Drawings, Specifications and as
per the Instruction of Engineer In charge. The Model & Make of Wall Hung & Flush Tank Shall be as per
the Approved Make List of GSPHCL.
Providing & Fixing Shower with Arm. Rate are inclusive of all matreials, Labour & Necessary Fittings
etc. Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In charge. Rupees Nine Hundred Thirty One
The Model & Make of Shower with Arm Shall be as per the Approved Make List of GSPHCL. And Paise Seventy Nine Only
Providing & Fixing 15mm Concealed Heavy Duty Stop Cock with Exposed Part & Other Accessories
(Sleeve, Lever, Wall Flange). Rate are inclusive of all matreials, Labour & Necessary Fittings etc.
Rupees Nine Hundred Forty Two
213 Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In charge. The 103.00 No. 942.54
And Paise Fifty Four Only
Model & Make of Concealed Heavy Stop Cock Shall be as per the Approved Make List of GSPHCL.
Providing and Fixing concealed centre point to wall ceiling and floor CPVC ( SDR 13.5) poipe having
National sanitation foundation ( NSF) seal for potable water of following dia. Nominal bore tube fittings
Rupees Two Hundred Two And
214 and clamps including, making good the wall,ceiling and floor etc complete.Pipe shall be concealed or 1050.00 RMT 202.97
Paise Ninety Seven Only
open as per mentioned in tender description.Pipe shall be approved make of GSPHCL list (20 mm
Providing and Fixing concealed centre point to wall ceiling and floor CPVC ( SDR 13.5) poipe having
National sanitation foundation ( NSF) seal for potable water of following dia. Nominal bore tube fittings
Rupees Two Hundred Forty Seven
215 and clamps including, making good the wall,ceiling and floor etc complete.Pipe shall be concealed or 670.00 RMT 247.25
And Paise Twenty Five Only
open as per mentioned in tender description.Pipe shall be approved make of GSPHCL list (25 mm
Providing and fixing concealed or open center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings
Rupees Three Hundred Thirty And
216 with Z patti (Minimum 1.6mm thick) with 6mm Dia U Clamp with washer for Vertical water supply pipe. 670.00 RMT 330.36
Paise Thirty Six Only
Pipe shall be concealed or open as mention in tender description. Pipe shall be as per approved make of
GSPHCL make list (32 mm inside dia).
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and fixing concealed or open center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube
Rupees Four Hundred Thirty Seven
217 fittingswith Z patti (Minimum 1.6mm thick) with 6mm Dia U Clamp with washer for Vertical water supply 1018.00 RMT 437.66
And Paise Sixty Six Only
pipe. Pipe shall be concealed or open as mention in tender description. Pipe shall be as per approved
make of GSPHCL make list (40 mm inside dia).
Providing and fixing concealed or open center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube
Rupees Six Hundred Forty Seven
218 fittingswith Z patti (Minimum 1.6mm thick) with 6mm Dia U Clamp with washer for Vertical water supply 638.00 RMT 647.30
And Paise Thirty Only
pipe. Pipe shall be concealed or open as mention in tender description. Pipe shall be as per approved
make of GSPHCL make list (50 mm inside dia).
Providing & Fixing to Wall Ceilling and Floor SWR (Type A) Rain Water pipe as Per IS-13592 of 90mm
Dia. Complete with Special Flings, vent cowl, Compressor type Fittings like G.I. Slotted Z patti of
Gauge (minimum1.60mm thick) and minimum 6mm dia. U Clamp with Washer Nut at every 1.50mt.
Rupees Three Hundred Twenty
219 vertical distance including All Labour Charges etc. complete including making good the Ceilings, Floors 899.00 RMT 323.15
Three And Paise Fifteen Only
and on terrace. Rain water pipe shall be 90 mm Dia. SWR horizontal pipe and vertical pipe and 90mm
bend at the end near by Ground level. Rate are Inclusive of all Necessary Fittings required for ALL
Providing and fixing to wall, ceiling and floor U.PVC SWR (Type-B) Soil Waste Pipe with 'O' Ring
mm dia. of ISI 13592/92. Rate inclusive of All fittings like single or double 'Y' with door, reducer, coupler
single 'T' with door bend, Vent cowl, G.I. Slotted Z patti of 16 Gauge (minimum1.60mm thick) and Rupees Two Hundred Sixty Four
minimum 6mm dia. U Clamp with Washer Nut at every 1.50mt. vertical distance including All Labour And Paise Ninety Seven Only
Charges etc. complete and making good the Wall, Ceiling and Floor.
Providing and fixing to wall, ceiling and floor U.PVC SWR (Type B) Soil Waste Pipe with 'O' Ring
110 mm dia. of ISI 13592/92. Rate inclusive of All fittings like single or double 'Y' with door, reducer,
coupler single 'T' with door bend, vent cowl,G.I. Slotted Z patti of 16 Gauge (minimum1.60mm thick) and Rupees Four Hundred Ninety Five
minimum 6mm dia. U Clamp with Washer Nut at every 1.50mt. vertical distance including All Labour And Paise Ninety One Only
Charges etc. complete and making good the Wall, Ceiling and Floor.
Provinding and fixing in position SWR/UPVC COWEL VENT to pipe 75 mm dia directed. Rupees Sixteen And Paise Forty
Provinding and fixing in position SWR/UPVC COWEL VENT to pipe 110 mm dia directed. Rupees Twenty Eight And Paise
Providing & fixing PVC SWR MULTY NANHI TRAP IS:14735 for drain -100mm dia. With jali of following
nominal dia. of self cleansing design with C.I. Screwed down or Hinged grating including the cost of
cutting and making good the walls. Providing & Fixing Floor drain jali (Glossy Finish) (on N.T.) of 6" X Rupees One Thousand One
224 6"size made of Stainless Steel Grade 304 Floor Drain 3 Piece (Cover/Jali/Grating) With Anti Cockroach 147.00 NO 1122.26 Hundred Twenty Two And Paise
Bowl on N.T. Rate are inclusive of all necessary fittings, material, labour etc.complete as per direction of Twenty Six Only
Engineer In charge.
Construction of BRICK MASONRY CHAMBER for under Ground C.I. inspection chamber and bends with
bricks having crushing strength not less than 35 Kg / Cm2 in Cement Mortar (1:5) with RCC top slab with
CC (1:2:4) mix ( 1 cement : 2 corse sand : 4 gradded aggregate 20 mm nominal size) with 8mm. dia.
TMT steel at 15 cm. c/c both ways & providing and fixing precast r.c.c cover size .60 x .45 x .07 mt. with
Rupees Three Thousand Seven
angle frame fixed with C.C (1:2:4) Foundation concrete 1:5:10, inside plaster 15 mm thick with C:M (1:3)
225 42.00 NO. 3793.18 Hundred Ninety Three And Paise
finished smooth with a floating coat of neat cement slurry on walls & bedconcrete etc, complete. Inside
dimension of chamber 455 mm x 610 mm x 450 mm deep for match proposed pipe line. Rate are also Eighteen Only
inclusive of out side plaster 15mm. th. in c:m 1:3 from top of the chamber & all side up to 15 mm. deep
below ground level. Including precast cover.
Construction of BRICK MASONRY CHAMBER for under Ground C.I. inspection chamber and bends with
bricks having crushing strength not less than 35 Kg / Cm2 in Cement Mortar (1:5) with RCC top slab with
CC (1:2:4) mix ( 1 cement : 2 corse sand : 4 gradded aggregate 20 mm nominal size) with 8mm. dia.
TMT steel at 15 cm. c/c both ways & providing and fixing precast r.c.c cover size .60 x .45 x .07 mt. with
Rupees Five Thousand Four
angle frame fixed with C.C (1:2:4) Foundation concrete 1:5:10, inside plaster 15 mm thick with C:M (1:3)
226 10.00 NO. 5476.93 Hundred Seventy Six And Paise
finished smooth with a floating coat of neat cement slurry on walls & bedconcrete etc, complete. Inside
Ninety Three Only
dimension of chamber 610 mm x850 MMX 450 mm deep for match proposed pipe line. Rate are also
inclusive of out side plaster 15mm. th. in c:m 1:3 from top of the chamber & all side up to 15 mm. deep
below ground level.Including precast cover.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone
aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1 cement : 3- coarse sand :6- Brick bats
40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:3 (1-Cement : 3-coarse sand)
finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-
Cement :2-Coarse sand :4- stone aggregate 20mm nominal size) finished smooth complete including Rupees Thirteen Thousand Seven
227 curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 2.00 NO. 13715.57 Hundred Fifteen And Paise Fifty
560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Seven Only
Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not
less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5- Coarse sand) (2) B type depth 1.50 Metre
for 150mm diameter sewer.
Extra rate for constructing chamber for every additional depth of 0.1 m or part there of FOR 455MM X Rupees Two Hundred Thirty Nine
610MM And Paise Ninety Nine Only
Extra rate for constructing Chamber for every additional depth of 0.1 m or part there of FOR 600 MM X
Rupees Three Hundred Twenty
Two And Paise Thirty Seven Only
Extra rate for constructing manholes for every additional depth of 0.1 m or part there of FOR MANHOLE
Rupees Three Hundred Ninety
Three And Paise Twenty Six Only
Providing,supplying and fixing Corrugated DWC HDPE pipe of Class SN8 Structured Wall polyethelene
Piping systems (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External
Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground
Sewerage & Drainage application as per EN:13476-3 including all local and central taxes, transportation,
freight charges, octroi, inspection charges, loading, unloading, conveyance etc. complete. (150 mm ID
Dia) Including Lowering, laying and jointing of class SN 8 structured wall ( External Annular Corrugated &
Smooth Internal surface) Polyethylene Piping and fittings with the help of coupler ( on line / off line ) Rupees Three Hundred Ninety Six
attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified Only
valley of the corrugation at the spigot end, lowering the same into the trench, laying on the lower bedding
(constructed at bottom of trenches) at prescribed gradient,depth & alignment ,testing the water tightness
of the joints, ensuring the continuity tests of specified pipe segments etc. complete as per
drawing,specifications & detailed engineering, including carriage of pipes & fittings from site stacks to the
place of laying etc. as per direction of Engineer-in-charge.
Providing,supplying and fixing Corrugated DWC HDPE pipe of Class SN8 Structured Wall polyethelene
Piping systems (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External
Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground
Sewerage & Drainage application as per EN:13476-3 including all local and central taxes, transportation,
freight charges, octroi, inspection charges, loading, unloading, conveyance (200 mm ID Dia) Including
Lowering, laying and jointing of class SN 8 structured wall ( External Annular Corrugated & Smooth
Internal surface) Polyethylene Piping and fittings with the help of coupler ( on line / off line ) attached with
Rupees Seven Hundred Seventy
232 one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the 170.00 RMT 771.00
corrugation at the spigot end, lowering the same into the trench, laying on the lower bedding (constructed
at bottom of trenches) at prescribed gradient,depth & alignment ,testing the water tightness of the joints,
ensuring the continuity tests of specified pipe segments etc. complete as per drawing,specifications &
detailed engineering, including carriage of pipes & fittings from site stacks to the place of laying etc. as
per direction of Engineer-in-charge.
Providing & Fixing Stop/Angle cock 25mm Rate are inclusive of all materials, Labour & Necessary
Fittings etc. Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In Rupees One Thousand Two
233 charge. The Model & Make of Shower with Arm Shall be as per the Approved Make List of GSPHCL.
69.00 NO. 1233.57 Hundred Thirty Three And Paise
Fifty Seven Only
Providing & Fixing Angle Cock with Wall Flange . Rate are inclusive of allmaterials, Labour & Necessary
Fittings etc. Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In Rupees Six Hundred Sixty Five
charge. The Model & Make of Angle Cock Shall be as per the Approved Make List of GSPHCL. And Paise Fifty One Only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Provinding and fixing gun metal check or non return full way WHEEL / HANDLE VALVE Rate are
inclusive of all matreials, Labour & Necessary Fittings etc. Complete as per Detailed Drawings, Rupees Six Hundred Fifty Six And
Specifications and as per the Instruction of Engineer In charge. All material used as per approved make Paise Eighty Six Only
list by GSPHCL. (40 mm inside dia).
Provinding and fixing gun metal check or non return full way WHEEL / HANDLE VALVE Rate are
Rupees Two Thousand Three
inclusive of all matreials, Labour & Necessary Fittings etc. Complete as per Detailed Drawings,
236 16.00 NO. 2302.33 Hundred Two And Paise Thirty
Specifications and as per the Instruction of Engineer In charge. All material used as per approved make
list by GSPHCL. (50 mm inside dia).
237 Painting Numbers or name on Acrylic plate as Directed by Engineer in Charge. 63.00 NO. 100.00 Rupees One Hundred Only
Providing a I.S.I. mark 7 lavers three keys brass pad lock of NAVTRAL (godrej) make 65mm dia on Rupees Two Hundred Eleven And
completion of porject. Paise Eighty Six Only
Providing,Fabricationandfixing M.S.Grill /GATE of approved patter nfabricatedfromM.S. flat,Square Bars,
roundbars,Cchannel, square/roundboxpipeasperdetaildrawings.Rate is inclusiveofwelding
Rupees Seventy Four And Paise
239 withgrindingandapplyingofmildsteelputtywithhardener intogroovetohavesmoothsurface, twocoats of oil 36863.75 KG. 74.92
Ninety Two Only
paint and one coat of yellow zinc chromate primer coat as per the Approved Make List of GSPHCL
Providing and fixing chicken wire mesh jali of 20 guage with necessary screws and nails at joints or
Rupees Sixty Four And Paise Six
240 crackes of brick work or RCC work, as per drawing, spicification and direction of Engineer in charge.wire- 1501.00 SMT 64.06
mesh jali shall confirm to relevant IS specification.
Providing and fixing letter box having a size of 300mm x 250 mm as per instruction of engineer in
241 24.00 nos 560.00 Rupees Five Hundred Sixty Only
Providing , carving & Fixing of a Granite takti of size 0.30mtr x0.30mtr as per instruction of Engineer
242 1.00 Nos 1000.00 Rupees One Thousand Only
Providing and fixing 1050mm high S.S. railing made from S. S. pipe of 50mm dia & 1.5mm thick, SS
316 grade horizontal at top for hand rail and with 50mm dia & 1.5mm thick, SS 316 grade SS top
mounted round baluster as a vertical member fixed in Block ledge wall with double glass holding
Rupees Fifteen Thousand One
accessories, with 12mm thick toughened glass (upto 775mm height) fixed with 100mm dia x 8mm thick
243 155.00 RMT 15171.26 Hundred Seventy One And Paise
316 grade base plate with cover cap with 2No.. Hilti GI M10x80mm as per drawing using grouting
Twenty Six Only
material as directed by engineer in charge. Rate are inclusive of all material, labour, taxes, polishing etc.
and fixing complete. (Kich or equvalent)
Providing and Fixing of stainless steel 304 grade pipe railing.0.9 mtr. Height top pipe of 2" dia , vertical
balustrade 1.0 " x1.0" at every max. 0.9 mt c/c, fixed with stone/concrete or brickwork, Balustrade as Rupees Nine Hundred Eleven And
directed by engineer in charge. Rate are inclusive of all material,labour,taxes &polishing. Paise Three Only
Providing upto floor two level precast cement concrete jali or grill 1:2:4 mix (1- Cement : 2- coarse sand :
4-graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia. Mild steel wire including Rupees Six Hundred Forty And
roughening,cleaning, fixing and finishing in cement mortar 1:3 and curing complete. (B)40 mm thick Paise Twenty Only
providing & fixing Door Eye glass ultra clear 180 degree finished with Brass as per detailed drawing and
Rupees Two Hundred Forty Eight
246 as directed by engineer incharge. Rate are inclusive of all material, labour and taxes. 20.00 NO 248.31
And Paise Thirty One Only
Providing and fixing both side polished machine cut Granite Shelves / Partitions 18mm thick embaded
Rupees Two Thousand One
in to wall at support including racking and finishing smooth the surface including cutting the stone as and
247 15.00 SMT 2115.40 Hundred Fifteen And Paise Forty
where required etc. complete including rounding of exposed edges etc. complete.
supplying j and installation of GRC jali thickness 25mm , grade M-40 ,Flexural M8 , Backside double
Rupees Seven Thousand Three
coated frame fabrication at site including installation at site, transportation loading , unloading all with
248 151.00 SMT 7379.10 Hundred Seventy Nine And Paise
both sides weather proof emulsion paint etc complete as directed by EIC (For NRB Elevation Only)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Gypsum False Ceiling Providing and fixing gypsum board ceiling as per manufactures' specifications
incl. acrylic paint. Fixing of suspended gypsum plain false ceiling by using standard company section
(GYPSTEEL ULTRA), which includes providing and fixing G.I. parameter channels of size 20 X 28 X
X 0.55 mm thick having one flange of 20 mm and another flange of nylon sleeves and screws at 610 mm
center. Then suspending G.I intermediate channels of size 15 X 45 X 15mm, 0.9 mm thick fixed with two
flanges of 15 mm each from the sophist at 1220 mm center with ceiling angle of width 25 mm x 10 mm x Rupees One Thousand Two
0.55 mm thick fixed to sophist with G.I. cleat and steel expansion fasteners. Ceiling section of 0.55 mm. 504.00 SMT 1219.89 Hundred Nineteen And Paise
thickness having knurled web of 51 mm. and two flanges of 26 mm each with lips of 10.5 mm. area then Eighty Nine Only
fixed to the intermediate channel with the help of connecting clips and in direction perpendicular to the
intermediated channel at 457 mm. center 12.5 mm tapered edge gypsum board (conforming to is 2095-
1982) is then screw fixed to ceiling section with 25 mm drywall screws at 230 mm center.
Screws fixing is done mechanically either with screwdriver or drilling machine with suitable attachment.
Standard company manufactured section (GYPSTEEL ULTRA) should be used for the entire framework.
Finally the board are to be jointed and finished, so as to have a flush look which includes filling and
finishing the tapered and square edges of the boards with jointing compound, paper tape and two coats
of primer suitable for Gyp-board (as per recommended practices of India Gyproc - Saint Gobain make).
(also including application of primer and preparing surface even & sand papered smooth with lapi,
astar...) Including three coats with plastic emulsion paint of approved brand & manufacture. Including all
materials and labour etc. complete as per detail drawing and instruction of engineer-in charge.
Providing & Fixing 600mm dia. loop hot dip galvenised iron concertina coil made out of 2.5mm dia wire
22mm long razor sharp barbs at 35mm center fitted on 40mm x 40mm x 5mm M.S. Angle post of
required shape & size at 3.00 mt. center distance. concertina coil shall be fixed on M.S. Angle stand with
Rupees Six Hundred Thirty Two
250 the help of 4 Nos. RBT wire M.S. Angle stand shall be fixed on top of Compound wall with 0.20mt x 203.00 RMT 632.00
0.31mt x 0.40mt. deep block in controlled cement concrete M-250. Rate is including of applying one coat
of primer and three coats oil painting on M.S. Angle stand shall be made as per the drawing supplied or
as directed by engineer in charge.
Providing and filling the expansion joint by Thioflex 600 polymer or equivalnt confirm to BS 4254-1983 as
per required shade and manufactured specification by making groove of 50 mm X 12.5 mm lather by
Rupees Five Hundred Ten And
251 cutting or by repairing groove and removing mortar drop or any other foreign materials including applying 5.00 SMT 510.29
Paise Twenty Nine Only
primer and filling required size ( over size) of joint PU foam etc. complete
252 Providing & Laying lawn for Land Scaping including watering & all labours 700.00 SMT 150.00 Rupees One Hundred Fifty Only
Providing & Laying tree plantation rate are also inclusive of maintaing the tree plant in live condition at
253 the time of completion of work at the time of Excavation of the building i.e. initial starting time (the tree 100.00 No. 600.00 Rupees Six Hundred Only
shall be minimum 1.50mt height).
Provding and fixing pre-cast Rubber Dye/ steel Dye inter locking concrete block 60 mm thick with grade
of concrete M-300 pnumatic compressed / Vibrated mechanically pressed and as per approved design Rupees Six Hundred Eighty And
and IS 15658 : 2006 including 35 mm Sand layer for levelling and filling the joint with sand in proper line Paise Ten Only
and level as per guidlines of IRC : SP 63-2018 etc. complete.
Providing and fixing Precast Concrete Kerb Stone of Grey Cement Based Concrete Block size of 30 cm
Length, 30 cm Height and 15 cm thick of M-250 Grade Concrete as per approved design in required
Rupees Three Hundred Fifty Eight
255 colour (Red, White, and Yellow) and Including Excavation For Fixing In proper Line And Level, Filling The 370.00 Rmt 358.06
And Paise Six Only
Joint C:M 1:3 (1 Cement : 3 Fine Sand) etc. Complete.
Providing and Corrugated JSW pre coated sheet roofing fixed with galvanized iron J or L hooks,bolts and
Rupees Nine Hundred Seventy
256 nuts 8mm diameter with bitumen and G.I limpet washer or G.I limpet washer with white lead complete 150.00 SMT 977.38
Seven And Paise Thirty Eight Only
excluding the cost of purlins,rafters and trusses. (0.60mm thick)
Box cutting the road surface to proper slope and camber for making a base for road work including
Rupees One Hundred One And
257 removing the excavated stuff and disposing on the road side slope as directed up to any lead. 452.00 CMT 101.91
Paise Ninety One Only
Construction of Granular Sub base by Providing Couarse graded material Spreading in uniform Layers
Rupees One Thousand Four
With motor grader on prepared surface mixing by mix in place method with rotavator at OMC and
258 128.00 CMT 1441.28 Hundred Forty One And Paise
Compacting with Vibratory roller to achieve the desired density complete as per table 400-2
Twenty Eight Only
Supplying of graded stone aggregate of following sizes (for W.B.M. Road) ( 3) Crushed stone aggregate
Rupees Nine Hundred Ninety
259 for Hard Quality up to 63 mm stze 96.00 CMT 997.21
Seven And Paise Twenty One Only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Spreading the stone aggregate for rolling and W.B.M. including filling the interstices to required camber
Rupees Two Hundred Forty Seven
260 and gradient (excluding spreading of Blindage) (ii) 40mm to 63mm size aggreagates (H.B.) 96.00 CMT 247.28
And Paise Twenty Eight Only
Supplying of murum on W.B.M surface etc. complete Rupees Two Hundred Ninety Two
And Paise Forty Only
Spreading blidage or road crust filling the gaps in metal and leveling to cambert and gradient as directed Rupees One Hundred Forty Six
.(i)Murrum And Paise One Only
Rolling & consolidation water bound macadam (except laterite and kankar) including watering not
exceeding 150mm thk. (Main layer incl. binding materials) includining filling in depression which occurs Rupees Twenty And Paise Seventy
during the process. (A)with Power roller exceeding 8 tonne and not exceeding 12 tonnes Nine Only
Construction Of Concrete Road Using Trimix System Having of any Thickness M-300 Ready Mix
Concrete With Providing And Fixing & Removing Of "C" Channel Having Size 75Mm. X75Mm As Per
Required Level Slope And Thickness Of Concrete Road Floor Levelling Of Place Concrete With Surface Rupees Five Thousand One
264 Vibrator Machine,Dewatering System Device Finishing With Power Floater Machine And Trowel Light 229.00 CMT 5175.24 Hundred Seventy Five And Paise
Brooming On The Surface As Directed With Providing Expansion Joint Size 20 X 190Mm. Using Of Twenty Four Only
Concrete Cutter Machine Including Curing Etc. Complete.
Providing and lixing pre- moulded compressible filler board in black colour confirming to MORT&H
Specifications (Clause 1015). having minimum density 95kg/cum.metre, non-staining with less than 1% Rupees Seven Hundred Eighty
265 water absorption & compression recovery of 93% minimum as per specification for 20 mm wide 36.00 SMT 788.78 Eight And Paise Seventy Eight
expansion joint including cutting to required size and shape at all levels etc. complete as directed. Only
Providing and fixing 25 mm diameter backup rod having minimum density 22 kg per cum (ASTMD -
Rupees Seventeen And Paise Forty
266 3575) & compression strength of 0.40 kg per sqm (ASTM 5249) and finishing with polysulphide sealant 46.00 RMT 17.48
etc. complete. For 20 mm wide expansion joint
Providing Groove cutting in C.C. Road incluing cleaning etc.complete as per direction of Engineer Rupees Thirty Six And Paise
incharge Eighty Only
Providing & Laying sand & Bitumen filler in joints 10 & 25 mm Rupees Eleven And Paise Fifty
Providing & Fixing Precast RCC Frame with Cover MD 10 Ton ( Rubber Mould Finish ) Inner size 600 x Rupees One Thousand Seven
450 mm with All Necessary Fittings. Hundred Two Only
Providing and fixing to wall celling and floor 10.0 kgf/sqcm working pressure polythelene pipes of the
following outside diameter, low density, complete with special flange compression type fittings, wall clips Rupees Three Hundred Thirty Two
etc. making good wall ceiling and floor (G) 110 mm diameter And Paise Ninety One Only
Drilling and reaming of 400/450mm bore hole in alluvials starta by given 300mm dia pilot bore hole
including assembling lowering hoising casing pipes stainer pipe with gravel packing etc complete. Rupees Eight Hundred Seventy
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium
well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour Rupees Six Hundred Fifty Four
charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. And Paise Twelve Only
pipe size : 150 mm
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium
well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & Rupees Six Hundred Sixty Five
accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. Pipe size : 150 mm And Paise Eighty Five Only
Material charge for the bore inclding labor & materials PVC bore plug/ Cap plug, clamp having lenth of Rupees Two Thousand Eight
274 0.45 mt as per IS for 150 mm dia pipe 1.00 No 2803.62 Hundred Three And Paise Sixty
supplying best qualty of well sorted out "sevalia " gravel of size 4mm to 7mm at site Rupees Two Thousand Twenty
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not
less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross Rupees One Thousand One
276 sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including 1.00 No 1154.40 Hundred Fifty Four And Paise
providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Forty Only
Engineerin-charge.
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S.
Rupees Two Hundred Forty Six
277 class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including 105.00 RMT 246.21
And Paise Twenty One Only
testing of joints complete.(B) 150mm
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S.
Rupees Three Hundred Forty Four
278 class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including 30.00 RMT 344.59
And Paise Fifty Nine Only
testing of joints complete..(C) 250mm
Providing and fixing Single headed internal hydrant having outlet of 63 mm dia(2.1/2”) N.B. hydrant Rupees Six Thousand Eight
279 (IS:5290) (Type-A) landing valve in SS Morris Pattern instanteous coupling type with required hardwares. 26.00 No. 6886.72 Hundred Eighty Six And Paise
Seventy Two Only
Providing & fixing 63mm dia 15 m long RRL hose pipe with 63mm dia male and femal couplings duly Rupees Three Thousand Nine
280 bound with GI wires, revates etc. confirming to IS 636 (typa-A) as required 28.00 No. 3916.23 Hundred Sixteen And Paise Twenty
Stainless steel (grade 304) Three Only
Providing, fixing, testing and commissioning of Weather proof standard fire Hose Cabinet fabricated from
Rupees Five Thousand One
281 18 guage sheet, floor mounting type having Double Opening with M.S. Fabricated Stand, necessary 29.00 No. 5100.00
locking arrangement by allan key. (750x600x250mm)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, confirming
to IS 884 complete with the following as required.
25 mm nominal int. dia. Water hose thermoplastic (Textile reinforced) type-2 as per IS12585 Rupees Seven Thousand Nine
282 25 mm nominal internal dia gun metal globe valve and nozzle. 27.00 No. 7920.84 Hundred Twenty And Paise Eighty
Drum and brackets for fixing the equipment of the wall. Four Only
Connections from risers with 32 mm dia stop gun metal valve & MS pipe and socket.
Providing, fixing and testing of Air Vessel made of 250 mm dia, 8 mm thk sheet, 1200 mm in height with Rupees Sixteen Thousand Two
283 air release valve in top & connection to riser, drain arrangement with 25 mm GM wheel valve with 2.00 No. 16279.35 Hundred Seventy Nine And Paise
required accessories, pressure gauge, painting, etc. compelte Thirty Five Only
Providing and fixing of 63 mm SS branch pipe nozzle conforming to IS 903, suitable for instantaneous Rupees Two Thousand Eight
284 connections to hose coupling etc. as required 27.00 No. 2854.62 Hundred Fifty Four And Paise Sixty
Supplying and fixing specially designed SS 304 orifice plates (minimum 6 mm plate thickness) to be fitted Rupees One Thousand Two
285 between flange and landing valve of external & internal hydrant outlets of hydrant valves for reducing 27.00 No. 1204.79 Hundred Four And Paise Seventy
delivery pressureto 3.5 kg/ sq.cm at hydrant valve Nine Only
Providing, laying, testing and commissioning of the 'C’ class MS Pipe as per IS1239/3589 i/c fittings like
elbows, tees, flanges, tappers, nuts, bolts, gaskets etc. in ground including welding, excavation & Rupees Four Thousand Two
286 providing cement concrete blocks as supports, anti corrosive treatment with 4 mm thick anti corrosive 109.00 Mtr. 4282.61 Hundred Eighty Two And Paise
pipe protection Bituminous tape with black anti corrosive paint as per IS 10221, refilling the trench etc. of Sixty One Only
following sizes complete as required. Size : 150 mm NB
Providing, laying, testing and commissioning of the 'C’ class MS Pipe as per IS1239/3589 i/c fittings like
elbows, tees, flanges, tappers, nuts, bolts, gaskets etc. in ground including welding, excavation & Rupees Three Thousand Four
287 providing cement concrete blocks as supports, anti corrosive treatment with 4 mm thick anti corrosive 89.00 Mtr. 3445.02 Hundred Forty Five And Paise Two
pipe protection Bituminous tape with black anti corrosive paint as per IS 10221, refilling the trench etc. of Only
following sizes complete as required.Size : 100 mm NB
Providing, laying, testing and commissioning of the 'C’ class MS Pipe as per IS1239/3589 i/c fittings like
elbows, tees, flanges, tappers, nuts, bolts, gaskets etc. in ground including welding, excavation & Rupees Two Thousand Eight
288 providing cement concrete blocks as supports, anti corrosive treatment with 4 mm thick anti corrosive 49.50 Mtr. 2854.76 Hundred Fifty Four And Paise
pipe protection Bituminous tape with black anti corrosive paint as per IS 10221, refilling the trench etc. of Seventy Six Only
following sizes complete as required. Size : 80 mm NB
Supplying & fixing single headed external yard hydrant valve with 1 no 63 mm dia instantaneous SS
Rupees Five Thousand Five
coupling and CI wheel, ISI marked, confirming to IS 5290 (Type A) with blank gunmetal /SS cap and
289 2.00 No. 5564.93 Hundred Sixty Four And Paise
chain as required
Ninety Three Only
Single headed stainless steel
Supplying and fixing 4 way Fire Brigade service inlet connection of CI body with gun metal instantanoeus Rupees Twelve Thousand Four
290 male inlet coupling complete with chain & cap as required for suitable MS pipe (150 mm) connection 1.00 No. 12435.20 Hundred Thirty Five And Paise
conforming to IS 904 as required Twenty Only
Supplying and fixing 2 way Fire Brigade service inlet connection of CI body with gun metal instantanoeus
Rupees Six Thousand Ninety Three
291 male inlet coupling complete with chain & cap as required for suitable MS pipe (100 mm )connection 1.00 No. 6093.41
And Paise Forty One Only
conforming to IS 904 as required
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS
1239 including welding, fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc and fixing the
pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic
Rupees Five Thousand Five
enamle paint of required shade complete as required. The work includes makingholes in brick or RCC
292 20.00 Rmt. 5555.02 Hundred Fifty Five And Paise Two
walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction
of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a
coat of approved primer. 200 mm dia (6.3 mm thk )
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS
1239 including welding, fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc and fixing the
pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic
Rupees Three Thousand Six
enamle paint of required shade complete as required. The work includes makingholes in brick or RCC
293 17.00 Rmt. 3606.90 Hundred Six And Paise Ninety
walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction
of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a
coat of approved primer 150mm dia (6.3 mm thk )
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS
1239 including welding, fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc and fixing the
pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic
Rupees Two Thousand Five
enamle paint of required shade complete as required. The work includes makingholes in brick or RCC
294 26.20 Rmt. 2581.50 Hundred Eighty One And Paise
walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction
of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a
coat of approved primer 100mm dia (6.3 mm thk )
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS
1239 including welding, fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc and fixing the
pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic
Rupees One Thousand Nine
enamle paint of required shade complete as required. The work includes makingholes in brick or RCC
295 7.40 Rmt. 1910.39 Hundred Ten And Paise Thirty Nine
walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction
of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a
coat of approved primer 80 mm dia (6.3 mm thk )
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS
1239 including welding, fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc and fixing the
pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic
Rupees One Thousand Six
enamle paint of required shade complete as required. The work includes makingholes in brick or RCC
296 40.00 Rmt. 1640.26 Hundred Forty And Paise Twenty
walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction
of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a
coat of approved primer 65mm dia (6.3 mm thk )
Providing, installing testing & commissioning of SS Y-strainers fabricated out of 1.6 mm thick SS grade Rupees Nineteen Thousand Seven
297 304, sheet with 3 mm dia holes with stainless steel flange 3.00 No. 19777.59 Hundred Seventy Seven And Paise
Size : 200 mm Fifty Nine Only
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with Rupees Thirteen Thousand Six
298 bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 2.00 No. 13633.11 Hundred Thirty Three And Paise
13095 of following sizes as required: 200 mm dia Eleven Only
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with Rupees Eight Thousand One
299 bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 4.00 No. 8170.27 Hundred Seventy And Paise
13095 of following sizes as required: 150mm dia Twenty Seven Only
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with Rupees Six Thousand One
300 bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 3.00 No. 6101.25 Hundred One And Paise Twenty
13095 of following sizes as required: 100mm dia Five Only
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with Rupees Four Thousand Five
301 bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 6.00 No. 4536.15 Hundred Thirty Six And Paise
13095 of following sizes as required: 80mm dia Fifteen Only
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with Rupees Three Thousand Nine
302 bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 2.00 No. 3953.93 Hundred Fifty Three And Paise
13095 of following sizes as required: 65mm dia Ninety Three Only
Providing, installing testing & commissioning of NON RETURN VALVE of following sizes confirming to IS Rupees Fifteen Thousand Eight
303 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 150 mm dia 4.00 No. 15845.08 Hundred Forty Five And Paise
Providing, installing testing & commissioning of NON RETURN VALVE of following sizes confirming to IS Rupees Nine Thousand Nine
304 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 100mm dia 4.00 No. 9945.68 Hundred Forty Five And Paise
Sixty Eight Only
Providing, installing testing & commissioning of NON RETURN VALVE of following sizes confirming to IS Rupees Six Thousand Nine
305 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 80mm dia 4.00 No. 6926.77 Hundred Twenty Six And Paise
Seventy Seven Only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing, installing testing & commissioning of NON RETURN VALVE of following sizes confirming to IS
Rupees Five Thousand Eight
306 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 65 mm dia 1.00 No. 5800.62
Hundred And Paise Sixty Two Only
Providing & fixing of pressure switch in MS pipe line including connection etc. as required. Rupees One Thousand Four
307 4.00 No. 1400.85 Hundred And Paise Eighty Five
150 mm dial Bourdon type Pressure gauge with Syphon tubing, isoltaion valve & mounting accessories Rupees One Thousand Four
complete Range : 0 - 15 kg/sq.cm. Hundred Twelve Only
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS
1239 including welding, fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc and fixing the
pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic
Rupees One Thousand Three
enamle paint of required shade complete as required. The work includes makingholes in brick or RCC
309 164.00 Rmt 1306.57 Hundred Six And Paise Fifty Seven
walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction
of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a
coat of approved primer. 50mm
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS
1239 including welding, fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc and fixing the
pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic
enamle paint of required shade complete as required. The work includes makingholes in brick or RCC Rupees One Thousand Fifty Six
walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction And Paise Sixty Eight Only
of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a
coat of approved primer. 40mm
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS
1239 including welding, fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc and fixing the
pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic
enamle paint of required shade complete as required. The work includes makingholes in brick or RCC Rupees Eight Hundred Seventy
walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction One And Paise Forty Only
of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a
coat of approved primer. 32mm
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS
1239 including welding, fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc and fixing the
pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic
enamle paint of required shade complete as required. The work includes makingholes in brick or RCC Rupees Seven Hundred Seventy
walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction Two And Paise Nineteen Only
of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a
coat of approved primer. 25mm
Providing, fixing, testing and commissioning of 15 mm dia quartzoid bulb type sprinklers of ratings
Rupees Five Hundred Three And
313 degree centigrade with required accessories: 90.00 No. 503.01
Pendent sprinkler
SITC of test & drain assembly with all piping, sight glass, 25mm dia. test & drain valve etc complete Rupees Six Thousand Eight
314 8.00 No. 6869.73 Hundred Sixty Nine And Paise
Seventy Three Only
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with Rupees Three Thousand Four
315 bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 5.00 No. 3452.30 Hundred Fifty Two And Paise
13095 of following sizes as required: 50 mm Thirty Only
Providing and fixing flow switches on MS pipe including connections etc. as required.50mm Rupees Two Thousand Five
316 8.00 No. 2521.38 Hundred Twenty One And Paise
Thirty Eight Only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Getting provisional NOC and Final NOC and Renewal of NOC (During Defect Liability Period) for Fire
Hydrant,Sprinkler system, Fire Extinguisher, Fire alarm system etc. from local fire authority or any other relevant
statutory authority at initial stage and required various other stages of construction work, including preparation of
reports/drawings as per fire authority requirement. Rate also includes renewal of Fire NOC during defectliability
period as per requirement. Main agency has to give demonstration of all fire system to fire officer police /
concern beneficiaries & GSPHCL. Agencyhas to submit FDR of approved bank as per clause 2.0, section 3, of
Rs 20000.00 Or Quoted rate which ever is higher to GSPHCL for minimum maturitperiod of Four yearsin favour
of GSPHC, which will be released after Successful Submitting of All Fire NOC at the completion of defect
liability period.Renewal FireN.O.C. shall be submitted final S.D.proposal.Agency has charges like preparing
and submission of all the documents, Photographs, CD/DVD required to get the N.O.C. from concern fire
department and also liaisoning work with concern departments. Main civil agency has to get the pre-NOC from
fire & emergency department well beforestarting civil & the fire hydrant work including sump & pumproom work.
For that professional & experience fire agency has to prepare drawing of fire hydrant system, sprinkler system, Rupees Sixteen Thousand Nine
fire alarm system, DGset etc. as per tender item and making floor layout of all fire pump panel, cable earthing Hundred Fifty Only
etc in pump room. If any changes required in drawings of sump & pump room. Main agency has to inform in
written before excavation of pump & sump room. Agency has to calculate the total head & discharge required as
per NBC/local fire office requirement and as per sitesituation and submit fire pump OEM specification curve
foundation detail etc & get approval of cable, panel drawings & specification. After completion of fire hydraunt
related work as per pre-NOC, tender specification & drawing approved by fire department, agency has to do site
visit with fire department & give the testing & demonstration to fire officer & get the final NOC before handing
over of the building. Agency has to give live testing & demonstration of all system to GSPHCL & police
department jointly. For fire NOC fee separate item is taken in tender. Agency has to quote the rate as per latest
Gazettein respective tender item.
Supplying and installation of minimum 46 mm thick Fire rated door as per IS 3614-2021 standards made
by galvanized steel conforming to 15 277 Fire door tested at CBR/NABL approved labs for maximum
Rupees Eleven Thousand Seven
rating of 2 hrs tested. Test certificate submitted shall be with in the validity period of 15 years.The frame
318 52.00 SMT 11740.27 Hundred Forty And Paise Twenty
and shutter are finished with powder coating of 60 micron of approved colour with all necessary fittings
(Fire door make approved by GSPHCL)
Providing and Laying of Fire Stop Mortar Seal( Fire Barrier) for Fire Penetration Sealing System in floor
Rupees Fourteen Thousand Eighty
319 openings for vertical shafts & wall opening.The mortar seal shall have minimum 2 hours fire resistance . 21.00 SMT 14088.98
Eight And Paise Ninety Eight Only
(M.S. Duct size 600mm x 600 mm)
Providing Supplying and Fixing S4 Channel System (S4 Channel + Profile Bracket + U Bolt Rubber
mounted System) for multiple Pipes for External Vertical Fixed line with wall distance 3" ncluding nuts, Rupees Four Hundred Twenty One
bolts, fastners etc complete as per detailed Specifications and as directed by Engineer in Charge. And Paise Fifty Eight Only
Providing Supplying and Fixing Single Pipe Bracket System with U Bolt Rubber mounted for Pipe
Supporting Clamping System for External Vertical Fixed line with wall distance 3" including nuts, bolts, Rupees One Hundred Eighty Two
fastners etc complete as per detailed Specifications and as directed by Engineer in Charge. And Paise Eighty Three Only
Drilling of 250 mm dia pilot bore hole in all strata by using mud-flush direct rotary ring by using Bentonite Rupees Five Hundred Ninety Five
Reaming 250 mm dia pilot bore to 450 mm. dia hole including Assembling, Lowering Housing, Casing
Rupees Two Hundred Seventy Five
323 strainer pipe, gravel packing etc.completed. From 200 mm dia to 450 mm dia bore hole. 250.00 Rmt 275.00
Conduction electrologing test of 300 mm dia. Bore hole incl. carting & idle-hour
324 1.00 JOB 18000.00 Rupees Eighteen Thousand Only
(A) Development of each water bearing zones comes/ across upto the full depth of tube well ( size
200/250/300 mm dia. depth more than 186 meter ) by lowuring 100 mm dia drop line & 32 mm dia G.I.
Rupees Twenty Seven Thousand
325 Ariline for each zone with suitable capacity air compressor upto the availability of sand free discharge ( 1.00 JOB 27446.00
Without air comp. charge) Four Hundred Forty Six Only
(B) Development of above mentioned bore by air compressor 900 cfm./ 200 psi. capacity upto 6 hrs Rupees Eight Thousand Four
minimum until sand free discharge of the above which ever is latter. Hundred Fifteen Only
M.S E.R.W plain end medium duty pipe confirming to I.s-4270/2001 with latest amenments in random
Rupees Two Thousand Four
327 length of 4 to 7 mt.as per GWSSB R/C (A)200MM DIA(min 6mm thick)TATA OR JINDAL MAKE 180.00 Rmt 2407.00
Hundred Seven Only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Manufacture, supply and delivery of Cage type trapezoidal shape ("V"') wire wound low carbon,
Rupees One Thousand Six
328 galvanized screen pipe and stainless steel screen pipes, confirming to IS: 8110. 72.00 Rmt 1666.00
Hundred Sixty Six Only
(B)200mm dia grade regular (1) 1.00 mm slot size
Supply of clay ball made from sticky clay of size 15 mm to 25 mm & quality certified by Hydrologist. Rupees Seven Hundred Fifty One
Bore plug having 100mm height made from M.S . Plate with 3 holes at equal distance on circumference
for nut-bolts& lock nuts of std. make complete .from 5 thick m.s plate (for top also) suitable for 200mm Rupees Seven Hundred Seventy
dia pipe. Four And Paise Eighty Two Only
Supply of portland cement Rupees Six Thousand Three
Hundred Two Only
Cement sealing as recommended by Hydrologist ( without cost of cement & by means mud pump ) Rupees Thirteen Thousand Two
Hundred Seventy Three Only
Supplying and filling in foundation and plinth with RUBBLE including filling voids with sand and watering Rupees One Thousand Four
333 etc.complete. 22.00 CMT 1440.63 Hundred Forty And Paise Sixty
Providing & fixing cast iron steps of size 500 x 150 x 22.5 mm & painting with two coats of anticorrosive 36.00 NO 162.23 Rupees One Hundred Sixty Two
paint etc. complete. And Paise Twenty Three Only
335a Providing and erecting Point wiring with 1.1 KV grade ISI marked 2 X 1.5 sq. mm copper PVC insulted 1630.00 Point 481.00 RS: Four Hundred Eighty One
FRLS wire with 1.5 sq. mm (green) copper PVC insulated FRLS wire for earth continuity in FIA approved only
ISI mark medium class white colour 20/25 mm dia. embossed rigid PVC pipe with PVC fitting fixed with
adhesive solution erected on/in Brick Wall / slab along with continuous G.I. fish wire to draw wires and
laid in approved manner zari for PVC pipe and boxes shall be filled with cement mortar and finishing the
surface to match the wall / ceiling complete with approved make 5/6 Amp. ISI make modular type switch
and accessories mounted in 20 G. G.I. company fabricated metallic box covered with appropriate front
plate modules erected flushed with wall / ceiling with necessary modular lamp holder / modular ceiling
rose / HD Connector (make & model approved by EIC and matching colur with switches accessories)
(Deep Junction box 75mm depth if required) as directed for concealed wiring. Light point. Cat.-III.
Necessary sheet / tape / polythene / sand must be erected or filled in all box to prevent mortar going into
the box. Length of point wiring must not increase than 10 mtr. For that necessary switch boards and their
locations must be finalised before execution by agency otherwise payment will not be done for extra long
point. (For future extention, if required, agency has to erect one higher size metal box and modular plate
as per instruction of EIC. Cost of blank plate shall be paid as per tender item) [This item include cleaning
(inside/outside) of all G.I. switch boards, electric point box, fan box, MCBDB & box cutting plaster
finishing for modular plate without any gap] [conductor resistance should be as per IS:8130/1984]
335b For Two Way Controlled Light Point, Cat.-III 200.00 Point 598.00 RS: Five Hundred Ninty Eight
335c For Secondary Light Point Cat.-III 130.00 Point 166.00 RS: One Hundred Sixty Six
335e For Fan Point.(with 6A Modular type switch and Two Module hum free 5/6 step EME step type Electronic 330.00 Point 668.00 RS: Six Hundred Sixty Eight
fan regulator both having ISI Make ) Cat-III only
335f For Two way controlled Fan point (with 6A Modular type switch and Two Module hum free 5/6 step EME 20.00 Point 785.00 RS: Seven Hundred Eighty Five
step type Electronic fan regulator both having ISI Make ) Cat-III only
335g For separate Point (with 6 Amp. Switch & 3/5 pin socket both having ISI mark) Cat. III 340.00 Point 505.00 RS: Five Hundred Five only
335h For Looped on switch board (with 6 Amp. Switch & 3/5 pin socket both having ISI mark) Cat. III 760.00 Point 255.00 RS: Two Hundred Fifty Five
336 Providing and erecting modular type accessories mounted on 20G G.I. company fabricated galvanised 80.00 Each 788.00 RS: Seven Hundred Eighty
metal box covered with approriate front plate modules erected flushed with wall/Ceiling with 1 Nos. TV Eight only
Socket,1 Nos. of 16 Amp SP Switch & 3 Nos. of 6 Amp 3/5 pin plug. [For TV Switch board] Cat III
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
337 Providing and fixing Plug Point wiring with 1.1 KV grade ISI marked approved make 2 x 2.5 sq.mm 120.00 Point 738.00 RS: Seven Hundred Thirty Eight
copper PVC insulated FRLS wire with 1.5 sq.mm (green) copper PVC insulated FRLS wire for earth only
continuity in FIA approved ISI mark white colour medium class 20/25 mm dia. embossed rigid PVC
pipe with PVC fitting fixed with adhesive solution erected in wall/slab along with continuous G. I. fish wire
to draw wires and laid in approved manner zari for PVC pipe & boxes shall be filled with cement mortar
& finishing the surface to match the wall / ceiling complete with 16 Amp Modular type Swich and
accessories mounted in 20 G. GI company fabricated metallic box covered with appropriate front plate
modules erected flushed with wall. (a) 16 Amp. Indicator switch & 1 No. 6/16 A universal socket white
colour suitable for 3/5 pin top duly both having ISI mark. (Necessary sheet / tape / polythene / sand must
be erected or filled in all box To Prevent Mortor Going In To The Box) Cat.-III. (Conductor resistance
should be as per IS:8130/1984)
338 Providing & Erecting Plug Point wiring with approved ISI marked 1.1 kv grade 2 x 4.0 sq.mm copper PVC 160.00 Point 863.00 RS: Eight Hundred Sixty Three
insulated FRLS wire with 2.5 sq.mm (green) copper PVC insulated FRLS wire for earth continuity in FIA only
approved ISI mark white colour medium class 25 mm dia. embossed rigid PVC pipe with PVC fitting
fixed with adhesive solution erected in wall / slab along with continuous G.I. fish wire to draw wires and
laid in approved manner. zari for PVC pipe & boxes shall be filled with cement mortar & finishing the
surface to match the wall / ceiling complete with approved make 20 Amp. Modular type indicator switch
and accessories mounted in 20 SWG GI company fabricated metallic box covered with appropriate front
plate modules erected flushed with wall / ceiling. (a) 20 Amp Indicator switch & 1 No. 20 A universal
socket white colour suitable for 3 pin top duly both having ISI mark (A.C POINT ONLY) CAT III
(Necessary sheet / tape / polythene / sand must be erected or filled in all box to Prevent Mortor Going In
339 Providing and fixing Plug Point wiring with approved ISI marked 1.1 kv 2 x 4.0 sq.mm copper PVC 80.00 Point 991.00 RS: Nine Hundred Ninty One
insulated FRLS wire with 2.5 sq.mm (green) copper PVC insulated FRLS wire for earth continuity in FIA only
approved ISI mark white colour medium class 20/25 mm dia. embossed rigid PVC pipe with PVC fitting
fixed with adhesive solution erected in wall/slab along with continuous G.I. fish wire to draw wires and
laid in approved manner. zari for PVC pipe & boxes shall be filled with cement mortar & finishing the
surface to match the wall / ceiling complete with 1 No. 25 Amp. Modular type Single pole MCB Swich and
1 no. 25 Amp. universal 3/5 pin socket suitable for 3/5 pin top duty. [Both Having ISI mark must] mounted
in 20 G. G.I. company fabricated metallic box covered with appropriate front plate modules erected
flushed with wall. Above accessories will be erected combined or separately as per site requirement and
instruction of EIC. (Necessary Sheet Must Be Erected On All Box To Prevent Mortar Going Into The
Box) (Conductor resistance should be as per IS:8130/1984) (Geyser point) Cat.-III. (Conductor resistance
should be as per IS:8130/1984)
340a Providing following type of Modular Type Accessories mounted with 20 G company fabricated metalic 600.00 Each 25.00 RS: Twenty Five only
box, single mounting base frame covered with textured / metallic front plate, modules erected with
necessary connection. As desired by Engineer in charge. Blank Plate Single Cat.-III
340b Footlight as pre colour requirement with concealed box,modular accessories,acrylic glass cover with 40.00 Each 490.00 RS: Four Hundred Ninty
suitable LED 2-9 watt with all accessories as per following module (B) FOUR MODULES CAT-III only
341a Providing and laying Mains with FRLS PVC Insulated wire ISI marked 1.1 KV grade with FIA approved 3000.00 Mtr. 62.00 RS: Sixty Two only
ISI mark medium class 20/25/32 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive
solution to be erected on/in brick wall / slab along with continuous G. I. fish wire to draw mains laid in
approved manner with plastering by cement mortar & finishing the surface to match the wall / ceiling
complete with FRLS PVC insulated wire for earth continuity. (Approved ISI make only) [a] 2 x 1.5 sq.mm.
FRLS copper multi stranded conductor mains with 1.5 sq.mm. FRLS copper multi stranded conductor
for earthing as per standard colour code. [conductor resistance should be as per IS:8130/1984]
341b 2 x 2.5 sq.mm. FRLS copper multi stranded conductor mains with 1.5 sq.mm. FRLS copper multi 1200.00 Mtr. 82.00 RS: Eighty Two only
stranded conductor for earthing as per standard colour code. (Conductor resistance should be as per
341c 2 x 4.0 sq.mm. FRLS copper multi stranded conductor mains with 2.5 sq.mm. FRLS copper multi 1600.00 Mtr. 111.00 RS: One Hundred Eleven
stranded conductor for earthing as per standard colour code. [conductor resistance should be as per only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
341d 4 x 10.0 sq.mm. FRLS copper multi stranded conductor mains with 4.0 sq.mm. FRLS copper multi 1200.00 Mtr. 421.00 RS: Four Hundred Twenty One
stranded conductor for earthing as per standard colour code. [Main panel to 3 Phase MCBDB] only
(Conductor resistance should be as per IS:8130/1984)
342a Providing and erecting Medium Class FIA approved and ISI mark white colour (embossed) RIGID PVC 800.00 Mtr. 24.00 RS: Twenty Four only
PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with
adhesive solution & clamps on / in wall / ceiling along with continuous fish wire to draw mains with
necessary fittings and junction boxes for following dia. (a) 20 mm. dia.
342b For 25 mm. dia. 5000.00 Mtr. 33.00 RS: Thirty Three only
342c For 32 mm. dia. 300.00 Mtr. 54.00 RS: Fifty Four only
343 Providing & erecting following size of TV Co-axial flexible cable comprising inner conductor of solid bare 2600.00 Mtr. 39.00 RS: Thirty Nine only
copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids
@ suitable coverage overall sheathed with black PVC insulation.[b] RG-6 [Polycab/ Finolex / RR Kabel
344 Providing & fixing 20 mm. dia. PVC insulated G.I. Corrugated Flexible pipe with necessary socket, PVC 50.00 Mtr. 31.00 RS: Thirty One only
bushes saddle, Check-nuts etc. complete of following sizes.
345 Providing & fixing 25 mm. dia. PVC insulated G.I. Corrugated Flexible pipe with necessary socket, PVC 50.00 Mtr. 37.00 RS: Thirty Seven only
bushes saddle, Check-nuts etc. complete of following sizes.
346 Supplying and erecting M.S./G.I. metal box having 16 Gauge painted with red oxide be concealed in wall 14000.00 Sq. Inch 5.94 RS: Five and Paise Ninty
with necessary plastering & finishing with 3 mm thick laminated sheet with grooving as directed of Four only
following depth 3" depth.
347 carry out RCC Core cutting- up to 100 mm dia./200mm thick Wall/beam/slab with providing PVC pipe of 100.00 job 1188.00 RS: One Thousand One Hundred
3 mm thick inside and necessary finishing on both ends of wall . Eighty Eight only
348 carry out RCC Core cutting- up to 100 mm dia./300mm thick Wall/beam/slab with providing PVC pipe of 40.00 job 1534.00 RS: One Thousand Five Hundred
3 mm thick inside and necessary finishing on both ends of wall . Thirty Four only
349 Supply, Installation, Testing and Commissioning of suitable sweep, BEE 5 Star rated, Ceiling fan with 290.00 Each 2603.00 RS: Two Thousand Six Hundred
Brush Less Direct Current (BLDC) permanent ferrite magnet Motor, class of insulation: B, Rust free 3 Three only
nos.Aluminium blades, 2 nos. canopies, shackle kit with earthing provision, copper winding, Power
factor not < 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM,230v
(tolerance as per IS : 374-2019), THD < 10%, compitible with electronic regulator unit for Speed Control
and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C
(Max.), suitable for 140 to 285 Voltage and rectifier circuit with surge, over current and overload
protection , 50 Hz, Single phase AC Supply, earthing etc. Complete as required.[ Make shall be approved
by Engineer in Charge] (A) 1200 mm Sweep (48")(model & make approved by engineer in charge
subject to above specifications)
350 Supply, Installation, Testing and Commissioning of suitable sweep, BEE 5 Star rated, Ceiling fan with 40.00 Each 3323.00 RS: Three Thousand Three
Brush Less Direct Current (BLDC) permanent ferrite magnet Motor, class of insulation: B, Rust free 3 Hundred Twenty Three only
nos.Aluminium blades, 2 nos. canopies, shackle kit with earthing provision, copper winding, Power
factor not < 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM,230v
(tolerance as per IS : 374-2019), THD < 10%, compitible with electronic regulator unit for Speed Control
and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C
(Max.), suitable for 140 to 285 Voltage and rectifier circuit with surge, over current and overload
protection , 50 Hz, Single phase AC Supply, earthing etc. Complete as required.[ Make shall be approved
by Engineer in Charge] (A) 1400 mm Sweep (56")(model & make approved by engineer in charge
subject to above specifications)
351 Providing, erecting, testing Ceiling Fan confirming to IS: 374/1979 AMDT No. 1 to 6 Class-I, 50 Hz. 20.00 Each 1929.00 RS: One Thousand Nine Hundred
Specification of Ceiling Fan must be as per below. (1) Sweep: 1200 mm, (2) Operating Voltage: 180 to Twenty Nine only
230 V, (3) Power Factor: > 0.9, (4) Power Consumption: maximum 53W, (5) RPM: minimum 330, (6)
Service value:min 4.3 m3/min. (7) Class of insulation: 'B', (8) No. of heavy duty premium quality Ball
bearing: Two, (9) Total Body: Top & Bottom should be alluminium, (10) Blade: Aluminium approx 1.1 mm
thick, (11) Colour: White high grade powder coating, (12) Canopy: Two Nos. Heavy duty, (13)
Condenser: min 1.5 MFD (15% Tolerance )as per is 1709-1984, Aluminium body premium quality,
Branded make,(14) Down road: up to 1.0 mtr as per site requirment, (15) Required fixing accessories,
(16) 3 core 0.75 sq.mm ISI wire as per site requirment, (17) No vibration and noise due to mechanical
parts. (Agency has to erect safey wire with ceiling fan and checked with EIC) (OEM has to approved
model as per tender specification and tested at ERDA) (Necessary test reports should be submitted
strictly at the time of approval. Sample approved by EIC subject to above specification only)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
352 Supplying & Erecting Fan Hook Of 10 mm M.S Round bar bounded to the RCC bars up to 50 mm Length 350.00 Each 125.00 RS: One Hundred Twenty Five
each side & piereced through 18 Gauge G.I Box having 125 mm dia depth of 75 mm complete erected only
concealed in ceiling with necessary modular plate / sheet
353 Supplying & erecting approved make low noise Decorative exhaust fan having size 150/200 mm with 110.00 Each 1687.00 RS: One Thousand Six Hundred
1350 RPM with round / square frame ABS/metalic body with Grill / inbuilt lowers.(Make & model Eighty Seven only
approved by EIC)
354 Supplying and erecting approved make Cabin fan of 230V. A.C. 50 Cy/s. 400 mm. sweep oscillating type 4.00 Each 1527.00 RS: One Thousand Five Hundred
complete erected with lead wires as directed.Cat-III Twenty Seven only
355 Supplying and erecting approved make oscillating type bracket fan A.C. 230 V. 50 Hz, 400/450 mm 40.00 Each 2509.00 RS: Two Thousand Five Hundred
sweep wall mounted with height adjustment and rotary tilting device complete with guard, flexible Core Nine only
plug top complete erected with lead wires as directed. (Crompton Make High Flow model)
356 SITC Of Max 24 Watt LED Indoor Commercial make high efficiency performance Tube rod Approx. 4 20.00 Each 370.00 RS: Three Hundred Seventy
feet (lamp) with combination of high quality diffused polycarbonate and alluminium base dedicated heat only
sink for better perfomance of LED and also long life.High quality LED must be placed on metal core
printed circuit board for better heat dissipation. seprate driver with all protection like under voltage (160V
to 270V), over voltage protection 2 KV surge protection.The life of lamp should have 25,000 hrs at L70
,THD<15% efficiency >=100lm/w, with high power factor > 0.90 , with CRI > 80 , for better color rendition
total lumens should be min 2400. The lamp should be suitable for T8 box type fitting made form CRCA
sheet and white powder coated.The data sheet of LM79 for complete lamp can also be provided (Note:-
The manufacturer/ authorised Channel partner of the manufacturer has to submit 5 yr free replcement
Guarantee for complete Fixture ) (Approval will be given strictly subject to item specification).
357 SITC of Indoor Commercial recess/surface mounted (IP20) Max. 12 w Cool/warm white Color LED 10.00 Each 423.00 RS: Four Hundred Twenty Three
Down lighter office Lighting Luminaire with external separate driver having BIS certification with fully die only
cast aluminium alloy housing without any PVC/Plastic part with corrosion resistant powder coated finish
as a heat sink with Poly Carbonet diffuser LED complete (only from Philips Lumileds, CREE, BridgLux,
Seoul, Nichia & Osram CRI > 80, CCT 5600K (5400 to 5800K bin). The led's should be mounted on
Metal core based PCB for better heat conduction and long life of LED. (LM 79 for complete fixture, LM80
for individual LED Report mustbe submitted) The fixture should have extra protection of driver like
over/under voltage, THD<15%, P.F.>0.90, for 12 w fixture wide voltage range from 100 to 270 V, 50/60
HZ, 4 KV surge protection.Fixure must have Min. 1620 Lumens light output. Fixture Efficacy should
be>=90 Lumens/watt. (L70 @ 30,000 Hrs) The Fixture should be able to easily mount on POP/Grid False
cieling. The Luminiare should be tested as per IP20 standards and following test reports should be
submittedat the time of approval. Model Approved By EIC as per Specification only (Note:- The
manufacturer/authorized Channel partner/dealer of the manufacturer has to give a 5 yrs. free replcement
Guarantee for complete Fixture)
358 SITC of Indoor Commercial recess/surface mounted (IP20) Max. 18 w Cool/warm white Color LED 140.00 Each 584.00 RS: Five Hundred Eighty Four
Down lighter office Lighting Luminaire with external separate driver having BIS certification with fully die only
cast aluminium alloy housing without any PVC/Plastic part with corrosion resistant powder coated finish
as a heat sink with Poly Carbonet diffuser LED complete (only from Philips Lumileds, CREE, BridgLux,
Seoul, Nichia & Osram CRI > 80, CCT 5600K (5400 to 5800K bin). The led's should be mounted on
Metal core based PCB for better heat conduction and long life of LED. (LM 79 for complete fixture, LM80
for individual LED Report mustbe submitted) The fixture should have extra protection of driver like
over/under voltage, THD<15%, P.F.>0.90, for 18 w fixture wide voltage range from 100 to 270 V, 50/60
HZ, 4 KV surge protection. Fixure must have Min. 1620 Lumens light output. Fixture Efficacy should
be>=90 Lumens/watt. (L70 @ 30,000 Hrs) The Fixture should be able to easily mount on POP/Grid False
cieling. The Luminiare should be tested as per IP20 standards and following test reports should be
submittedat the time of approval. Model Approved By EIC as per Specification only (Note:- The
manufacturer/authorized Channel partner/dealer of the manufacturer has to give a 5 yrs. free replcement
Guarantee for complete Fixture)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
359 SITC of Indoor Commercial recess/surface mounted (IP20) Max. 24 w Cool/warm white Color LED 980.00 Each 751.00 RS: Seven Hundred Fifty One
Down lighter office Lighting Luminaire with external separate driver having BIS certification with fully die only
cast aluminium alloy housing without any PVC/Plastic part with corrosion resistant powder coated finish
as a heat sink with Poly Carbonet diffuser LED complete (only from Philips Lumileds, CREE, BridgLux,
Seoul, Nichia & Osram CRI > 80, CCT 5600K (5400 to 5800K bin). The led's should be mounted on
Metal core based PCB for better heat conduction and long life of LED. (LM 79 for complete fixture, LM80
for individual LED Report mustbe submitted) The fixture should have extra protection of driver like
over/under voltage, THD<15%, P.F.>0.90, for 18 w fixture wide voltage range from 100 to 270 V, 50/60
HZ, 4 KV surge protection. Fixure must have Min. 2160 Lumens light output. Fixture Efficacy should
be>=90 Lumens/watt. (L70 @ 30,000 Hrs) The Fixture should be able to easily mount on POP/Grid False
cieling. The Luminiare should be tested as per IP20 standards and following test reports should be
submittedat the time of approval. Model Approved By EIC as per Specification only (Note:- The
manufacturer/authorized Channel partner/dealer of the manufacturer has to give a 5 yrs. free replcement
Guarantee for complete Fixture)
360 SITC of Indoor Commercial recess/surface mounted (IP20) Max. 9 w Cool/warm white Color LED Down 100.00 Each 218.00 RS: Two Hundred Eighteen
lighter office Lighting Luminaire with external separate driver having BIS certification with fully die cast only
aluminium alloy housing without any PVC/Plastic part with corrosion resistant powder coated finish as a
heat sink with Poly Carbonet diffuser LED complete (only from Philips Lumileds, CREE, BridgLux, Seoul,
Nichia & Osram CRI > 80, CCT 5600K (5400 to 5800K bin). The led's should be mounted on Metal core
based PCB for better heat conduction and long life of LED. (LM 79 for complete fixture, LM80 for
individual LED Report mustbe submitted) The fixture should have extra protection of driver like
over/under voltage, THD<15%, P.F.>0.90, for 9 w fixture wide voltage range from 100 to 270 V, 50/60
HZ, 4 KV surge protection. Fixure must have Min. 810 Lumens light output. Fixture Efficacy should
be>=90 Lumens/watt. (L70 @ 30,000 Hrs) The Fixture should be able to easily mount on POP/Grid False
cieling. The Luminiare should be tested as per IP20 standards and following test reports should be
submittedat the time of approval. Model Approved By EIC as per Specification only (Note:- The
manufacturer/authorized Channel partner/dealer of the manufacturer has to give a 5 yrs. free replcement
Guarantee for complete Fixture)
361 Supplying and erecting 3 W LED lamps with following wattage capacity of 220 to 240 voltage, minimum 20.00 Each 69.00 RS: Sixty Nine only
15000 burning hours life, 500 V in built-surge protection,Polycarbonate diffuser, mounting suitable for
E14 / E27 / B22 lamp holders, pf >= 0.5 (A) LED Lamps integral type, with PC diffuser suitable LAMP
362 Supplying and erecting 8 W LED lamps with following wattage capacity of 220 to 240 voltage, minimum 100.00 Each 111.00 RS: One Hundred Eleven
15000 burning hours life, 500 V in built-surge protection,Polycarbonate diffuser, mounting suitable for only
E14 / E27 / B22 lamp holders, pf >= 0.5 (A) LED Lamps integral type, with PC diffuser suitable LAMP
363 Providing and erecting max. 10 W LED battern having main housing aluminium extruded and front cover 110.00 Each 309.00 RS: Three Hundred Nine
of polycarbonate. Electrically and photomatry parameters are as under:240 V, 50 Hz. System only
wattage.:10W+10%, PF>=0.95, system lumens min. 1000, CCT- 3000K to 6500K, CRI>=80,
THD<=15%, Delivery efficiency>=85%, LM 80 certified LED, 30000 Hrs@ L70, Electronic CC driver,
insulated copper wire, for internal wiring, IP20 Operating voltage:160 to 270 V, Surge-2 KV, length of this
fitting should be 2ft.
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges
shown.) Tube Light with integral driver 8 Watts, Surge-2 KV, IP-20, conventional 2 feet
364 Providing and erecting Polycarbonate body surface mounting LED Bulk head type 9 watt Lighting Fitting 20.00 Each 780.00 RS: Seven Hundred Eighty
with electronic driver having THD < 15%, CRI>80, P.F.0.95 And lumen output from luminaire 720 lm, only
input voltage range 160-270 V AC, 50 Hz cool white (3000 to 6500 k), inbuilt driver having efficiency
>=80lm/w, -20 deg C to + 60 deg C working temperature, AL frame with Beam Angle 120 deg.
365 Supply & fixing decorative Hanging light with/without glass having cylindrical or square shape having 120.00 Each 1891.00 RS: One Thousand Eight
length not less than 10" & width not less 3.5" with holder, lead wire as per required length & base plate Hundred Ninty One only
for fixing the fitting with ceiling with 8 to 10 W led lamp
(lamp shall be natural white )
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
366 Supply & fixing decorative Hanging light with/without glass having cylindrical or square shape having 40.00 Each 2180.00 RS: Two Thousand One Hundred
length not less than 10" & width not less 3.5" with holder, lead wire as per required length & base plate Eighty only
for fixing the fitting with ceiling with 21 to 30 W led lamp
(lamp shall be natural white )
367 Providing and erecting decorative wall bracket fittings complete with LED lamp and rust free fittings 85.00 Each 1696.00 RS: One Thousand Six Hundred
components mounted in chrome finish housing with holder ,clear/opaque glass diffuser complete erected Ninty Six only
with lead wires with minimum 15 wattage capacity as per instruction engineer incharge/architect/authority
368 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on 320.00 Each 2358.00 RS: Two Thousand Three
single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: Hundred Fifty Eight only
513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company mark/name 160V to 270V, Power Factor more than
0.95, THD < 15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt, LED driver efficiency >
85% (fitting required LM-79 & LM-80 Certificates. Circular shaped Surface/Recessed Mount 12W surface
cylinder light. (Natural / warm White)
369 Supplying and erecting LED outdoor fittings with LEDs of wattage 3 Watt & above assembled on 20.00 Each 1401.00 RS: One Thousand Four Hundred
MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: One only
513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name 160V to 270V,Power Factor more
than 0.95, THD < 15 %,CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED driver efficiency
> 85 % ( fitting required LM-79 & LM-80 Certificates. Circular shaped Surface/Recessed Mount 12W
(3W*4 Way) surface cylinder light. (Natural White)
370 Providing and erecting Decorative Ding Dong call bell Stereo type 250 Volt complete erected on existing 20.00 Each 170.00 RS: One Hundred Seventy
polished wooden block or in M.S. box with 3 mm thick white ISI mark laminated sheet. (Anchor (chime), only
Vision, Rider make)
371 Supplying & erecting Electronic Type Cordless Call Bell erected on PVC/Metal board having portable bell 20.00 Each 248.00 RS: Two Hundred Forty Eight
push working on D.C. & bell on 230V A.C. supply with cells / battery only
372a Supplying and erecting approved make GRP Perforated type Cable Tray with required GRP Straight 120.00 Rmt. 526.00 RS: Five Hundred Twenty Six
Coupler Plates , Corner etc. Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized only
Resin System - Manufactured from Pultruded Sections- Polyester Resin System, Glass Content : 55 –
% - - Standard Length : 3000mm- Support Span – 1500mm, Deflection L/200 - Specification NEMA
FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability -
Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame
Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 –
Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard
ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength
– 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65. For Width - 300mm,
Pultruded “C” Channel with 50mm Sides 4mm Thickness, Loading 30 Kg./Mtr. (
Sumip,coromandak,Eircon,satyam-composite Make or equivalent make app by engineer in charge
subject to above specification)
372b For Width - 150 mm, Pultruded “C” Channel with 30mm Sides 3 mm Thickness, Loading 15 Kg./Mtr. 110.00 Rmt. 230.00 RS: Two Hundred Thirty
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
373a Supplying and erecting approved make FRP/GRP Ladder type Cable Tray Material – Corrosion 100.00 Rmt. 493.00 RS: Four Hundred Ninty Three
Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded only
Sections - Polyester Resin System, Glass Content : 55 – 60 % - Thickness- Rung Sq. Hollow Tube
25mm x 25mm - Fixing of Rung to Side Rail with Thermoplastic Pin & Epoxy Adhesive, Assembly Single
Stroke 3 Mtr. Length- Rung Spacing – 300mm - Length of Tray: 3000mm- Support Span – 2500mm,
Deflection L/200 or < 10mm whichever is less - Specification Followed NEMA FG1 1993- UV Resistant -
Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Oxygen Index – Minimum 30%
Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 –
8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per
Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive
Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 –
(A) Width 150 mm, Side Member “C” Section : 75 x 25 x 25mm with 4mm Thickness, Loading 30Kg./Mtr.
With Concentrated Load 70Kg. at center of the span
( Sumip,coromandak,Eircon,satyam-composite Make or equivalent make app by engineer in charge
subject to above specification)
373b For Width 300 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 20.00 Rmt. 636.00 RS: Six Hundred Thirty Six
60Kg./Mtr. With Concentrated Load 70Kg. at center of the span only
374 Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray should 20.00 Rmt. 306.00 RS: Three Hundred Six only
be bended as per IS 2062/1079 shall be fabricated of double bended channel section longitudinal
members with single bended Channel section. Rungs of members welded to the base of the longitudinal
members at 250 mm c/c spacing . as per IS and shall be coated with hot dip galvanizing as per IS
2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on
existing support as per Specification and as per instruction of engineer in charge..for 300 X 50 X 2.0 mm
375 Providing, erecting, fabricating the M.S. structure as per requirement of site as per structure design 2000.00 kg 74.92 RS: Seventy Four and Paise
Including proper size approved by EIC of M.S. angles, flats, bars, square pipe, channels, sections Ninty Two only
(Tata,Zindal,Asian,Jsi Make) complete with cutting, welding, grinding and finishing duly painted with
Asian/Nerolac make premium quality oil paint and true care red oxide metal primer,asian paint make with
erection on site as per direction of engineer in charge with necessary grouting cementing, plastering and
finishing complete. All hole opening of square pipe end must be closed with M.S plate welding. Payment
will be done on KG as per Actual weight.
376 Supplying & erecting 12 mm thick backelite sheet of approved make and grade on 25 x 25 x 3 mm red 6.00 Sq. Mtr. 2289.00 RS: Two Thousand Two Hundred
oxide painted angle iron frame suitable for fixing ICDP SWITCH and energy meter (contractor shall Eighty Nine only
make approved drawing of Bakelite sheet To arrange required No. of Energy meter & ICDP switch -
busbar etc. as per Actual space available in electrical room at site)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
377 Providing ad erecting approved make Three phase Double Door Horizontal / Vertical type (as per site 1.00 Each 4054.80 RS: Four Thousand Fifty Four
requirement and EIC instruction) outgoing per phase outgoing type (PPI) metal clad D.B.as per relevant and Paise Eighty only
indian standards ammended upto date. Supplying and fixing following way single phase MCB
distrubution board of company fabricated with sheet box with powder coated inside and outside after
apply seven tank chemical process of MS sheet cover complete with suitable integral single piece
construction tinned copper busbar and link with all necessary interconnection and with necessary size
MS frame for mounting MCBDB. Manufacturer must be provided (1) IP 43 and as per IS:8623-1 & 3, IEC
61439-1 & 3 having D type PU gasket. (2) Seven tank Powder coating Certificate (3) Tinned
Copper/Brass make neutral & Earthing link with isolation & Protecting Cover for 440 Volts on surface /
recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, with
suitable size FRLS PVC insulated copper conductor up to terminal blocks and internal connection, tinned
coppper bus bar, 4 nos. tinned copper neutral link, 4 nos. tinned copper earth bar, din bar-4 nos.,
detachable gland plate, interconnections, powder painted including earthing etc. (The DBs should be
used of same company of MCB / ELCB to be used) (MCBDB must be erected in line & level with spirit
level and finish the external edge with box cutting plaster) (Same colour MCB(SP/DP) should be used as
same as MCBDB) [Including Necessary numbering / marking on box done with red colour radium sticker
as per site requirement and instructions given by EIC on site. Font / number size given by EIC on site as
per requirement]
(A) Three phase incoming and single phase out going (A) Three phase 8 Way double door PPI cat-III.
378 Providing ad erecting approved make Three phase Double Door Horizontal / Vertical type (as per site 25.00 Each 4603.20 RS: Four Thousand Six Hundred
requirement and EIC instruction) outgoing per phase outgoing type (PPI) metal clad D.B. as per relevant Three and Paise Twenty only
indian standards ammended upto date. Supplying and fixing following way single phase MCB
distrubution board of company fabricated with sheet box with powder coated inside and outside after
apply seven tank chemical process of MS sheet cover complete with suitable integral single piece
construction tinned copper busbar and link with all necessary interconnection and with necessary size
MS frame for mounting MCBDB. Manufacturer must be provided (1) IP 43 and as per IS:8623-1 & 3, IEC
61439-1 & 3 having D type PU gasket..(2) Seven tank Powder coating Certificate (3) Tinned
Copper/Brass make neutral & Earthing link with isolation & Protecting Cover for 440 Volts on surface /
recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, with
suitable size FRLS PVC insulated copper conductor up to terminal blocks and internal connection, tinned
coppper bus bar, 4 nos. tinned copper neutral link, 4 nos. tinned copper earth bar, din bar-4 nos.,
detachable gland plate, interconnections, powder painted including earthing etc. (The DBs should be
used of same company of MCB / ELCB to be used) (MCBDB must be erected in line & level with spirit
level and finish the external edge with box cutting plaster) (Same colour MCB(SP/DP) should be used as
same as MCBDB) [Including Necessary numbering / marking on box done with red colour radium sticker
as per site requirement and instructions given by EIC on site. Font / number size given by EIC on site as
per requirement] For Three phase incoming and single phase out going (A) Three phase 12 Way double
door PPI cat-III.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
379 Providing ad erecting approved make single phase Double Door metal clad D.B. as per relevant indian standards 3.00 Each 5868.00 RS: Five Thousand Eight
ammended upto date. Supplying and fixing following way single phase MCB distrubution board of company fabricated Hundred Sixty Eight only
with sheet box with powder coated inside and outside after apply seven tank chemical process of MS sheet cover
complete with suitable integral single piece construction tinned copper busbar and link with all necessary
interconnection and with necessary size MS frame for mounting MCBDB. Manufacturer must be provided (1) IP 43 and
as per IS:8623-1 & 3, IEC 61439-1 & 3 having D type PU gasket. (2) Seven tank Powder coating Certificate (3) Tinned
Copper/Brass make neutral & Earthing link with isolation & Protecting Cover for 240 Volts on surface / recess complete
with loose wire box, terminal connectors for all incoming and outgoing circuits, with suitable size FRLS PVC insulated
copper conductor up to terminal blocks and internal connection, tinned coppper bus bar, 1 no. tinned copper neutral link,
tinned copper earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc.
Single phase incoming and horizontal single phase outgoing. For 16 Way MCBDB: Including 40 Amp. 30 mA double
pole ELCB (ELCB confirming to IS:12640/1988 having sensitivity of 30 mA and breaking capacity of 10 KA), MCB
Amp. double pole switch (C curve confirms to IS:8828 having breaking capacity of 10 KA) and S.P. MCB of rating 6 to
Amp. with NL suitable to operate on 240 Volt A.C. power. (6 Amp:- 4 Nos., 16 Amp:- 4 Nos. & 25 Amp: 4 Nos.) Cat.-III
(The DBs should be used of same company of MCB / ELCB to be used) (MCBDB must be erected in line & level with
spirit level and finish the external edge with box cutting plaster) (Same colour MCB(SP/DP) should be used as same as
MCBDB) [Including Necessary numbering / marking on box done with red colour radium sticker as per site requirement
and instructions given by EIC on site. Font / number size given by EIC on site as per requirement] (The DBs should be
used of same company of MCB / ELCB to be used) (MCBDB must be erected in line & level with spirit level and finish
the external edge with box cutting plaster) (Same colour MCB(SP/DP) should be used as same as MCBDB) [Including
Necessary numbering / marking on box done with red colour radium sticker as per site requirement and instructions
given by EIC on site. Font / number size given by EIC on site as per requirement]
380 Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board 15.00 Sq. Mtr. 16230.00 RS: Sixteen Thousand Two
having IP-42 & above protection as per approval from engineer incharge and made from 2 mm. thick CRC M.S. sheet for Hundred Thirty only
outer body & doors, 1.6 mm. thick CRC M.S. sheet for internal partitions with necessary supporting angles, flats
including skirting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements &
instruction of engineer-In-Charge with erection of supplied switchgears, busbars with suitable size of interconnecting
PVC copper wire / Copper-Aluminium strips, rubber gromets, rib, control wires, backelite control fuses, measuring
instruments, earth bus & earth bolts, foundation flange-bolts-base plates, sufficient nos. of hinged doors, handle with
locking arrangement, rubber gasket complete with Required Nos. heavy Duty Connector with Cadmium plated nut and
bolt for Anti rusting The panel shall be supplied with Seven Tank chemical process which shall be carried out before
applying painting, painted with powder coating. (The rates excludes the cost of switchgears, busbars, interconnecting
mains & Copper / Aluminium strip, fuse, meters etc. The dimension shall be measured excluding base beams) The
standard companies switch gear shall be used and only manufacturers at CPRI approved factory as per IEC 61439 and
shall be certified by that company whose switch gears are used after fabrication for beneficial use. With 350 mm depth
Panel manufacturer have to give 5 years maintenance and service support if in case of breakdown or fault. Panel
manufacturer have to submit electrical meter calibration report. Agency should design the panel in such a way that there
should not be any excess in panel area (sq.mtr) & length of bus-bar (mtr), if any excess occurs draw attention to
GSPHCL at the time of approval of G.A. drawing. Loading and unloading of above item shall be done by hydra and skill
work force under supervision of electrical engineer and guidelines given by manufacturer to avoid damage to the item.
Picture of it to be submitted in running bill / final bill. Size of door and Ele. room / Pump room shall be checked by
agency's engineer before giving order. If found any problem in size discuss with GSPHCL engineer for rectification
before giving order. [Including Necessary numbering / marking on PANEL done with red colour radium sticker as per site
requirement and instructions given by EIC on site. Font / number size given by EIC on site as per requirement] (All
Panel as per IEC 61439 as per NBC Guideline) [Manufacturer must be of Gujarat state so three stage inspection can be
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
381 Providing & erecting weather proof, dust & vermin proof, floor mounted front operatedouble door cubical panel board 1.00 Sq. Mtr. 17777.00 RS: Seventeen Thousand Seven
necessary IP-54 & above protection as per approval from engineer incharge and made from 2 mm. thick CRC M.S. Hundred Seventy Seven only
sheet for outer body & doors, 1.6 mm. thick CRC M.S. sheet for internal partitions with necessary supporting angles,
flats including skirting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements &
instruction of engineer-In-Charge with erection of supplied switchgears, busbars with suitable size of interconnecting
PVC copper wire / Copper-Aluminium strips, rubber gromets, rib, control wires, backelite control fuses, measuring
instruments, earth bus & earth bolts, foundation flange-bolts-base plates, sufficient nos. of hinged doors, handle with
locking arrangement, rubber gasket complete with Required Nos. heavy Duty Connector with Cadmium plated nut and
bolt for Anti rusting The panel shall be supplied with Seven Tank chemical process which shall be carried out before
applying painting, painted with powder coating. (The rates excludes the cost of switchgears, busbars, interconnecting
mains & Copper / Aluminium strip, fuse, meters etc. The dimension shall be measured excluding base beams) The
standard companies switch gear shall be used and only manufacturers at CPRI approved factory as per IEC 61439 and
shall be certified by that company whose switch gears are used after fabrication for beneficial use. With 350 mm depth
Panel manufacturer have to give 5 years maintenance and service support if in case of breakdown or fault. Panel
manufacturer have to submit electrical meter calibration report. Agency should design the panel in such a way that there
should not be any excess in panel area (sq.mtr) & length of bus-bar (mtr), if any excess occurs draw attention to
GSPHCL at the time of approval of G.A. drawing.Loading and unloading of above item shall be done by hydra and skill
work force under supervision of electrical engineer and guidelines given by manufacturer to avoid damage to the item.
Picture of it to be submitted in running bill / final bill.Size of door and Ele. room / Pump room shall be checked by
agency's engineer before giving order. If found any problem in size discuss with GSPHCL engineer for rectification
before giving order. [Including Necessary numbering / marking on PANEL done with red colour radium sticker as per site
requirement and instructions given by EIC on site. Font / number size given by EIC on site as per requirement] (All
Panel as per IEC 61439 as per NBC Guideline) [Manufacturer must be of Gujarat state so three stage inspection can be
382a Supplying and erecting tripple pole & neutral 440V / 500 V Panel mounting Copper Busbars with four 2.00 Rn. Mtr. 1942.00 RS: One Thousand Nine Hundred
equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current / Forty Two only
cross section area) duly wraped with colour insulating tape for phase sequence of following current
carrying capacity, erected with necessary bus bar supports / insulators, main cable socket to each bar,
erected in existing cubical panel with necessary connections.For electrolyte copper busbars Suitable for
100 Amp. capacity.
382b For Suitable for 200 Amp. Capacity 2.00 Rn. Mtr. 3171.00 RS: Three Thousand One
Hundred Seventy One only
382c For Suitable for 300 Amp. Capacity 2.00 Rn. Mtr. 4861.00 RS: Four Thousand Eight
Hundred Sixty One only
383 SITC of ATS with controller for 63 Amp of ampere capacity in existing housing with internal wiring and 6.00 Nos. 35187.00 RS: Thirty Five Thousand One
required accessories etc. The switch has automatic transfer switch consists of an intelligent controller Hundred Eighty Seven only
and a modular load break switch which automatically transfers the load to the emergency power source
when it detects the normal power source under/over voltage, under/over frequency, or phase loss. The
switch has three operational positions (Source I, Center-off, Source II). The switch has technical
specification as mentioned:
1. Rated insulation voltage:800 V
2.Rated impulse withstand volate: 8KV
3.Rated frequency:50/60HZ
4. Operational Volatge: 415 V
5.auxilary contact: 4 max
(socomec, schneider make or EIC)
384 SITC of ATS with controller for 125 Amp of ampere capacity in existing housing with internal wiring and 1.00 Nos. 54598.00 RS: Fifty Four Thousand Five
required accessories etc. The switch has automatic transfer switch consists of an intelligent controller Hundred Ninty Eight only
and a modular load break switch which automatically transfers the load to the emergency power source
when it detects the normal power source under/over voltage, under/over frequency, or phase loss. The
switch has three operational positions (Source I, Center-off, Source II). The switch has technical
specification as mentioned:
1. Rated insulation voltage:800 V
2.Rated impulse withstand volate: 8KV
3.Rated frequency:50/60HZ
4. Operational Volatge: 415 V
5.auxilary contact: 4 max
(socomec, schneider make or EIC)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
385 Supplying and Erecting Approved make Four pole moulded case circuit breaker having breaking capacity 2.00 Each 20739.00 RS: Twenty Thousand Seven
ICU of 35 K.A. at 415 V. having normal current rating 250 A. with Variable thermal & magnetic release Hundred Thirty Nine only
suitable to work on A.C.supply 50 c/s. with all internal connections spreader tinned copper & complete
erected in existing 16 G.M.S. housing. housing. ICS=100% of ICU only
386 Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 2.00 Each 16061.00 RS: Sixteen Thousand Sixty
V. having normal current rating 200A. with Fixed thermal & magnetic release suitable to work on One only
A.C.supply 50 c/s. with all internal connections,spreader tinned copper & complete erected in existing
G.M.S. housing. ICS=100% of ICu only.
387 Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 4.00 Each 7976.00 RS: Seven Thousand Nine
V. having normal current rating 125A. with Fixed thermal & magnetic release suitable to work on Hundred Seventy Six only
A.C.supply 50 c/s. with all internal connections,spreader tinned copper & complete erected in existing
G.M.S. housing. ICS=100% of ICu only.
388 Supplying and Erecting Approved make Four pole moulded case circuit breaker having breaking capacity 9.00 Each 6112.00 RS: Six Thousand One Hundred
ICU of 25 K.A. at 415 V, having normal current rating 25 A to 100 A. with Fixed thermal & magnetic Twelve only
release suitable to work on A.C. supply 50 c/s. with all internal connections spreader tinned copper &
complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only.
389 Providing & Erecting (A) Extended operating rotary handle with pad lock with three position trip,off,on 4.00 Each 865.00 RS: Eight Hundred Sixty Five
suitable for 25A to 250 A panel mounting ( company must be same as switchgher company) only
390 Supplying and erecting Approved make Earth fault Relay suitable to mount with inter connection to 4.00 Each 4641.00 RS: Four Thousand Six Hundred
moulded case circuit breaker having CT ratio & MCCB rating as following along with shunt trip 220 V AC Forty One only
with all internal connections & complete erected in existing M.S.housing.63 A., CT Ratio 1/100
391 Supplying and erecting Approved make Earth fault Relay suitable to mount with inter connection to 1.00 Each 5362.00 RS: Five Thousand Three
moulded case circuit breaker having CT ratio & MCCB rating as following along with shunt trip 220 V AC Hundred Sixty Two only
with all internal connections & complete erected in existing M.S.housing 250A
392 Providing & erecting Miniature circuit breaker single pole 6 Amp. to 25 Amp. suitable to operate on 240 V 1069.00 Each 111.00 RS: One Hundred Eleven
A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS only
8828/1996 with ISI Mark.
393 Providing & erecting 240 V MCB Double pole switch for Motor & Inductive Load (c curve) having 10 KA 6.00 Each 327.00 RS: Three Hundred Twenty
breaking capacity & confirms to IS:8828 in Existing M.S. box having following capacity. For 40 Amp. Seven only
394 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking 51.00 Each 730.00 RS: Seven Hundred Thirty
capacity & confirms to IS :8828 in existing box having following capacity [c] 63 Amp. only
395 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking 20.00 Each 905.00 RS: Nine Hundred Five only
capacity & confirms to IS :8828 with encloser (Powder coated) box having following capacity 63A with
396 Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short 12.00 Each 3010.00 RS: Three Thousand Ten
Circuit withstand capacity of 10 KA and suitable for operation on 3 phase and neutral 415V. having only
characteristic of quick action & tripping with all advance feature & do not incorporate any electronic
component for following Max. rating erected as directed.(ii) 63Amps. FP
397 Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short 2.00 Each 2611.00 RS: Two Thousand Six Hundred
Circuit withstand capacity of 10 KA and suitable for operation on 3 phase and neutral 415V. having Eleven only
characteristic of quick action & tripping with all advance feature & do not incorporate any electronic
component for following Max. rating erected as directed.(ii) 40Amps. FP
398 Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short 2.00 Each 2611.00 RS: Two Thousand Six Hundred
Circuit withstand capacity of 10 KA and suitable for operation on 3 phase and neutral 415V. having Eleven only
characteristic of quick action & tripping with all advance feature & do not incorporate any electronic
component for following Max. rating erected as directed.(ii) 32Amps. FP
399 Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short 18.00 Each 2213.00 RS: Two Thousand Two Hundred
Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic Thirteen only
of quick action & tripping with all advance feature & do not incorporate any electronic component. for
following Max. rating erected as directed (i) 40 Amps.DP (Parking DB)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
400 Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short 12.00 Each 1950.00 RS: One Thousand Nine Hundred
Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic Fifty only
of quick action & tripping with all advance feature & do not incorporate any electronic component. for
following Max. rating erected as directed (i) 25 Amps.DP
401 Supplying & erecting bank of all polypropylene condenser (APP type) with standard capacity of 2,3,5,7, 60.00 kvar 577.00 RS: Five Hundred Seventy
10,12.5 & 15 KVAR units of P.F. correction for operation on 3 phase 50 c/s, 400 /440V (+ / - 10%) with Seven only
externally discharging resistance, earthing terminal & built on angle iron of channel iron frame work and
provided with terminal cover box. Complete erected on provided iron bracket or on floor duly tested by
license.(FOR LIFT)
402 Providing and erecting metalic danger notice board for MEDIUM VOLTAGE installation to be erected as 4.00 Each 69.00 RS: Sixty Nine only
403 Supplying & erecting aproved make Panel mounting type Digital Ammeter having Three Digits LED 2.00 Each 1543.00 RS: One Thousand Five Hundred
Display,0.5 class of accuracy, External CT operated Calibrated for 0 to 1000 Amps suitable to operate on Forty Three only
500 Volt AC erected on existing panel board with all connection wiring etc.with manufacturers calibration
404 Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 x 1/2 digits LED 2.00 Each 1263.00 RS: One Thousand Two Hundred
display, 0.5 class of accuracy 0 to 750 AC Volts range erected on existing panel board with all Sixty Three only
connection, wiring etc. with manufacturers calibration certificate.
405 Supplying and erecting Ammeter / Voltmeter selector switch for 3 phase AC Supply 500 V on existing 4.00 Each 314.00 RS: Three Hundred Fourteen
panel board with necessary connections. only
406 Supplying and erecting approved make set of indicator lamps of LED type lamp, lense cover, Bakelite 14.00 Each 43.00 RS: Forty Three only
holder complete erected with necessary connections.
407 Providing, erecting, testing and commissioning of L.T. Current Transformer with bus bar primary 50/5 to 15.00 Each 272.00 RS: Two Hundred Seventy Two
1000/5 ratio 15 VA burden. Duly secured with insulating materials connected to the meter. only
408 providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA 12.00 Each 2213.00 RS: Two Thousand Two Hundred
and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. Thirteen only
having characteristic of quick action & tripping with all advance feature & do not incorporate any
electronic component. for following Max. rating erected as directed (ii) 40Amps. DP
409 Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel 20.00 KG 787.00 RS: Seven Hundred Eighty
board, Motors etc. using copper clamp. Seven only
410 Providing and erecting required size Aluminium strip for earthing of H.T., OCB / ACB / Transformer, LT 100.00 KG 223.00 RS: Two Hundred Twenty Three
panel board, Motors etc. using copper clamp. only
411 Supply, Installation, Testing & Commissioning of Three Phase, 440 V Surge Suppressor protection 2.00 Each 6319.00 RS: Six Thousand Three
Device (SPD) & 40 Amp TPN MCB (or As per SPD OEM guide line for the protection of SPD which is Hundred Ninteen only
erected such a way that it can be operated easily) SPD must be capable to protect all electrical and
electronics equipments if SPD blast or fuse then the panel builder must have replace it soon during
defect liability period.The Detail Specification of SPD are As per Attached sheet with Annexture -A(E).
(Hakel,ikra,OBBO make) (With Three year Gaurantee/warranty)
412 Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ 100.00 KG 77.00 RS: Seventy Seven only
Transformer LT panel board, Motors etc. using proper clamp with min 80 micron as per IS.Test certificate
must be submitted by agency.
413 Providing and erecting Meter cover made from multi chamber hollow PVC sections of 20 mm thick 12.00 sq mtr 3306.00 RS: Three Thousand Three
having all the corner joints with PVC solution angles without using any screws, nails shutters having Hundred Six only
required size of eye glass and with necessary locking arrangement hinged with box. The back of meter
box should be fixed with timber. Hold fast for holding screws or nut bolts.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
414 Design, Supplying, installing, testing of factory fabricated ready made Three phase APFC Panel Cubical 1.00 Each 141527.00 Rs: one lac fourty one thousand five
Panel fabrication should be type tested as per IEC 61921, 61439:1&2 Capacitor Duty Contactor for hundred twenty seven only.
switching as per following Steps Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with
Microprocessor based OC, SC, internal earth fault protection Incomer Switch of MCCB type
Icu=Ics=50KA at 400/440 Volts, with Microprocessor based OC, SC, internal earth fault
protection,Copper tinned insulated Busbar,Cubical panel should be indoor type with IP 43 and IK
10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor for each
capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor having suitable MCCB
with Sc, OL, internal earth fault relay,Each stage having Stage Contactor (Capacitor load rating),PF
regulator master controller having suitable steps with LCD display, Rs 485 Communication port,
Indication LED Lamps for main incomer and ON-OFF for each capacitor bank,MS Chanel for Floor
mounting, Cable entry as per site situation,Cooling fans for panel. For 50KVAR. (As per attached
415 Providing & Erecting 2.0 mtr long Earthing system by making minimum bore of 225 mm dia in soft soil. Suitable for 16.00 Each 7025.00 RS: Seven Thousand Twenty
doing pipe-in-pipe technology earthing.Earthing electric rod must be made from Corrosion free Hot dip galvanizing pipes Five only
having following specification.
(A) Earthing Electrode: outerpipe:- 88 mm minimum O.D., ISI 'B ' Class ISI mark of Reputed Brand, Inner pipe:- 42 mm
minimum O.D., Pipe B Class ISI mark reputed Brand Terminal Size: 70mm X 100mm length, Terminal Should be made
from inner pipe for that pipe must be pressed and gave rectangular shape so its work as a terminal.The hot deep
galvanising must be done after above process.Galvanised thickness must be minimum 75 micron any where. SS Nut
bolt:- 2 no.with washer suitable for 14mm dia. hole must be provided at terminal. total minimum Weight(approx.) of earth
electrodewith inside conductive material minimum should be 26 kg.
(B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm/meter testing as per IEC 62561-2017, Voltage drop:- <
volt at no load & dry form, Sulphar content:- <2%
(C) Back fill Compound:- Earthing compound should be capable to retain moisture for long time Back Filling Compound
weight is 25 Kg.
(D) Chamber and cover:- Earthing chamber should be size of 400 mm X 400 mm X 400 mm depth and Cover should be
heavy duty cast iron with required size of 300 mm X 300 mm X 4 mm thick. Necessary test report must be submitted.
1. Short circuit test by ERDA/ CPRI for 25KA
2. Resistivity test of conducting material from NABL accredited lab.
3. Hot dip galvanised / zinc coating micro test from reputed laboratory.
4. General test report from OEM regarding specification of earthing.
[Make and model approved by EIC Strictly subject to item specification only] [OEM has to submit all detail & sample for
approved before supplying]
[Water must be poured in bore before starting earthing. Earthing value must be measured with earth tester. Agency has
to bring the earth resistance to at least 02 ohms & voltage between neutral & Earthing upto 02 volt. Agency has to
maintain earthing & its value for one year. Earthing must be done in the presence of A.E. (GSPHCL)]
416 For above earthing additional charges for boring in hard rock soil (by breaker) & filling soft soil in earth 16.00 Each 276.00 RS: Two Hundred Seventy Six
pit (certificate for soil have to given by DEE / AE along with photographs) only
417 Providing and erecting following type of Modular Type Accessories mounted with 20 G G.I. company 20.00 Each 159.00 RS: One Hundred Fifty Nine
fabricated metalic box, single mounting base frame covered with textured / metallic front plate, modules only
erected with necessary connection. As desired by Engineer in charge.Two pin / RJ-11 Telephone Socket
(For One Gang) Cat-III
418 Modem Jack for Computer Open RJ-45. Cat.-III. 125.00 Each 159.00 RS: One Hundred Fifty Nine
419 SITC of specified make X color for Cat.-6 Data and Y color for Cat.-6 voice cable to be done in prelaid 6200.00 Mtr. 47.00 RS: Forty Seven only
PVC pipe / raceway, but without the cost of raceway or pipe (the wire is to be drawn from MFD/ JB to
outlet point) (a) CAT - 6 (For Computer Cabling and For Voice Cabeling) (Molex, R&M, Avaya, Systimax,
Legrand make Only)
420 SITC of company fabricated Patch cords shall conform to Cat- 6 & conductor shall be stranded for better 125.00 Each 155.00 RS: One Hundred Fifty Five
flexibility Shall support network line speeds up to 1 Gbps Shall have RJ-45 jacks. For 1 Mtr.[Make and only
model approved by EIC as per specification]
421 SITC of company fabricated Patch cords shall conform to Cat- 6 & conductor shall be stranded for better 124.00 Each 199.00 RS: One Hundred Ninty Nine
flexibility Shall support network line speeds up to 1 Gbps Shall have RJ-45 jacks. For 2 Mtr. [Make and only
model approved by EIC as per specification]
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
422 SITC of 8 x 10/100/1000BASE-T PoE ports 22.00 Each 27601.38 RS: Twenty Seven Thousand Six
2 x Gigabit SFP ports Hundred One and Paise Thirty Eight
Advanced L2 switching and security features only
L2+ Static Routing
Optional “standard mode” or “surveillance mode” management user interface
65W PoE budget (Including Five year free maintenance with guarantee)
423 Supply and installation of 4U steel rack for installing 1 nos. Ethernate switches/Hubs. The Rack should 20.00 Each 3199.00 RS: Three Thousand One
be fully enclosed steel housing fabricated with 14 SWG sheet and powder coated with glass doors and Hundred Ninty Nine only
having wire management systems. The rate includes the Exhaust Fan, 1 nos. 4 socket and 1 switch
power strip and all the wiring in the rack. (Rittal, Valrack, APC, Legrand Make and model approved by
EIC as per specification)
424 Providing & erecting Switch board for Computer or electric apparatus consisting of following items in 80.00 Each 1122.00 RS: One Thousand One Hundred
single board erected on Metal board with 3 mm thick PC (Polycarbonet) / Acrylic sheet erected as Twenty Two only
directed. 2 no. 6/16 Amp. universal Socket, 2 nos. 16 Amp. indicator switch, 2 nos. 6 Amp. Switch &
nos. 6 Amp. 5 pin Plug. For Computer power Supply board. Cat.-III.
425 Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid 10.00 Mtr. 275.00 RS: Two Hundred Seventy Five
material with ignition free & flame proof confirming BS .All necessary accessories and measuring of only
following sizes.For 75 mm x 50 mm trunking.[MK, LEGRAND, OBBO make Only]
426 For 100 mm x 50 mm trunking (MK, LEGRAND, OBBO make Only]) 10.00 Mtr. 424.00 RS: Four Hundred Twenty Four
427 For 50 mm x 50 mm trunking (MK, LEGRAND, OBBO make Only ) 10.00 Mtr. 187.00 RS: One Hundred Eighty Seven
428 Providing & Erecting PVC Perforated trunking Channel of Size 45mm X 45mm with required size of 100.00 MTR 153.00 RS: One Hundred Fifty Three
screw as directed by EIC ( Make: Precision/Premium or Equivalent make approved by EIC ) only
429a Providing & erecting XLPE (IS : 7098) (I)-88 ISI marked armoured Aluminium conductor cable for 1100 25.00 mtr 1157.00 RS: One Thousand One Hundred
volt to be laid 90 cms. Under ground or to be laid on wall with 1.00 m.m thick G.I. heavy guage cable Fifty Seven only
clamp or in existing DWC pipe underground or road crossing or floor. (I) 3 1/2 core 240 Sq. mm(
Sq. mm 1/2 core)
429b Providing & erecting XLPE (IS : 7098) (I)-88 ISI marked armoured Aluminium conductor cable for 1100 100.00 mtr 896.00 RS: Eight Hundred Ninty Six
volt to be laid 90 cms. Under ground or to be laid on wall with 1.00 m.m thick G.I. heavy guage cable only
clamp or in existing DWC pipe underground or road crossing or floor. (I) 3 1/2 core 185Sq. mm(
Sq. mm 1/2 core)
429c Providing & erecting XLPE (IS : 7098) (I)-88 ISI marked armoured Aluminium conductor cable for 1100 200.00 mtr 486.00 RS: Four Hundred Eighty Six
volt to be laid 90 cms. Under ground or to be laid on wall with 1.00 m.m thick G.I. heavy guage cable only
clamp or in existing DWC pipe underground or road crossing or floor. (E) 3 1/2 core 95 Sq. mm (
Sq. mm 1/2 core)
429d Providing & erecting XLPE (IS : 7098) (I)-88 ISI marked armoured Aluminium conductor cable for 1100 50.00 mtr 282.00 RS: Two Hundred Eighty Two
volt to be laid 90 cms. Under ground or to be laid on wall with 1.00 m.m thick G.I. heavy guage cable only
clamp or in existing DWC pipe underground or road crossing or floor. (C) 3 1/2 core 50 Sq. mm (
Sq.1/2 mm core)
429e Providing & erecting XLPE (IS : 7098) (I)-88 ISI marked armoured Aluminium conductor cable for 1100 100.00 mtr 182.00 RS: One Hundred Eighty Two
volt to be laid 90 cms. Under ground or to be laid on wall with 1.00 m.m thick G.I. heavy guage cable only
clamp or in existing DWC pipe underground or road crossing or floor. (A) 3 1/2 core 25 Sq. mm (
Sq. mm 1/2 core)
429f Providing & erecting XLPE (IS : 7098) (I)-88 ISI marked armoured Aluminium conductor cable for 1100 200.00 Mtr 152.00 RS: One Hundred Fifty Two
volt to be laid 90 cms. Under ground or to be laid on wall with 1.00 m.m thick G.I. heavy guage cable only
clamp or in existing DWC pipe underground or road crossing or floor .For 4 core 16 Sq. mm
430a Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Soild Copper conductor for 800.00 Mtr. 361.00 RS: Three Hundred Sixty One
1.1 KV. to be laid on wall with necessary clamps 1.00 mm thick to be laid 90 cms underground with 1.00 only
mm thick G.I heavy duty grade or in existing trench / pipe at road crossing or floor of following size of
cables.(A) 4 core 4 Sq. mm
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
430b Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 200.00 mtr 670.00 RS: Six Hundred Seventy
KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of only
following size of cables. .(A) 4 core 10Sq. mm
430c Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 200.00 mtr 1490.00 RS: One Thousand Four Hundred
KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of Ninty only
following size of cables. .(C) 4 core 25 Sq. mm
431 Providing & erecting XLPE (IS : 7098) (I)-88 ISI marked unarmoured Copper cable for 1100 volt to be laid 180.00 mtr 568.00 RS: Five Hundred Sixty Eight
90 cms. Under ground or to be laid on wall with suitable G.I. heavy guage 1.0mm thick cable clamp or in only
existing DWC pipe underground or road crossing or floor. (a) For 4 core x 10 sq.mm.
432a Providing & fixing Double compressed heavy duty flange type brass cable gland with rubber ring for P V 10.00 Each 57.00 RS: Fifty Seven only
C insulated armoured cable complete with outgoing tails, insulating tape etc. For following size cables.
For 2 to 4 core x 16.0 Sq. mm
432b Providing & fixing Double compressed heavy duty flange type brass cable gland with rubber ring for P V 8.00 Each 61.00 RS: Sixty Six only
C insulated armoured cable complete with outgoing tails, insulating tape etc. For following size cables.
432c Providing & fixing Double compressed heavy duty flange type brass cable gland with rubber ring for P V 8.00 Each 66.00 RS: Sixty Six only
C insulated armoured cable complete with outgoing tails, insulating tape etc. For following size cables.
For 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core)
432d Providing & fixing Double compressed heavy duty flange type brass cable gland with rubber ring for P V 8.00 Each 75.00 RS: Seventy Five only
C insulated armoured cable complete with outgoing tails, insulating tape etc. For following size cables.
For 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
432e Providing & fixing Double compressed heavy duty flange type brass cable gland with rubber ring for P V 8.00 Each 130.00 RS: One Hundred Thirty
C insulated armoured cable complete with outgoing tails, insulating tape etc. For following size cables. only
For 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
432f Providing & fixing Double compressed heavy duty flange type brass cable gland with rubber ring for P V 8.00 Each 236.00 RS: Two Hundred Thirty Six
C insulated armoured cable complete with outgoing tails, insulating tape etc. For following size cables. only
For 3 1/2 core 185Sq. mm( 120 Sq. mm 1/2 core)
432g Providing & fixing Double compressed heavy duty flange type brass cable gland with rubber ring for P V 8.00 Each 245.00 RS: Two Hundred Forty Five
C insulated armoured cable complete with outgoing tails, insulating tape etc. For following size cables. only
For 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core)
432h Providing & fixing Double compressed heavy duty flange type brass cable gland with rubber ring for P V 30.00 Each 43.00 RS: Forty Three only
C insulated armoured cable complete with outgoing tails, insulating tape etc. For following size cables.
For 2 to 4 core x 4.0 Sq. mm (Sigma, MCI, Comet, HMI Make Only)
432i Providing & fixing Double compressed heavy duty flange type brass cable gland with rubber ring for P V 16.00 Each 48.00 RS: Forty Eight only
C insulated armoured cable complete with outgoing tails, insulating tape etc. For following size cables.
to 4 core x 10.0 mm2 (Sigma, MCI, Comet, HMI Make Only)
435j 12.00 Each 25.00 RS: Twenty Five only
Providing & fixing PVC cable gland with rubber ring for P V C insulated unarmoured cable complete with
outgoing tails, insulating tape etc. For following size cables. (a)For 2 to 4 core x 6.0 to 10Sq. mm
436a Providing & fixing Solderless crimping type Aluminium lugs conforming to IS suitable for cable of 101.00 Each 15.00 RS: Fifteen only
following size evenly crimped with high pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. For 16/25 Sq.mm. Allumium Cable
436b Providing & fixing Solderless crimping type Copper lugs conforming to IS suitable for cable of following 1000.00 Each 8.00 RS: Eight only
size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium
plated nut bolts in an approved manner. [a] 1.5/2.5 to 6 Sq.mm
436c Providing & fixing Solderless crimping type Copper lugs conforming to IS suitable for cable of following 34.00 Each 10.00 RS: Ten only
size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium
plated nut bolts in an approved manner. [a] For 10sqmm
436d Supplying following size of Light duty “A” Class G.I. Pipe & erecting as directed by Engineer-in-charge. 10.00 Mtr. 171.00 RS: One Hundred Seventy One
For 25 mm dia. only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
437a Providing & Erecting Mains with ISI marked, 1.1 KV grade electrolyte multi stranded, annealed copper 150.00 Mtr. 37.00 RS: Thirty Seven only
conductor with heat resistant PVC insulated conforms to IS:694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if required. [f] One wire 4.00 sq. mm
437b One wire 6.00 sq. mm 150.00 Mtr. 56.00 RS: Fifty Six only
437c One wire 10.00 sq. mm 300.00 Mtr. 91.00 RS: Ninty One only
437d One wire 16.00 sq. mm 460.00 Mtr. 141.00 RS: One Hundred Forty One
437e One wire 25.00 sq. mm 150.00 Mtr. 234.00 RS: Two Hundred Thirty Four
437f One wire 35.00 sq. mm 150.00 Mtr. 298.00 RS: Two Hundred Ninty Eight
437g One wire 50.00 sq. mm 100.00 Mtr. 466.00 RS: Four Hundred Sixty Six
437h One wire 70.00 sq. mm 100.00 Mtr. 663.00 RS: Six Hundred Sixty Three
437i One wire 95.00 sq. mm 100.00 Mtr. 910.00 RS: Nine Hundred Ten only
437j One wire 120.00 sq. mm 50.00 Mtr. 1167.00 RS: One Thousand One Hundred
Sixty Seven only
438a Providing & laying HDPE Double walled corrugated pipes (DWC) (conforming to IS: 16205 (part 24) 850.00 Mtr. 117.00 RS: One Hundred Seventeen
2018)) with minimum load required of 450N capacity with anti rodent and ultra violet material properties only
with necessary connecting accessories of same material at required depth to be laid 90 cms. under
ground for laying of cable below ground / road surface for enclosing cable and back filling the same to
make ground as per original. (A) For Outer dia. 50 mm and Inner dia. 38 mm. ) (Test Certificate to be
438b For Outer dia. 90 mm and Inner dia. 75 mm. (Test Certificate to be Submitted) 50.00 Mtr. 150.00 RS: One Hundred Fifty only
438c For Outer dia. 120 mm and Inner dia. 100 mm. (Test Certificate to be Submitted) 50.00 Mtr. 191.00 RS: One Hundred Ninty One
439 Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cms. below ground across the road crossing 20.00 Mtr. 340.00 RS: Three Hundred Forty
or on floor with necessary material in an approved manner and making the ground as per original.(C) 300 only
440 HYDROPNEUMATIC PUMPSETS . 1.00 Each 527360.62 RS: Five lac Twenty Seven
Variable Speed VFD Driven in-line, vertical multistage, centrifugal clear water pumps, speed upto 2900 Thousand Three Hundred Sixty and
rpm, with Galvanised M.S / SS Suction & Discharge chamber and SS casing (body), S.S 304 impeller Paise Sixty Two only
and SS-304/410 shaft,Pump Body S.S 304,outer sleeve S.S 304 Alluminium Base, connected to a TEFC
motor (with mechanical seal) suitable for 380 / 440 volts, 3 phase 50 cycles A.C. supply, GI Suction &
Discharge headers with valves and accessories, Hydro booster pressure vessel rated for 20 bar
pressure of approx. 200 liters capacity on common CI/MS epoxy painted skid. Pumpsets to be fixed on
RCC/PCC foundation with foundation bolts /vibration eleminating pads as required. ( Anti Vibration
/foundation Pads, base frame shall be supplied by motor-vendor) Skid mounted Electrical Starter panel
IP 55 composite for one set of pumps complete with Main Incoming MCB, VFD / Multi VFD as per site
requirement and MPCB with single phasing preventer, contactors, control contactors, dry run trip relay
with presure/flow transmitter in suction header, ON-OFF and TRIP Indicating LED type lamps, PLC
based pump controller suitable to work as per operation logic furnished, cascade operation, automatic
working/standby selection for equal run time ,cyclic timer etc. suitable for the pump capacity as
specified below. Panel shall have auto-manual - off switch for operation in manual mode/automation
mode. Domestic water transfer pumps for water transfer from underground to over head tanks of 1Set (
For All Buildings) Supplying, installing, testing and commissioning pressur booster pump. Flow rate for
each pump - 18 m3/hr (4 nos.) System Flow rate - 72 m3/hr Total Head range: 60 to 80 mtr.Minimum
KW each pump set capacity.Pressure Tank: 200 ltrs. x 1 no per Set (3W+1S)/set. 300 LPM (per Pump),4
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Pressure Vessel -200 Ltr. /Set (To pump domestic water to OH tanks).Motor having class of insulation -
F,Enclosure IP55,Efficency of class IE2.Including : Pumps water pump with MOTOR - 4 Nos, Pressure
Transmitter-1No., Non-Return Valve - 4 Nos, Isolating Valve-8 Nos, Pressure Gauge- 1 Nos, Suction and
Discharge Header - 1 Nos, Base Frame - 1 Nos, Control Panel with VFD - Multi VFD Note: The head
range mentioned is as per tentative.The actual duty point head shall be decided by OEM and civil
agency.For that civil agency has to given height of building,height of over head tank,depth of sump,height
of basement,Plumping network drawing with diameter of pipe,length of vertical & horizontal pipe,number
of bend,tee,elbow,valve etc. to OEM and discharge required as per tender.OEM has to submit the total
equivalent head calculation & submit suitable model of pump to get sufficient discharge of water at over
head tank as per tender.Civil agency has to get approval of pump model strictly as per tender
specification before giving order.
441 Executing comprehensive (All in All) service & maintenance(Including replacement of VFD+Motors) with 1.00 Job. 50000.00 RS: Fifty Thousand only
spare parts as per terms & condition of tender HPN manufacture for defect liability period.For that
mainagancy has to give All in All comprehensive maintenance contract to HPN manufacturer and copy of
this contract and FDR must be submitted before final bill .Agency has to quote rate accordingly.Agency
has to also provide the fitness certificate from HPN manufacturer and submit to GSPHCL.Agency has to
submit compulsory FDR of Rs 50000.00 + GST or quoted amount whichever is higher to GSPHCL.
Which will be released after successful completion of AMC & at the and of defect liability
period.HPN OEM has to maintain written record of service & maintenance during defect liability daily
period duly singh by police dept.and submitted redulary to GSPHCL.HPN agency has to do maintenance
as per term & Condition altarenet in tender for delay in rectifying the fault,penalty will be deduced from
agency S.D For 3 pumps.
442 Providing & Erecting Flexible PVC insulated multistrand multicore 1.1 kv grade ISI marked copper wires 280.00 Mtr. 46.00 RS: Forty Six only
of following size to be erected as directed. 3 core 1.5 sq.mm. PVC insulated round copper wire ISI mark.
443 Providing & Erecting Flexible PVC insulated multistrand multicore 1.1 kv grade ISI marked copper wires 51.00 Mtr. 77.00 RS: Seventy Seven only
of following size to be erected as directed. 3 core 2.5 sq.mm. PVC insulated round copper wire ISI mark.
444 Providing and Fixing SITC of Outdoor aesthetically designed LED Street Light Luminaire with total 28.00 Each 3512.00 RS: Three Thousand Five
consumption of Max. 45 W with single piece die cast aluminium housing, high power LED shall be Hundred Twelve only
mounted on high quality metal core PCB with extremely precison designed heat sink complete with IP66
protection Class with polycarbonate / thoughened glass cover the fixture should be suitable for
pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines with LED module min.
lumen/watt with toughen Glass L70 at 50,000 hrs, provided with high quality polycarbonate lenses for
better light distribution. The Fixture Should be able to be Pole Mounted and also bracket mounted,
provided with high quality driver for protection against high and low Voltage cut Off, opertional for high
amibient and high humid envirnoments, THD of driver should be less than 10% and P.F > 0.95. Also the
Fixture should meet the following technical criterias Oprating range Voltage 160 to 270 V, system
efficiency >= 110 lm/w, and total lumens not less then 4950, CCT > 5000K, CRI > 65, beam angle
deg, surge immunity level at least 4 KV integral and 10 KV non integral
The Separate Potted driver should have over current, over voltage protection, short circuit protection so
that the fixture recovers once the fault is removed. In addition to the above product should be operational
in the temperature range of 0 deg to 50 deg and humidity range of 10% to 90% RH. (Note:- The
manufacturer / authorized Channel partner of the manufacturer has to submit 5 yrs free replcement
Guarantee for complete Fixture)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
445 Providing and Fixing SITC of Outdoor aesthetically designed LED Street Light Luminaire with total 2.00 Each 6117.00 RS: Six Thousand One Hundred
consumption of Max. 90 W with single piece die cast aluminium housing, high power LED shall be Seventeen only
mounted on high quality metal core PCB with extremely precison designed heat sink complete with IP66
protection Class with polycarbonate / thoughened glass cover the fixture should be suitable for
pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines with LED module min.
lumen/watt with toughen Glass L70 at 50,000 hrs, provided with high quality polycarbonate lenses for
better light distribution. The Fixture Should be able to be Pole Mounted and also bracket mounted,
provided with high quality driver for protection against high and low Voltage cut Off, opertional for high
amibient and high humid envirnoments, THD of driver should be less than 10% and P.F > 0.95. Also the
Fixture should meet the following technical criterias Oprating range Voltage 160 to 270 V, system
efficiency >= 110 lm/w, and total lumens not less then 9900, CCT > 5000K, CRI > 65, beam angle
deg, surge immunity level at least 4 KV integral and 10 KV non integral
The Separate Potted driver should have over current, over voltage protection, short circuit protection so
that the fixture recovers once the fault is removed. In addition to the above product should be operational
in the temperature range of 0 deg to 50 deg and humidity range of 10% to 90% RH. (Note:- The
manufacturer / authorized Channel partner of the manufacturer has to submit 5yrs free replcement
Guarantee for complete Fixture)
446 SITC of Outdoor aesthetically designed LED Flood Light Luminaire with total consumption of maximum 2.00 Each 6228.00 RS: Six Thousand Two Hundred
90 W with single piece die cast aluminium housing, LED's mounted on high quality metal core based Twenty Eight only
PCB with extremely precison designed heat sink, complete with IP66 protection Class, with
polycarbonate / Toughened glass cover. The fixture should be suitable for pole/bracket mounting. The
fixture to comply both LM79 and LM 80 guidelines with LED minimum 110 lumen/watt with L70 at
hrs, provided with high quality polycarbonate Seperate lenses for better light distribution. The Fixture
Should be able to be Pole Mounted and also bracket mounted, provided with high quality potted driver for
protection against, high and low Voltage cut Off, opertional for high amibient and high humid
envirnoments, THD of driver should be less than 10% and P.F > 0.95. Also the Fixture should meet the
following technical criterias. Operating range Voltage 160 to 270 V, system efficiency > 110 lm/w, CCT >
5000K, CRI >65, beam angle 120 deg, 4kV integral & non integral surge immunity level at least 10 KV
non integral... Flood Light lumens shall be more than 9900. (Note:- The manufacturer / authorized
Channel partner of the manufacturer has to submit 5yrs free replcement Guarantee for complete Fixture)
447 SITC 4K LED Bollard fittings of minimum height 600 mm & dia.100mm having polycarbonate clear/milky 12.00 Each 3130.00 RS: Three Thousand One
diffuser mounted on 3mm thick aluminium finished powder coated pipe with base plate 160x160mm with Hundred Thirty only
erection by M8x75mm fastner with required RCC foundation.IP65 for 15 watt, surge- 4 kv- cat-III
448 Supplying, Installing, Testing & Commissioning of 4K 40 W LED Outdoor type Post top Lantern light with 4.00 Each 4772.00 RS: Four Thousand Seven
IP65 protection with housing made of sturdy aluminium die cast housing with radiating cool surface and Hundred Seventy Two only
milky white high quality PMMA round cover with corrosion resistant Grey colour powder coating with high
efficiency potted driver with necessary safety precautions, 10 KV surge protection device with high min.
3200 lumens LED with long life of 30K @ L70 (L70@30000 hrs.), Installation bracket as per site
requirement, accessories 3C X 1.5 Sq.mm copper flexible wire upto terminal box etc. (Note:-The
manufacturer / authorised Channel partner of the manufacturer has to submit 5 years free replcement
Guarantee for complete Fixture) Cat III
449 Supplying and erecting approved make Octagonal pole made from HR sheet steel. The pole should be 18.00 Each 6917.00 RS: Six Thousand Nine Hundred
made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, suitable suspend Seventeen only
local wind speed with integral Junction box with Hot Deep Galvanised door having 2 nos. 180° operated
hinges & 2 nos. Ln key locking with silicon rubber gasket. Consist of terminal plate of min 6mm Hylam
sheet, standard profile 35 mm X 7.5 mm Din-Rail & MCB, Brass stud type terminal and arrangement for
cable termination to be erected on RCC foundation as per details given by manufacturer and EIC
considering site requirement.
Foundation Details: (1) Grade of RCC 1:2:4, (2) Grade of steel rainforcement of RCC FE 415, (3) Clear
cover to rainforcement 50mm, (4) Concrete vibrated, (5) use suttering / farma, (6) Hot deep galvanized
average 70 Micron, (7) Detail drawing will be given by corporation
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
(C) 5 Mtr. Long 70 mm Top X 130 mm bottom dia, 3 mm thickness with 200 mm X 200 mm X 12 mm
base plate, 4-M16 Bolts and 600 mm long hot deep galvanized J-Bolt, nuts, washers with 800 mm under
ground and 200 mm above ground level and Foundation in 1:2:4 proportion as per details given by
manufacturer and EIC considering site requirement. Approx Pole weight 46 kg.(Make:- Bajaj, Valmont,
Transrail, Ambica Only) (Test certificate to be submitted)
450 Supplying and making Coil type earthing, coil made from 8 SWG galvanised iron wire with 50 mm OD 18.00 Each 369.00 RS: Three Hundred Sixty Nine
and 50 turns (length of turns approx. 200 mm) and having additional continuous streight length of 3.00 only
mtr at open end and should be connected to earthing bolt and burried in 1.5 mtr deep specially prepared
earth pit complete with salt and charcoal/coke as required for coil type earthing.(Approx weight of coil
451 Providing & Erecting Universal Astro 5 KVA intelligent streetlight control system insu with weather proof 1.00 Each 12895.00 RS: Twelve Thousand Eight
box for outdoor application. (As per specification attached separately) (Make and model approved by Hundred Ninty Five only
452 Supplying and erecting Fabricating terminal box for street light pole made from 16 SWG M.S. sheet 10.00 Each 702.00 RS: Seven Hundred Two
having following size complete with fixing arrangement for terminal board, with necessary hole for wire only
entry and exit from the box. The box shall be provided with cover and hinges on one side and bolting at
other end The box shall be fixed by clamps fabricated from 25mm x 6mm flat.The box shall be painted
with one coat of red oxide and two coats of paint having following box size 330 mm x 260 mm x 140 mm
(depth). Providing and fixing Terminal board of size 5.0 x 127 x 152.4 mm.bakelite sheet with 15 Amp.
kitkat pattern porcelain fuse unit with suitable brass studs with nuts, washers and clamps of size 25 mm x
3 mm suitable for pole painted with one coat of red lead paint.
453 Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out approx. 10.00 Each 890.00 RS: Eight Hundred Ninty
2mm thick box complete with Bakelite connector strip 5way(3P+N+E), DIN rail for mounting mob & only
hinged doors as per requirement having locking arrangements with mounting clamp with nuts, bolts &
washers suitable for erection on pole with cable clamps& earth bolt of following size of box. (A) 300mm x
454 Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out approx. 5.00 Each 472.00 RS: Four Hundred Seventy Two
2mm thick box complete with Bakelite connector strip 5way(3P+N+E), DIN rail for mounting mob & only
hinged doors as per requirement having locking arrangements with mounting clamp with nuts, bolts &
washers suitable for erection on pole with cable clamps& earth bolt of following size of box. (A) 150mm x
455 Providing & erecting bracket consisting of ISI mark "B" class G.I. Pipe 4.2 cm outside diameter complete 10.00 Each 487.00 RS: Four Hundred Eighty Seven
with suitable G.I. Sleeve tubing of 2 mm. thick and required size and length suitable for 76.5 / 80 mm. only
required size of pole top or pipe in pipe surface for terrace as per instruction of EIC or wall bracket as per
instruction of EIC having nuts and bolts for fixing the brackets and having spread of Upto 0.50 mtr. length
with suitable rise as per site condition and suitable welded stiffner reducer and nipple with check nut
complete painted with one coat of yellow zinc and two coats of alluminium paint for Single arm bracket
suitable for pole or terrace as per design given by EIC (a) For single arm bracket. (Jindal / Asian / Tata /
Surya Prakash make Only) (Fabricators:- Bajaj, Valmont, Transrail, Ambica Only) (Test certificate to be
456 For Double arm bracket. (Jindal / Asian / Tata / Surya Prakash make Only) (Fabricators:- Bajaj, Valmont, 12.00 Each 616.00 RS: Six Hundred Sixteen
Transrail, Ambica Only) (Test certificate to be submitted) only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
457 Supplying and erecting, commissioning and testing 82.5 KVA Diesel Generating set as per the latest 1.00 Each 1091430.00 RS: Ten lac Ninty One Thousand
CPCBIV+ norms having continuous rating, 3 phase, 415 volts, 50 cycles A.C. supply comprising of a Four Hundred Thirty only
totally enclosed Water cooled diesel engine with multi-cylinders Inline arrangment developing suitable
BHP not less than following capacity at 1500 RPM with 10% overload for one hour in 24 hours Cost
including liaison work i.e. Preparation of site plan tracing & its blue prints, Site plan approval from Energy
& Petro. div., KWH Meter testing for D.G. Set, Site test report & other license stamped letter issuing,
Certificate from Elect. Inspector, Registration at Elect. Duty wing, Kutch. D.G.Set inclusive::: Testing:
Testing means full load & 10% over load testing of D.G.Set at Company / Dealer work shop. Cost
inclusive of Diesel, To & Fro Fair, Lodging boarding etc. of two engineer of corporation. Also full Diesel
tank with diesel ( 100% ) At the time of handing over D.G.Set to Benficial. 200 Ltr Capacity Heavy Duty
standard oil M.S./PVC Barrel & Diesel Filling hand Pump of required capacity.Agency has to give service
& All in All maintanance contract As per tender Item to OEM. During defect liability Period .Agency has
to replace oil,Diesel,filter,air filter,filing up DEF ( Diesel Exhuast Liquid ) etc as per site reguirement and
OEM Guideline & working hour of D.G set. Agency has to Provide fitness certificate at time of final SD
release.)..All parts of the DG set are warranted for the defect liability period and the agency will replace
them free of charge in case of manufacturing defects, transport damage or lack of regular service. The
details Specification of DG se is As Per Annexure A82.5
458 Executing comprehensive (All -in-All) service & maintenance with spare parts as per terms & condition of 1.00 Job. 208470.00 RS: Two lac Eight Thousand Four
tender Of DG Set agency for defect liability period. For that main agency has to give All-in-All Hundred Seventy only
comprehensive maintenance contract to DG set OEM/Authorised dealer and copy of this maintenance
contract as per annexure and FDR must be submitted with final bill. Agency has to compulsory submit
FDR of Rs.208470.00 + GST or quoted total amount which ever is higher to GSPHCL Which will be
FDR of Rs.208470.00 + GST or quoted total amount which ever is higher to GSPHCL Which will be
released after successful completion of AMC & at the end of defect liability period. DG set agency has to
maintain written record of service & maintenance during defect liability period duly sign by police dept.
and submitted regularly to GSPHCL. DG set agency has to do maintenance as per terms & condition in
tender. Agency has to replace Outer Air Element, Filter Element Primary, Oil Filter, Filter Element
Secondary, Gesket, Valve Cover, Belt Alternator, Fan Belt, Lube Oil, Coolant etc. as per site required &
working hours of D.G set.OEM has to Provide fitness certificate at the time of releasing S.D (For
459 Supplying, Erecting, Testing & Commissioning the 16 passengers , Ground plus 11 upper floors with 3.00 Each 3001155.00 RS: Thirty lac One Thousand One
Rated Speed of 2.0 m/sec with micro processor/PLC control and ACVVVF drive Lift having Hundred Fifty Five only
following main features:[1] GEAR LESS LIFT DRIVE comprising of High Starting torque Lift duty 3 phase
440 V A. C. Permanent magnetic synchronous motor of proper rating with high efficiency shall be used.(
MACHINE ROOM LESS/ MACHINE ROOM)
[2] Micro processor based / PLC, ACVVF, vector control drive with encoder feedback closed loop system
shall be used for lift car and door operation which shall be full collective selective operation hall call
demand response, UP/DOWN hall stops, Main, Up/ Down Contactor with overload and phase reversal
relay and safety controls. [3] Car with M S platform with bracings of adequate size and to sustain the
impact load cabin + passenger with safety factor of fire for steel and side panels of Stainless steel of
sheet of grade 304 duty. Car ceiling will be S.S. finishes with aesthetic appearance with LED ceiling
lights. Car flooring shall be Good quality higher strength aliminium chequred plate/ granite/ pvc flooring(
as per site requirement and instructed by EIC. Car doors shall be of stainless steel grade 304, hairline
finish with centre opening / telescopic automatic doors. Car panel will also be S.S. 304 finished with
emergency stop device, mechanical door safety device, facility of auto/ attended mode. All car panel
buttons and all floor switches must be with brail language as per lift act.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
[4] All landing doors shall be fully automatic centre opening/ telescopic opening made of hairline finish
steel grade of 304 with key holes and infrared curtains with Unlocking facility from outside.
[5] Appropriate battery operated emergency light in the car along with alarm switch shall be provided.
[6] Digital scrolling indicator system for up-down arrow along with floor position indicator shall be provided
inside the car and at all floors.
[7] Full height infra red curtain with multiple criss / crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided accordingly of passenger capacity.
[9] Audio visual indication in the lift car showing over loading shall be provided such that doors kept open
till excess load is removed.
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan and lights with automatic sleep timer shall be provided.
[12] Voice annunciater with suitable music shall be provided in lift car.
[13] Self diagnostics system for operational and safety parameters shall be provided in control panel.
[14] Mechanical over speed governor, door key holes in the floor doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be
provided by the lift agency, along with the other steel structure works, foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided without any extra cost, where ever required as / if
directed by engineer in charge.
[17] Permanent wiring in lift machine room and lift well with proper numbers of light points, with fixtures,
exhaust fan and plug points shall be provided by the agency. Power supply of 3 phase 440 V shall be
made available by department in lift machine room.
[18] Any civil/ electrical works for additional and alteration in lift shaft and machine room related to
erection of lift shall be made by lift agency without any extra cost.(granite/marble fixing around all landing
door openings are not in lift agency’s scope.)
[19]Intercom Suitable For Hook Up To EPBAX
[20] Agency Has To Provide All Working Drawing & Document & Liaison Service For Obtainning All
Necessary Permission From Lift Inspector & Other Authorities.
[21]As Per Statutory Requirement Of Govt Of Gujarat Lift & Escalator Act 2000,Lift Agency Has To
Provide.1.Car Top Safety Barried 2.Push & Talk Communication system 3.Fireman's Switch Operation
At Ground Floor
[22]Including Providing Comprehensive Maintenance Service (Including Spare Parts)During Defect
Liablity Period Complete As Required & As Specified.All Civil Work Carried For Lift Installation Should
Be Done By Contractor .Contractor Shall Arrange All ApprovalForm all Concern Department For Lift. 23 )
Required Capacity of Three Phase Voltage Stabilizer as per Lift OEM Requirement Having Input voltage
Range - 340 to 480 Volt AC and Output Voltage Range 415 Volt AC +-1% ( line - Line ). Voltage
stabilizer must be installed at Machine Room.
24)In this tender agency has to maintain all lift including services and spare parts during defect liability
period as per item inluded in tender. Detail Specification of lIft as per Annexure( Including Duplex system
(25)Lift outer door has male female provision for 2 Hrs fire rated door.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
26) Factory inspection for verification of quality,workmanship and as per drawing & testing before
dispatch the material as per tender condition. 27) Inverter/UPS/Battery for ARD Unit to be covered with
lock and Key Powder Coated Box and fix it to be suitable height on Wall. 28)In machine room; Lift
machine/car rope core cutting, governor rope core cutting, counter weight rope core cutting, traveling
cable core cutting rates are included in this item. No additional payment for core cutting will be paid to the
agency..(29) Lift Panels shall be supplied with Seven Tank chemical process which shall be carried out
before applying painting, painted with powder coating & IP 55 protection and all lift Cables must be
erected in 16 SWG Raceway made from Galvanised. (30) Advanced Control system dual 32 bit
embedded microprocessor with CANBUS serial communication mode operation on site programming
facility , anti nuisance, pre-opening, BMS/ RMS system supporting hardware & Software. False call
Canceling/ Anti Nuisance, (31) As per gujarat lift and escalator act 2001 and central electricity authority
regulations 2010, RCCB for lift cabin and lift machine must be installed in control panel by lift
manufacturer 32)Duplex System rate included in this item.Extra payment for Duplex System will not be
paid to Agency.(a) For 16 passengers (Parking + 11 upper Floor ) with Rated Speed of 2.0/2.5 m/sec
with micro processor /PLC control and ACVVVF.drive Premium Category
460 Executing coprehensive (All in All) service & maintenance(Including replacement of battery For ARD) 3.00 Job 330128.00 RS: Three lac Thirty Thousand
with spare parts as per terms & condition of tender lift manufacture for defect liability period.For that main One Hundred Twenty Eight only
agancy has to give All in All comprehensive maintenance contract to lift manufacturer and copy of this
contract will be submitted before final bill .Agency has to quote rate accordingly.Agency has to also
provide the fitness certificate from lift manufacturer and submit to GSPHCL.Agency has to submit
compulsory FDR of Rs 990384 + GST or quoted amount whichever is higher to GSPHCL. Which will be
releard after successful completion of AMC & at the and of defect liability period.lift OME has to mantain
written record of sevice & maintenance during defect libility daily period duly sign by police dept.and
submited redulary to GSPHCL.Lift agency has to do maintance as per term & Condition altarenet in
tender for delay in rectifing the fault,penalty will be deduced from agency S.D.
461 Supply ,Installation , testing & Commissioning of heavy duty meduim voltage cable as per specficification 250.00 Mtr. 107.00 RS: One Hundred Seven
& IS 7098 part I , 4C X 1.5 SQ.,MM ARMOURED CABLE (CU.) FRLS,RED colour with approved make , only
with require support , cable tie, cable tagging , hardare are etc to complete the work.(As per BIS
462 Supplying and erecting Flexible PVC insulated multistrand multicore 1.1 kv grade ISI marked copper 2560.00 Mtr. 31.00 RS: Thirty One only
wires of following size to be erected as directed.For 1.50 Sq.mm 2 core round PVC sheathed. having
insulation colour RED and BLACK for Fire Alarm System.
463 SITC of Microprocessor based Net-workable Analogue Addressable Fire Alarm Control Panel. The Panel 2.00 Each 93004.65 RS: Ninty Three Thousand Four
shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall and Paise Sixty Five only
have inbuilt one loop. The Panel must have large graphic display. The Panel must also have the
capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall
have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons.
The Panel shall have 240 V AC power supply along with automatic Battery Charger. Non-Networkable
Approved by LPCB (Including Five year free maintenance with guarantee)
464 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector 50.00 Each 2,415.38 RS: Two Thousand Four
having IS-11360-1985 or BS 5446 Part I-1977 & Part VII –1985 (VdS approved) or NFPA72 (UL/ULC/FM Hundred Fifteen and Paise Thirty
approved) with Latest ammendment complete with mounting base complete as required. (Morley / GST/ Eight only
cooper / ASES / HUCHIKI make and model approved by EIC as per specification) [Test certificate must
465 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of 3.00 Each 2,288.25 RS: Two Thousand Two
rise cum fixed tempreature thermistor having IS-2175 - 1988 or BS-5445 (EN 54) Part 5 –1977(VdS Hundred Eighty Eight and Paise
approved) or NFPA72 (UL/ULC/FM approved) complete with base as required. (Morley / GST/ cooper Twenty Five only
ASES / HUCHIKI make and model approved by EIC as per specification) [Test certificate must be
466 Supply, Installation, Testing and Commissioning of Single action Manual Pull Station.Shock and 26.00 Each 826.00 RS: Eight Hundred Twenty Six
Vibration Resistant, Pull Down Lever Remains Down Until Reset. Shall be Polarity Insensitive (with all only
mounting accessories , complete with Junction Box for mooting on Surface, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.) (ASES /ravel/morley or approved by EIC as per Tender
specifications) (Test certificate must be submitted)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
467 Supply, Installation, Testing and Commissioning of Conventional Sounder cum strobe having tone 26.00 Each 826.00 RS: Eight Hundred Twenty Six
settings with range of 95-105 dbA and field selectable 15/30/75/110 candelas, 24 Volt (with all mounting only
accessories , complete with Junction Box for mooting on Surface, Cable lugs at Ends, cable compression
glands, cable tags and Ferruling.) (ASES /ravel/morley or approved by EIC as per Tender specifications)
(Test certificate must be submitted)
468 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box 20.00 Each 150.00 RS: One Hundred Fifty only
having two LED, metallic cover complete with all connections etc and LPCB/ UL / FM approved as
required (Make:GST,Siemens,Morley,Copper, Honeywell)
469 Supply, Installation, Testing and Commissioning of modern 12-ZONE Conventional Fire Detection and 1.00 Each 28501.43 RS: Twenty Eight Thousand Five
Alarm System of an approved manufacture and design, and in accordance with the requirements of BS Hundred One and Paise Forty Two
5839 part 4 and EN 54-2 & 4, and with quality assurance requirements of ISO 9001-1994. The panel only
shall be LPCB approved.
The system equipment shall be CE tested and certified and the CE marking shall appear on the
packaging and/or included in the operating instructions. The control panel shall be housed in a steel
enclosure with partially glazed door. All electronics within the panel shall be microprocessor controlled.
The motherboard and the display electronics inside the control panel shall be fixed on to a detachable
chassis. The panel shall include an integral power supply unit and sealed lead acid batteries(power
backup). A fire relay with two changeover contacts and a fault relay with changeover contact shall be
supplied in the control panel. Facilities for remote evacuation, silence and reset of system shall be
provided. Twin LED's shall be provided for zone identification. They will flash intermittently when an
alarm is received and change to steady when the alarm is acknowledged. A flashing amber fault led shall
indic All zones shall be monitored for both open and short circuit faults, (ASES /ravel/morley or approved
by EIC as per Tender specifications) (Test certificate must be submitted)
470 Providing and fixing of ABC Type Store Pressure Fire Extinguisher Having capacity 6 kg Filled with 22.00 Each 1991.00 RS: One Thousand Nine Hundred
Mono Ammonium Phosphate Powder 50% confirms to IS 4308, Stored Pressure Type, UGTS Pressure Ninty One only
Gauge, Can Height 530 mm, Diameter 150 ± 10mm, Discharge Time 24 Sec, Controllable discharge
mechanism, Jet Range 5 Meters, Average Discharge is 92%, applicable on Class A,B & C and
electrically started Fire, Fire Rating 4A:144B, Can Construction : Deep drawn & CO2 Mig welded,
EPDM(Ethylene Propylene Diene Monomer) Rubber Hose with both end Aluminum clamped, Internal
Coating - Epoxy Powder coating, External Coating - Pure Polyester Powder coating (UV Resistant),Brass
forged CE Marked valves with NRV & Auto Safety Release with safety Pin is of SS material, Made up
from 1.6mm thick sheet, Extinguishers confirmed to IS 15683:2018 and ISI marked. Referance Weight:-
Gross Weight 8.9 Kg, Empty Weight 2.9 Kg, 1. Necessary certificate & and guarantee must be attached,
2. OEM has to provide wall mounting heavy duty bracket/clamp, screw, hardware for installation.
3.Following printed marking Manufacturing Date and Expiry Date must be mention on Extinguisher
Refilling period must be of 3 Years. Following Printed marking on equipment must be required:- Model
No, Capacity, Gross Weight, Content, Fire Rating, Batch No, Serial no, Mfg Month, Refilling Due. [with
necessary numbering / marking with oil paint by painter as instructions given by G.S.P.H.C.L engineer]
(Make: KANEX, MINIMAX,CEASEFIRE)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
471 Providing and fixing of CO2 type High Pressure Portable 4.5 kg Fire Extinguisher, filled with Co2 Gas as 22.00 Each 6526.00 RS: Six Thousand Five Hundred
per IS 15222, Control discharge mechanism fitted with 1 Meter Wire Braided Hose & Electrical non- Twenty Six only
conductor Polyethylene Flat Horn with Diffuser Nozzle for dispersed discharge of CO2, Discharge Time
12 Sec, Average Discharge is 95%, Applicable on Class B, C and electrically started Fire, Fire Rating
55B, Internal coating is not applicable & External coating is of enamel spray painting, Powder Coated
Handle, Valve Confirm to IS 3224 ISI Marked, CO2 Cylinder construction: hot spinning by seamless
pipes & bearing ISI mark, Body confirms to IS 7285 and PESO ( Petroleum and Explosives Safety
Organization) APPROVED, Minimum Wall Thickness 4 to 4.2 mm, Extinguishers confirmed to IS
15683:2018 and ISI marked. Referance Weight:-Gross Weight 16.4, empty weight 11.9 Kg,
Necessary certificate & and guarantee must be attached, 2. OEM has to provide wall mounting heavy
duty bracket/clamp, screw, hardware for installation. 3.Following printed marking Manufacturing Date
and Expiry Date must be mention on Extinguisher 4. Refilling period must be of 5 Years. Following
Printed marking on equipment must be required:- Model No, Capacity, Gross Weight, Content, Fire
Rating, Batch No, Serial no, Mfg Month, Refilling Due. [with necessary numbering / marking with oil paint
by painter as instructions given by G.S.P.H.C.L engineer] (Make: KANEX, MINIMAX,CEASEFIRE)
472 Providing and fixing of Automatic type 5 kg Fire Extinguishers Mono Ammonium Phosphate powder 2.00 Each 5240.00 RS: Five Thousand Two Hundred
50% Confirms to IS 4308, Applicable fire classes A,B & C, UGTS Pressure Gauge, Can Height 370mm, Forty only
Diameter 230 ± 10mm, Made up from 2 mm thick sheet, Body Construction Deep Drawn with MIG
Welding technology, Brass forged sprinkler valves with Nozzle is specially designed to give more than
99% discharge. Together with orifice characteristic to cover adequately fire risks with scattering cone of
40 to 45° Angle. External Pure polyester (UV resistant) and Internal Epoxy polyester powder coated, Heat
Sensitive Glass bulb of 68 °C. Area covered will be 2-2.5 m2 and volume of coverage is 7 m3.
Referance Weight:-Empty Weight 2.64 kg, Full weight 7.64 kg, 1. Necessary certificate & and
guarantee must be attached, 2. OEM has to provide heavy duty wall/ Ceiling mounting Bracket/ clamp,
screw, hardware for installation. 3.Following printed marking Manufacturing Date and Expiry Date must
be mention on Extinguisher 4. Refilling period must be of 3 Years. Following Printed marking on
equipment must be required:- Model No, Capacity, Gross Weight, Content, Fire Rating, Batch No, Serial
no, Mfg Month, Refilling Due. [with necessary numbering / marking with oil paint by painter as instructions
given by G.S.P.H.C.L engineer] (Make: KANEX, MINIMAX, CEASEFIRE)
473 Providing printed instruction chart both in English and Gujarati and duly framed with front glasses, for 2.00 Each 129.00 RS: One Hundred Twenty Nine
treatment of person suffering from Electric shock only
474 Supplying, Installation, Testing & commissioning of Electric driven Main Fire Pump suitable for automatic 1.00 Each 341037.00 RS: Three lac Forty One Thousand
operation and consisting of following, complete in all respects, as required: (a) Horizontal type, Single Thirty Seven only
stage, centrifugal, End Suction Long Coupled Pump of cast iron body & bronze impeller with stainless
steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC,
synchronous speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP
protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)
Suitable Cement Concrete Foundation duly plastered with anti vibration pads. (e) cost include foot valve
of suitable size CI body heavy duty. (f) Discharge :- minimum 2280 LPM Note: The head of the pump
shall be selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.
Note: The head of the pump shall be selected in a manner so as to give a minimum 3.5kgf/cm2 pressure
at the highest/farthest point. Agency has to calculate the total head required for getting minimum
3.5kgf/cm2 pressure at the farthest & highest point of building of wet riser fire system. For that agency
has to calculate total pump head by considering vertical head ( Total Building height+ Sump
depth+3.5kgf/cm2 pressure & Total equivalent vertical head due to frication losses of total length of pipe
+ bend number, Elbow number, Tee, Valve etc.) Agency must have to select pump model having
required head & discharge( asper fire department rules) at duty point. No Extra payment shall be done
for head variation due to site situation & fire rules. The panel shall be design according to motor H.P
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
475 Supplying, installation, testing and commissioning of Diesel engine driven Main Fire Pump suitable for 1.00 Each 565040.00 RS: five lac sixty five Thousand
automatic operation and consisting of following, complete in all respects, as required: [Diesel driven Fourty only
(a) Horizontal type, Singlestage, centrifugal, End suction Long Coupled pump of cast iron body & bronze
impeller with stainless steel shaft, mechanical seal conforming to IS
(b) Suitable HP 2900 RPM water cooled with radiator diesel conforming to relavant IS standard complete
with auto starting mechanism 12/24 Volts electric starting equipment, diesel tank, exhaust pipe extended
upto 10 M outside pump house duly insulated with 50 mm thick glass wool with 1.00 mm thick aluminium
sheet cladding, residential silencer, instrument and protection as per standard specification, stop
solenoid for auto stop in the event of fault with auto indications painted with post office red color etc. as
(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
(d) Suitable cement concrete foundation duly plastered with anti vibration pads.
(e) Cost include providing, erecting req. size copper XLPE Armound cable with GI cable tray, support etc.
as per EIC instruction (app. cable lenth 15 mtr.)
(f) Cable from pump to panel will be laid in cable tray or fixed on G.I./M.S. strip / channel as per
instructions given by EIC as per site requirement.
(g)Cost include foot valve of Suitable size CI body heavy duty (SANT,Kirloskar, Kartar, Zoloto make)
(h)Discharge:- minimum 2850 LPM. Note: The head of the pump shall be selected in a manner so as to
give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.
[The all require Technical specification & Test certificate shall be submitted to Local fire Authority for
(Factory inspection will have to carried out by agency with G.S.P.H.C.L. engineer)
476 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable 1.00 Each 113709.00 RS: One lac Thirteen Thousand
for automatic operation and consisting of following, complete in all respects, as required: (Jockey Seven Hundred nine only
(a) Horizontal type, Singlestage, centrifugal, End suction Long Coupled pump of cast iron body & bronze
impeller with stainless steel shaft, mechanical seal conforming to IS
(b) Suitable HP Squirrel cage induction motor, TEFC type suitable for operation on 415 volts,
phase, 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with
Class-'F' insulation,conforming to IS :
(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
(e) Required size 3 core flat cable from pump to panel for connection should be provided with pump.
(f) Cable from pump to panel will be laid in cable tray or fixed on G.I./M.S. strip / channel as per
instructions given by EIC as per site requirement.
(g) Cost include foot valve of suitable size CI body heavy duty.(SANT,Kirloskar, Kartar, Zoloto make)
(h) Discharge:- minimum 180 LPM.Note: The head of the pump shall be selected in a manner so as to
give a minimum 3.5kgf/cm2 pressure at the highest/farthest point
(Factory inspection will have to carried out by agency with G.S.P.H.C.L. engineer)
477 Fabrication, supply, installation and commissioning of electrical control panel of cubical construction, 1.00 Each 217623.00 RS: Twenty one lac Seven
floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalised with hinged locable Thousand Six Hundred Twenty Three
doors, dust and vermin proof, power coated of approved shade after 7 tank treatment process, cable only
alley, inter connection with suitable size copeer conductor cable/solid copper strip having switchgear and
accessories, mounting and internal wiring, earth terminals, numbering etc. complete in all respect
suitable for main fire pump, pressurisation pump and diesel pump set complete as per specification with
following incoming and outgoings suitable for operation on 415 V, 3 phase 50 Hz AC supply with
enclosure protection class IP 42 as required.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
up to 250A ( As per pump full load current & starting current .) (Approved by EIC), 50 KA 4 Pole MCCB
Ics=100% Icu rating.
Digital voletmeter 0-500 V with selector switch
Digital ammeter 0-250 A with selector switch and CT's etc.
LED type RYB phase indicating lamp, ON, OFF, TRIP indicationg lamps.
Set of copper busbar 300 A.
[Note:- All outgoing feeder for pumps should have digital ammeter with selector switch and LED type ON,
OFF and TRIP indicating lamps.)
MAIN FIRE PUMP:
160 A ( As per pump full load current & starting current .) (Approved by EIC) 50kA TPN MCCB Ics=100%
Icu with fully automatic star/delta starter suitable for 60 HP pump with overload protection current sensing
type single phase preventor complete with all accessories and internal wiring required for automatic
operation, selector switch for local/remote, auto/manual/OFF operation.
63 A 50kA TPN MCCB Ics=100% Icu with suitable HP fully automatic Star/Delta starter with overload
protection, current sensing type single phase preventor complete with all accessories and internal wiring
required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL
ENGINE CONTROL:
1) Automatic/Manual selector switch and 3 attempt starting device, timers and relay as required, push
buttons, start/stop in manual mode.
2) Indicating lamp for high/low lub oil pressure, high water temperature and engine ON indication.
3) Battery charger suitable for 12/24 V DC with boost and trickle selector switch 0-30 V DC Volt meter
and 0-20 A DC Ammeter.
4) All standard relays and accessories for autoamtic operation of diesel engine.
SYSTEM CONTROLLER:
Design, supply, installation, testing and commissioning of system controller to control operation of main
electric fire pump, Pressurisation (Jockey) Pump, Diesel pump and terrace pump in sequence as per
specification consisting of relays, timers, sensors, annunciation window for fault indication complete as
per specification.
478 Providing and fixing of Dial type Pressure Gauge having 100 mm dial & range of 0-14 Kg/cm2 with 8.00 Each 1539.46 RS: One Thousand Five Hundred
isolation ball valve. (Make:- Hguru, Fiebig,General Instrument) (Test certificate must be submitted) Thirty Nine and Paise Forty Six only
479 Providing and fixing of Pressure switch with Needle valve ( Indfos,Honeywell,System Sensor make and 8.00 Each 1310.00 RS: One Thousand Three
Model Instruct by EIC (Only) Hundred Ten only
480 Providing and fixing of Air Release Valve including Ball Valve 25 mm dia. (Approved ISI make & model 4.00 Each 1601.00 RS: One Thousand Six Hundred
approved by EIC strictly as per specification) One only
481 Supply, Installation, Testing and Commissioning of Pump On-Off switch (with all mounting accessories , 12.00 Each 890.00 RS: Eight Hundred Ninty
complete with Junction Box for mooting on Surface, Cable lugs at Ends, cable compression glands, only
cable tags and Ferruling.)for remote operation from each floor of the building. (Approved by EIC) (Test
certificate must be submitted)
482 Supplying and fixing air vessel (pressure vessel) made of 250 mm dia, 8 mm thick MS sheet, 1200 mm 1.00 Each 16442.15 RS: Sixteen Thousand Four
in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Hundred Forty Two and Paise
gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel Fifteen only
paint of approved shade as required. (Approved ISI make & model approved by EIC) (Test certificate
must be submitted)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
483 Executing comprehensive (All-in-All) service & maintenance with spare parts as per terms & condition of 1.00 Per Tower 77624.00 RS: seventy seven thousand six
tender for Fire terrace pump with fire hydrant agency for defect liability period and copy of this contract hundred twenty four only
will be submitted before final bill. Agency has to quote rate accordingly. Agency has to also provide the
fitness certificate from system agency and submit to G.S.P.H.C.L. Agency has to compulsory submit
FDR of Rs.77624.00+GST or quoted rate whichever is higher to G.S.P.H.C.L,for minimum maturity
period of Four years in favour of G.S.P.H.C.L Which will be released after successful completion of
A.M.C. & at the completion of defect liability period. Fire System agency has to maintain written record of
service & maintenance during defect liability period duly sign by police dept. and submit regularly to
G.S.P.H.C.L. Agency has to give minimum three services and demonstration per year and testing and
training of pump during defect liability period and obtain necessary certificate from police department and
submit to G.S.P.H.C.L. Agency has to do maintenance as per terms & condition alternative in
tender.Agency has to give One live demonstration of fire Mock drill for fire fighting with minimum 01 no.
CO2 and 01 no. ABC type fire extinguisher at the time of handing over this system to the Police
department and another at the time of releasing final Security deposit. The necessary certificate /
photographs for that must be submitted.
484 Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar Power Plant with Solar 20.00 PER KW 40256.00 RS: Forty Thousand Two
Panels (ALMM approved): Frame Material : Anodized Aluminum alloy Frame With Twin Wall Profile, Hundred Fifty Six only
Front Cover : High Transmission Low-Iron Tempered Glass (AR Coated), High efficency and positive
power tolerance Pmax: 0/+5, Module Efficiency should be approx. 18%-21%, Normal operating
temperature 45'C, Junction Box with Waterproof IP67 & MC4 Compatible and Enclosed with Bypass
diodes, 100% Electroluminescence test to ensure error free Modules, Thep. temp. co-efficient of the PV
module shall equal or better than -0.45%/degree C. Solar PV modules of minimum fill factor 75% to be
used. Unit Production:- 4 to 5 Unit /kw /day (Actual)(1Year Avg) With 10 year Product warranty and
year Linear Power Warranty.,
Solar Inverter: MPPT Range: 80-1000 V, Max efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz,
Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%, Operating Tempreture Range: -
25~60°C, Anti-islanding Protection:
Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor Detection Integrated,
Residual Current Monitoring Unit Integrated, Output Over Current Protection Integrated, Output Short
Circuit Protection Integrated, Output Over Voltage Protection Integrated, Protection Degree: IP65, User
Interface LCD & APP,Datalogger & Communication: GPRS / Wi-Fi, Module Mounting Structure:
Seamless Box Pipe / 'C' Channel of suitable size for rooftop solar installations with good stability agaist
wind & weight load., Hot Dipped Galvanized steel coils. suitable arrangement for base plate for
foundation , solar panel mounting, the structure should be suitable for carry the load of solar panel,wiring,
sprinkler system etc. with necessary foundation work/wall mount, j bolt, anchor fastner etc. the nut bolt
used for installtion of stucture should be (SS 304) quality. and Balane of System with necessary
Swithgears (Suitabel size and protection of ACDB & DCDB), inter connecting wiring, earthing system,
lightining arrester system, all liasoning work with various gov. department like state nodal
agency,DISCOM & CEIG is included in agency scope
(E) Grid Tied Solar Power System: 40 kW (3 - phase)
Note 1: Fabrication design drawing shall be approved by structure consultant W.R.T Wind velocity and
weight of panel.Height of Structure shall be decided by GSPHCL & Beneficiearies.So maintenance of
terrace water proofing and easy access to all.Foundation and Anchor Bolt erection must be such as to
avoid water leakage from slab .Civil & Electrical Agency and GSPHCL Civil engineer have to decide the
methodology ation of foundand work should be carried out under supervision of GSPHCL Civil Engineer
Note2: Capacity of Solar Panel in Tender is approximately .Engineer In Charge(EIC) can increase ane
decrease the capacity in KW as per site requirement.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Note3: Any Subsidy received by the government towards the cost of solar roof tops will have to diposited
in the GSPHCL.Keeping this in mind, the agency will have to quote the rate in the tender.
485 Executing Com of solar Pv Modules, Inverter, wiring,earthing,switchgears, etc with material and labour 20.00 PER KW 7628.00 RS: Seven Thousand Six
cost including preventive maintanance.The cost covers entire installation. AMC also includes monthly Hundred Twenty Eight only
site visit and inspection of project with submission of inspection and solar generation report. All parts
should be replaced/repaired if found faulty within specified time. Agency has to provide necessary
liasoning work for warranty,power,Bidirectional meter etc of following Capacity as per terms & condition
of tender for defect liability period.Agency has to submit FDR of approved bank as per clause
section 3 Rs 152560.00 + GST or quoted rate which ever is higher to GSPHCL,for minimum maturity
period of four years in favour of GSPHC .Which will be released after succesfull completion of AMC & at
the end of defect liability period.Solar Agency has to maintain record of service & maintenance during
defect liability period duly sign by Benificiaries and submitted regularly to GSPHCL & also get satisfactory
certificate from beneficiaries at the time of Defect liability period and copy of maintenance contract must
be submitted during final bill. (D) For 40KW system
486 SITC of 8 mm dia solid Aluminium Conductor for roof top mesh grid and tested as per IEC 62561 2 350.00 Meter 297.00 RS: Two Hundred Ninty Seven
conducted in the Govt. accredited thirty party laboratory to meet the requirement of IS/IEC 62305 with only
Required Accessories Aluminium/Polyamide Holding clamp at every 500mm distance, Aluminium/SS
cross splicer at every crossing of Alu. conductor, Expansion piece with connectors at every 20 mtr
distance, Aluminium straight Splicer to connect conductors. All Accessories should be tested as per IEC
62561 1 2018 Cl. 6.3 for conditioning and Ageing Test and 6.4 for Lightning impulse current withstand
test: 100 kA of 10/350µs waveform(Ageing and Electrical test ) conducted in a sequence manner and
tested in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 6230 and item
including necessarary installation arrangement like julla, H Frame etc (OBO, JEF, CAPE, DHEN make
487 SITC of Vertical Air Termination Solid aluminium with Base 10 mm dia and 1000 mm long. Air 4.00 Nos. 9323.00 RS: Nine Thousand Three
Termination Base tested for conditioning, Ageing Test and Lightning impulse current withstand test: 100 Hundred Twenty Three only
kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 and 6.4 of IEC 62561 1
protocol with MAST 34mm dia 3000 mm long Cold Galvanized with base plate, anchroning bolts,
supporting stray insulated GI rope wires minimum three sides, CC foundation etc. complete as required,
as per site conditions and approved by the Engineer In Charge and Aluminium Wall clamp . (height may
please be considered keeping in mind the maximum height required after installation of communication
towers of police department). (OBO, JEF, CAPE, DHEN make only )
488 SITC of Vertical Air Termination Solid aluminium with Base 10 mm dia and 1000 mm long. Air 4.00 Nos. 3108.00 RS: Three Thousand One
Termination Base tested for conditioning, Ageing Test and Lightning impulse current withstand test: 100 Hundred Eight only
kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 and 6.4 of IEC 62561 1
protocol with Aluminium Base (OBO, JEF, CAPE, DHEN make only )
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
489 SITC of 10 mm MS insulated/ Caoted Round Solid Conductor having smooth surface Should be tested 900.00 Meter 721.00 RS: Seven Hundred Twenty
and use exclusively for lightning protection (Vertical Riser/Down Conductor which shall be concealed in One only
Column) to meet the requirement of IS IEC 62305 With Accessories Earthing stud of dimension SS
75mm OD plate with 10mm dia tail connector used in structural steel ring earthing system to meet the
requirements of IS/IEC 62305. (For Interconnecting the Column and the Terrace AL Conductor /
Strip/Flat), SS Cross Connector to connect Earth fixing point to vertical raiser/Down conductor, SS
Straight Splicer at every 4 Mtr to connect MS conductor in column, Bonding /Rebar Clamp at every 3 mtr
suitable for interconnecting round conductor with reinforcement inside the concrete for structural earthing
system, SS connector To connect external conductor 8 10 mm with earth fixing point. All Accessories
should be tested as per IEC 62561 1 2018 Cl. 6.3 for conditioning and Ageing Test and 6.4 for Lightning
impulse current withstand test: 100 kA of 10/350µs waveform(Ageing and Electrical test ) conducted in a
sequence manner and tested in the Govt. accredited Third party laboratory to meet the requirements of
IS/IEC 6230(OBO, JEF, CAPE, DHEN make only )
490 SITC of Lighting counter To count no of lightning strike and it can record the date and time of the 2.00 Nos. 22137.50 RS: Twenty Two Thousand One
lightning having plastic encloser IP 65. Measuring Range: 0 100 KA, Display: LCD with 0 999 count, Hundred Thirty Seven and Paise
operating temprature: 20 to 60 degree celcius, No odsensor:1 nos (OBO, JEF, CAPE, DHEN make only Fifty only
491 SITC of Galvanized Steel Flat 25x6 mm thickness from earth electrode directly in ground as required. 205.00 Mtr. 153.00 RS: One Hundred Fifty Three
Zinc coating: 500 g/m square (Approx:85 micron coating) tested and used exclusively for lightning only
protection earthing system and ring equipotential bonding.( Only For Lightning Arrestor) (OBO, JEF,
CAPE, DHEN make only )
492 SITC of 14.2 mm dia 3 mtr long Earth electrode of High tensile steel electrode with 250 micron copper 8.00 Nos. 5933.00 RS: Five Thousand Nine Hundred
bonding and 2 bag of Carbon fill Based environment friendly backfill tested as per IEC 62561 7 in NABL Thirty Three only
accredited Laboratory and suitable stainless Steel double sided clamp. Chamber and cover : Earthing
chamber should be size of 400mmX400mmX400mm depth and Cover should be heavy duty cast iron
with required size of 300mmX300mmX4mm thick..( Only For Lightning Arrestor)(OBO, JEF, CAPE,
DHEN make only )
493 Supplying, installation, testing & commissioning of LED Aviation light with red color poly carbonate dome 2.00 Nos. 4812.00 RS: Four Thousand Eight Hundred
luminaries including required driver/ control box, protections, above the highest point of terrace level and Twelve only
making good the same. It should switch ON automatically as required in night time & OFF in day time
including FRLS copper control wiring etc. complete in all respect as required & as approved by the
Engineer Incharge. (fixing height may please be considerd as per the site requirement)
TOTAL CIVIL AMOUNT=
TOTAL ELECTRICAL AMOUNT=
TOTAL CIVIL + ELECTRICAL AMOUNT=
CONTRACTOR SIGN
Dy.Exe. Engineer Exe. Engineer
Ahmedabad. Ahmedabad.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ALL CONDITIONS BODAKDEV.pdf
approved make list.pdf
BODAKDEV ATTACHED SPECIFICATIONS.pdf
BODAKDEV SBD VOLUME 1.pdf
BODAKDEV SBD VOLUME 2.pdf
BODAKDEV SBD VOLUME 3.pdf
BODAKDEV SBD VOLUME 4.pdf
CEMENT CONSUMPTION BODAKDEV.pdf
COMBINED SCHEDULE B BODAKDEV.pdf
Condition of RMC.pdf
DMO_2941_01-Apr-2026_744.pdf
E1-20 BODAKDEV ARC. DRW (1).pdf
E1-DTP ELE-E1-20-Bodakdev-UPLOAD.pdf
E2-ELE. COND-E1-20 Bodakdev-UPLOAD.pdf
E3-Ele. Spec. Booklet-UPLOAD.pdf
Genral Techinal Specification B S BOOK_ 24-3-23.pdf
Special Condition.pdf
STANDARD SPECIFICATIONS BODAKDEV.pdf
STRUCTURAL DRW-compressed 1.pdf
STRUCTURAL DRW-compressed 2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .