| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | L1 | Accepted-AOC Admitted | |
| 2 | L2₹27.9 L+₹44,461 (1.62%)Rejected-Finance 204B SENTHAMANGALAM GOTHANDARAMPURAM VILLAGE PERUMANADU POST VAYALOGAM VIA PUDUKKOTTAI DIST TN | PUDUKKOTTAI | TAMIL NADU | 622104 | L2 | Rejected-Finance Not Being lowest tenderer | |
| 3 | L3₹28.8 L+₹1.3 L (4.82%)Rejected-Finance | L3 | Rejected-Finance Not Being lowest tenderer |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
6 Oct 2023, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
COMPREHENSIVE MAINTENANCE INCLUDING REPAIRS TO JOINERY WALL FLOORING AND PERIODICAL SERVICES OF OTM AND MD ACCN AND REPAIRS AND CLEANING OF SEPTIC TANK SOAKAGE WELL SEWAGE LINES MANHOLES AND REPAIRS TO FENCING COMPOUND WALLS GATES PARKING SHED RETAIN
2023_MES_618548_1
8821/E8
Open Tender
Civil Works
Item Rate
180 days
Trichy
As per Tender Documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹59,000
Yes
14 Nov 2023
13 Sept 2023
12 Oct 2023
14 Sept 2023
6 Oct 2023
22 Sept 2023
Amount
Taking down chowkats or frames not exceeding 1.5 Sqm each with shutters (without taking off shutters from the frames) all as specified and directed.
All as per item No. 01 above, but exceeding 1.5 Sqm and not exceeding 4 Sqm each all as specified and directed.
Taking down shutters of any description exceeding 2 Sqm each all as specified and directed.
Taking down shutters of any description exceeding 1 Sqm and not exeeding 2 Sqm each all as specified and directed.
Taking down shutters of any description not exceeding 1 Sqm each all as specified and directed.
2nd class hard wood wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue, pinned at joint all as specified and as directed.
2nd class Hard wood 35 mm thick Glazed and skeleton shutters, open rebated prepared to receive glass/gauze etc. edges of framing, divided in to squres with plain chamfered or rounded, fitted with cut mitered beads for securing glass/gauze all as specified and as directed. Note: Glazing and gauze will be measured separately all as specified and directed
2nd class Hard wood 35 mm thick framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and as directed.
30mm thick second class hardwood glazed and skeleton door shutters open rebated and prepared to receive glass, gauze etc, (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, sizes of members of shutter as specified in SSR Part-I section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
30 mm thick flush shutter,solid core construction, with block Board Core and plywood face panels, commercial type on both sides complete all as specified and as directed.
Solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain color PVC sheet reinforced with MS Square tube, fixed in opening all as specified and as directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame out of MS tube for top and bottom rails. MS frame shall be covered with heat molded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width struck in side with solvent cementall as specified and as directed.
Providing plain cement concrete 1:3:6 Type C0 (using 12.50 mm graded stone aggregate) as in bed blocks of hold fast etc complete including necessary formwork all as specified and directed.
Butt hinges, 100 mm size medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
Butt hinges extruded Aluminium alloy with galvanized mild steel hinge pin, anodized and fixed, type C-21, with MS hinge pin 100mm size all as specified and directed.
Butt hinges medium weight cold rolled mild steel 75mm long complete all as specified and directed.
Aluminium anodized barrel tower bolt of extruded section 150mm length all as specified and directed.
Aluminum anodized barrel tower bolts of extruded section 100 mm long all as specified and directed.
Aluminum anodized barrel tower bolts of extruded section 75 mm long all as specified and directed.
Aluminum handles, fabricated type ,anodised extruded section 150 mm long all as specified and directed.
Aluminum handles, fabricated type ,anodised extruded section 100 mm long all as specified and directed.
250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel pin fixed to door of 140mm overall length all as specified and directed.
Single action spring hinges mild steel wire spring, stove enamelled, black complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless wire staples complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless wire staples as in repairs to steel / wooden joinery complete all as specified and directed.
Ground or frosted 4 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.5 sqm in each pane complete all as specified and directed.
4 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.5 sqm in each pane complete all as specified and directed.
Plain sheet glass 4.0mm thick ordinary quality and glazing with oil putty in square exceeding 0.5 Sq.m in each pane complete all as specified and directed.
Fancy type Steel PVC Coated, drapery rod of size 20-25mm dia, including fixing of Steel powder coated fancy brackets & end stops 2 Nos in Each opening etc complete all as specified and directed.
Preparation of new wood surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
12 mm thick Prelaminated termite resistant water proofing plywood interior grade, Prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work , fixed in repairs complete all as specified and directed.
18 mm thick Prelaminated termite resistant water proofing plywood interior grade, Prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work , fixed in repairs complete all as specified and directed.
Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
4.8mm thk sheet glass., ordinary quality and glazing with oil putty / rubber beading in square but exceeding 0.5 Sqm in each pane all as specified and directed.
Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed all as specified and directed.
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as specified and directed.
Health faucet (Jet Spray), CP 15mm dia with flexible pipe and fixing nut etc complete fixed in repairs complete all as specified and directed.
PVC valveless, syphonic action type flushing cistern, low level, 10 litres capacity, white, with inlet, ball, valve, float and handle including brackets fixed in repair complete all as specified and directed.
Stainless steel sinks with drainage board 1mm thick with plugs, washers and waste; incl bedding in cement mortar on to dwarf walls, or including fixing cantilever brackets and connecting union to waste pipe, overall size 915mmx460mm, bowl size 410 x 330 x 160mm, fixed in repairs complete all as specified and directed.
Chromium plated shower rose with or without swivel joint,100 to 125mm size, including fixing to steel pipe or union, fixed in repairs complete all as specified and directed.
Vitreous china wash basin, white, flat back, size 550 x 400mm including brackets, brass waste cupling but excluding pillar tap waste pipe and PVC connection complete, including fixed in repairs complete all as specified and directed.
Vitreous china wash basin, white, flat back, size 450 x 300mm including brackets, brass waste cupling but excluding pillar tap waste pipe and PVC connection complete, including fixed in repairs complete all as specified and directed.
Vitreous China squatting pan, ‘Orissa’pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe), but including P trap/ S trap etc complete fixed in repairs all as specified and directed.
Vitreous China Wash down water closet pan (Pedestal pattern), white (excluding flushing cistern and flush pipe) complete fixed in repairs including all necessary accessories all as specified and directed.
15mm dia bore bib taps of cast copper alloy fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs all as specified and directed.
Pillar taps, fancy type, 15mm dia cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe including fixed in repairs complete all as specified and directed.
Angle valves, 15mm dia,fancy type chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs complete all as specified and directed.
Stop valves, 15mm dia for shower rose, fancy type chromium plated cast copper alloy,with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs complete all as specified and directed.
20mm dia Gunmetal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed.
32/40mm dia expandable type PTMT waste pipe for Wash hand basin/ kitchen sink and fixed in repairs complete all as specified and diercted.
25mm dia Gunmetal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed fixed in repairs complete all as specified and diercted.
PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and diercted.
15mm dia chromium plated cast copper alloy fancy type, two in one combination of bibtap and angle valve fixed in repairs complete all as specified and diercted.
Taking up or down steel tubing and connections, bore of pipe 15 mm all as specified and diercted.
Supply and laying 20mm of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and diercted.
Taking up or down steel tubing and connections, bore of pipe 20 mm all as specified and diercted.
Supply and laying 25mm of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and diercted.
Dismantling water tanks capacity exceeding 250 ltrs and not exceeding 500 ltrs and returned to stores all as specified and diercted.
Dismantling water tanks capacity exceeding 500 ltrs and not exceeding 1000 ltrs and returned to stores all as specified and diercted.
Rotational moulded polyethylene water storage tanks, ISI marked (cylindrical vertical with closed top) hoisted and fixed in position, 500 ltrs capacity complete all as specified and diercted.
Rotational moulded polyethylene water storage tank, ISI marked of capacity 1000 ltrs hoisted and fixed in position complete all as specified and diercted.
PVC (SWR) 110mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and diercted.
PVC (SWR) 75mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and diercted.
Demolition of wall and ceiling boards (fibre pulp, insulation, etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and diercted.
False ceiling using GI snap grid system with roll-formed out of hot-dip galvanised steel capping (powder coated), main runner 38x24mm, cross Tee 29x24mm and wall angle 24x24mm and thickness not less than 1 mm, members suspended with Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long , with 4mm thick designer ceiling board of any texture (Lake & hill, Oceanic, cascade or Electra) as approved by GE, all as per Everest Ceiling grid system "Regular T-2430" or its equivalent make of "Ramco/ Charminar/ Armstrong" complete all as specified and diercted.
CP tubular towel rail 20 mm dia, D type, 60cm long between flanges and fixed in repairs complete all as specified and directed.
Brackets for towel rail complete all as specified and directed.
Preparing old decorated surfaces of walls (plastered or unplastered) including cornices and pillasters and applying one coat of white washing complete all as specified and directed
All as per item No. 69 above but on ceiling surfaces complete all as specified and directed
All as per item No. 69 above but one coat of colour wash complete all as specified and directed
Preparation of old treated surface of any description over 10 cm girth or width not other wise described and applying one coat of cement base paint on wall surfaces complete all as specified and directed .
applying one coat of wall care putty to cover old uneven plastered surfaces in wall/ceiling upto 1mm to cover undulations and finished even and smooth using emery paper all as specified and directed .
Applying one coat of oil bound distemper on old deorated plastered surfaces of walls including preparation of surfcaes and filling holes and undulations with wall putty all as specified and directed.
Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc all as specified and directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces of walls, finished even and smooth (without using extra cement) complete all as specified all as specified and directed.
Rendering 5mm thick in cement mortar 1:3 on concrete surfaces of ceiling finished even and smooth (without using extra cement) complete all as specified
Preparation of new plastered wall surface and applying two coat of cement base paint over a alkali resitant primer on wall surfaces complete all as specified and directed .
Applying three coats of whitewash in ceiling on newly palstered surfaces all as specified and directed
Preparation of new plastered wall surfaces and applying two coats of oil bound distemper over a priming coat using chalk whiting, complete all as specified and directed
Complete removal of existing treatment on walls, chalk whiting and applying two coats of oil bound distemper on old plastered surface all as specified and directed.
Complete removal of existing treatment on walls and applying two coats of cement base paint on old plastered surface all as specified and directed.
Preparation/removal of old treatment of plastered/ stone/brick wall surfaces and applying two coats of Exterior Emulsion Paint ( Anti Fungal) white or tinted complete all as specified and as directed. Note:1. Rates shall be quoted with required scafolding for a height upto 10 meter buildings.
Preparation of old treated/ untreated wall surfaces and applying one coat of Exterior Emulsion Paint ( Anti Fungal) white or tinted complete all as specified and as directed. Note :1. Rates shall be quoted with required scafolding for a height upto 10 meter buildings.
Preparation of old painted wooden surfaces exceeding 10 cm with or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparation of old painted steel surfaces exceeding 10 cm with or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Writing letters or figures (Block, Roman, Italic or indian) not exceeding 30cm height all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed.
sunken floor treatment by providing injection pressure grouting treatment using cement slurry mixed with grout admixtures non shrink additive using 40 PSI pump complete and applying two coats of brush bond acrylic polymer modified cement based coating thickness 1mm or two coats of pidifin 2K acrylic polymer water proof coating including necessary surface preparation , providing 20mm thick water proofing screed bed /plaster in CM 1:4 mixed with conplast x 42IC @ 100ml or Pidiproof LW @ 200ml per bag cement. Two coats of Nitro proof 100 bitumen based water proofing over plastered surface complete all as specification of chemical resistant coating complete all as specified and directed. Note: The work shall be executed through authorised applicator of M/s FOSROC/Pidilite using the materials supplied by M/s Fosroc chemicals India Pvt ltd or M/s Pidilite industrial Ltd and in accordance with their respective manufacturers instructions.
100mm thick lime concrete with lime mortar 1:3 mix and 40 mm graded brick coarse aggregate in sub-floors complete all as specified and directed.
Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cement mortar 1:6 complete all as specified and directed.
Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Glazed ceramic tiles (300x200)x 6-7mm thick, as in skirting/ dado set and jointed in neat cement slurry and pointed in coloured cement to match colour of the tile complete all as specified and directed.
Backing coat /screed 10mm thick in cement mortar 1:4 on fair faces of brick/ stone wall surfaces complete all as specified and directed.
Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 including cement 25 mm thick concrete type B1 1:2:4 (20mm graded aggregate) complete all as specified and directed.
Demolition of brick work or stone/boulder/block masonry built in cement mortar, including all quoins, arches, pillars, etc complete all as specified and directed.
Pre-cast cement concrete block masnory with solid block exceeding 10cm in width and setting in cement mortar 1:4 type C1 1:3:6 using 20mm graded stone aggregate all as specified and directed.
Brick work with sub class B bricks straight or curved in plan exceeding 6m mean radius built in cement mortar 1:4 all as specified and directed.
SEWAGE WORK Demolition of brick work or stone/boulder/block masonry built in cement mortar, including all quoins, arches, pillars, etc. all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors n.exceeding 15cm thickness (below or above ground level) all as specified and directed.
Dismantling of Wrought iron or Mild steel work of any description not otherwise provided for such as fencing posts, gates, etc all as specified and directed.
Framed work as in doors or gates of angle or other section with gussest plates, rails, braces, etc, complete drilled for fixing of steel sheeting or other covering doors etc, to be prepared for hanging and sliding with and including either hooks and hinges or steel hnging door fittings and slidding bolt/ tower bolt (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete conferming to gde Fe 410 (Gde E-250) fixed in position all as specified and directed.
Pre-cast cement concrete block masnory with solid block exceeding 10cm in width and setting in cement mortar 1:4 type C1, 1:3:6 using 20mm graded stone aggregate all as specified and directed.
Rendering 15mm thick in cement mortar 1:4 on fair face of brick work or concrete surfaces finished even and smooth without using extra cement all as specified and directed.
100mm thick hard core using broken stone, broken to gauge not exceeding 63mm all as specified and directed.
75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection / path, laid and finished in bays not exceeding 3m c/c and filling the joints with mastic bitumen complete all as specified and directed.
Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregates 100 mm thick in flooring finishing surface even and smooth without using extra cement all as specified and directed.
100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base and finished even and fair all as specified and directed.
Chequered cement concrete tiles with grey cement and pigments, of size 300x300mm x 25mm thick set, jointed and pointed in neat cement slurry in floor including 15mm thick screed bed in cement mortar 1:4 all as specified and directed.
Machine Pressed precast concrete interlocking paver block rubberised any shape and size conforming to IS- 15658 - 2006 of 60 mm thickness M-35 Grade with grey cement and pigment including finishing the outer edge with cement concrete 1:2:4 using 20mm graded aggregate complete all as specified and directed.
Sand filling under floors or in foundations including watering and consolidation all as specified and directed.
Applying three coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces all as specified and directed.
Applying three coats of whitewash on walls on newly palstered surfaces all as specified and directed .
Preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Cleaning the existing SGSW/ CI /PVC (SWR) sewage Pipe line of any dia by mechanical means by rodding, jetting and removing all sludge and foreign matters completely and neatly from the pipe line under foul condition (including lines and manholes under blocked/ choked condition) and making the sewage lines serviceable for free flow of sewage including blocking of higher level manholes, washing with fresh water to the cleaned line by means of hydraulic/ pneumatic/ vacuum water jet etc all as specified and directed. These operation shall be carried out strictly in conformity with the provisions of 'Manual scavenging (Prohibition) Act and by following all mandatory safety provisions all as specified and directed.
Cleaning of manholes of any size and depth up to 2.00 mtrs under foul condition, by removing MH covers, removing of accumulated liquid, sludge/ sediments by mechanical means, transporting the fluid/ sludge etc in covered containers by mechanical means and disposing of the same in CPCB approved central STP/ ETP facility. Cleaning of the manholes with fresh water and white washing inside MH, including petty repairs of cement mortar/ cement concrete (type B-1 1:2:4 using 20 mm graded aggregate and) patch work on holes if any made by rodents and making good to walls, placing the MH covers back intact in position and setting in cement mortar 1:6 all as specified and directed.
Cleaning and removing individual blockages in IWC/ EWC mechanically and removing all sludge and foreign matters completely, neatly and making serviceable for free flow all as specified and directed.
All as per Item No. 117 hereinbefore, but for Gully trap / nahani trap / floor trap etc including opening the gratings and replacing the covers / gratings in position and making good complete all as specified and directed.
Cleaning of septic tank / sewage sump / soak well by removing of sludge and sediments in dry or mud state by machanical means, transporting the fluids / sludge etc in covered containers machanically and burying the same in pits where directed including necessary excavation, refill and disposal of surplus soil etc, complete, cleaning of septic tank with water, placing the covers intact and removing bush / vegatation near by septic tank to and extent of 3M all round and removing of sewage water from septic tank/ sewage sump/ soak well through septic tank cleaning lorries having pumping arrangement and carrying the sewage water in tanks of lorry having 5000 liters capacity and disposal of the sewage water 15Km away from outside defence area in the places upproved by local municipality / corporation all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.50M in depth; for foundation, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil all as specified and directed.
Demolition and breaking up drain pipe (salt glazed drain pipes, AC or RCC) set in cement mortar internal dia of pipes 150mm / 160mm including under and haunching of cement concrete all as specified and directed.
160mm (outer dia) PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors or in walls all as specified and directed.
PVC (SWR) gully traps 125 x 110mm, setting and jointing with solvent cement including concrete pedestal etc complete all as specified and directed.
110mm (outer dia) PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors or in walls all as specified and directed.
PVC (SWR) bends any radius, 110mm bore all as specified and directed.
PVC (SWR) bends any radius, 110mm bore with access door all as specified and directed.
110mm dia PVC (SWR) junction single, (Single T) equal or unequal with access door all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exceeding 25cm thick using soils all as specified and directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as in soils all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for all as specified and directed.
PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundations filling and mass concrete all as specified and directed.
PCC 1:3:6 type C2 using 40mm graded stone aggregate as in surface channels and drains all as specified and directed.
Cement concrete type B1 1:2:4 using 20mm graded stone aggregate as in benching / copings including necessary formwork all as specified and directed.
Brick work with sub class B bricks straight or curved in plan exceeding 6m mean radius built in cement mortar 1:4 all as specified and directed.
All as per item No 134 except bricks (old bricks taken from item No 99) all as specified and directed
TMT bars 8mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips all as specified and directed
Precast cement concrete, type B1, 1:2:4 using 20mm graded stone aggregate, set in cement mortar 1:4 as in cover slabs all as specified and directed
Cleaning/ desilting of existing bed of the drains constructed in any masonry, average thickness not exceeding 10cm including removal of vegetarians, growth or bushes, roots and getting out including disposing off excavated silt, soil, vegeterians, shrubs etc to a distance not exc 100m where directed and deposited at a level not exceeding 1.5m above the stating point complete all as specified and directed
Cutting into existing manholes for connecting new drains of 150mm dia pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed.
Exacavating in post holes (or similar holes) each not exceeding 0.5 cu m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in Hard/ Dense soil all as specified and directed.
PCC 1:3:6 Type C2 using 40mm graded stone aggregates as in post hole foundations complete all as specified and as directed.
Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc,; flat iron fillets (for securing wire mesh etc,) including all necessary drilling,bolting or riveting, etc., and similar work conforming to Fe 410 or Fe 310 complete all as specified and directed.
Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. all as specified and directed.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 , and painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor's workshop before fabrication complete all as per specified and directed.
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, including dismantling old unserviceable AC/ GI sheet all as specified and directed.
Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe 410-0 or Fe 310-0 (Brackets over 10kg each to be measured under `Structural Steel') all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc, including provision of binding wire all as per specified and directed.
Supply only chain link MS galvanised fencing 3 to 4 mm dia wire, size of mesh 50 x 50 mm, made up to mattress or cages, all as specified and as directed.
Mild steel, plain black sheet 0.80 mm thick in wall cladding, steel gates and similar work cut to size, holes punched; including round headed screws, clout nails or rivets and fited to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc as required all as specified and as directed.
M Govindarajan
Reliance Sales Agency
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .