| 1 | L1₹42.4 LAccepted-AOC 05 PASCHIMSAGAR DIGLIPUR PASCHIMSAGAR NORTH AND MIDDLE ANDAMAN ANDAMAN NICOBAR 744202 | NORTH AND MIDDLE ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | ₹42.4 L Quoted ₹42.9 L | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹46.2 LRejected-Finance B S ROAD KOLIBARI TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | ₹46.2 L | L2 | Rejected-Finance Not being lowest bidder |
| 3 | L3₹49.5 LRejected-Finance | ₹49.5 L | L3 | Rejected-Finance Not being lowest bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not enlisted in required category c(i) |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not enlisted in required category c(i) |
| Sl No | Description | Qty | Unit | Anil Kumar Sarmah L2 | M/S LAKSHMI COOLING CENTRE L3 | M/s R S ENTERPRISE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and installation of AC Compressor of capacity 3 Phase, 5 TR package unit, Model No. ZR-72 , including compressor oil in existing position including new connections with all control lines with necessary copper fittings (which requires a welding set), copper lugs, copper cables etc with controlled unit for smooth running, complete all as specified and directed. | 6 | Each | 58,000 ₹3.5 L | 59,900 ₹3.6 L | 53,000 ₹3.2 L |
| 2.00 | Supply and installation of AC Compressor of capacity 3 Phase, 3 TR package unit, including compressor oil in existing position including new connections with all control lines with necessary copper fittings (which requires a welding set), copper lugs, copper cables etc with controlled unit for smooth running, complete all as specified and directed. | 7 | Each | 51,000 ₹3.6 L | 50,950 ₹3.6 L | 46,000 ₹3.2 L |
| 3.00 | Supply and fixing sub zero compressor controller for two compressor including connection and wiring at specified location and testing complete all as specified and directed. | 8 | Each | 24,000 ₹1.9 L | 25,450 ₹2.0 L | 21,000 ₹1.7 L |
| 4.00 | Supply and fixing sub zero compressor Timer for two compressor including connection and wiring at specified location and testing complete all as specified and directed. | 7 | Each | 12,590 ₹88,130 | 13,770 ₹96,390 | 11,500 ₹80,500 |
| 5.00 | Supply and fixing in repair HP switch for 3/5 ton compressor for cold storage plant complete all as specified and directed. | 9 | Each | 1,500 ₹13,500 | 1,875 ₹16,875 | 1,200 ₹10,800 |
| 6.00 | Supply and fixing in repair LP switch for 3/5 ton compressor for cold storage plant complete all as specified and directed. | 8 | Each | 1,400 ₹11,200 | 1,575 ₹12,600 | 1,200 ₹9,600 |
| 7.00 | Supply and fixing in repair blower fan motor (indoor unit) for 5 ton compressor as per site complete all as specified and directed. | 11 | Each | 14,500 ₹1.6 L | 16,550 ₹1.8 L | 13,500 ₹1.5 L |
| 8.00 | Supply and fixing in repair fan motor (outdoor unit) for 5 ton compressor as per site complete all as specified and directed. | 6 | Each | 20,000 ₹1.2 L | 22,750 ₹1.4 L | 17,000 ₹1.0 L |
| 9.00 | Supply and fixing in repair blower fan motor (indoor unit) for 3 ton compressor as per site complete all as specified and directed. | 7 | Each | 13,700 ₹95,900 | 17,000 ₹1.2 L | 12,000 ₹84,000 |
| 10.00 | Supply and fixing in repair fan motor (outdoor unit) for 3 ton compressor as per site complete all as specified and directed. | 4 | Each | 17,100 ₹68,400 | 17,950 ₹71,800 | 15,500 ₹62,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Dec 2025, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Chariali
REPAIR/MAINTENANCE OF SUMMER APPLIANCES, WINDOW/SPLIT ACs, COLD STORAGE, PACKAGE PLANT WITH ALLIED WORKS UNDER GE (S) TEZPUR
2025_MES_739908_1
9082
Open Tender
Civil Works
210 days
GE South Tezpur
as per NIT
4 documents required · 4 mandatory
₹500
GE South Tezpur
₹90,000
Yes
5 Feb 2026
14 Nov 2025
8 Dec 2025
14 Nov 2025
6 Dec 2025
29 Nov 2025
14 Nov 2025 - 22 Nov 2025
Amount
Supply and installation of AC Compressor of capacity 3 Phase, 5 TR package unit, Model No. ZR-72 , including compressor oil in existing position including new connections with all control lines with necessary copper fittings (which requires a welding set), copper lugs, copper cables etc with controlled unit for smooth running, complete all as specified and directed.
Supply and installation of AC Compressor of capacity 3 Phase, 3 TR package unit, including compressor oil in existing position including new connections with all control lines with necessary copper fittings (which requires a welding set), copper lugs, copper cables etc with controlled unit for smooth running, complete all as specified and directed.
Supply and fixing sub zero compressor controller for two compressor including connection and wiring at specified location and testing complete all as specified and directed.
Supply and fixing sub zero compressor Timer for two compressor including connection and wiring at specified location and testing complete all as specified and directed.
Supply and fixing in repair HP switch for 3/5 ton compressor for cold storage plant complete all as specified and directed.
Supply and fixing in repair LP switch for 3/5 ton compressor for cold storage plant complete all as specified and directed.
Supply and fixing in repair blower fan motor (indoor unit) for 5 ton compressor as per site complete all as specified and directed.
Supply and fixing in repair fan motor (outdoor unit) for 5 ton compressor as per site complete all as specified and directed.
Supply and fixing in repair blower fan motor (indoor unit) for 3 ton compressor as per site complete all as specified and directed.
Supply and fixing in repair fan motor (outdoor unit) for 3 ton compressor as per site complete all as specified and directed.
Supply and fixing in repair temperature gauge for both cold room and cool room in showing centrigrade and ferenheit complete all as specified and directed.
Supply and charging of refrigerent gas R-22 for cold storage plant complete all as specified and directed.
Supply and fixing in repair blower fan blade (indoor unit) for 5 ton compressor complete all as specified and directed.
Supply and fixing in repair three pole contactor MNX 18 suitable for 3 phase 5 TR package type AC capacity including making necessary complete all as specified and directed.
Supply and fixing in repair Conactor assay suitable for 3 phase 5 TR package type AC capacity including making necessary connection complete all as specified and directed.
Supply and fixing in repair drier filter of 5/8 inch type for cold storage plant complete all as specified and directed.
Supply and fix in repair of four core cable copper conductor PVC insulated multistranded sheathed 1100 Volt grade 2.5 sqmm complete all as specified and directed.
S&F Indoor unit condensor coil suitable for 3 phase 5 TR package type AC capacity including making necessary connection complete all as specified and directed.
S&F Outdoor unit condensor coil suitable for 3 phase 5 TR package type AC capacity including making necessary connection complete all as specified and directed.
S&F Indoor unit condensor coil suitable for 3 phase 3 TR package type AC capacity including making necessary connection complete all as specified and directed.
S&F Outdoor unit condensor coil suitable for 3 phase 3 TR package type AC capacity including making necessary connection complete all as specified and directed.
M&L for carrying out pressure test of the 3 phase 3/5 TR package type AC system connection to open type /sealed compressor unit and checking for leakage with filling nitrogen gas to required pressure rectify leakage and again testing to the entire satisfaction of GE complete all as specified and directed.
Supply and fixing in repair nitrile insulation 7/8' (11x5 mtr) for insluating refrigerent flow copper tube complete all as specified and directed.
Supply and fix in repair of rubber mounting pad for package AC outdoor unit complete all as specified and directed.
Supply and fixing in repair 440 Volts MCCB , Four pole ,"C" curve , 125 Amps 25 KA breaking capacity complete all as specified and directed.
Supply and fix MCCB 4 pole, microprocessor based Release range 100 Amps to 250 Amps,415V,AC,50Hz ,36 KA Manual versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.4 - 1.0 x In ,Adjustable Short Circuit setting: 1.5 - 10 x Ir , ,Wide Range of snap fit Internal and External Accessories including Taking down old MCCB Complete all as specified and directed by Engineer-in-chargend.
Air Conditioner M&L for taking out u/s air conditioner window/ split type in capacity 1.5 TR and 2 TR for replacing to u/s spare parts / carrying out neccessary repairing works/ shifting location/ gas re-filling etc in any make /model all as site with connecting accessories from existing location after removing of all connections safely and transportation from site to work shop and back (if required) at same after repairing work complete all specified and as directed. Note :- (i) Connecting accessories will be taken in safe custody by contractor for re-using at same. (ii) All spare parts shall be measured and paid saparately under relevant items.
M&L for overhauling, dusting, cleaning by compressed air, washing using causting soda mixed with water after scraping to old paint coat to be preparing the surface for re-painting to air condioner in any type /make/ model/ cap/ etc all as site using heat resistive/ synthetic enamel paint by paint spray gun in two coats over one coat of red oxide primer and indication marking by diffirent colour in standard size of letter complete all specified and as directed . Note :- (i) All spare parts required to servicing shall be measured and paid separetly under relevant item.
Supply and re- filling/ charging of refrigerant gas of R-134A,R-32, R-410A, R-22 in original to window or split type air conditioner upto 2 TR capacity with speicific pressure grade complete all as specified and as directed. Note : Grade of refrigerant shall be supplied as per model /make requirement in original.
Labour for re-fixing/installation/ connecting/ testing and commissioning of repaired air conditioner under above item in original postion all as same as per exsiting incl making electric / air connections with other site required work for serviceablity complete all as specified and as directed.
M&L for making hole for fixing of window air condioner for any type/ make/ model / capacity etc. after cutting window's net made out by MS bar or strip / brick wall etc incl all type all required insulating/ fixing materials such as thermocal/ piece of plywood etc including good disturb surface complete all as specified and directed.
Supply only rotary DC compressor unit for invertor window type cap upto 1.5 TR 230 V, Single Phase as required in origional manufactures complete all as specified and directed.
Supply only rotary DC compressor unit for invertor split type cap upto 1.5 TR.230 V, Single Phase Complete all as specified and directed.
Supply only reciprocating / rotary AC compressor unit for window type cap upto 2.0 TR.230 V, Single Phase Complete all as specified and directed.
Supply only reciprocating / rotary AC compressor unit for split type cap upto 2.0 TR.230 V, Single Phase Complete all as specified and directed.
Supply only Starting/Running Capatior for Existing model of split/ window AC complete all as specified and directed.
Supply only condenser unit for window type AC complete all as specified and directed.
Supply only indoor unit blower fan motor for split type cap 1.5 TR. complete all as specified and directed.
Supply only out door unit fan motor for split type cap 1.5 TR complete all as specified and directed.
Supply only indoor unit blower motor for split type cap 2 TR complete all as specified and directed.
Supply only out door unit fan motor for split type cap 2 TR complete all as specified and directed.
Supply only blower fan motor for window AC cap 1.5/2 TR complete all as specified and directed.
Supply only PCB outdoor for split type AC cap 1.5/ 2 TR. as per site requirement complete all as specified and directed.
Supply only PCB indoor for split type AC cap 1.5/ 2 TR with remote Control complete all as specified and directed.
Supply only PCB for window type AC cap 1.5/ 2 TR complete all as specified and directed.
Supply only DC stapping motor complete all as specified and directed.
Supply only thermostate assembly complete all as specified and directed.
Supply only indoor condensestion unit for split type 1.5 TR AC complete all as specified and directed.
Supply only outdoor condensestion unit for split type 1.5 TR ACcomplete all as specified and directed.
Supply only indoor condensestion unit for split type 2 TR AC complete all as specified and directed.
Supply only outdoor condensestion unit for split type 2 TR AC complete all as specified and directed.
Supply only relay for AC for window /split type cap 1.5/ 2 TR complete all as specified and directed.
Supply only front panel grill complete all as specified and directed.
Supply only Remote control suitable for as site unit complete all as specified and directed.
Supply only automatic sensor card complete all as specified and directed.
Supply only Capacitor for Fan motor complete all as specified and directed.
Supply only of Air filter for split/ window type AC complete all as specified and directed.
Supply only of swing motor for indoor unit of split/window AC complete all as specified and directed.
Flushing and leak testing of complete system with Nitrogen gas and topping up compressor oil complete all as specified and directed.
Supply only for blades of model of existing/ suitable model of window/ split type (outdoor Unit) of capacity up to 2 TR complete all as specified and directed.
Supply only out door unit of air cooled split unit Air conditioners electric driven single Phase of capacity of 1.5 TR with minimum 5 star rating EER 3.2 , including iron clamp for mounting of outdoor unit complete all as specified and directed.
Supply only indoor wall mounting unit of air cooled split unit Air conditioners electric driven single Phase of capacity of 1.5 TR with minimum 5 star rating EER 3.2 complete all as specified and directed.
M&L for servicing,oiling, greasing, cleaning, dusting ,overhauling etc all as site requirement for air conditioner in all make/type/ model /cap upto 2 TR etc for making serviceable with satisfactions including disconneting, removing, re-fixing ,and re-connecting complete all as specified and directed.
M&L for replacing to rusted body portion/part of air conditioner in all make/ model / capacity etc as site using MS sheets minium 18 gauge for body and angle for frame work including jointing welding cutting etc all works finishing/ painting to matching with existing surface complete all as specified and directed.
NOTES: 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
Anil Kumar Sarmah (BID ID -3490342)
M/S LAKSHMI COOLING CENTRE (BID ID -3491228)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tenderdocus9082.pdf
Tender Documents • 1.28 MB
Addldocus.pdf
Additional Documents • 0.16 MB
BOQ_828503.xls
BOQ • 0.83 MB
Download all tender documents and submit your bid