Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC PATRA TOLI NEAR MASJID KANKE RANCHI 834002 | RANCHI | RANCHI | JHARKHAND | 834002 | ₹6.8 L | L1 | Accepted-AOC The work has been awarded to eligible lowest bidder Avish Associates with approval of competent authority. |
| 2 | Rejected-Technical BCW SANTHALDIH PURULIA BCW SANTHALDIH PURULIA BCW SANTHALDIH PURULIA PURULIA 723145 JHARKHAND INDIA | PURULIA | PURULIA | JHARKHAND | 723145 | - | - | Rejected-Technical Unsuccessful bidder for not being the L1 bidder as per NIT |
| 3 | Rejected-Technical | - | - | Rejected-Technical Unsuccessful bidder for not being the L1 bidder as per NIT |
| 4 | Rejected-Technical | - | - | Rejected-Technical Unsuccessful bidder for not being the L1 bidder as per NIT |
Tender Value
₹10.6 L
EMD Value
₹13,300
Closing Date
2 May 2026, 6:00 pmClosed
Staff Officer (Civil),CRS,Barkakana
Civil Office,CRS,Barkakana
Strengthening and Renovation of Shiv Mandir in NTS Colony under CRS, Barkakana.
2026_CCL_358554_1
CCL/CRS/BRK/Civil/ NIT/2026-27/11 dtd-21.04.2026
Open Tender
Civil Works - Others
Percentage
120 days
CRS, Barkakana
Please refer Tender documents.
3 documents required · 3 mandatory
₹13,300
10 Jul 2026
21 Apr 2026
4 May 2026
22 Apr 2026
2 May 2026
22 Apr 2026
22 Apr 2026 - 29 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in- Charge Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument. 25 mm thick in Grade M25 with cement content not less than 330 kg per cum | 52 | sqm | 579 | ₹30,108 |
| 2 | Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in- Charge Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument. 50 mm thick in Grade M25 with cement content not less than 330 kg per cum | 118 | sqm | 924.6 | ₹1,09,102.8 |
| 3 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. 50mm average thickness | 118 | sqm | 172.45 | ₹20,349.1 |
| 4 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. 25 mm average thickness | 52 | sqm | 85.75 | ₹4,459 |
| 5 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. Bars upto 12 mm diameter | 2,118 | mtr | 6.1 | ₹12,919.8 |
| 6 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. 26.31.1 SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer | 170 | sqm | 110.5 | ₹18,785 |
| 7 | Water proofing treatment of RCC sunshade with Zycosil/equivalent water proofing Solution (1 litre of Zycosil/equivalent & 20 litres of water stirred first & 2 litres of Zycoprime/equivalent added and stirred
(total 23 litres)) till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls. | 170 | sqm | 99.6 | ₹16,932 |
| 8 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). 12 mm average thickness. | 170 | sqm | 272.2 | ₹46,274 |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. | 100 | kg | 105.6 | ₹10,560 |
| 10 | PART B (RENOVATION)
Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed vitrified floor tiles polished finish of size Size of Tile 600 x 1200 mm. | - | sqm | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_371427.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.09 MB
BOQ_371427.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .